Ismo Kalevi Koponen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ismo Kalevi Koponen has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Anne Thoustrup Saber
The National Research Centre for the Working Environment, Lersø Parkallé 105, DK-2100, Copenhagen Ø, Denmark
3 shared publications - Ulla Vogel
National Research Centre for the Working Environment, Copenhagen, Denmark
3 shared publications - Anne Mette Madsen
National Research Centre for the Working Environment, Copenhagen Ø, Denmark
2 shared publications - Håkan Wallin
Institute of Public Health, University of Copenhagen. Copenhagen K, Denmark
2 shared publications - Józef Szarek
Department of Pathophysiology, Forensic Veterinary Medicine and Administration, University of Warmia and Mazury in Olsztyn, Olsztyn, Poland
2 shared publications Keld Alstrup Jensen
The Danish Nanosafety Centre, National Research Centre for Working Environment, Lersø Park Alle 105, DK-2100 Copenhagen, Denmark
2 shared publications
Latest Publications
- Open Access
- 8 December 2017
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 12 (1) , 33
Pulmonary injury associated with spray of a water-based nano-sized waterproofing product: a case study
In most reported cases of lung trauma with water proofing products, volatile organic compounds (VOC) have a prominent role. Here we report on a case involving ten workers exposed to a sprayed product containing nanoparticles in a water solution with only a few percent VOC. Ten workers suffered from respiratory symptoms following spray impregnation of hardwood furniture using a waterproofing product that contained positively charged fluorinated acrylate copolymer solid cores with a median diameter of 70 nm (1.3 w%) in aqueous suspension with 3.3 w% VOC and 0.3 w% quaternary ammonium. The worker who applied one liter of the product in a wood workshop, using an air mix spray gun, did not report any health complaints. Another worker, who entered the workshop 3 h later and had rolled and smoked two cigarettes, was hospitalized with severe chemical pneumonitis. A chest X-ray (CXR) showed bilateral infiltrative impairment in the lower lobe regions. On the next day a second CXR showed increased patchiness marking in all fields. A high-resolution Computer Tomography (CT)-scan demonstrated extensive bilateral areas of ground-glass opacities predominantly in the lower regions of the upper lobes, the right middle lobe and the apical regions of the lower lobes, compatible with severe chemical pneumonitis. On the following morning, nine workers in an adjacent workplace in the same building, experienced dry cough, chest tightness and substernal pain upon physical exercise. Reconstruction of the spray application in a climate chamber confirmed trimethyl silanol, glycol ethers and fluoroalkenes in the gas phase. Immediately after the spray application, aerosols were observed at a maximum concentration of 6.3 × 104 cm−3. Mass concentrations were 0.095 and 10 mg/m3 in the size ranges 5.6-560 nm and 0.22-30 μm, respectively, decreasing to less than 10 μg/m3 in both size ranges after 15 h. The hospitalized worker had smoked cigarettes contaminated with fluoropolymers which is a plausible explanation for the lung trauma. Respiratory symptoms in the nine workers may be caused by inhalation of particles that became airborne by resuspension from surfaces when workers entered the adjacent workplace the next day. A contribution from VOC appears less likely because measurements and modelling showed that concentrations in the mg/m3 range could have occurred only if the building was assumed to be completely airtight.
