Peter Dimbylow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peter Dimbylow has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Akimasa Hirata
Nagoya Institute of Technology
1 shared publication - Choonsik Lee
National Cancer Institute, National Institutes of Health
1 shared publication - R. P. Findlay
Health Protection Agency, Chilton, Oxfordshire, UK
1 shared publication Richard Findlay
Health Protection Agency, Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ , UK
1 shared publicationTomoaki Nagaoka
1 shared publication- Tomoaki Nagaoka
National Institute of Information and Communications Technology, Tokyo, Japan
1 shared publication
Latest Publications
- 1 July 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (14) , 4597-4611
Spherical polar co-ordinate calculations of induced fields in the retina and head for applied magnetic fields at 50 Hz
This paper sets out to explore the effects of voxel resolution, from 2 mm down to 0.1 mm for Cartesian co-ordinates and the differences between Cartesian and spherical polar co-ordinates for a standardized test-bed model of the eye. This model was taken from the work of Yoriyaz et al (2005 Radiat. Prot. Dosim. 115 316-9) who have developed a detailed geometric description of the eye including choroid, retina, sclera, lens, cornea, anterior chamber, vitreous humour and optic nerve for ophthalmic brachytherapy. The spherical co-ordinate model has radial and angular steplengths of 0.1 mm and 0.25 degrees, respectively. The current density averaged over 1 cm(2) and the 99th percentile value of the induced electric field have been calculated in the retina and central nervous system for uniform magnetic fields. The Cartesian co-ordinate calculations proceed in a sequence of grids at 2, 1, 0.5, 0.2 and 0.1 mm resolution with the potentials from the previous calculation at a coarser grid providing the boundary conditions on the finer grid. The 0.2 mm grid provides the boundary conditions for the spherical polar calculations. Comparisons are made with the International Commission on Non-Ionizing Radiation Protection reference levels.
- 1 July 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (14) , 4597-4611
Spherical polar co-ordinate calculations of induced fields in the retina and head for applied magnetic fields at 50 Hz
This paper sets out to explore the effects of voxel resolution, from 2 mm down to 0.1 mm for Cartesian co-ordinates and the differences between Cartesian and spherical polar co-ordinates for a standardized test-bed model of the eye. This model was taken from the work of Yoriyaz et al (2005 Radiat. Prot. Dosim. 115 316-9) who have developed a detailed geometric description of the eye including choroid, retina, sclera, lens, cornea, anterior chamber, vitreous humour and optic nerve for ophthalmic brachytherapy. The spherical co-ordinate model has radial and angular steplengths of 0.1 mm and 0.25 degrees, respectively. The current density averaged over 1 cm(2) and the 99th percentile value of the induced electric field have been calculated in the retina and central nervous system for uniform magnetic fields. The Cartesian co-ordinate calculations proceed in a sequence of grids at 2, 1, 0.5, 0.2 and 0.1 mm resolution with the potentials from the previous calculation at a coarser grid providing the boundary conditions on the finer grid. The 0.2 mm grid provides the boundary conditions for the spherical polar calculations. Comparisons are made with the International Commission on Non-Ionizing Radiation Protection reference levels.
- 16 February 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (5) , 1519-1530
SAR calculations from 20 MHz to 6 GHz in the University of Florida newborn voxel phantom and their implications for dosimetry
This paper presents finite-difference time-domain (FDTD) calculations of SAR in the University of Florida newborn female model. The newborn model is based upon a surface representation of the organs of the body, using non-uniform rational B-spline surfaces (NURBS). The surface model can then be converted into voxels at any resolution required. This flexibility allows the preparation of voxel models at 2, 1 and 0.5 mm to investigate the effect of resolution on dispersion and the choice of algorithms to calculate SAR in the Yee cell as the frequency increases up to 6 GHz. The added advantage of the newborn model is that it is relatively small and so FDTD calculations can be made tractable at a very fine resolution of 0.5 mm. A comparison is made between the calculated external electric fields required to produce the basic restriction on whole-body-averaged SAR and the ICNIRP reference levels for public exposure. At 250 MHz, the whole body resonance, the ICNIRP reference level does not provide a conservative estimate of the whole-body-averaged SAR restriction. The reference level is also breached in the range 700-2450 MHz by all of the irradiation geometries considered.
