U. Pliquett
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
U. Pliquett has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
C. Gusbeth
Institut für Hochleistungsimpuls-und Mikrowellentechnik, Forschungszentrum Karlsruhe, D-76133 Karlsruhe, Germany
1 shared publicationChristian A. Gusbeth
Faculty of Chemistry/Physical Chemistry, University of Bielefeld, D-33615 Bielefeld, Germany
1 shared publicationE. Gersing
1 shared publicationF. Pliquett
1 shared publication
Latest Publications
- 31 December 2004
- Published by Elsevier in Bioelectrochemistry
- Vol. 65 (1) , 27-32
Surface area involved in transdermal transport of charged species due to skin electroporation
- 31 December 2004
- Published by Elsevier in Bioelectrochemistry
- Vol. 65 (1) , 27-32
Surface area involved in transdermal transport of charged species due to skin electroporation
- 1 March 2003
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 41 (2) , 215-219
Joule heating during solid tissue electroporation
The application of high-voltage pulses to biological tissue causes not only electroporation, a non-thermal phenomenon of pore creation within a lipid membrane due to an elevated electric field, but also significant heating. Once a biological membrane is porated, the current density increases several times, causing Joule heating. A combined experimental and theoretical study is reported. The theoretical temperature rise for a 1.25kV cm−1, 6ms pulse is about 11.2K for a tissue conductivity of 0.5Sm−1 (i.e. myocardial tissue) during high-voltage application. Owing to the inhomogeneous electric field obtained with the use of needle electrodes, the temperature rises first at the electrodes, where the field strength reaches a maximum. Only for highly conductive tissue such as muscle was a temperature effect primarily observed in the bulk. Even if the temperature effect is biologically insignificant, it can affect the creation of stabile aqueous pathways by electroporation. The calculation of temperature distribution during high-voltage application, taking the electric field strength and the heat transfer into account, can be a useful tool for electrode optimisation.
- 1 March 2003
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 41 (2) , 215-219
Joule heating during solid tissue electroporation
The application of high-voltage pulses to biological tissue causes not only electroporation, a non-thermal phenomenon of pore creation within a lipid membrane due to an elevated electric field, but also significant heating. Once a biological membrane is porated, the current density increases several times, causing Joule heating. A combined experimental and theoretical study is reported. The theoretical temperature rise for a 1.25kV cm−1, 6ms pulse is about 11.2K for a tissue conductivity of 0.5Sm−1 (i.e. myocardial tissue) during high-voltage application. Owing to the inhomogeneous electric field obtained with the use of needle electrodes, the temperature rises first at the electrodes, where the field strength reaches a maximum. Only for highly conductive tissue such as muscle was a temperature effect primarily observed in the bulk. Even if the temperature effect is biologically insignificant, it can affect the creation of stabile aqueous pathways by electroporation. The calculation of temperature distribution during high-voltage application, taking the electric field strength and the heat transfer into account, can be a useful tool for electrode optimisation.
- 1 February 2000
- Published by Elsevier in Bioelectrochemistry
- Vol. 51 (1) , 75-79
Overcoming electrically induced artifacts in penetration studies with fluorescent tracers
- 1 February 2000
- Published by Elsevier in Bioelectrochemistry
- Vol. 51 (1) , 75-79
Overcoming electrically induced artifacts in penetration studies with fluorescent tracers
- 1 January 2000
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 45 (1-2) , 6-13
Evaluation of Fast Time-domain Based Impedance Measurements on Biological Tissue - Beurteilung schneller Impedanzmessungen im Zeitbereich an biologischen Geweben
Bio-impedance measurements are widely used for characterization of biological objects. Although the measured impedance of such objects is independent of the measurement method used, slight differences between measurements in the frequency and time domain are found. For many practical applications time domain based measurements are advantageous, but they are often rejected as not accurate. In order to show their suitability for bio-impedance measurements we used a special arrangement of time domain and frequency domain based measurements at the same biological specimen (canine liver) with the same electrodes. A reasonable coincidence in the measurement results could be shown. Moreover we used only a fraction of the time domain measurement data in order to demonstrate a significant reduction in measurement time while maintaining a reasonable accuracy. An algorithm for fast processing of the time domain data without transformation into the frequency domain is provided.
- 1 January 2000
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 45 (1-2) , 6-13
Evaluation of Fast Time-domain Based Impedance Measurements on Biological Tissue - Beurteilung schneller Impedanzmessungen im Zeitbereich an biologischen Geweben
Bio-impedance measurements are widely used for characterization of biological objects. Although the measured impedance of such objects is independent of the measurement method used, slight differences between measurements in the frequency and time domain are found. For many practical applications time domain based measurements are advantageous, but they are often rejected as not accurate. In order to show their suitability for bio-impedance measurements we used a special arrangement of time domain and frequency domain based measurements at the same biological specimen (canine liver) with the same electrodes. A reasonable coincidence in the measurement results could be shown. Moreover we used only a fraction of the time domain measurement data in order to demonstrate a significant reduction in measurement time while maintaining a reasonable accuracy. An algorithm for fast processing of the time domain data without transformation into the frequency domain is provided.