Alireza Kassaee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alireza Kassaee has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- David I. Rosenthal
Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
3 shared publications A Dimofte
University Pennsylvania, Philadelphia, PA
1 shared publicationA Khamene
1 shared publicationB. E. Bjärngard
Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
1 shared publicationD Stripp
1 shared publicationDavid I Rosenthala
1 shared publication
Latest Publications
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6) , 3681
SU-E-T-826: Dosimetric Comparison of Intensity-Modulated Proton Therapy and 3D Proton Radiotherapy with Passively Scattered Beams for Primary Prostate Cancer
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6) , 3681
SU-E-T-826: Dosimetric Comparison of Intensity-Modulated Proton Therapy and 3D Proton Radiotherapy with Passively Scattered Beams for Primary Prostate Cancer
- 1 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (6Part5) , 2026-2027
SU-FF-J-30: Automatic Determination of Required Adjustment in Patient Setup for Radiation Therapy
- 1 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (6Part5) , 2026-2027
SU-FF-J-30: Automatic Determination of Required Adjustment in Patient Setup for Radiation Therapy
- 1 November 2003
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 57 (4) , 1192-1195
Modification of Gill-Thomas-Cosman frame for extracranial head-and-neck stereotactic radiotherapy
- 1 November 2003
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 57 (4) , 1192-1195
Modification of Gill-Thomas-Cosman frame for extracranial head-and-neck stereotactic radiotherapy
- Open Access
- 1 January 2001
- Published by Wiley in International Journal of Cancer
- Vol. 96 (S1) , 125-130
Doses near the surface during total-body irradiation with 15 MV X-rays
An extended source–surface distance (SSD) is often employed in total‐body irradiation (TBI) to obtain fields sufficiently large to encompass the total body. It is clinically desirable to administer a uniform dose to all tissues, including the surface, especially to counteract the skin‐sparing of high‐energy X‐rays. The electrons generated from the air contribute more to the dose near the surface at extended distances than at regular SSDs. However, if further increase of the dose at shallow depths is desired a spoiler can be employed. Monte Carlo simulations were used to study these effects for the electron component of the beam and the parameters needed for the pencil‐beam dose calculation of this component. Measurements were performed to confirm these studies. The energy spectrum of electrons generated in air is independent of SSD. All the electrons in the beam, however, originate from the spoiler when one is used. The spectrum of these electrons is nearly independent of the SSD. The pencil‐beam dose kernels were calculated using the derived electron spectra. To calculate doses in the buildup region with and without a spoiler, we use one pencil‐beam kernel for the electrons generated in air and one for the electrons generated from the spoiler. Measured depth‐dose data agreed with the calculation results.
- 1 January 2001
- Published by Wiley in International Journal of Cancer
- Vol. 96 (S1) , 125-130
Open AccessDoses near the surface during total-body irradiation with 15 MV X-rays
An extended source–surface distance (SSD) is often employed in total‐body irradiation (TBI) to obtain fields sufficiently large to encompass the total body. It is clinically desirable to administer a uniform dose to all tissues, including the surface, especially to counteract the skin‐sparing of high‐energy X‐rays. The electrons generated from the air contribute more to the dose near the surface at extended distances than at regular SSDs. However, if further increase of the dose at shallow depths is desired a spoiler can be employed. Monte Carlo simulations were used to study these effects for the electron component of the beam and the parameters needed for the pencil‐beam dose calculation of this component. Measurements were performed to confirm these studies. The energy spectrum of electrons generated in air is independent of SSD. All the electrons in the beam, however, originate from the spoiler when one is used. The spectrum of these electrons is nearly independent of the SSD. The pencil‐beam dose kernels were calculated using the derived electron spectra. To calculate doses in the buildup region with and without a spoiler, we use one pencil‐beam kernel for the electrons generated in air and one for the electrons generated from the spoiler. Measured depth‐dose data agreed with the calculation results.
