Joseph E. Kiss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joseph E. Kiss has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Bryan R. Spencer
Scientific Affairs, American Red Cross, Dedham, MA
2 shared publications David J. Wright
Westat
2 shared publications- Donald Brambilla
RTI International, Rockville, MD
2 shared publications Ritchard G. Cable
American Red Cross, Farmington, Connecticut
2 shared publicationsWhitney R. Steele
Scientific Affairs, American Red Cross, Rockville, Maryland
2 shared publicationsAlan E Mast
BloodCenter of Wisconsin, Milwaukee
1 shared publication
Latest Publications
- 4 November 2023
- Published by Elsevier in Cytotherapy
- Vol. 26 (2) , 171-177
Predicting the CD34 content of mobilized peripheral blood leukapheresis products: single institution experience over 20 years
- 4 November 2023
- Published by Elsevier in Cytotherapy
- Vol. 26 (2) , 171-177
Predicting the CD34 content of mobilized peripheral blood leukapheresis products: single institution experience over 20 years
- 1 July 2021
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 131 (13)
Multiple-ancestry genome-wide association study identifies 27 loci associated with measures of hemolysis following blood storage
Background. The evolutionary pressure of endemic malaria and other erythrocytic pathogens has shaped variation in genes encoding erythrocyte structural and functional proteins, influencing responses to hemolytic stress during transfusion and disease. Methods. We sought to identify such genetic variants in blood donors by conducting a genome-wide association study (GWAS) of 12,353 volunteer donors, including 1,406 African Americans, 1,306 Asians, and 945 Hispanics, whose stored erythrocytes were characterized by quantitative assays of in vitro osmotic, oxidative, and cold-storage hemolysis. Results. GWAS revealed 27 significant loci (P < 5 × 10–8), many in candidate genes known to modulate erythrocyte structure, metabolism, and ion channels, including SPTA1, ALDH2, ANK1, HK1, MAPKAPK5, AQP1, PIEZO1, and SLC4A1/band 3. GWAS of oxidative hemolysis identified variants in genes encoding antioxidant enzymes, including GLRX, GPX4, G6PD, and SEC14L4 (Golgi-transport protein). Genome-wide significant loci were also tested for association with the severity of steady-state (baseline) in vivo hemolytic anemia in patients with sickle cell disease, with confirmation of identified SNPs in HBA2, G6PD, PIEZO1, AQP1, and SEC14L4. Conclusions. Many of the identified variants, such as those in G6PD, have previously been shown to impair erythrocyte recovery after transfusion, associate with anemia, or cause rare Mendelian human hemolytic diseases. Candidate SNPs in these genes, especially in polygenic combinations, may affect RBC recovery after transfusion and modulate disease severity in hemolytic diseases, such as sickle cell disease and malaria.
- 1 July 2021
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 131 (13)
Multiple-ancestry genome-wide association study identifies 27 loci associated with measures of hemolysis following blood storage
Background. The evolutionary pressure of endemic malaria and other erythrocytic pathogens has shaped variation in genes encoding erythrocyte structural and functional proteins, influencing responses to hemolytic stress during transfusion and disease. Methods. We sought to identify such genetic variants in blood donors by conducting a genome-wide association study (GWAS) of 12,353 volunteer donors, including 1,406 African Americans, 1,306 Asians, and 945 Hispanics, whose stored erythrocytes were characterized by quantitative assays of in vitro osmotic, oxidative, and cold-storage hemolysis. Results. GWAS revealed 27 significant loci (P < 5 × 10–8), many in candidate genes known to modulate erythrocyte structure, metabolism, and ion channels, including SPTA1, ALDH2, ANK1, HK1, MAPKAPK5, AQP1, PIEZO1, and SLC4A1/band 3. GWAS of oxidative hemolysis identified variants in genes encoding antioxidant enzymes, including GLRX, GPX4, G6PD, and SEC14L4 (Golgi-transport protein). Genome-wide significant loci were also tested for association with the severity of steady-state (baseline) in vivo hemolytic anemia in patients with sickle cell disease, with confirmation of identified SNPs in HBA2, G6PD, PIEZO1, AQP1, and SEC14L4. Conclusions. Many of the identified variants, such as those in G6PD, have previously been shown to impair erythrocyte recovery after transfusion, associate with anemia, or cause rare Mendelian human hemolytic diseases. Candidate SNPs in these genes, especially in polygenic combinations, may affect RBC recovery after transfusion and modulate disease severity in hemolytic diseases, such as sickle cell disease and malaria.
- 1 April 2020
- Published by Elsevier in Critical Care Clinics
- Vol. 36 (2) , 357-377
Thrombotic Thrombocytopenic Purpura, Heparin-Induced Thrombocytopenia, and Disseminated Intravascular Coagulation
- 1 April 2020
- Published by Elsevier in Critical Care Clinics
- Vol. 36 (2) , 357-377
Thrombotic Thrombocytopenic Purpura, Heparin-Induced Thrombocytopenia, and Disseminated Intravascular Coagulation
- 16 May 2018
- Published by Wiley in British Journal of Haematology
- Vol. 181 (5) , 590-603
How do we manage iron deficiency after blood donation?
