Thomas L. Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas L. Miller has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Thomas H. Shaffer
Nemours Research Lung Center, Alfred I. DuPont Hospital for Children, Wilmington, DE 19803, USA
6 shared publicationsAaron Chidekel
Nemours Research Lung Center, Alfred I. duPont Hospital for Children, Wilmington
2 shared publicationsAllison R. Altman
Nemours Research Lung Center, Alfred I. DuPont Hospital for Children, Wilmington, DE 19803, USA
2 shared publicationsSuzanne M. Touch
2 shared publicationsCharles Palmer
Department of Pediatrics, Division of Newborn Medicine, Penn State Children's Hospital, Hershey, Pennsylvania
1 shared publicationClifford J. Singhaus
1 shared publication
Latest Publications
- 1 August 2008
- Published by Springer Nature in Pediatric Research
- Vol. 64 (2) , 154-158
KL4-Surfactant (Lucinactant) Protects Human Airway Epithelium from Hyperoxia
- 1 August 2008
- Published by Springer Nature in Pediatric Research
- Vol. 64 (2) , 154-158
KL4-Surfactant (Lucinactant) Protects Human Airway Epithelium from Hyperoxia
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40 (7) , 1615-1621
An ultrasound imaging method for in vivo tracheal bulk and Young's moduli of elasticity
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40 (7) , 1615-1621
An ultrasound imaging method for in vivo tracheal bulk and Young's moduli of elasticity
- 22 November 2006
- Published by Wiley in Pediatric Pulmonology
- Vol. 42 (2) , 141-149
Sequential alterations of tracheal mechanical properties in the neonatal lamb: Effect of mechanical ventilation
Alterations in neonatal airway mechanics resulting from ventilatory therapies are implicated in airway collapse and chronic disease. Quantifying the functional impact of mechanical ventilation (MV) on the neonatal airway and elucidating the time course of these changes will support development of protective therapies. The objective of this study was to test the hypothesis that conventional MV would result in decreased static and dynamic elastance of an isolated tracheal segment and thinning of the muscle (trachealis) region of the tracheal wall in a time dependent manner. Tracheal segments were isolated in newborn lambs spontaneously breathing through the distal trachea; segments were MV (n = 7; PIP/PEEP = 35/5 cmH2O; 40 breaths/min) or instrumented, non‐ventilated (SHAM; n = 7; PIP/PEEP = 0/0 cmH2O) for 4 hr. At baseline and hourly, tracheal segments were filled with saline, and static pressure–volume curves were constructed as the pressure response to stepwise volume infusions. Then, cross‐sectional ultrasound images were captured at 0 cmH2O on SHAM, and at 0 cmH2O, peak inspiratory pressure (PIP) and positive end expiratory pressure (PEEP), on MV tracheae for subsequent dimensional analysis. Tracheal elasticity indices were derived from static pressure–volume data, and during dynamic ventilation using ultrasound images to calculate the stress–strain relationships. Over 4 hr of MV, tracheal internal diameter (ID) increased (14%; P < 0.05). Markers of tracheal mechanical properties indicated a decrease in elasticity under both static (bulk modulus; 28%; P < 0.05) and dynamic (elastic modulus; 282 %; P < 0.05) conditions, indicating a significant alteration in elastic components. No time dependent changes were identified in dimensions or mechanical properties in the SHAM group. Conclusions: MV results in dimensional alterations that increased anatomical dead space and reduced static and dynamic elastance of the neonatal trachea. Pediatr Pulmonol. 2007; 42:141–149.
