Cécile Etard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cécile Etard has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
B. Aubert
Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France
6 shared publicationsP. Roch
3 shared publicationsD. Celier
2 shared publications- Jean Luc Réhel
Institute of Radioprotection and Nuclear Safety
2 shared publications A. Bouetté
Hôpital Armand-Trousseau, 26 avenue du Dr. Arnold-Netter, 75012 Paris, France
1 shared publicationA. Dieudonné
1 shared publication
Latest Publications
- 1 May 2017
- Published by Elsevier in Médecine Nucléaire
- Vol. 41 (3) , 170
Mise à jour des NRD en pédiatrie : enquête SFMN-SFPM-IRSN sur les pratiques
- 1 May 2017
- Published by Elsevier in Médecine Nucléaire
- Vol. 41 (3) , 170
Mise à jour des NRD en pédiatrie : enquête SFMN-SFPM-IRSN sur les pratiques
- Open Access
- 1 July 2016
- Published by Elsevier in European Journal of Cancer
- Vol. 61, 146-156
Low-dose computed tomography screening for lung cancer in populations highly exposed to tobacco: A systematic methodological appraisal of published randomised controlled trials
- 1 July 2016
- Published by Elsevier in European Journal of Cancer
- Vol. 61, 146-156
Open AccessLow-dose computed tomography screening for lung cancer in populations highly exposed to tobacco: A systematic methodological appraisal of published randomised controlled trials
- 23 October 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 164 (1-2) , 116-119
Establishment of diagnostic reference levels in cardiac CT in France: a need for patient dose optimisation
The objective of this study was to propose diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA), in the context of a large variability in patient radiation dose, and the lack of European recommendations. Volume Computed Tomography Dose Index (CTDIvol) and dose-length product (DLP) were collected from 460 CCTAs performed over a 3-month period at eight French hospitals. CCTAs (∼50 per centre) were performed using the routine protocols of the centres, and 64- to 320-detector CT scanners. ECG gating was prospective (n = 199) or retrospective (n = 261). The large gap in dose between these two modes required to propose specific DRLs: 26 and 44 mGy for CTDIvol, and 370 and 970 mGy cm for DLP, respectively. This study confirms the large variability in patient doses during CCTA and underlines the need for the optimisation of cardiac acquisition protocols. Availability of national DRLs should be mandatory in this setting.
- 23 October 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 164 (1-2) , 116-119
Establishment of diagnostic reference levels in cardiac CT in France: a need for patient dose optimisation
The objective of this study was to propose diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA), in the context of a large variability in patient radiation dose, and the lack of European recommendations. Volume Computed Tomography Dose Index (CTDIvol) and dose-length product (DLP) were collected from 460 CCTAs performed over a 3-month period at eight French hospitals. CCTAs (∼50 per centre) were performed using the routine protocols of the centres, and 64- to 320-detector CT scanners. ECG gating was prospective (n = 199) or retrospective (n = 261). The large gap in dose between these two modes required to propose specific DRLs: 26 and 44 mGy for CTDIvol, and 370 and 970 mGy cm for DLP, respectively. This study confirms the large variability in patient doses during CCTA and underlines the need for the optimisation of cardiac acquisition protocols. Availability of national DRLs should be mandatory in this setting.