- 16 February 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (5) , 1519-1530
SAR calculations from 20 MHz to 6 GHz in the University of Florida newborn voxel phantom and their implications for dosimetry
This paper presents finite-difference time-domain (FDTD) calculations of SAR in the University of Florida newborn female model. The newborn model is based upon a surface representation of the organs of the body, using non-uniform rational B-spline surfaces (NURBS). The surface model can then be converted into voxels at any resolution required. This flexibility allows the preparation of voxel models at 2, 1 and 0.5 mm to investigate the effect of resolution on dispersion and the choice of algorithms to calculate SAR in the Yee cell as the frequency increases up to 6 GHz. The added advantage of the newborn model is that it is relatively small and so FDTD calculations can be made tractable at a very fine resolution of 0.5 mm. A comparison is made between the calculated external electric fields required to produce the basic restriction on whole-body-averaged SAR and the ICNIRP reference levels for public exposure. At 250 MHz, the whole body resonance, the ICNIRP reference level does not provide a conservative estimate of the whole-body-averaged SAR restriction. The reference level is also breached in the range 700-2450 MHz by all of the irradiation geometries considered.
- Open Access
- 23 December 2009
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (4) , 532-538
The effects of body posture, anatomy, age and pregnancy on the calculation of induced current densities at 50 Hz
This paper presents calculations of the induced current density in the body at 50 Hz from applied electric and magnetic fields. An extensive ensemble of 25 voxel models has been used to investigate the effects of body posture, anatomy, age and pregnancy. This set includes six adult models, eight child models and seven pregnant female models at various stages of gestation. The four postures investigated in the HPA adult model, NORMAN, were the standard position with the arms at the side, with the arms vertically above the head, the arms horizontally to the side and sitting.
- 23 December 2009
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (4) , 532-538
Open AccessThe effects of body posture, anatomy, age and pregnancy on the calculation of induced current densities at 50 Hz
This paper presents calculations of the induced current density in the body at 50 Hz from applied electric and magnetic fields. An extensive ensemble of 25 voxel models has been used to investigate the effects of body posture, anatomy, age and pregnancy. This set includes six adult models, eight child models and seven pregnant female models at various stages of gestation. The four postures investigated in the HPA adult model, NORMAN, were the standard position with the arms at the side, with the arms vertically above the head, the arms horizontally to the side and sitting.
- 15 April 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (9) , 2755-2767
A comparison of foetal SAR in three sets of pregnant female models
This paper compares the foetal SAR in the HPA hybrid mathematical phantoms with the 26-week foetal model developed at the National Institute of Information and Communications Technology, Tokyo, and the set of 13-, 26- and 38-week boundary representation models produced at Rensselaer Polytechnic Institute. FDTD calculations are performed at a resolution of 2 mm for a plane wave with a vertically aligned electric field incident upon the body from the front, back and two sides from 20 MHz to 3 GHz under isolated conditions. The external electric field values required to produce the ICNIRP public exposure localized restriction of 2 W kg(-1) when averaged over 10 g of the foetus are compared with the ICNIRP reference levels.
- 15 April 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (9) , 2755-2767
A comparison of foetal SAR in three sets of pregnant female models
This paper compares the foetal SAR in the HPA hybrid mathematical phantoms with the 26-week foetal model developed at the National Institute of Information and Communications Technology, Tokyo, and the set of 13-, 26- and 38-week boundary representation models produced at Rensselaer Polytechnic Institute. FDTD calculations are performed at a resolution of 2 mm for a plane wave with a vertically aligned electric field incident upon the body from the front, back and two sides from 20 MHz to 3 GHz under isolated conditions. The external electric field values required to produce the ICNIRP public exposure localized restriction of 2 W kg(-1) when averaged over 10 g of the foetus are compared with the ICNIRP reference levels.
- 30 September 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (20) , 5883-5897
Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms
This paper provides an intercomparison of the HPA male and female models, NORMAN and NAOMI with the National Institute of Information and Communications Technology (NICT) male and female models, TARO and HANAKO. The calculations of the whole-body SAR in these four phantoms were performed at the HPA, at NICT and at the Nagoya Institute of Technology (NIT). These were for a plane wave with a vertically aligned electric field incident upon the front of the body from 30 MHz to 3 GHz for isolated conditions. As well as investigating the general differences through this frequency range, particular emphasis was placed on the assumptions of how dielectric properties are assigned to tissues (particularly skin and fat) and the consequence of using different algorithms for calculating SAR at the higher frequencies.
- 30 September 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (20) , 5883-5897
Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms
This paper provides an intercomparison of the HPA male and female models, NORMAN and NAOMI with the National Institute of Information and Communications Technology (NICT) male and female models, TARO and HANAKO. The calculations of the whole-body SAR in these four phantoms were performed at the HPA, at NICT and at the Nagoya Institute of Technology (NIT). These were for a plane wave with a vertically aligned electric field incident upon the front of the body from 30 MHz to 3 GHz for isolated conditions. As well as investigating the general differences through this frequency range, particular emphasis was placed on the assumptions of how dielectric properties are assigned to tissues (particularly skin and fat) and the consequence of using different algorithms for calculating SAR at the higher frequencies.