- 22 November 2006
- Published by Wiley in Pediatric Pulmonology
- Vol. 42 (2) , 141-149
Sequential alterations of tracheal mechanical properties in the neonatal lamb: Effect of mechanical ventilation
Alterations in neonatal airway mechanics resulting from ventilatory therapies are implicated in airway collapse and chronic disease. Quantifying the functional impact of mechanical ventilation (MV) on the neonatal airway and elucidating the time course of these changes will support development of protective therapies. The objective of this study was to test the hypothesis that conventional MV would result in decreased static and dynamic elastance of an isolated tracheal segment and thinning of the muscle (trachealis) region of the tracheal wall in a time dependent manner. Tracheal segments were isolated in newborn lambs spontaneously breathing through the distal trachea; segments were MV (n = 7; PIP/PEEP = 35/5 cmH2O; 40 breaths/min) or instrumented, non‐ventilated (SHAM; n = 7; PIP/PEEP = 0/0 cmH2O) for 4 hr. At baseline and hourly, tracheal segments were filled with saline, and static pressure–volume curves were constructed as the pressure response to stepwise volume infusions. Then, cross‐sectional ultrasound images were captured at 0 cmH2O on SHAM, and at 0 cmH2O, peak inspiratory pressure (PIP) and positive end expiratory pressure (PEEP), on MV tracheae for subsequent dimensional analysis. Tracheal elasticity indices were derived from static pressure–volume data, and during dynamic ventilation using ultrasound images to calculate the stress–strain relationships. Over 4 hr of MV, tracheal internal diameter (ID) increased (14%; P < 0.05). Markers of tracheal mechanical properties indicated a decrease in elasticity under both static (bulk modulus; 28%; P < 0.05) and dynamic (elastic modulus; 282 %; P < 0.05) conditions, indicating a significant alteration in elastic components. No time dependent changes were identified in dimensions or mechanical properties in the SHAM group. Conclusions: MV results in dimensional alterations that increased anatomical dead space and reduced static and dynamic elastance of the neonatal trachea. Pediatr Pulmonol. 2007; 42:141–149.
- 1 October 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 118 (4) , e1264-e1267
Pulmonary Function Assessment in an Infant With Barnes Syndrome: Proactive Evaluation for Surgical Intervention
Our aim for this study was to report pulmonary mechanics in a neonate with a severe case of Barnes syndrome, a rare form of thoracolaryngopelvic dysplasia, and to use these data to guide ventilatory support and serve as a presurgical screening tool. A comprehensive pulmonary function evaluation was performed on a 36-day-old patient with Barnes syndrome who was being mechanically ventilated because of severe pulmonary distress secondary to thoracic dystrophy. The measurements consisted of respiratory volumes including functional residual capacity, ventilatory mechanics including compliance and resistance, and thoracoabdominal synchrony. Chest wall compliance was 64% below normal, and the thoracoabdominal motion was indicative of predominantly abdominal displacement during inspiratory breaths. The lungs were functioning at a low functional residual capacity, resulting in low lung compliance and increased pulmonary resistance. As a result of the evaluation, the patient was recommended for lateral thoracic expansion surgery and the ventilatory management was adjusted to focus on end-distending pressure support.
- 1 October 2006
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 118 (4) , e1264-e1267
Pulmonary Function Assessment in an Infant With Barnes Syndrome: Proactive Evaluation for Surgical Intervention
Our aim for this study was to report pulmonary mechanics in a neonate with a severe case of Barnes syndrome, a rare form of thoracolaryngopelvic dysplasia, and to use these data to guide ventilatory support and serve as a presurgical screening tool. A comprehensive pulmonary function evaluation was performed on a 36-day-old patient with Barnes syndrome who was being mechanically ventilated because of severe pulmonary distress secondary to thoracic dystrophy. The measurements consisted of respiratory volumes including functional residual capacity, ventilatory mechanics including compliance and resistance, and thoracoabdominal synchrony. Chest wall compliance was 64% below normal, and the thoracoabdominal motion was indicative of predominantly abdominal displacement during inspiratory breaths. The lungs were functioning at a low functional residual capacity, resulting in low lung compliance and increased pulmonary resistance. As a result of the evaluation, the patient was recommended for lateral thoracic expansion surgery and the ventilatory management was adjusted to focus on end-distending pressure support.
