A. V. Korjenevsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
A. V. Korjenevsky has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
T S Tuykin
3 shared publicationsA Karpov
Clinical Hospital No 9, Yaroslavl, Russia
1 shared publication- Anna Mazaletskaya
Laboratory of Biotechnology and Applied Bioelementology, Yaroslavl State University, Yaroslavl, Russia
1 shared publication D Mazourov
Regional Oncological Hospital, Yaroslavl, Russia
1 shared publicationI. O. Vasnev
1 shared publicationS A Sapetsky
Kotel'nikov Institute of Radioengineering and Electronics of the RAS, Mokhovaya Str. 11-7, Moscow 125009, Russia
1 shared publication
Latest Publications
- 1 July 2018
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
- Vol. 2018 (7)
Development of optical detector of malignant tumors.
- 1 July 2018
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
- Vol. 2018 (7)
Development of optical detector of malignant tumors.
- 22 May 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (6) , 1204-1213
Feasibility of the backprojection method for reconstruction of low contrast perturbations in a conducting background in magnetic induction tomography
Objective. Application of the backprojection image reconstruction algorithm in magnetic induction tomography for imaging of low contrast inclusions in conductive background is investigated. Approach. Both FDTD numerical simulation and experiments with the 16-channel measuring system and saline phantom are used. Main results. It is demonstrated that spatial redistribution of the sensitivity of measurements related with background conductivity does not affect the projection lines and keeps possibility of backprojection image reconstruction, which is important in biomedical applications of MIT. Significance. The applicability of backprojection in biomedical MIT has been proved. The reconstruction algorithm is explained in detail.
- 22 May 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (6) , 1204-1213
Feasibility of the backprojection method for reconstruction of low contrast perturbations in a conducting background in magnetic induction tomography
Objective. Application of the backprojection image reconstruction algorithm in magnetic induction tomography for imaging of low contrast inclusions in conductive background is investigated. Approach. Both FDTD numerical simulation and experiments with the 16-channel measuring system and saline phantom are used. Main results. It is demonstrated that spatial redistribution of the sensitivity of measurements related with background conductivity does not affect the projection lines and keeps possibility of backprojection image reconstruction, which is important in biomedical applications of MIT. Significance. The applicability of backprojection in biomedical MIT has been proved. The reconstruction algorithm is explained in detail.
- 21 July 2010
- Published by IOP Publishing in Physiological Measurement
- Vol. 31 (8) , S127-S134
Experimental demonstration of electric field tomography
Electric field tomography (EFT) has recently been introduced in theory. It is a new kind of quasistatic tomography suitable for contactless imaging of biological tissues. Single-channel measurements have already proven the theory. Herein the first multi-channel measuring system for EFT is presented. Experiments on imaging of a test object with different geometries are described. The first EFT images obtained experimentally have been demonstrated and discussed.
- 21 July 2010
- Published by IOP Publishing in Physiological Measurement
- Vol. 31 (8) , S127-S134
Experimental demonstration of electric field tomography
Electric field tomography (EFT) has recently been introduced in theory. It is a new kind of quasistatic tomography suitable for contactless imaging of biological tissues. Single-channel measurements have already proven the theory. Herein the first multi-channel measuring system for EFT is presented. Experiments on imaging of a test object with different geometries are described. The first EFT images obtained experimentally have been demonstrated and discussed.
- 1 June 2008
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (6) , S151-S161
Phase measurement for electric field tomography
The basic principles of electric field tomography (EFT) are briefly explained. EFT system numerical simulation results are given. The comparison of images reconstructed by systems with planar and round electrode arrays is presented. Some aspects of transmitting and measuring stages are discussed. The accuracy of the phase-sensitive demodulator, which is the key element of an EFT measuring system, is evaluated experimentally.
- 1 June 2008
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (6) , S151-S161
Phase measurement for electric field tomography
The basic principles of electric field tomography (EFT) are briefly explained. EFT system numerical simulation results are given. The comparison of images reconstructed by systems with planar and round electrode arrays is presented. Some aspects of transmitting and measuring stages are discussed. The accuracy of the phase-sensitive demodulator, which is the key element of an EFT measuring system, is evaluated experimentally.
- 1 January 2008
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 72 (1) , 89-92
Planar measuring system for experiments on electric-field tomography
Physical principles of electric field tomography—a contactless method making it possible to obtain, using a quasi-static electric field, information
- 1 January 2008
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 72 (1) , 89-92
Planar measuring system for experiments on electric-field tomography
Physical principles of electric field tomography—a contactless method making it possible to obtain, using a quasi-static electric field, information
- 26 June 2007
- Published by IOP Publishing in Physiological Measurement
- Vol. 28 (7) , S279-S289
Electric field tomography: setup for single-channel measurements
Results of experiments on electric field tomography, which were carried out to test the theoretical model suggested previously, are described in this paper. The theoretical foundation of the electric field tomography and substantiation of the possibility of its biomedical application are briefly presented. An experimental setup and test samples used for measurements are described. The results of experiments are presented; their comparison with the results of numerical simulation is given. Further steps towards increasing measurement accuracy and implementation of multi-channel tomographic systems are suggested.
- 26 June 2007
- Published by IOP Publishing in Physiological Measurement
- Vol. 28 (7) , S279-S289
Electric field tomography: setup for single-channel measurements
Results of experiments on electric field tomography, which were carried out to test the theoretical model suggested previously, are described in this paper. The theoretical foundation of the electric field tomography and substantiation of the possibility of its biomedical application are briefly presented. An experimental setup and test samples used for measurements are described. The results of experiments are presented; their comparison with the results of numerical simulation is given. Further steps towards increasing measurement accuracy and implementation of multi-channel tomographic systems are suggested.