Summary: Blood donors and the RBCs and other components they willingly provide are essential in the delivery of healthcare in all parts of the world. Nearly 70% of donated blood comes from repeat or committed donors. The amount of iron removed in the 10 min or so it takes to withdraw a unit of blood (500 ml, plus 25 ml for testing) requires over 24 weeks to replace on a “standard” diet, i.e., without added iron in the form of supplements The cumulative effect of repeat blood donations without adequate iron replacement or a longer wait between donations results in iron deficiency (ID) in many donors, low haemoglobin deferral (~8% of donation attempts), and frank anaemia in some. Moreover, ID can be associated with side effects that can impact a blood donor's health, such as fatigue, cognitive changes and other neuromuscular symptoms. In an effort to better identify and prevent ID, blood collection agencies are recommending various strategies, including changes in the donation interval, donation frequency, testing of iron status and iron supplementation. In this review, we present the evidence basis for these strategies and suggest our own approaches to improving iron balance in blood donors.
- 16 May 2018
- Published by Wiley in British Journal of Haematology
- Vol. 181 (5) , 590-603
How do we manage iron deficiency after blood donation?
Summary: Blood donors and the RBCs and other components they willingly provide are essential in the delivery of healthcare in all parts of the world. Nearly 70% of donated blood comes from repeat or committed donors. The amount of iron removed in the 10 min or so it takes to withdraw a unit of blood (500 ml, plus 25 ml for testing) requires over 24 weeks to replace on a “standard” diet, i.e., without added iron in the form of supplements The cumulative effect of repeat blood donations without adequate iron replacement or a longer wait between donations results in iron deficiency (ID) in many donors, low haemoglobin deferral (~8% of donation attempts), and frank anaemia in some. Moreover, ID can be associated with side effects that can impact a blood donor's health, such as fatigue, cognitive changes and other neuromuscular symptoms. In an effort to better identify and prevent ID, blood collection agencies are recommending various strategies, including changes in the donation interval, donation frequency, testing of iron status and iron supplementation. In this review, we present the evidence basis for these strategies and suggest our own approaches to improving iron balance in blood donors.
- 19 May 2017
- Published by Wiley in Transfusion
- Vol. 57 (7) , 1656-1664
Quantification of body iron and iron absorption in the REDS‐IIDonor Iron Status Evaluation (RISE) study
BACKGROUND: Repeated blood donation alters the iron balance of blood donors. We quantified these effects by analyzing changes in body iron as well as calculating iron absorbed per day for donors enrolled in a prospective study.STUDY DESIGN AND METHODS: For 1308 donors who completed a final study visit, we calculated total body iron at the enrollment and final visits and the change in total body iron over the course of the study. Taking into account iron lost from blood donations during the study and obligate losses, we also calculated the average amount of iron absorbed per day.RESULTS: First‐time/reactivated donors at enrollment had iron stores comparable to previous general population estimates. Repeat donors had greater donation intensity and greater mean iron losses than first‐time/reactivated donors, yet they had little change in total body iron over the study period, whereas first‐time/reactivated donors had an average 35% drop. There was higher estimated iron absorption in the repeat donors (men: 4.49 mg/day [95% confidence interval [CI], 4.41‐4.58 mg/day]; women: 3.75 mg/day [95% CI, 3.67‐3.84 mg/day]) compared with estimated iron absorption in first‐time/reactivated donors (men: 2.89 mg/day [95% CI, 2.75‐3.04 mg/day]; women: 2.76 mg/day [95% CI, 2.64‐2.87 mg/day]). The threshold for negative estimated iron stores (below “0” mg/kg stores) was correlated with the development of anemia at a plasma ferritin value of 10 ng/mL.CONCLUSIONS: These analyses provide quantitative data on changes in estimated total body iron for a broad spectrum of blood donors. In contrast to using ferritin alone, this model allows assessment of the iron content of red blood cells and the degree of both iron surplus and depletion over time.