- Open Access
- 1 October 2014
- Published by EDP Sciences in Radioprotection
- Vol. 49 (4) , 293
Erratum de: Irradiation des cristallins des patients par scanners de perfusion itératifs : dosimétrie et optimisation
Radioprotection, theoretical calculation of doses - radioactive fallout - biological effects of ionising radiation or radiobiology - experimental studies (dosimetry, reactor physics, radiochemistry), radiobiological risk management
- 1 October 2014
- Published by EDP Sciences in Radioprotection
- Vol. 49 (4) , 293
Open AccessErratum de: Irradiation des cristallins des patients par scanners de perfusion itératifs : dosimétrie et optimisation
Radioprotection, theoretical calculation of doses - radioactive fallout - biological effects of ionising radiation or radiobiology - experimental studies (dosimetry, reactor physics, radiochemistry), radiobiological risk management
- 1 June 2013
- Published by Elsevier in Physica Medica
- Vol. 29, e11
Lessons learned from the recent overexposures of patients in interventional radiology in France
- 1 June 2013
- Published by Elsevier in Physica Medica
- Vol. 29, e11
Lessons learned from the recent overexposures of patients in interventional radiology in France
- 1 June 2013
- Published by Elsevier in Physica Medica
- Vol. 29, e11
Estimation and calculation of patient dose in conventional radiology, interventional radiology and CT
- 1 June 2013
- Published by Elsevier in Physica Medica
- Vol. 29, e11
Estimation and calculation of patient dose in conventional radiology, interventional radiology and CT
- 14 May 2012
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 152 (4) , 334-338
National survey of patient doses from whole-body FDG PET-CT examinations in France in 2011
A national survey of patient doses from 'whole-body PET-CT' examinations was conducted within all French nuclear medicine departments in 2011. Data related to injected [(18)F]-fluorodeoxyglucose (FDG) activity and to computerised tomography (CT) parameters were received from 56 positron emission tomography (PET)-CT units (answer rate: ∼60 %). The average specific injected FDG activity was equal to 4.3 MBq kg(-1), in agreement with European recommendations. The new 'time-of-flight' technology enabled to decreasing the specific activity down to 3.5 MBq kg(-1). The results have shown that current diagnostic reference levels (DRLs) for the diagnostic trunk CT are too high for CT combined with PET, only performed in France for attenuation correction and localisation, and not for diagnostic purpose. Despite wide variations between PET-CT units (4-fold factor in CTDI(vol)), DRLs equal to 8 mGy (CTDI(vol)) and 750 mGy cm (dose-length product) could be proposed for whole-body PET-CT. The average effective dose related to whole-body PET-CT examination in France has been assessed to ∼14 mSv.
- 14 May 2012
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 152 (4) , 334-338
National survey of patient doses from whole-body FDG PET-CT examinations in France in 2011
A national survey of patient doses from 'whole-body PET-CT' examinations was conducted within all French nuclear medicine departments in 2011. Data related to injected [(18)F]-fluorodeoxyglucose (FDG) activity and to computerised tomography (CT) parameters were received from 56 positron emission tomography (PET)-CT units (answer rate: ∼60 %). The average specific injected FDG activity was equal to 4.3 MBq kg(-1), in agreement with European recommendations. The new 'time-of-flight' technology enabled to decreasing the specific activity down to 3.5 MBq kg(-1). The results have shown that current diagnostic reference levels (DRLs) for the diagnostic trunk CT are too high for CT combined with PET, only performed in France for attenuation correction and localisation, and not for diagnostic purpose. Despite wide variations between PET-CT units (4-fold factor in CTDI(vol)), DRLs equal to 8 mGy (CTDI(vol)) and 750 mGy cm (dose-length product) could be proposed for whole-body PET-CT. The average effective dose related to whole-body PET-CT examination in France has been assessed to ∼14 mSv.
- 28 January 2012
- Published by Elsevier in Médecine Nucléaire
- Vol. 36 (2) , 53-61
Enquête nationale en médecine nucléaire : radiopharmaceutiques et activités utilisés en 2007 dans le secteur public
- 28 January 2012
- Published by Elsevier in Médecine Nucléaire
- Vol. 36 (2) , 53-61
Enquête nationale en médecine nucléaire : radiopharmaceutiques et activités utilisés en 2007 dans le secteur public
- 1 November 2010
- Vol. 91 (11)
[The radiologist's responsibilities for the radiation protection of patients].
- 1 November 2010
- Vol. 91 (11)
[The radiologist's responsibilities for the radiation protection of patients].
- 1 November 2010
- Published by Elsevier in Journal de Radiologie
- Vol. 91 (11) , 1207-1211
Obligations du radiologue pour la radioprotection des patients
- 1 November 2010
- Published by Elsevier in Journal de Radiologie
- Vol. 91 (11) , 1207-1211
Obligations du radiologue pour la radioprotection des patients