TGTodd M. Gudausky

Todd M. Gudausky

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Todd M. Gudausky has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Allison Divanovic

    Divisions of Cardiology and

    1 shared publication
  • Andrew N. Pelech

    Medical College of Wisconsin, The Herma Heart Center, Children’s Hospital of Wisconsin

    1 shared publication
  • Catherine L. Dent

    Department of Cardiology, Cincinnati Children's Hospital Medical Center, University of Cincinnati School of Medicine, 3333 Burnet Ave, Cincinnati, Ohio 45229, USA

    1 shared publication
  • Edward Kim

    Divisions of Cardiology and

    1 shared publication
  • Gail Stendahl

    Medical College of Wisconsin, The Herma Heart Center, Children’s Hospital of Wisconsin

    1 shared publication
  • Jeffrey Pearl

    Cardiothoracic Surgery, Cincinnati Children’s Hospital Medical Center, Cincinnati, Ohio, USA

    1 shared publication

Latest Publications

  • Dual-Axis Rotational Coronary Angiography: A New Technique for Detecting Graft Coronary Vasculopathy in Pediatric Heart Transplant Recipients

    by Todd M. Gudausky, Andrew N. Pelech, Gail Stendahl, Kathryn Tillman, Judy Mattice, Stuart Berger, Steven Zangwill

    Annual surveillance coronary angiograpyhy to screen for graft coronary vasculopathy is routine practice after orthotopic heart transplantation. Traditionally, this is performed with direct coronary angiography using static single-plane or biplane angiography. Recently, technological advances have made it possible to perform dual-axis rotational coronary angiography (RA). This technique differs from standard static single-plane or biplane angiography in that a single detector is preprogrammed to swing through a complex 80° arc during a single injection. It has the advantage of providing a perspective of the vessels from a full arc of images rather than from one or two static images per contrast injection. The current study evaluated two coronary angiography techniques used consecutively at a single center to evaluate pediatric heart transplant recipients for graft coronary vasculopathy. A total of 23 patients underwent routine coronary angiography using both biplane static coronary angiography (BiP) and RA techniques at the Children’s Hospital of Wisconsin from February 2009 to September 2010. Demographic and procedure data were collected from each procedure and analyzed for significance utilizing a Wilcoxon rank sum test. No significant demographic or procedural differences between the BiP and the RA procedures were noted. Specific measures of radiation dose including fluoroscopy time and dose area product were similar among the imaging techniques. The findings show that RA can be performed safely and reproducibly in pediatric heart transplant recipients. Compared with standard BiP, RA does not increase radiation exposure or contrast use and in our experience has provided superior angiographic imaging for the evaluation of graft coronary vasculopathy.


  • Comparison of two transcatheter device strategies for occlusion of the patent ductus arteriosus

    by Todd M. Gudausky, Russel Hirsch, Philip R. Khoury, Robert H. Beekman

    Objectives: The present study evaluates two transcatheter closure strategies utilized at a single center and makes recommendations for device selection when occluding the patent ductus arteriosus. Background: A variety of devices are available for transcatheter closure of the patent ductus arteriosus (PDA) but no guidelines exist to guide operator device choice. Methods: A total of 132 patients underwent attempted transcatheter PDA closure utilizing one of two consecutive closure strategies between January 2000 and June 2005. Strategy A (n = 64; January 2000–May 2003) utilized Gianturco coils only. Strategy B (n = 68; June 2003–June 2005) utilized a single Gianturco coil for the PDA with a minimal diameter ≤1 mm (n = 28) or an Amplatzer Duct Occluder (ADO) if the PDA diameter exceeded 1 mm (n = 40). Success was defined as complete occlusion on a follow up echocardiogram. Results: 58 of 64 (90.6%) patients treated utilizing strategy A had successful coil implantation. 68 of 68 (100%) patients treated utilizing strategy B had successful coil/device implantation. At follow up echocardiography, 32 of 44 (72.7%) strategy A patients had complete ductal closure, as compared with 57 of 58 (98.3%) strategy B patients (P < 0.0001). Stepwise logistic regression analysis identified closure strategy as the most powerful predictor of procedural success (OR = 85.9; CI 5.6–9.99). Conclusions: A transcatheter PDA closure strategy consisting of a single Gianturco coil for PDA ≤ 1 mm or an ADO for larger sized PDA (strategy B) achieves superior outcomes compared to the use of coils alone.


  • Open-chest Epicardial Approach to Transcatheter Pulmonary Artery Stenting Following Heart Transplantation in an Infant

    by Todd M. Gudausky, Jeffrey Pearl, Catherine L. Dent, Edward Kim, Allison Divanovic, Robert L. Spicer, Robert H. Beekman

    We describe an open-chest epicardial approach to transcatheter pulmonary artery stenting in a critically ill infant following heart transplantation. Technical considerations, indications, and feasibility are discussed. This case provides another example of the value of a "hybrid" approach (combining surgery and interventional cardiology) to complex congenital heart disease.