Sucbei Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sucbei Moon has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Dug Young Kim
Yonsei University
2 shared publications Jangbeom Lee
Department of Physics, Kookmin University, Seoul, 136-702, South Korea
2 shared publicationsJunyoung Hwang
Department of Physics, Kookmin University, Seoul, Republic of Korea
2 shared publicationsZhongping Chen
Department of Cogno Mechatronics Engineering, WCU Program, Pusan National University, Busan 609-735, South Korea
2 shared publicationsAhyeon Hur
1 shared publicationChang-Seok Kim
Department of Cogno Mechatronics Engineering, WCU Program, Pusan National University, Busan 609-735, South Korea
1 shared publication
Latest Publications
- Open Access
- 4 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 30337
Non-rotational multi-channel endoscopic OCT for trajectory-resolved imaging in stereotactic brain biopsy
- 4 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 30337
Open AccessNon-rotational multi-channel endoscopic OCT for trajectory-resolved imaging in stereotactic brain biopsy
- 31 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (22) , 47455-47469
Superchromatic null lens for chromatic depth imaging
Chromatic depth imaging (CDI) is a depth-sensitive imaging mode, performed in a high level of chromatic aberration (CA) by which the imaging system produces wavelength-dependent foci along the depth. The CDI system demands a high-CA objective lens but with a minimal level of monochromatic aberrations for the best image quality. Here, we present a method of obtaining a suitable high-CA objective by utilizing a dispersive null lens of virtually zero refractive power. The so-called superchromatic null lens consists of cemented multiple elements in alternation of dispersion characteristics. Our superchromat is a compact component that can be easily added to a conventional imaging system for the implementation of CDI. With a low-cost RGB color image sensor, depth-sensitive imaging capabilities are easily obtained from the RGB image channels by the characteristic focal differences produced by our superchromat. In our study, an optimized lens design of our superchromat was found for boosted CA and suppressed overall aberration. Its imaging performance was validated through computer modeling and experimental evaluations. Finally, by attaching our superchromat on the objective in practice, an ordinary photographic camera and a conventional phase-contrast microscope were successfully reconfigured for extended depth of field and depth sensing. This report includes the basic theory, design optimization, and the performance evaluation of our superchromat, as well as the application techniques for cost-effective CDI implementations.
- 31 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (22) , 47455-47469
Superchromatic null lens for chromatic depth imaging
Chromatic depth imaging (CDI) is a depth-sensitive imaging mode, performed in a high level of chromatic aberration (CA) by which the imaging system produces wavelength-dependent foci along the depth. The CDI system demands a high-CA objective lens but with a minimal level of monochromatic aberrations for the best image quality. Here, we present a method of obtaining a suitable high-CA objective by utilizing a dispersive null lens of virtually zero refractive power. The so-called superchromatic null lens consists of cemented multiple elements in alternation of dispersion characteristics. Our superchromat is a compact component that can be easily added to a conventional imaging system for the implementation of CDI. With a low-cost RGB color image sensor, depth-sensitive imaging capabilities are easily obtained from the RGB image channels by the characteristic focal differences produced by our superchromat. In our study, an optimized lens design of our superchromat was found for boosted CA and suppressed overall aberration. Its imaging performance was validated through computer modeling and experimental evaluations. Finally, by attaching our superchromat on the objective in practice, an ordinary photographic camera and a conventional phase-contrast microscope were successfully reconfigured for extended depth of field and depth sensing. This report includes the basic theory, design optimization, and the performance evaluation of our superchromat, as well as the application techniques for cost-effective CDI implementations.