- 8 December 2017
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 12 (1) , 33
Open AccessPulmonary injury associated with spray of a water-based nano-sized waterproofing product: a case study
In most reported cases of lung trauma with water proofing products, volatile organic compounds (VOC) have a prominent role. Here we report on a case involving ten workers exposed to a sprayed product containing nanoparticles in a water solution with only a few percent VOC. Ten workers suffered from respiratory symptoms following spray impregnation of hardwood furniture using a waterproofing product that contained positively charged fluorinated acrylate copolymer solid cores with a median diameter of 70 nm (1.3 w%) in aqueous suspension with 3.3 w% VOC and 0.3 w% quaternary ammonium. The worker who applied one liter of the product in a wood workshop, using an air mix spray gun, did not report any health complaints. Another worker, who entered the workshop 3 h later and had rolled and smoked two cigarettes, was hospitalized with severe chemical pneumonitis. A chest X-ray (CXR) showed bilateral infiltrative impairment in the lower lobe regions. On the next day a second CXR showed increased patchiness marking in all fields. A high-resolution Computer Tomography (CT)-scan demonstrated extensive bilateral areas of ground-glass opacities predominantly in the lower regions of the upper lobes, the right middle lobe and the apical regions of the lower lobes, compatible with severe chemical pneumonitis. On the following morning, nine workers in an adjacent workplace in the same building, experienced dry cough, chest tightness and substernal pain upon physical exercise. Reconstruction of the spray application in a climate chamber confirmed trimethyl silanol, glycol ethers and fluoroalkenes in the gas phase. Immediately after the spray application, aerosols were observed at a maximum concentration of 6.3 × 104 cm−3. Mass concentrations were 0.095 and 10 mg/m3 in the size ranges 5.6-560 nm and 0.22-30 μm, respectively, decreasing to less than 10 μg/m3 in both size ranges after 15 h. The hospitalized worker had smoked cigarettes contaminated with fluoropolymers which is a plausible explanation for the lung trauma. Respiratory symptoms in the nine workers may be caused by inhalation of particles that became airborne by resuspension from surfaces when workers entered the adjacent workplace the next day. A contribution from VOC appears less likely because measurements and modelling showed that concentrations in the mg/m3 range could have occurred only if the building was assumed to be completely airtight.
- Open Access
- 6 September 2017
- Published by Springer Nature in Environmental Health
- Vol. 16 (1) , 1-9
Cardiovascular health effects following exposure of human volunteers during fire extinction exercises
Firefighters have increased risk of cardiovascular disease and of sudden death from coronary heart disease on duty while suppressing fires. This study investigated the effect of firefighting activities, using appropriate personal protective equipment (PPE), on biomarkers of cardiovascular effects in young conscripts training to become firefighters. Healthy conscripts (n = 43) who participated in a rescue educational course for firefighting were enrolled in the study. The exposure period consisted of a three-day training course where the conscripts participated in various firefighting exercises in a constructed firehouse and flashover container. The subjects were instructed to extinguish fires of either wood or wood with electrical cords and mattresses. The exposure to particulate matter (PM) was assessed at various locations and personal exposure was assessed by portable PM samplers and urinary excretion of 1-hydroxypyrene. Cardiovascular measurements included microvascular function and heart rate variability (HRV). The subjects were primarily exposed to PM in bystander positions, whereas self-contained breathing apparatus effectively abolished pulmonary exposure. Firefighting training was associated with elevated urinary excretion of 1-hydroxypyrene (105%, 95% CI: 52; 157%), increased body temperature, decreased microvascular function (−18%, 95% CI: -26; −9%) and altered HRV. There was no difference in cardiovascular measurements for the two types of fires. Observations from this fire extinction training show that PM exposure mainly occurs in situations where firefighters removed the self-contained breathing apparatus. Altered cardiovascular disease endpoints after the firefighting exercise period were most likely due to complex effects from PM exposure, physical exhaustion and increased core body temperature.
- 6 September 2017
- Published by Springer Nature in Environmental Health
- Vol. 16 (1) , 1-9
Open AccessCardiovascular health effects following exposure of human volunteers during fire extinction exercises
Firefighters have increased risk of cardiovascular disease and of sudden death from coronary heart disease on duty while suppressing fires. This study investigated the effect of firefighting activities, using appropriate personal protective equipment (PPE), on biomarkers of cardiovascular effects in young conscripts training to become firefighters. Healthy conscripts (n = 43) who participated in a rescue educational course for firefighting were enrolled in the study. The exposure period consisted of a three-day training course where the conscripts participated in various firefighting exercises in a constructed firehouse and flashover container. The subjects were instructed to extinguish fires of either wood or wood with electrical cords and mattresses. The exposure to particulate matter (PM) was assessed at various locations and personal exposure was assessed by portable PM samplers and urinary excretion of 1-hydroxypyrene. Cardiovascular measurements included microvascular function and heart rate variability (HRV). The subjects were primarily exposed to PM in bystander positions, whereas self-contained breathing apparatus effectively abolished pulmonary exposure. Firefighting training was associated with elevated urinary excretion of 1-hydroxypyrene (105%, 95% CI: 52; 157%), increased body temperature, decreased microvascular function (−18%, 95% CI: -26; −9%) and altered HRV. There was no difference in cardiovascular measurements for the two types of fires. Observations from this fire extinction training show that PM exposure mainly occurs in situations where firefighters removed the self-contained breathing apparatus. Altered cardiovascular disease endpoints after the firefighting exercise period were most likely due to complex effects from PM exposure, physical exhaustion and increased core body temperature.
