Serguei Y. Semenov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Serguei Y. Semenov has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
A.E. Bulyshev
4 shared publicationsA.E. Souvorov
4 shared publicationsA.G. Nazarov
4 shared publicationsG.P. Tatsis
4 shared publicationsR.H. Svenson
4 shared publicationsAlexander E. Bulyshev
Carolinas Medical Center
3 shared publications
Latest Publications
- 1 March 2003
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 31 (3) , 262-270
Microwave Tomography for Detection/Imaging of Myocardial Infarction. I. Excised Canine Hearts
We have demonstrated previously that the dielectric properties of myocardium at microwave spectrum are a sensitive indicator of its blood content, ischemia, and infarction. The purpose of this study is to validate the feasibility of microwave tomography for detection of myocardial infarction based on the differences in dielectric properties between normal and infarcted tissues. Excised canine hearts with two weeks myocardial infarction were imaged. Tomographic imaging experiments were conducted using a three-dimensional (3D) microwave tomographic system operating at a frequency of 1.0 GHz. To obtain the images, we used 3D reconstruction algorithms. Images of excised canine hearts with myocardial infarction were obtained at a frequency of 1 GHz, applicable for whole body imaging. Microwave tomographic images were compared with anatomical slices. The comparison confirms that microwave tomography is capable of detection of myocardial infarction. © 2003 Biomedical Engineering Society. PAC2003: 8757Gg, 8763-d, 8719Hh
- 1 March 2003
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 31 (3) , 262-270
Microwave Tomography for Detection/Imaging of Myocardial Infarction. I. Excised Canine Hearts
We have demonstrated previously that the dielectric properties of myocardium at microwave spectrum are a sensitive indicator of its blood content, ischemia, and infarction. The purpose of this study is to validate the feasibility of microwave tomography for detection of myocardial infarction based on the differences in dielectric properties between normal and infarcted tissues. Excised canine hearts with two weeks myocardial infarction were imaged. Tomographic imaging experiments were conducted using a three-dimensional (3D) microwave tomographic system operating at a frequency of 1.0 GHz. To obtain the images, we used 3D reconstruction algorithms. Images of excised canine hearts with myocardial infarction were obtained at a frequency of 1 GHz, applicable for whole body imaging. Microwave tomographic images were compared with anatomical slices. The comparison confirms that microwave tomography is capable of detection of myocardial infarction. © 2003 Biomedical Engineering Society. PAC2003: 8757Gg, 8763-d, 8719Hh
- 7 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 21 (6) , 703-707
Dielectrical spectroscopy of canine myocardium during acute ischemia and hypoxia at frequency spectrum from 100 kHz to 6 GHz
We studied dielectrical properties of canine myocardium during acute ischemia and hypoxia using dielectrical spectroscopy method at frequency spectrum from 100 kHz to 6 GHz. This study was conducted on a group of six canines with acute ischemia and seven canines with hypoxia. Hypoxia (10% for 30 min) decreases myocardial resistance (/spl rho/), while the dielectrical permittivity (/spl epsi/') of the myocardial tissue remains statistically unchanged. Acute ischemia for 2 hr causes significant frequency-dependent changes in both /spl epsi/' and /spl rho/ of myocardial tissue. Myocardial resistance increases, while the sign and amplitude of changes in the myocardial /spl epsi/' are frequency and time dependent. These observations open up an opportunity for assessing the properties of myocardial tissue using dielectrical spectroscopy as well as noninvasively with the help of imaging methods based on electrical impedance and microwave tomography.
- 7 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 21 (6) , 703-707
Dielectrical spectroscopy of canine myocardium during acute ischemia and hypoxia at frequency spectrum from 100 kHz to 6 GHz
We studied dielectrical properties of canine myocardium during acute ischemia and hypoxia using dielectrical spectroscopy method at frequency spectrum from 100 kHz to 6 GHz. This study was conducted on a group of six canines with acute ischemia and seven canines with hypoxia. Hypoxia (10% for 30 min) decreases myocardial resistance (/spl rho/), while the dielectrical permittivity (/spl epsi/') of the myocardial tissue remains statistically unchanged. Acute ischemia for 2 hr causes significant frequency-dependent changes in both /spl epsi/' and /spl rho/ of myocardial tissue. Myocardial resistance increases, while the sign and amplitude of changes in the myocardial /spl epsi/' are frequency and time dependent. These observations open up an opportunity for assessing the properties of myocardial tissue using dielectrical spectroscopy as well as noninvasively with the help of imaging methods based on electrical impedance and microwave tomography.