- 18 April 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (5) , 1960-1970
Single-shot full-field optical coherence tomography with a single polarization camera
We present a novel implementation technique of single-shot full-field optical coherence tomography (S-FF-OCT) by utilizing a single-sensor polarization camera. S-FF-OCT is capable of acquiring interference image information in a single camera capture with a short signal integration time, which makes it particularly advantageous for tomographic imaging of fast-moving objects or samples under environmental vibrations. For a simple and compact system of S-FF-OCT, we developed a polarization-channeled detection scheme of interference based on a Linnik interferometer and a commercial polarization camera. The phase-shifted quadrature components of the polarized interferograms are generated by the polarization optics and can be analyzed using the polarization camera. A single capture of the interferograms yields an en-face OCT image with the help of the coherence gating effect. In this study, the imaging performance of our S-FF-OCT is validated by delineating moving objects and living biological specimens under ambient vibrations, thereby demonstrating its practical application potential for FF-OCT imaging in situ.
- 18 April 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (5) , 1960-1970
Single-shot full-field optical coherence tomography with a single polarization camera
We present a novel implementation technique of single-shot full-field optical coherence tomography (S-FF-OCT) by utilizing a single-sensor polarization camera. S-FF-OCT is capable of acquiring interference image information in a single camera capture with a short signal integration time, which makes it particularly advantageous for tomographic imaging of fast-moving objects or samples under environmental vibrations. For a simple and compact system of S-FF-OCT, we developed a polarization-channeled detection scheme of interference based on a Linnik interferometer and a commercial polarization camera. The phase-shifted quadrature components of the polarized interferograms are generated by the polarization optics and can be analyzed using the polarization camera. A single capture of the interferograms yields an en-face OCT image with the help of the coherence gating effect. In this study, the imaging performance of our S-FF-OCT is validated by delineating moving objects and living biological specimens under ambient vibrations, thereby demonstrating its practical application potential for FF-OCT imaging in situ.
- 10 December 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (1) , 115-125
Light-sheet microscopy enabled by a miniaturized plane illuminator
We present a implementation method of light-sheet microscopy utilizing a highly miniaturized device that produces light-sheet illumination while immersed in the sample container. Our miniaturized plane illuminator (MPI) internally equips a two-axis beam-scanning mechanism based on a magnetostatically driven optical fiber cantilever. A light sheet is produced by fast scanning of the focused beam in an axis while the illumination plane can move in the other axis for positioning and 3D imaging. Our MPI device is so compact in a 1.5 mm-thick needle form that it can be conveniently placed in the right vicinity of the imaging sample. Because the illumination is directly given in the sample-surrounding medium, a great deal of operational flexibility is obtained with an uncompromised beam quality. We could build a light-sheet microscopy system with a conventional inverted microscope frame by attaching our MPI upgrade kit as an add-on module. In this study, the optical and electromechanical characteristics of our MPI device were carefully investigated. As well, light-sheet microscopy imaging of various samples was performed to validate the practical power of our technique. We found our MPI can provide a low-cost and easy-to-use imaging mode, and make the light-sheet microscopy more available in various applications.
- 10 December 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (1) , 115-125
Light-sheet microscopy enabled by a miniaturized plane illuminator
We present a implementation method of light-sheet microscopy utilizing a highly miniaturized device that produces light-sheet illumination while immersed in the sample container. Our miniaturized plane illuminator (MPI) internally equips a two-axis beam-scanning mechanism based on a magnetostatically driven optical fiber cantilever. A light sheet is produced by fast scanning of the focused beam in an axis while the illumination plane can move in the other axis for positioning and 3D imaging. Our MPI device is so compact in a 1.5 mm-thick needle form that it can be conveniently placed in the right vicinity of the imaging sample. Because the illumination is directly given in the sample-surrounding medium, a great deal of operational flexibility is obtained with an uncompromised beam quality. We could build a light-sheet microscopy system with a conventional inverted microscope frame by attaching our MPI upgrade kit as an add-on module. In this study, the optical and electromechanical characteristics of our MPI device were carefully investigated. As well, light-sheet microscopy imaging of various samples was performed to validate the practical power of our technique. We found our MPI can provide a low-cost and easy-to-use imaging mode, and make the light-sheet microscopy more available in various applications.