- Open Access
- 1 December 2015
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 13 (1) , 37
Epoxy composite dusts with and without carbon nanotubes cause similar pulmonary responses, but differences in liver histology in mice following pulmonary deposition
The toxicity of dusts from mechanical abrasion of multi-walled carbon nanotube (CNT) epoxy nanocomposites is unknown. We compared the toxic effects of dusts generated by sanding of epoxy composites with and without CNT. The used CNT type was included for comparison. Mice received a single intratracheal instillation of 18, 54 and 162 μg of CNT or 54, 162 and 486 μg of the sanding dust from epoxy composite with and without CNT. DNA damage in lung and liver, lung inflammation and liver histology were evaluated 1, 3 and 28 days after intratracheal instillation. Furthermore, the mRNA expression of interleukin 6 and heme oxygenase 1 was measured in the lungs and serum amyloid A1 in the liver. Printex 90 carbon black was included as a reference particle. Pulmonary exposure to CNT and all dusts obtained by sanding epoxy composite boards resulted in recruitment of inflammatory cells into lung lumen: On day 1 after instillation these cells were primarily neutrophils but on day 3, eosinophils contributed significantly to the cell population. There were still increased numbers of neutrophils 28 days after intratracheal instillation of the highest dose of the epoxy dusts. Both CNT and epoxy dusts induced DNA damage in lung tissue up to 3 days after intratracheal instillation but not in liver tissue. There was no additive effect of adding CNT to epoxy resins for any of the pulmonary endpoints. In livers of mice instilled with CNT and epoxy dust with CNTs inflammatory and necrotic histological changes were observed, however, not in mice instilled with epoxy dust without CNT. Pulmonary deposition of epoxy dusts with and without CNT induced inflammation and DNA damage in lung tissue. There was no additive effect of adding CNT to epoxies for any of the pulmonary endpoints. However, hepatic inflammatory and necrotic histopathological changes were seen in mice instilled with sanding dust from CNT-containing epoxy but not in mice instilled with reference epoxy.
- 1 December 2015
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 13 (1) , 37
Open AccessEpoxy composite dusts with and without carbon nanotubes cause similar pulmonary responses, but differences in liver histology in mice following pulmonary deposition
The toxicity of dusts from mechanical abrasion of multi-walled carbon nanotube (CNT) epoxy nanocomposites is unknown. We compared the toxic effects of dusts generated by sanding of epoxy composites with and without CNT. The used CNT type was included for comparison. Mice received a single intratracheal instillation of 18, 54 and 162 μg of CNT or 54, 162 and 486 μg of the sanding dust from epoxy composite with and without CNT. DNA damage in lung and liver, lung inflammation and liver histology were evaluated 1, 3 and 28 days after intratracheal instillation. Furthermore, the mRNA expression of interleukin 6 and heme oxygenase 1 was measured in the lungs and serum amyloid A1 in the liver. Printex 90 carbon black was included as a reference particle. Pulmonary exposure to CNT and all dusts obtained by sanding epoxy composite boards resulted in recruitment of inflammatory cells into lung lumen: On day 1 after instillation these cells were primarily neutrophils but on day 3, eosinophils contributed significantly to the cell population. There were still increased numbers of neutrophils 28 days after intratracheal instillation of the highest dose of the epoxy dusts. Both CNT and epoxy dusts induced DNA damage in lung tissue up to 3 days after intratracheal instillation but not in liver tissue. There was no additive effect of adding CNT to epoxy resins for any of the pulmonary endpoints. In livers of mice instilled with CNT and epoxy dust with CNTs inflammatory and necrotic histological changes were observed, however, not in mice instilled with epoxy dust without CNT. Pulmonary deposition of epoxy dusts with and without CNT induced inflammation and DNA damage in lung tissue. There was no additive effect of adding CNT to epoxies for any of the pulmonary endpoints. However, hepatic inflammatory and necrotic histopathological changes were seen in mice instilled with sanding dust from CNT-containing epoxy but not in mice instilled with reference epoxy.