- 19 May 2017
- Published by Wiley in Transfusion
- Vol. 57 (7) , 1656-1664
Quantification of body iron and iron absorption in the REDS‐IIDonor Iron Status Evaluation (RISE) study
BACKGROUND: Repeated blood donation alters the iron balance of blood donors. We quantified these effects by analyzing changes in body iron as well as calculating iron absorbed per day for donors enrolled in a prospective study.STUDY DESIGN AND METHODS: For 1308 donors who completed a final study visit, we calculated total body iron at the enrollment and final visits and the change in total body iron over the course of the study. Taking into account iron lost from blood donations during the study and obligate losses, we also calculated the average amount of iron absorbed per day.RESULTS: First‐time/reactivated donors at enrollment had iron stores comparable to previous general population estimates. Repeat donors had greater donation intensity and greater mean iron losses than first‐time/reactivated donors, yet they had little change in total body iron over the study period, whereas first‐time/reactivated donors had an average 35% drop. There was higher estimated iron absorption in the repeat donors (men: 4.49 mg/day [95% confidence interval [CI], 4.41‐4.58 mg/day]; women: 3.75 mg/day [95% CI, 3.67‐3.84 mg/day]) compared with estimated iron absorption in first‐time/reactivated donors (men: 2.89 mg/day [95% CI, 2.75‐3.04 mg/day]; women: 2.76 mg/day [95% CI, 2.64‐2.87 mg/day]). The threshold for negative estimated iron stores (below “0” mg/kg stores) was correlated with the development of anemia at a plasma ferritin value of 10 ng/mL.CONCLUSIONS: These analyses provide quantitative data on changes in estimated total body iron for a broad spectrum of blood donors. In contrast to using ferritin alone, this model allows assessment of the iron content of red blood cells and the degree of both iron surplus and depletion over time.
- 1 March 2015
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 35 (1) , 73-91
Laboratory and Genetic Assessment of Iron Deficiency in Blood Donors
- 1 March 2015
- Published by Elsevier in Clinics In Laboratory Medicine
- Vol. 35 (1) , 73-91
Laboratory and Genetic Assessment of Iron Deficiency in Blood Donors
- Open Access
- 10 February 2015
- Published by American Medical Association (AMA) in JAMA
- Vol. 313 (6) , 575-583
Oral Iron Supplementation After Blood Donation
It is estimated that 25% to 35% of blood donors become iron depleted from regular blood donation.1,2 In 2011, 9.2 million individuals in the United States donated 15.7 million units of red blood cells.3 Overall, 6.7% of these donors were deferred for not meeting the minimum capillary hemoglobin standard of 12.5 g/dL. Low hemoglobin, a late consequence of iron depletion, represents the single largest category of blood donor deferral and is more prevalent in women. Hemoglobin level and iron status are getting renewed attention as a donor safety issue based on increasing evidence that iron depletion is associated with fatigue,4 decreased exercise capacity,5 neurocognitive changes,6,7 pica, and restless legs syndrome.8,9
- 10 February 2015
- Published by American Medical Association (AMA) in JAMA
- Vol. 313 (6) , 575-583
Open AccessOral Iron Supplementation After Blood Donation
It is estimated that 25% to 35% of blood donors become iron depleted from regular blood donation.1,2 In 2011, 9.2 million individuals in the United States donated 15.7 million units of red blood cells.3 Overall, 6.7% of these donors were deferred for not meeting the minimum capillary hemoglobin standard of 12.5 g/dL. Low hemoglobin, a late consequence of iron depletion, represents the single largest category of blood donor deferral and is more prevalent in women. Hemoglobin level and iron status are getting renewed attention as a donor safety issue based on increasing evidence that iron depletion is associated with fatigue,4 decreased exercise capacity,5 neurocognitive changes,6,7 pica, and restless legs syndrome.8,9
- Open Access
- 13 September 2014
- Published by Wiley in American Journal of Hematology
- Vol. 90 (1) , E22
Development of a clinically significant ADAMTS13 inhibitor in a patient with hereditary thrombotic thrombocytopenic purpura
- 13 September 2014
- Published by Wiley in American Journal of Hematology
- Vol. 90 (1) , E22
Open AccessDevelopment of a clinically significant ADAMTS13 inhibitor in a patient with hereditary thrombotic thrombocytopenic purpura
- 26 April 2013
- Published by Wiley in Transfusion
- Vol. 53 (11) , 2766-2775
Laboratory variables for assessing iron deficiency in REDS‐II Iron Status Evaluation (RISE) blood donors
Background: Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management.Study Design and Methods: A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study‐II (REDS‐II) Donor Iron Status Evaluation (RISE) study who were either first‐time/reactivated (FT/RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 μg/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron‐deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE.Results: HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 μg/L was a good surrogate for assessing IDE.Conclusion: RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency.
- 26 April 2013
- Published by Wiley in Transfusion
- Vol. 53 (11) , 2766-2775
Laboratory variables for assessing iron deficiency in REDS‐II Iron Status Evaluation (RISE) blood donors
Background: Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management.Study Design and Methods: A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study‐II (REDS‐II) Donor Iron Status Evaluation (RISE) study who were either first‐time/reactivated (FT/RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 μg/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron‐deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE.Results: HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 μg/L was a good surrogate for assessing IDE.Conclusion: RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency.
- 10 December 2012
- Published by Wiley in Transfusion
- Vol. 52 (12) , 2498-2501
Telltale signs of progress in the management of thrombotic thrombocytopenic purpura
- 10 December 2012
- Published by Wiley in Transfusion
- Vol. 52 (12) , 2498-2501
Telltale signs of progress in the management of thrombotic thrombocytopenic purpura