- 7 August 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 49 (1) , 55-63
Three-dimensional microwave tomography: initial experimental imaging of animals
The purpose of this study was to construct a microwave tomographic system capable of conducting experiments with whole scale biological objects and to demonstrate the feasibility of microwave tomography for imaging such objects using a canine model. Experiments were conducted using a three-dimensional (3-D) microwave tomographic system with working chamber dimensions of 120 cm in diameter and 135 cm in height. The operating frequency was 0.9 GHz. The object under study was located in the central area of the tomographic chamber filled with a salt solution. Experimentally measured attenuation of the electromagnetic field through the thorax was about -120 dB. To obtain images, we used various two-dimensional and 3-D reconstruction schemes. Images of the canine were obtained. In spite of imperfections, the images represent a significant milestone in the development of microwave tomography for whole body imaging and demonstrate its feasibility.
- 7 August 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 49 (1) , 55-63
Three-dimensional microwave tomography: initial experimental imaging of animals
The purpose of this study was to construct a microwave tomographic system capable of conducting experiments with whole scale biological objects and to demonstrate the feasibility of microwave tomography for imaging such objects using a canine model. Experiments were conducted using a three-dimensional (3-D) microwave tomographic system with working chamber dimensions of 120 cm in diameter and 135 cm in height. The operating frequency was 0.9 GHz. The object under study was located in the central area of the tomographic chamber filled with a salt solution. Experimentally measured attenuation of the electromagnetic field through the thorax was about -120 dB. To obtain images, we used various two-dimensional and 3-D reconstruction schemes. Images of the canine were obtained. In spite of imperfections, the images represent a significant milestone in the development of microwave tomography for whole body imaging and demonstrate its feasibility.
- 1 May 2001
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 29 (5) , 427-435
Dielectrical Model of Cellular Structures in Radio Frequency and Microwave Spectrum. Electrically Interacting Versus Noninteracting Cells
A model of dielectrical properties of cellular structures of a tissue has been proposed. Cellular structures were presented as a composition of membrane covered spheres and cylinders that do not interact with each other. No restrictions were applied to the thickness of cellular membranes. The model was further generalized into a case of electrically interacting cells. The difference in dielectrical properties calculated with the model of electrically noninteracting versus interacting cells is inversely dependent on frequency. At biological values of cellular volume fraction near 0.7 (packed configuration) the difference is about 10%–15% in resistance and in ε primefor frequencies near 0.1 MHz. Experimental data for myocardial tissue and theoretical data, for both interacting and noninteracting models, reasonably agree at frequencies of 1–100 MHz. © 2001 Biomedical Engineering Society. PAC01: 8750Jk, 8716Dg, 8750Rr, 8717Aa, 8719Ff, 8719Hh, 8710+e
- 1 May 2001
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 29 (5) , 427-435
Dielectrical Model of Cellular Structures in Radio Frequency and Microwave Spectrum. Electrically Interacting Versus Noninteracting Cells
A model of dielectrical properties of cellular structures of a tissue has been proposed. Cellular structures were presented as a composition of membrane covered spheres and cylinders that do not interact with each other. No restrictions were applied to the thickness of cellular membranes. The model was further generalized into a case of electrically interacting cells. The difference in dielectrical properties calculated with the model of electrically noninteracting versus interacting cells is inversely dependent on frequency. At biological values of cellular volume fraction near 0.7 (packed configuration) the difference is about 10%–15% in resistance and in ε primefor frequencies near 0.1 MHz. Experimental data for myocardial tissue and theoretical data, for both interacting and noninteracting models, reasonably agree at frequencies of 1–100 MHz. © 2001 Biomedical Engineering Society. PAC01: 8750Jk, 8716Dg, 8750Rr, 8717Aa, 8719Ff, 8719Hh, 8710+e
- 1 January 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (9) , 1053-1056
Computational modeling of three-dimensional microwave tomography of breast cancer
The microwave tomographic approach is proposed to detect and image breast cancers. Taking into account the big difference in dielectrical properties between normal and malignant tissues, the authors have proposed using the microwave tomographic method to image a human breast. Because of the anatomical features of the objects, this case has to be referred to the tomography with a limited angle of observation. As a result of computer experiments the authors have established that multiview cylindrical configurations are able to provide microwave tomograms of the breast with a small size tumor inside. Using the gradient method, the authors have developed a computer code to create images of the three-dimensional objects in dielectrical properties on microwave frequencies.