- 11 April 2015
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 59 (6) , 749-763
Worker Exposure and High Time-Resolution Analyses of Process-Related Submicrometre Particle Concentrations at Mixing Stations in Two Paint Factories
The paint and coatings industry is known to have significant particulate matter (PM) emissions to the atmosphere. However, exposure levels are not studied in detail especially when considering submicrometre (PM1) and ultrafine particles (particle diameter below 100nm). The evidence is increasing that pulmonary exposures to these size fractions are potentially very harmful. This study investigates particle emissions during powder handling and paint mixing in two paint factories at two mixing stations in each factory. In each case measurements were made simultaneously at the mixing station (near-field; NF), as well as at 5–15 m distance into the workroom far-field (FF), and in the workers breathing zone. Particle concentrations (5nm to 30 µm) were measured using high time-resolution particle instruments and gravimetrically using PM1 cyclone filter samplers. The PM1 filters were also characterized by scanning electron microscopy (SEM). The NF particle and dust concentration levels were linked to pouring powder and were used to characterize the emissions and efficiencies of localized controls. NF particle number concentrations were 1000–40000cm−3 above FF concentrations. NF particles were mainly between 100 and 500nm and emissions appeared to occur in short bursts. Personal PM1 exposure levels varied between 0.156 and 0.839mg m−3 and were 1.6–15 times higher than stationary NF PM1 concentrations. SEM results verified that the personal exposure and NF particles were strongly dominated by the pigments and fillers used. Better understanding of the entire temporal personal exposure could be improved by using real-time particle monitors for personal exposure measurements. This study provides better insight into PM exposure characteristics and concentration levels in the paint industry.
- 11 April 2015
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 59 (6) , 749-763
Worker Exposure and High Time-Resolution Analyses of Process-Related Submicrometre Particle Concentrations at Mixing Stations in Two Paint Factories
The paint and coatings industry is known to have significant particulate matter (PM) emissions to the atmosphere. However, exposure levels are not studied in detail especially when considering submicrometre (PM1) and ultrafine particles (particle diameter below 100nm). The evidence is increasing that pulmonary exposures to these size fractions are potentially very harmful. This study investigates particle emissions during powder handling and paint mixing in two paint factories at two mixing stations in each factory. In each case measurements were made simultaneously at the mixing station (near-field; NF), as well as at 5–15 m distance into the workroom far-field (FF), and in the workers breathing zone. Particle concentrations (5nm to 30 µm) were measured using high time-resolution particle instruments and gravimetrically using PM1 cyclone filter samplers. The PM1 filters were also characterized by scanning electron microscopy (SEM). The NF particle and dust concentration levels were linked to pouring powder and were used to characterize the emissions and efficiencies of localized controls. NF particle number concentrations were 1000–40000cm−3 above FF concentrations. NF particles were mainly between 100 and 500nm and emissions appeared to occur in short bursts. Personal PM1 exposure levels varied between 0.156 and 0.839mg m−3 and were 1.6–15 times higher than stationary NF PM1 concentrations. SEM results verified that the personal exposure and NF particles were strongly dominated by the pigments and fillers used. Better understanding of the entire temporal personal exposure could be improved by using real-time particle monitors for personal exposure measurements. This study provides better insight into PM exposure characteristics and concentration levels in the paint industry.
- Open Access
- 1 January 2012
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 9 (1) , 4
Nanotitanium dioxide toxicity in mouse lung is reduced in sanding dust from paint
Little is known of how the toxicity of nanoparticles is affected by the incorporation in complex matrices. We compared the toxic effects of the titanium dioxide nanoparticle UV-Titan L181 (NanoTiO2), pure or embedded in a paint matrix. We also compared the effects of the same paint with and without NanoTiO2.
- 1 January 2012
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 9 (1) , 4
Open AccessNanotitanium dioxide toxicity in mouse lung is reduced in sanding dust from paint
Little is known of how the toxicity of nanoparticles is affected by the incorporation in complex matrices. We compared the toxic effects of the titanium dioxide nanoparticle UV-Titan L181 (NanoTiO2), pure or embedded in a paint matrix. We also compared the effects of the same paint with and without NanoTiO2.