- 20 April 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (9) , 14677-14685
Use of nanosecond excitation pulses in fluorescence lifetime measurement via phasor analysis
We investigated the possibility of using long excitation pulses in fluorescence lifetime imaging microscopy (FLIM) using phasor analysis. It has long been believed that the pulse width of an excitation laser must be shorter than the lifetime of a fluorophore in a time-domain FLIM system. Even though phasor analysis can effectively minimize the pulse effect by using deconvolution, the precision of a measured lifetime can be degraded seriously. Here, we provide a fundamental theory on pulse-width-dependent measurement precisions in lifetime measurement in the phasor plane. Our theory predicts that high-precision lifetimes can be obtained even with a laser whose pulse width is four times larger than the lifetime of a fluorophore. We have experimentally demonstrated this by measuring the lifetimes of fluorescence probes with 2.57 ns and 3.75 ns lifetimes by using various pulse widths (0.52–38 ns) and modulation frequencies (10–200 MHz). We believe our results open a new possibility of using long pulse-width lasers for high-precision FLIM.
- 20 April 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (9) , 14677-14685
Use of nanosecond excitation pulses in fluorescence lifetime measurement via phasor analysis
We investigated the possibility of using long excitation pulses in fluorescence lifetime imaging microscopy (FLIM) using phasor analysis. It has long been believed that the pulse width of an excitation laser must be shorter than the lifetime of a fluorophore in a time-domain FLIM system. Even though phasor analysis can effectively minimize the pulse effect by using deconvolution, the precision of a measured lifetime can be degraded seriously. Here, we provide a fundamental theory on pulse-width-dependent measurement precisions in lifetime measurement in the phasor plane. Our theory predicts that high-precision lifetimes can be obtained even with a laser whose pulse width is four times larger than the lifetime of a fluorophore. We have experimentally demonstrated this by measuring the lifetimes of fluorescence probes with 2.57 ns and 3.75 ns lifetimes by using various pulse widths (0.52–38 ns) and modulation frequencies (10–200 MHz). We believe our results open a new possibility of using long pulse-width lasers for high-precision FLIM.
- Open Access
Design of an Optical Probe to Monitor Vaginal Hemodynamics during Sexual Arousal
An optical probe was developed to measure the change of oxy-hemoglobin (OHb), deoxy- hemoglobin (RHb), and total hemoglobin (THb) along with temperature from the vaginal wall of female rats. Apomorphine (APO, 80 μg/kg) was administered to elicit sexual arousal in female Sprague Dawley rats (SD, 180–200 g). The behavior changes caused by APO administration were checked before monitoring vaginal responses. The changes of oxy-, deoxy-, and total hemoglobin concentration and the temperature from the vaginal wall were monitored before, during, and after APO administration. Animals were under anesthesia during the measurement. After APO administration, the concentration of OHb (55 ± 29 μM/DPF), RHb (33 ± 25 μM/DPF), and THb (83 ± 59 μM/DPF) in the vaginal wall increased in a few min, while saline administration did not cause any significant change. In case of the vaginal temperature change, APO decreased the temperature slightly in the vaginal wall while saline administration did not show any temperature change in the vaginal wall. As the outcomes demonstrated, the developed probe can detect hemodynamic and temperature variation in the vaginal wall. The hemodynamic information acquired by the probe can be utilized to establish an objective and accurate standard of female sexual disorders.
Open AccessDesign of an Optical Probe to Monitor Vaginal Hemodynamics during Sexual Arousal
An optical probe was developed to measure the change of oxy-hemoglobin (OHb), deoxy- hemoglobin (RHb), and total hemoglobin (THb) along with temperature from the vaginal wall of female rats. Apomorphine (APO, 80 μg/kg) was administered to elicit sexual arousal in female Sprague Dawley rats (SD, 180–200 g). The behavior changes caused by APO administration were checked before monitoring vaginal responses. The changes of oxy-, deoxy-, and total hemoglobin concentration and the temperature from the vaginal wall were monitored before, during, and after APO administration. Animals were under anesthesia during the measurement. After APO administration, the concentration of OHb (55 ± 29 μM/DPF), RHb (33 ± 25 μM/DPF), and THb (83 ± 59 μM/DPF) in the vaginal wall increased in a few min, while saline administration did not cause any significant change. In case of the vaginal temperature change, APO decreased the temperature slightly in the vaginal wall while saline administration did not show any temperature change in the vaginal wall. As the outcomes demonstrated, the developed probe can detect hemodynamic and temperature variation in the vaginal wall. The hemodynamic information acquired by the probe can be utilized to establish an objective and accurate standard of female sexual disorders.