- Open Access
- 1 January 2001
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 2 (1) , 9-20
The dose distribution of medium energy electron boosts to the laryngectomy stoma
An en face, medium energy electron boost of approximately 10 Gy is often given to stomal and peristomal tissues. Because the boost is considered a simple treatment, CT‐based treatment planning is rarely used. Further, the results of such a plan might be inaccurate, as the complex dose distribution surrounding the stoma air cavity is poorly modeled by many treatment planning systems. We constructed three phantoms—two with a central vertical cavity to mimic the size and shape of the stoma and proximal trachea and one with a cavity inclined at 45° to the horizontal to better simulate anatomy. These were used to investigate the dose distribution surrounding the stoma. In all cases, the entrance to the stoma opening was centered in a field defined by a 7‐cm circular cutout and the phantom was irradiated at a source‐surface distance (SSD) of 100 cm with either vertically incident 9‐ or 12‐MeV electrons. Film measurements were made at a range of depths below and lateral to the cavity. For the vertical cavity phantoms, diode measurements were performed and isodose plans using CT scans of the phantoms were generated on a modern treatment planning system. For these two phantoms, the combined effects of lateral scatter from surrounding material and reduced equivalent thickness for electrons which pass directly through the cavity increases the dose within a centimeter of the bottom of cavity by as much as 50% for 9 MeV and 70% for 12 MeV. In material at the shallower (“superior”) end of the inclined cavity, a overdose was noted. The dose increase is geometry dependent and is not predicted by the available treatment planning system. The potential of such a dose increase to affect normal tissues such as the neopharynx should be considered.PACS number(s): 87.53.–j, 87.66.–a
- 1 January 2001
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 2 (1) , 9-20
Open AccessThe dose distribution of medium energy electron boosts to the laryngectomy stoma
An en face, medium energy electron boost of approximately 10 Gy is often given to stomal and peristomal tissues. Because the boost is considered a simple treatment, CT‐based treatment planning is rarely used. Further, the results of such a plan might be inaccurate, as the complex dose distribution surrounding the stoma air cavity is poorly modeled by many treatment planning systems. We constructed three phantoms—two with a central vertical cavity to mimic the size and shape of the stoma and proximal trachea and one with a cavity inclined at 45° to the horizontal to better simulate anatomy. These were used to investigate the dose distribution surrounding the stoma. In all cases, the entrance to the stoma opening was centered in a field defined by a 7‐cm circular cutout and the phantom was irradiated at a source‐surface distance (SSD) of 100 cm with either vertically incident 9‐ or 12‐MeV electrons. Film measurements were made at a range of depths below and lateral to the cavity. For the vertical cavity phantoms, diode measurements were performed and isodose plans using CT scans of the phantoms were generated on a modern treatment planning system. For these two phantoms, the combined effects of lateral scatter from surrounding material and reduced equivalent thickness for electrons which pass directly through the cavity increases the dose within a centimeter of the bottom of cavity by as much as 50% for 9 MeV and 70% for 12 MeV. In material at the shallower (“superior”) end of the inclined cavity, a overdose was noted. The dose increase is geometry dependent and is not predicted by the available treatment planning system. The potential of such a dose increase to affect normal tissues such as the neopharynx should be considered.PACS number(s): 87.53.–j, 87.66.–a
- Open Access
- 1 January 2000
- Published by Elsevier in Medical Dosimetry
- Vol. 25 (3) , 127-131
Beam spoilers versus bolus for 6 mv photon treatment of head and neck cancers
- 1 January 2000
- Published by Elsevier in Medical Dosimetry
- Vol. 25 (3) , 127-131
Open AccessBeam spoilers versus bolus for 6 mv photon treatment of head and neck cancers
- 1 February 1997
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (2) , 293-302
Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds
To match corresponding seed images in different radiographs so that the 3D seed locations can be triangulated automatically and without ambiguity requires (at least) three radiographs taken from different perspectives, and an algorithm that finds the proper permutations of the seed-image indices. Matching corresponding images in only two radiographs introduces inherent ambiguities which can be resolved only with the use of non-positional information obtained with intensive human effort. Matching images in three or more radiographs is an 'NP (Non-determinant in Polynomial time)-complete' problem. Although the matching problem is fundamental, current methods for three-radiograph seed-image matching use 'local' (seed-by-seed) methods that may lead to incorrect matchings. We describe a permutation-sampling method which not only gives good 'global' (full permutation) matches for the NP-complete three-radiograph seed-matching problem, but also determines the reliability of the radiographic data themselves, namely, whether the patient moved in the interval between radiographic perspectives.
