Latest Publications
- 9 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 2915-2922
Skeletal dosimetry in cone beam computed tomography
Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image‐guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase‐space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro‐CT images, filling the relevant phantom voxels, which are , with microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc‐based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase‐space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel‐by‐voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens , and 80% greater than the average dose to brain . Average dose to RBM, on the other hand, is typically only of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.
- 9 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 2915-2922
Skeletal dosimetry in cone beam computed tomography
Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image‐guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase‐space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro‐CT images, filling the relevant phantom voxels, which are , with microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc‐based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase‐space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel‐by‐voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens , and 80% greater than the average dose to brain . Average dose to RBM, on the other hand, is typically only of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.
- 13 September 2007
- Published by Wiley in Medical Physics
- Vol. 34 (10) , 3794-3807
A “HOWFARLESS” option to increase efficiency of homogeneous phantom calculations with DOSXYZnrc
Peer reviewed: NoNRC publication: Ye
- 13 September 2007
- Published by Wiley in Medical Physics
- Vol. 34 (10) , 3794-3807
A “HOWFARLESS” option to increase efficiency of homogeneous phantom calculations with DOSXYZnrc
Peer reviewed: NoNRC publication: Ye
- 25 January 2007
- Published by Wiley in Medical Physics
- Vol. 34 (2) , 647-650
Technical note: Overprediction of dose with default PRESTA-I boundary crossing in DOSXYZnrc and BEAMnrc
Peer reviewed: NoNRC publication: Ye
- 25 January 2007
- Published by Wiley in Medical Physics
- Vol. 34 (2) , 647-650
Technical note: Overprediction of dose with default PRESTA-I boundary crossing in DOSXYZnrc and BEAMnrc
Peer reviewed: NoNRC publication: Ye
- 26 August 2005
- Published by Wiley in Medical Physics
- Vol. 32 (9) , 2918-2927
Influence of ion chamber response on in-air profile measurements in megavoltage photon beams
Peer reviewed: NoNRC publication: Ye
- 26 August 2005
- Published by Wiley in Medical Physics
- Vol. 32 (9) , 2918-2927
Influence of ion chamber response on in-air profile measurements in megavoltage photon beams
Peer reviewed: NoNRC publication: Ye
- 1 October 2004
- Published by Wiley in Medical Physics
- Vol. 31 (10) , 2883-2898
Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
The introduction into the BEAMnrc code of a new variance reduction technique, called directional bremsstrahlung splitting (DBS), is described. DBS uses a combination of interaction splitting for bremsstrahlung, annihilation, Compton scattering, pair production and photoabsorption, and Russian Roulette to achieve a much better efficiency of photon beam treatment head simulations compared to the splitting techniques already available in BEAMnrc (selective bremsstrahlung splitting, SBS, and uniform bremsstrahlung splitting, UBS). In a simulated photon beam ( field) photon fluence efficiency in the beam using DBS is over 8 times higher than with optimized SBS and over 20 times higher than with UBS, with a similar improvement in electron fluence efficiency in the beam. Total dose efficiency in a central‐axis depth‐dose curve improves by a factor of 6.4 over SBS at all depths in the phantom. The performance of DBS depends on the details of the accelerator being simulated. At higher energies, the relative improvement in efficiency due to DBS decreases somewhat, but is still a factor of 3.5 improvement over SBS for total dose efficiency using DBS in a simulated photon beam. Increasing the field size of the simulated beam to (broad beam) causes the relative efficiency improvement of DBS to decrease by a factor of but is still up to 7 times more efficient than with SBS.
- 1 October 2004
- Published by Wiley in Medical Physics
- Vol. 31 (10) , 2883-2898
Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
The introduction into the BEAMnrc code of a new variance reduction technique, called directional bremsstrahlung splitting (DBS), is described. DBS uses a combination of interaction splitting for bremsstrahlung, annihilation, Compton scattering, pair production and photoabsorption, and Russian Roulette to achieve a much better efficiency of photon beam treatment head simulations compared to the splitting techniques already available in BEAMnrc (selective bremsstrahlung splitting, SBS, and uniform bremsstrahlung splitting, UBS). In a simulated photon beam ( field) photon fluence efficiency in the beam using DBS is over 8 times higher than with optimized SBS and over 20 times higher than with UBS, with a similar improvement in electron fluence efficiency in the beam. Total dose efficiency in a central‐axis depth‐dose curve improves by a factor of 6.4 over SBS at all depths in the phantom. The performance of DBS depends on the details of the accelerator being simulated. At higher energies, the relative improvement in efficiency due to DBS decreases somewhat, but is still a factor of 3.5 improvement over SBS for total dose efficiency using DBS in a simulated photon beam. Increasing the field size of the simulated beam to (broad beam) causes the relative efficiency improvement of DBS to decrease by a factor of but is still up to 7 times more efficient than with SBS.
- Top Cited Papers
- 15 November 2002
- Published by Wiley in Medical Physics
- Vol. 29 (12) , 2745-2752
History by history statistical estimators in the BEAM code system
A history by history method for estimating uncertainties has been implemented in the BEAMnrc and DOSXYZnrc codes replacing the method of statistical batches. This method groups scored quantities (e.g., dose) by primary history. When phase‐space sources are used, this method groups incident particles according to the primary histories that generated them. This necessitated adding markers (negative energy) to phase‐space files to indicate the first particle generated by a new primary history. The new method greatly reduces the uncertainty in the uncertainty estimate. The new method eliminates one dimension (which kept the results for each batch) from all scoring arrays, resulting in memory requirement being decreased by a factor of 2. Correlations between particles in phase‐space sources are taken into account. The only correlations with any significant impact on uncertainty are those introduced by particle recycling. Failure to account for these correlations can result in a significant underestimate of the uncertainty. The previous method of accounting for correlations due to recycling by placing all recycled particles in the same batch did work. Neither the new method nor the batch method take into account correlations between incident particles when a phase‐space source is restarted so one must avoid restarts.
- 15 November 2002
- Published by Wiley in Medical Physics
- Vol. 29 (12) , 2745-2752
Top Cited PapersHistory by history statistical estimators in the BEAM code system
A history by history method for estimating uncertainties has been implemented in the BEAMnrc and DOSXYZnrc codes replacing the method of statistical batches. This method groups scored quantities (e.g., dose) by primary history. When phase‐space sources are used, this method groups incident particles according to the primary histories that generated them. This necessitated adding markers (negative energy) to phase‐space files to indicate the first particle generated by a new primary history. The new method greatly reduces the uncertainty in the uncertainty estimate. The new method eliminates one dimension (which kept the results for each batch) from all scoring arrays, resulting in memory requirement being decreased by a factor of 2. Correlations between particles in phase‐space sources are taken into account. The only correlations with any significant impact on uncertainty are those introduced by particle recycling. Failure to account for these correlations can result in a significant underestimate of the uncertainty. The previous method of accounting for correlations due to recycling by placing all recycled particles in the same batch did work. Neither the new method nor the batch method take into account correlations between incident particles when a phase‐space source is restarted so one must avoid restarts.