- Open Access
- 7 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 3785
Effect of Air Injection Depth on Big-bubble Formation in Lamellar Keratoplasty: an Ex Vivo Study
This study evaluated the effect of air injection depth in the big-bubble (BB) technique, which is used for corneal tissue preparation in lamellar keratoplasty. The BB technique was performed on ex vivo human corneoscleral buttons using a depth-sensing needle, based on optical coherence tomography (OCT) imaging technology. The needle tip, equipped with a miniaturized OCT depth-sensing probe, was inserted for air injection at a specified depth. Inside the corneal tissue, our needle obtained OCT line profiles, from which residual thickness below the needle tip was measured. Subjects were classified into Groups I, II, III, and IV based on injection depths of 75–80%, 80–85%, 85–90%, and >90% of the full corneal thickness, respectively. Both Type I and II BBs were produced when the mean residual thicknesses of air injection were 109.7 ± 38.0 µm and 52.4 ± 19.2 µm, respectively. Type II BB (4/5) was dominant in group IV. Bubble burst occurred in 1/16 cases of type I BB and 3/16 cases of type II BB, respectively. Injection depth was an important factor in determining the types of BBs produced. Deeper air injection could facilitate formation of Type II BBs, with an increased risk of bubble bursts.
- 7 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 3785
Open AccessEffect of Air Injection Depth on Big-bubble Formation in Lamellar Keratoplasty: an Ex Vivo Study
This study evaluated the effect of air injection depth in the big-bubble (BB) technique, which is used for corneal tissue preparation in lamellar keratoplasty. The BB technique was performed on ex vivo human corneoscleral buttons using a depth-sensing needle, based on optical coherence tomography (OCT) imaging technology. The needle tip, equipped with a miniaturized OCT depth-sensing probe, was inserted for air injection at a specified depth. Inside the corneal tissue, our needle obtained OCT line profiles, from which residual thickness below the needle tip was measured. Subjects were classified into Groups I, II, III, and IV based on injection depths of 75–80%, 80–85%, 85–90%, and >90% of the full corneal thickness, respectively. Both Type I and II BBs were produced when the mean residual thicknesses of air injection were 109.7 ± 38.0 µm and 52.4 ± 19.2 µm, respectively. Type II BB (4/5) was dominant in group IV. Bubble burst occurred in 1/16 cases of type I BB and 3/16 cases of type II BB, respectively. Injection depth was an important factor in determining the types of BBs produced. Deeper air injection could facilitate formation of Type II BBs, with an increased risk of bubble bursts.
- 22 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 74, 52
Enhancement of performance in time-domain FLIM with GaAsP hybrid detectors
GaAsP hybrid detectors, which is new kind of photodetector, has been known as its excellent performance in time correlated single photon counting technique. We have verified that this detector also shows excellent performance in analog mean-delay method, which is another kind of time-domain FLIM, so one can expect enhancement of performance in time-domain FLIM when using the hybrid detector.
- 22 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 74, 52
Enhancement of performance in time-domain FLIM with GaAsP hybrid detectors
GaAsP hybrid detectors, which is new kind of photodetector, has been known as its excellent performance in time correlated single photon counting technique. We have verified that this detector also shows excellent performance in analog mean-delay method, which is another kind of time-domain FLIM, so one can expect enhancement of performance in time-domain FLIM when using the hybrid detector.