- 1 June 2006
- Published by S. Karger AG in Neonatology
- Vol. 89 (4) , 236-243
Expression of Matrix Metalloproteinases 2, 7 and 9, and Their Tissue Inhibitors 1 and 2, in Developing Rabbit Tracheae
Background: Structural changes in the developing conducting airway impact the rigidity of the airway, altering the airway’s ability to sustain its shape during ventilation. The developmental changes in airway compliance oppose the changes in compliance of the developing lung; thus the expression profiles of matrix modeling proteins likely are also opposite in these developing organs. Objectives: To determine the profiles of matrix metalloproteinases (MMPs) -2, -7, and -9 and tissue inhibitors (TIMPs) -1 and -2 in the developing trachea and test the hypothesis these profiles would contrast those previously reported for the lung. Methods: Rabbits tracheae were harvested at 21 days of gestation, 3 and 17 days postgestation and at adulthood. Tissue homogenates were analyzed by substrate zymography for the activity of MMPs, and reverse zymography for TIMPs. Immunostainings on neonatal lamb tracheal rings were used to localize MMP-2 and 9. Results: Analysis revealed an age-dependent decrease in total MMP-2 quantity and the ratio of active to latent forms. TIMP-2 shows a time-dependent increase throughout airway development. Total MMP-9 and TIMP-1 quantities were unchanged across these ages, although MMP-9 protein was found predominantly in its latent form during development and predominantly in its active form during adulthood. Respiratory epithelial cells reacted positive for both MMP-2 and 9 and trachealis muscle fibers were positive for MMP-2. No MMP-7 expression was identified in the rabbit airway. Conclusions: The opposing developmental patterns in MMP-2 expression between the airway and lung lead to speculation regarding the role of MMP-2 activity on changes in organ compliance.
- 1 June 2006
- Published by S. Karger AG in Neonatology
- Vol. 89 (4) , 236-243
Expression of Matrix Metalloproteinases 2, 7 and 9, and Their Tissue Inhibitors 1 and 2, in Developing Rabbit Tracheae
Background: Structural changes in the developing conducting airway impact the rigidity of the airway, altering the airway’s ability to sustain its shape during ventilation. The developmental changes in airway compliance oppose the changes in compliance of the developing lung; thus the expression profiles of matrix modeling proteins likely are also opposite in these developing organs. Objectives: To determine the profiles of matrix metalloproteinases (MMPs) -2, -7, and -9 and tissue inhibitors (TIMPs) -1 and -2 in the developing trachea and test the hypothesis these profiles would contrast those previously reported for the lung. Methods: Rabbits tracheae were harvested at 21 days of gestation, 3 and 17 days postgestation and at adulthood. Tissue homogenates were analyzed by substrate zymography for the activity of MMPs, and reverse zymography for TIMPs. Immunostainings on neonatal lamb tracheal rings were used to localize MMP-2 and 9. Results: Analysis revealed an age-dependent decrease in total MMP-2 quantity and the ratio of active to latent forms. TIMP-2 shows a time-dependent increase throughout airway development. Total MMP-9 and TIMP-1 quantities were unchanged across these ages, although MMP-9 protein was found predominantly in its latent form during development and predominantly in its active form during adulthood. Respiratory epithelial cells reacted positive for both MMP-2 and 9 and trachealis muscle fibers were positive for MMP-2. No MMP-7 expression was identified in the rabbit airway. Conclusions: The opposing developmental patterns in MMP-2 expression between the airway and lung lead to speculation regarding the role of MMP-2 activity on changes in organ compliance.
- 27 January 2005
- Published by Wiley in Pediatric Pulmonology
- Vol. 39 (6) , 512-520
Neonatal chest wall suspension splint: A novel and noninvasive method for support of lung volume
Surfactant and musculoskeletal immaturity results in lower compliance of the lung relative to the chest wall, with clinical manifestations of low lung volume, marked chest wall retractions (CWR), and thoracoabdominal asynchrony. Inspiratory efforts are dissipated on distorting the chest wall inward rather than recruiting lung volumes. The current study tests the hypothesis that a novel neonatal chest wall suspension splint (SP), designed to provide stability to the compliant chest wall, would reduce inspiratory chest wall retractions and improve lung volumes. Nine preterm infants (29 ± 1 SE weeks of gestation; 1.59 ± 0.27 SE kg study weight) were studied at 16 ± 5 SE days of life at baseline (BL) and following application of the front plate (FP) and the full SP (Hug n Snug™ Neonatal Chest Splint, Respironics, Inc.). Phase angle of thoracoabdominal motion, CWR, functional residual capacity (FRC), and pulmonary function were evaluated during spontaneous breathing. Compared to BL, there was a significant decrease in anterior CWR (2.21 ± 0.91 SE vs. 0.25 ± 0.09 SE mm; P < 0.05), an increase in FRC (16.6 ± 2.8 SE vs. 27.8 ± 5.5 SE ml/kg; P < 0.05) and tidal volume (4.8 ± 1.5 SE vs. 7.3 ± 1.4 SE ml/kg; P < 0.05), minimal effect on pulmonary compliance (1.98 ± 0.50 SE vs. 1.72 ± 0.30 SE ml/cmH2O/kg), and a trend for a decrease in phase angle (128.4 ± 10.9 SE vs. 111.8 ± 19.3 SE) with the application of the splint. FRC correlated inversely with severity of CWR across all conditions (P < 0.05, r = −0.68). Phase angle was directly correlated to anterior CWR (r = 0.72; P < 0.05) and correlated inversely with FRC (P < 0.005; r = −0.56). We speculate that by improving CW stability, the use of this splint may reduce the energetic requirements of breathing and, potentially, the need for more invasive ventilatory support in the neonate. Pediatr Pulmonol.