- 9 April 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (9) , 2277-2289
Calculated SAR distributions in a human voxel phantom due to the reflection of electromagnetic fields from a ground plane between 65 MHz and 2 GHz
If an electromagnetic field is incident normally onto a perfectly conducting ground plane, the field is reflected back into the domain. This produces a standing wave above the ground plane. If a person is present within the domain, absorption of the field in the body may cause problems regarding compliance with electromagnetic guidelines. To investigate this, the whole-body averaged specific energy absorption rate (SAR), localised SAR and ankle currents in the voxel model NORMAN have been calculated for a variety of these exposures under grounded conditions. The results were normalised to the spatially averaged field, a technique used to determine a mean value for comparison with guidelines when the field varies along the height of the body. Additionally, the external field values required to produce basic restrictions for whole-body averaged SAR have been calculated. It was found that in all configurations studied, the ICNIRP reference levels and IEEE MPEs provided a conservative estimate of these restrictions.
- 9 April 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (9) , 2277-2289
Calculated SAR distributions in a human voxel phantom due to the reflection of electromagnetic fields from a ground plane between 65 MHz and 2 GHz
If an electromagnetic field is incident normally onto a perfectly conducting ground plane, the field is reflected back into the domain. This produces a standing wave above the ground plane. If a person is present within the domain, absorption of the field in the body may cause problems regarding compliance with electromagnetic guidelines. To investigate this, the whole-body averaged specific energy absorption rate (SAR), localised SAR and ankle currents in the voxel model NORMAN have been calculated for a variety of these exposures under grounded conditions. The results were normalised to the spatially averaged field, a technique used to determine a mean value for comparison with guidelines when the field varies along the height of the body. Additionally, the external field values required to produce basic restrictions for whole-body averaged SAR have been calculated. It was found that in all configurations studied, the ICNIRP reference levels and IEEE MPEs provided a conservative estimate of these restrictions.
- 26 October 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (22) , 6639-6649
Whole-body-averaged SAR from 50 MHz to 4 GHz in the University of Florida child voxel phantoms
The University of Florida (UF) Series B paediatric phantoms were developed for medical and radiation protection photon dosimetry. The series includes a 9 month male, a 4 year female, an 8 year female, an 11 year male and a 14 year male. In this paper they have been adapted to calculate the whole-body-averaged specific energy absorption rate (SAR) in children for plane wave exposure from 50 MHz to 4 GHz. The consideration of children is important in the application of the ICNIRP public exposure reference levels above approximately 1 GHz. The uniformly scaled models of NORMAN and NAOMI suggest that the ICNIRP reference level does not provide a conservative estimate of the whole-body-averaged SAR restriction for 5 year and 1 year old models. Comparison is made with the previous linearly scaled versions of NORMAN and NAOMI for calculations at 2 mm resolution. Further FDTD calculations were performed at resolutions of 1 and 0.7 mm above 900 MHz to elucidate the effects of grid resolution on SAR. A comparison is made between the calculated external electric fields required to produce the basic restriction on the whole-body-averaged SAR and the ICNIRP reference levels for public exposure.
- 26 October 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (22) , 6639-6649
Whole-body-averaged SAR from 50 MHz to 4 GHz in the University of Florida child voxel phantoms
The University of Florida (UF) Series B paediatric phantoms were developed for medical and radiation protection photon dosimetry. The series includes a 9 month male, a 4 year female, an 8 year female, an 11 year male and a 14 year male. In this paper they have been adapted to calculate the whole-body-averaged specific energy absorption rate (SAR) in children for plane wave exposure from 50 MHz to 4 GHz. The consideration of children is important in the application of the ICNIRP public exposure reference levels above approximately 1 GHz. The uniformly scaled models of NORMAN and NAOMI suggest that the ICNIRP reference level does not provide a conservative estimate of the whole-body-averaged SAR restriction for 5 year and 1 year old models. Comparison is made with the previous linearly scaled versions of NORMAN and NAOMI for calculations at 2 mm resolution. Further FDTD calculations were performed at resolutions of 1 and 0.7 mm above 900 MHz to elucidate the effects of grid resolution on SAR. A comparison is made between the calculated external electric fields required to produce the basic restriction on the whole-body-averaged SAR and the ICNIRP reference levels for public exposure.