- 1 January 2001
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (9) , 1053-1056
Computational modeling of three-dimensional microwave tomography of breast cancer
The microwave tomographic approach is proposed to detect and image breast cancers. Taking into account the big difference in dielectrical properties between normal and malignant tissues, the authors have proposed using the microwave tomographic method to image a human breast. Because of the anatomical features of the objects, this case has to be referred to the tomography with a limited angle of observation. As a result of computer experiments the authors have established that multiview cylindrical configurations are able to provide microwave tomograms of the breast with a small size tumor inside. Using the gradient method, the authors have developed a computer code to create images of the three-dimensional objects in dielectrical properties on microwave frequencies.
- 1 January 2000
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 28 (1) , 48-54
Microwave Spectroscopy of Myocardial Ischemia and Infarction. 1. Experimental Study
The purpose of this study was to assess whether physiologic changes in canine myocardium due to coronary blood flow reduction, ischemia, and infarction could be detected by changes in dielectrical...
- 1 January 2000
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 28 (1) , 48-54
Microwave Spectroscopy of Myocardial Ischemia and Infarction. 1. Experimental Study
The purpose of this study was to assess whether physiologic changes in canine myocardium due to coronary blood flow reduction, ischemia, and infarction could be detected by changes in dielectrical...
- 1 January 2000
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 28 (1) , 55-60
Microwave spectroscopy of myocardial ischemia and infarction. 2. Biophysical reconstruction.
- 1 January 2000
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 28 (1) , 55-60
Microwave spectroscopy of myocardial ischemia and infarction. 2. Biophysical reconstruction.
- 1 January 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 46 (8) , 937-946
Three-dimensional microwave tomography: experimental prototype of the system and vector Born reconstruction method
A method of image reconstruction in three-dimensional (3-D) microwave tomography in a weak dielectric contrast case has been developed. By utilizing only one component of the vector electromagnetic field this method allows successful reconstruction of images of 3-D mathematical phantoms. A prototype of the 3-D microwave tomographic system capable of imaging 3-D objects has been constructed. The system operates at a frequency of 2.36 GHz and utilizes a code-division technique. With dimensions of the cylindrical working chamber z = 40 cm and d = 60 cm, the system allows measurement of an attenuation up to 120 dB having signal-to-noise ratio about 30 dB. The direct problem solutions for different mathematical approaches were compared with an experimentally measured field distribution inside the working chamber. The tomographic system and the reconstruction method were tested in simple experimental imaging.
- 1 January 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 46 (8) , 937-946
Three-dimensional microwave tomography: experimental prototype of the system and vector Born reconstruction method
A method of image reconstruction in three-dimensional (3-D) microwave tomography in a weak dielectric contrast case has been developed. By utilizing only one component of the vector electromagnetic field this method allows successful reconstruction of images of 3-D mathematical phantoms. A prototype of the 3-D microwave tomographic system capable of imaging 3-D objects has been constructed. The system operates at a frequency of 2.36 GHz and utilizes a code-division technique. With dimensions of the cylindrical working chamber z = 40 cm and d = 60 cm, the system allows measurement of an attenuation up to 120 dB having signal-to-noise ratio about 30 dB. The direct problem solutions for different mathematical approaches were compared with an experimentally measured field distribution inside the working chamber. The tomographic system and the reconstruction method were tested in simple experimental imaging.