- 27 January 2005
- Published by Wiley in Pediatric Pulmonology
- Vol. 39 (6) , 512-520
Neonatal chest wall suspension splint: A novel and noninvasive method for support of lung volume
Surfactant and musculoskeletal immaturity results in lower compliance of the lung relative to the chest wall, with clinical manifestations of low lung volume, marked chest wall retractions (CWR), and thoracoabdominal asynchrony. Inspiratory efforts are dissipated on distorting the chest wall inward rather than recruiting lung volumes. The current study tests the hypothesis that a novel neonatal chest wall suspension splint (SP), designed to provide stability to the compliant chest wall, would reduce inspiratory chest wall retractions and improve lung volumes. Nine preterm infants (29 ± 1 SE weeks of gestation; 1.59 ± 0.27 SE kg study weight) were studied at 16 ± 5 SE days of life at baseline (BL) and following application of the front plate (FP) and the full SP (Hug n Snug™ Neonatal Chest Splint, Respironics, Inc.). Phase angle of thoracoabdominal motion, CWR, functional residual capacity (FRC), and pulmonary function were evaluated during spontaneous breathing. Compared to BL, there was a significant decrease in anterior CWR (2.21 ± 0.91 SE vs. 0.25 ± 0.09 SE mm; P < 0.05), an increase in FRC (16.6 ± 2.8 SE vs. 27.8 ± 5.5 SE ml/kg; P < 0.05) and tidal volume (4.8 ± 1.5 SE vs. 7.3 ± 1.4 SE ml/kg; P < 0.05), minimal effect on pulmonary compliance (1.98 ± 0.50 SE vs. 1.72 ± 0.30 SE ml/cmH2O/kg), and a trend for a decrease in phase angle (128.4 ± 10.9 SE vs. 111.8 ± 19.3 SE) with the application of the splint. FRC correlated inversely with severity of CWR across all conditions (P < 0.05, r = −0.68). Phase angle was directly correlated to anterior CWR (r = 0.72; P < 0.05) and correlated inversely with FRC (P < 0.005; r = −0.56). We speculate that by improving CW stability, the use of this splint may reduce the energetic requirements of breathing and, potentially, the need for more invasive ventilatory support in the neonate. Pediatr Pulmonol.
- 3 September 2004
- Published by Wiley in Pediatric Pulmonology
- Vol. 38 (5) , 386-395
Tracheal gas insufflation‐augmented continuous positive airway pressure in a spontaneously breathing model of neonatal respiratory distress
Respiratory distress syndrome (RDS) in neonates is characterized by labored breathing and poor gas exchange, often requiring ventilatory support. Continuous positive airway pressure (CPAP) is a preferred intervention to support spontaneous ventilatory efforts by sustaining lung volume recruitment, while it prevents derecruitment during exhalation by maintaining end‐expiratory pressure. However, CO2 retention during CPAP often results in the need for mechanical ventilation. Since tracheal gas insufflation (TGI) promotes CO2 elimination by reducing prosthetic dead space, we hypothesized that TGI used with CPAP may reduce the need for more invasive therapies. The objective of this study was to evaluate the physiologic effect of TGI with CPAP in a spontaneously breathing model of acute lung injury with respect to gas exchange and pulmonary mechanics. Nineteen spontaneously breathing neonatal pigs (2.4 ± 0.4 kg) were anesthetized, sedated, instrumented, and placed on CPAP at 5 cmH2O. All piglets were injured with intravenous oleic acid (0.08 ml/kg), and then randomized to receive CPAP with TGI (TGI; n = 9) or CPAP alone (control; n = 10). FiO2 was titrated at 0.05 every 15 min during the protocol to maintain SaO2 > 93%. Vital signs, arterial blood gases, pulmonary mechanics, and thoracoabdominal motion (TAM) were evaluated 30 min after injury and at 1‐hr intervals for 4 hr. Following the 4‐hr measurement, the piglets were sacrificed