- 30 March 2005
- Published by IOP Publishing in Physiological Measurement
- Vol. 26 (2) , S101-S110
Maxwell–Wagner relaxation in electrical imaging
The electric field tomography (EFT) method exploits interaction of high-frequency electric field with an inhomogeneous conductive medium without contact with the electrodes. The interaction is accompanied by a high-frequency redistribution of free charges inside the medium and leads to small and regular phase shifts of the field in the area surrounding an object. Such a kind of phenomenon is referred to as the Maxwell-Wagner relaxation. Measuring the perturbations of the field using the set of electrodes placed around the object enables us to reconstruct the internal structure of the medium, generally the spatial distribution of a nonlinear combination of permittivity and resistivity. In the case of biomedical applications the result of measurements is determined mainly by the resistivity of the tissues. Three-dimensional simulation based on the finite element method has demonstrated the feasibility of the technique.
- 30 March 2005
- Published by IOP Publishing in Physiological Measurement
- Vol. 26 (2) , S101-S110
Maxwell–Wagner relaxation in electrical imaging
The electric field tomography (EFT) method exploits interaction of high-frequency electric field with an inhomogeneous conductive medium without contact with the electrodes. The interaction is accompanied by a high-frequency redistribution of free charges inside the medium and leads to small and regular phase shifts of the field in the area surrounding an object. Such a kind of phenomenon is referred to as the Maxwell-Wagner relaxation. Measuring the perturbations of the field using the set of electrodes placed around the object enables us to reconstruct the internal structure of the medium, generally the spatial distribution of a nonlinear combination of permittivity and resistivity. In the case of biomedical applications the result of measurements is determined mainly by the resistivity of the tissues. Three-dimensional simulation based on the finite element method has demonstrated the feasibility of the technique.
- 1 February 2004
- Published by IOP Publishing in Physiological Measurement
- Vol. 25 (1) , 391-401
Electric field tomography for contactless imaging of resistivity in biomedical applications
The technique of contactless imaging of resistivity distribution inside conductive objects, which can be applied in medical diagnostics, has been suggested and analyzed. The method exploits the interaction of a high-frequency electric field with a conductive medium. Unlike electrical impedance tomography, no electric current is injected into the medium from outside. The interaction is accompanied with excitation of high-frequency currents and redistribution of free charges inside the medium leading to strong and irregular perturbation of the field's magnitude outside and inside the object. Along with this the considered interaction also leads to small and regular phase shifts of the field in the area surrounding the object. Measuring these phase shifts using a set of electrodes placed around the object enables us to reconstruct the internal structure of the medium. The basics of this technique, which we name electric field tomography (EFT), are described, simple analytical estimations are made and requirements for measuring equipment are formulated. The realizability of the technique is verified by numerical simulations based on the finite elements method. Results of simulation have confirmed initial estimations and show that in the case of EFT even a comparatively simple filtered backprojection algorithm can be used for reconstructing the static resistivity distribution in biological tissues.
- 1 February 2004
- Published by IOP Publishing in Physiological Measurement
- Vol. 25 (1) , 391-401
Electric field tomography for contactless imaging of resistivity in biomedical applications
The technique of contactless imaging of resistivity distribution inside conductive objects, which can be applied in medical diagnostics, has been suggested and analyzed. The method exploits the interaction of a high-frequency electric field with a conductive medium. Unlike electrical impedance tomography, no electric current is injected into the medium from outside. The interaction is accompanied with excitation of high-frequency currents and redistribution of free charges inside the medium leading to strong and irregular perturbation of the field's magnitude outside and inside the object. Along with this the considered interaction also leads to small and regular phase shifts of the field in the area surrounding the object. Measuring these phase shifts using a set of electrodes placed around the object enables us to reconstruct the internal structure of the medium. The basics of this technique, which we name electric field tomography (EFT), are described, simple analytical estimations are made and requirements for measuring equipment are formulated. The realizability of the technique is verified by numerical simulations based on the finite elements method. Results of simulation have confirmed initial estimations and show that in the case of EFT even a comparatively simple filtered backprojection algorithm can be used for reconstructing the static resistivity distribution in biological tissues.
- 19 December 2001
- Published by IOP Publishing in Physiological Measurement
- Vol. 23 (1) , 33-41
Preliminary static EIT images of the thorax in health and disease
The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. The first group consisted of 22 patients with clinical diagnosis of lung cancer with tumour localization in one lung. The second group consisted of seven healthy subjects. A patient after a one-sided pneumectomy and another with one-sided emphysema diagnosis were also examined. Static EIT images of a healthy human chest and a chest with various abnormalities are given and discussed. The evaluated system distinguishably visualizes various states of lungs and thorax including lung cancer. The average static conductivity of an affected lung in the first clinical group statistically differs from the average conductivity of a healthy lung. In spite of low spatial resolution, according to preliminary results, the method can be sensitive to cancer and other lung diseases in screening investigations.
- 19 December 2001
- Published by IOP Publishing in Physiological Measurement
- Vol. 23 (1) , 33-41
Preliminary static EIT images of the thorax in health and disease
The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. The first group consisted of 22 patients with clinical diagnosis of lung cancer with tumour localization in one lung. The second group consisted of seven healthy subjects. A patient after a one-sided pneumectomy and another with one-sided emphysema diagnosis were also examined. Static EIT images of a healthy human chest and a chest with various abnormalities are given and discussed. The evaluated system distinguishably visualizes various states of lungs and thorax including lung cancer. The average static conductivity of an affected lung in the first clinical group statistically differs from the average conductivity of a healthy lung. In spite of low spatial resolution, according to preliminary results, the method can be sensitive to cancer and other lung diseases in screening investigations.