- Open Access
- 19 May 2010
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 21 (4) , 408-418
Comparison of dust released from sanding conventional and nanoparticle-doped wall and wood coatings
Introduction of engineered nanoparticles (ENPs) into traditional surface coatings (e.g., paints, lacquers, fillers) may result in new exposures to both workers and consumers and possibly also a new risk to their health. During finishing and renovation, such products may also be a substantial source of exposure to ENPs or aggregates thereof. This study investigates the particle size distributions (5.6 nm–19.8 μm) and the total number of dust particles generated during sanding of ENP-doped paints, lacquers, and fillers as compared to their conventional counterparts. In all products, the dust emissions from sanding were found to consist of five size modes: three modes under 1 μm and two modes around 1 and 2 μm. Corrected for the emission from the sanding machine, the sanding dust, was dominated by 100–300 nm size particles, whereas the mass and surface area spectra were dominated by the micrometer modes. Adding ENPs to the studied products only vaguely affected the geometric mean diameters of the particle modes in the sanding dust when compared to their reference products. However, we observed considerable differences in the number concentrations in the different size modes, but still without revealing a clear effect of ENPs on dust emissions from sanding.
- 19 May 2010
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 21 (4) , 408-418
Open AccessComparison of dust released from sanding conventional and nanoparticle-doped wall and wood coatings
Introduction of engineered nanoparticles (ENPs) into traditional surface coatings (e.g., paints, lacquers, fillers) may result in new exposures to both workers and consumers and possibly also a new risk to their health. During finishing and renovation, such products may also be a substantial source of exposure to ENPs or aggregates thereof. This study investigates the particle size distributions (5.6 nm–19.8 μm) and the total number of dust particles generated during sanding of ENP-doped paints, lacquers, and fillers as compared to their conventional counterparts. In all products, the dust emissions from sanding were found to consist of five size modes: three modes under 1 μm and two modes around 1 and 2 μm. Corrected for the emission from the sanding machine, the sanding dust, was dominated by 100–300 nm size particles, whereas the mass and surface area spectra were dominated by the micrometer modes. Adding ENPs to the studied products only vaguely affected the geometric mean diameters of the particle modes in the sanding dust when compared to their reference products. However, we observed considerable differences in the number concentrations in the different size modes, but still without revealing a clear effect of ENPs on dust emissions from sanding.
- 1 February 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 151 (1) , 012048
Sanding dust from nanoparticle-containing paints: Physical characterisation
Increasing use of nanoparticles in different industrial applications has raised a new potential health risk to the workers as well as to the consumers. This study investigates the particle size distributions of sanding dust released from paints produced with and without engineered nanoparticles. Dust emissions from sanding painted plates were found to consist of five size modes; three modes under 1 μm and two modes around 1 and 2 μm. We observed that the sander was the only source of particles smaller than 50 nm and they dominated the number concentration spectra. Mass and surface area spectra were dominated by the 1 and 2 μm modes. Addition of nanoparticles caused only minor changes in the geometric mean diameters of the particle modes generated during sanding of two paints doped with 17 nm TiO2 and 95 nm Carbon Black nanoparticles as compared to the size modes generated during sanding a conventional reference paint. However, the number concentrations in the different size modes varied considerably in between the two NP-doped paints and the reference paint. Therefore, from a physical point of view, there may be a difference in the exposure risk during sanding surfaces covered with nanoparticle-based paints as compared to sanding conventional paints.
- 1 February 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 151 (1) , 012048
Sanding dust from nanoparticle-containing paints: Physical characterisation
Increasing use of nanoparticles in different industrial applications has raised a new potential health risk to the workers as well as to the consumers. This study investigates the particle size distributions of sanding dust released from paints produced with and without engineered nanoparticles. Dust emissions from sanding painted plates were found to consist of five size modes; three modes under 1 μm and two modes around 1 and 2 μm. We observed that the sander was the only source of particles smaller than 50 nm and they dominated the number concentration spectra. Mass and surface area spectra were dominated by the 1 and 2 μm modes. Addition of nanoparticles caused only minor changes in the geometric mean diameters of the particle modes generated during sanding of two paints doped with 17 nm TiO2 and 95 nm Carbon Black nanoparticles as compared to the size modes generated during sanding a conventional reference paint. However, the number concentrations in the different size modes varied considerably in between the two NP-doped paints and the reference paint. Therefore, from a physical point of view, there may be a difference in the exposure risk during sanding surfaces covered with nanoparticle-based paints as compared to sanding conventional paints.