and the lungs were grossly examined. After initiation of treatment, we found that the PaCO2 was lower (33.1 ± 5.0 vs. 47.0 ± 10.3 mmHg; P < 0.01), while the oxygenation indices were greater (PaO2, SaO2, a/A ratio; P < 0.01) in the TGI group than with control animals. Subsequently, the pH was greater (7.45 ± 0.08 vs. 7.36 ± 0.08; P < 0.01) and closer to baseline values with TGI. By 4 hr, the FiO2 was titrated lower (0.37 ± 0.06 vs. 0.49 ± 0.15; P < 0.05) and ventilation was accomplished with a lower minute ventilation (MV) in the TGI group than in the control group (445 ± 113 vs. 581 ± 223 ml/kg/min; P < 0.01). Respiratory compliance was greater with TGI than control (0.76 ± 0.13 vs. 0.63 ± 0.11 ml/cmH2O/kg; P < 0.01), whereas resistance and TAM were similar between groups. We conclude that the use of TGI with CPAP in the treatment of RDS results in improved gas exchange and pulmonary mechanics. As such, TGI‐augmented CPAP may prevent infants from requiring more invasive ventilation by reducing CO2 retention.
- 3 September 2004
- Published by Wiley in Pediatric Pulmonology
- Vol. 38 (5) , 386-395
Tracheal gas insufflation‐augmented continuous positive airway pressure in a spontaneously breathing model of neonatal respiratory distress
Respiratory distress syndrome (RDS) in neonates is characterized by labored breathing and poor gas exchange, often requiring ventilatory support. Continuous positive airway pressure (CPAP) is a preferred intervention to support spontaneous ventilatory efforts by sustaining lung volume recruitment, while it prevents derecruitment during exhalation by maintaining end‐expiratory pressure. However, CO2 retention during CPAP often results in the need for mechanical ventilation. Since tracheal gas insufflation (TGI) promotes CO2 elimination by reducing prosthetic dead space, we hypothesized that TGI used with CPAP may reduce the need for more invasive therapies. The objective of this study was to evaluate the physiologic effect of TGI with CPAP in a spontaneously breathing model of acute lung injury with respect to gas exchange and pulmonary mechanics. Nineteen spontaneously breathing neonatal pigs (2.4 ± 0.4 kg) were anesthetized, sedated, instrumented, and placed on CPAP at 5 cmH2O. All piglets were injured with intravenous oleic acid (0.08 ml/kg), and then randomized to receive CPAP with TGI (TGI; n = 9) or CPAP alone (control; n = 10). FiO2 was titrated at 0.05 every 15 min during the protocol to maintain SaO2 > 93%. Vital signs, arterial blood gases, pulmonary mechanics, and thoracoabdominal motion (TAM) were evaluated 30 min after injury and at 1‐hr intervals for 4 hr. Following the 4‐hr measurement, the piglets were sacrificed and the lungs were grossly examined. After initiation of treatment, we found that the PaCO2 was lower (33.1 ± 5.0 vs. 47.0 ± 10.3 mmHg; P < 0.01), while the oxygenation indices were greater (PaO2, SaO2, a/A ratio; P < 0.01) in the TGI group than with control animals. Subsequently, the pH was greater (7.45 ± 0.08 vs. 7.36 ± 0.08; P < 0.01) and closer to baseline values with TGI. By 4 hr, the FiO2 was titrated lower (0.37 ± 0.06 vs. 0.49 ± 0.15; P < 0.05) and ventilation was accomplished with a lower minute ventilation (MV) in the TGI group than in the control group (445 ± 113 vs. 581 ± 223 ml/kg/min; P < 0.01). Respiratory compliance was greater with TGI than control (0.76 ± 0.13 vs. 0.63 ± 0.11 ml/cmH2O/kg; P < 0.01), whereas resistance and TAM were similar between groups. We conclude that the use of TGI with CPAP in the treatment of RDS results in improved gas exchange and pulmonary mechanics. As such, TGI‐augmented CPAP may prevent infants from requiring more invasive ventilation by reducing CO2 retention.