- 1 February 1997
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (2) , 293-302
Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds
To match corresponding seed images in different radiographs so that the 3D seed locations can be triangulated automatically and without ambiguity requires (at least) three radiographs taken from different perspectives, and an algorithm that finds the proper permutations of the seed-image indices. Matching corresponding images in only two radiographs introduces inherent ambiguities which can be resolved only with the use of non-positional information obtained with intensive human effort. Matching images in three or more radiographs is an 'NP (Non-determinant in Polynomial time)-complete' problem. Although the matching problem is fundamental, current methods for three-radiograph seed-image matching use 'local' (seed-by-seed) methods that may lead to incorrect matchings. We describe a permutation-sampling method which not only gives good 'global' (full permutation) matches for the NP-complete three-radiograph seed-matching problem, but also determines the reliability of the radiographic data themselves, namely, whether the patient moved in the interval between radiographic perspectives.
- 1 November 1994
- Published by Wiley in Medical Physics
- Vol. 21 (11) , 1671-1676
Influence of cone design on the electron beam characteristics on clinical accelerators
Electron beam characteristics were investigated for different applicator cone designs. Low-energy scattered electrons from the cone housing can contribute to the skin dose. The depth dose was measured as a function of electron energies and field size for different cones. The measurements were compared with calculated 3-D dose distributions obtained from Monte-Carlo-derived energy deposition kernels [Phys. Med. Biol. 37, 391 (1992)]. This comparison shows that beam-defining cones can be fabricated to eliminate low-energy scattered electrons from the cone housing. Eliminating low-energy electrons from the cones provides depth dose (DD) characteristics for clinical electron beams that are comparable to those (1) from nearly monoenergetic electrons (as determined from the practical range of the electrons), and (2) for which the DD is nearly independent of source-to-skin distance. Measurements of DD for small circular fields were also performed. For very small field sizes, corresponding to the width of the lateral spread of a pencil beam, the theoretical and measured DD were found to depend on field size. Three-dimensional dose calculations of small and irregularly shaped electron fields are necessary to appreciate these effects.
- 1 November 1994
- Published by Wiley in Medical Physics
- Vol. 21 (11) , 1671-1676
Influence of cone design on the electron beam characteristics on clinical accelerators
Electron beam characteristics were investigated for different applicator cone designs. Low-energy scattered electrons from the cone housing can contribute to the skin dose. The depth dose was measured as a function of electron energies and field size for different cones. The measurements were compared with calculated 3-D dose distributions obtained from Monte-Carlo-derived energy deposition kernels [Phys. Med. Biol. 37, 391 (1992)]. This comparison shows that beam-defining cones can be fabricated to eliminate low-energy scattered electrons from the cone housing. Eliminating low-energy electrons from the cones provides depth dose (DD) characteristics for clinical electron beams that are comparable to those (1) from nearly monoenergetic electrons (as determined from the practical range of the electrons), and (2) for which the DD is nearly independent of source-to-skin distance. Measurements of DD for small circular fields were also performed. For very small field sizes, corresponding to the width of the lateral spread of a pencil beam, the theoretical and measured DD were found to depend on field size. Three-dimensional dose calculations of small and irregularly shaped electron fields are necessary to appreciate these effects.