- Open Access
- 25 January 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (2) , 1110-1121
VCSEL-based swept source for low-cost optical coherence tomography
We present a novel wavelength-swept laser source for optical coherence tomography (OCT) which is based on the conventional laser diode technology of the vertical-cavity surface-emitting laser (VCSEL). In our self-heating sweep VCSEL (SS-VCSEL), a VCSEL device is simply driven by ramped pulses of currents in direct intensity modulation. The intrinsic property of VCSEL produces a frequency-swept output through the self-heating effect. By the injected current, the temperature of the active region is gradually increased in this effect. Consequently, it changes the wavelength of the laser output by itself. In this study, various characteristics of our SS-VCSEL were experimentally investigated for low-cost instrumentation of a swept source OCT system. A low-cost SS-VCSEL-based OCT system was demonstrated in this research that provided an axial resolution of 135 μm in air, sensitivity of −91 dB and a maximum imaging range longer than 10 cm when our source was operated at a sweep repetition rate of 5 kHz with an output power of 0.41 mW. Based on the experimental observations, we believe that our SS-VCSEL swept source can be an economic alternative in some of low-cost or long-range applications of OCT.
- 25 January 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (2) , 1110-1121
Open AccessVCSEL-based swept source for low-cost optical coherence tomography
We present a novel wavelength-swept laser source for optical coherence tomography (OCT) which is based on the conventional laser diode technology of the vertical-cavity surface-emitting laser (VCSEL). In our self-heating sweep VCSEL (SS-VCSEL), a VCSEL device is simply driven by ramped pulses of currents in direct intensity modulation. The intrinsic property of VCSEL produces a frequency-swept output through the self-heating effect. By the injected current, the temperature of the active region is gradually increased in this effect. Consequently, it changes the wavelength of the laser output by itself. In this study, various characteristics of our SS-VCSEL were experimentally investigated for low-cost instrumentation of a swept source OCT system. A low-cost SS-VCSEL-based OCT system was demonstrated in this research that provided an axial resolution of 135 μm in air, sensitivity of −91 dB and a maximum imaging range longer than 10 cm when our source was operated at a sweep repetition rate of 5 kHz with an output power of 0.41 mW. Based on the experimental observations, we believe that our SS-VCSEL swept source can be an economic alternative in some of low-cost or long-range applications of OCT.
- Open Access
- 21 April 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (5) , 1782-1796
Ultra-thin and flexible endoscopy probe for optical coherence tomography based on stepwise transitional core fiber
We present an ultra-thin fiber-body endoscopy probe for optical coherence tomography (OCT) which is based on a stepwise transitional core (STC) fiber. In a minimalistic design, our probe was made of spliced specialty fibers that could be directly used for beam probing optics without using a lens. In our probe, the OCT light delivered through a single-mode fiber was efficiently expanded to a large mode field of 24 μm diameter for a low beam divergence. The size of our probe was 85 μm in the probe’s diameter while operated in a 160-μm thick protective tubing. Through theoretical and experimental analyses, our probe was found to exhibit various attractive features in terms of compactness, flexibility and reliability along with its excellent fabrication simplicity.
- 21 April 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (5) , 1782-1796
Open AccessUltra-thin and flexible endoscopy probe for optical coherence tomography based on stepwise transitional core fiber
We present an ultra-thin fiber-body endoscopy probe for optical coherence tomography (OCT) which is based on a stepwise transitional core (STC) fiber. In a minimalistic design, our probe was made of spliced specialty fibers that could be directly used for beam probing optics without using a lens. In our probe, the OCT light delivered through a single-mode fiber was efficiently expanded to a large mode field of 24 μm diameter for a low beam divergence. The size of our probe was 85 μm in the probe’s diameter while operated in a 160-μm thick protective tubing. Through theoretical and experimental analyses, our probe was found to exhibit various attractive features in terms of compactness, flexibility and reliability along with its excellent fabrication simplicity.