Patrice Martinez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Patrice Martinez has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
A. Spang
Université Côte d'Azur Observatoire de la Côte d'Azur CNRS Laboratoire Lagrange France
3 shared publicationsK. Dohlen
Aix Marseille Univ CNRS CNES LAM Marseille France
3 shared publicationsA. Costille
UJF – Grenoble 1/CNRS – INSU, Institut de Planétologie et d’Astrophysique de Grenoble UMR 5274, 38041 Grenoble, France
2 shared publicationsA. Marcotto
Observatoire de la Côte d'Azur Université Côte d'Azur CNRS Laboratoire Lagrange Nice France
2 shared publicationsC. Gouvret
Observatoire de la Côte d'Azur Université Côte d'Azur CNRS Laboratoire Lagrange Nice France
2 shared publicationsJ. F. Sauvage
Laboratoire d’Astrophysique de Marseille, UMR 7326, CNRS, Université de Provence, 38 rue Frédéric Joliot-Curie, 13388 Marseille Cedex 13, France
2 shared publications
Latest Publications
- Open Access
- 14 July 2025
- Published by EDP Sciences in Astronomy & Astrophysics
Revisiting the differential optical transfer function wavefront sensing technique for high-contrast imaging
Wavefront sensors (WFSs) are widely used in optical measurements. Initially developed more than 40 years ago for adaptive optics (AO) systems in astronomy, they have become essential components in various stages of high dynamic range imaging systems. The differential optical transfer function (dOTF) is a wavefront sensing technique that estimates the complex field of the pupil using differential intensities in the image plane. dOTF has a wide range of applications in astronomy, from optical shop testing to cophasing of segmented optics. This study aims to expand the application of dOTF from classical to high-contrast imaging. Building on prior analyses in the literature, where the dOTF phase estimator was derived under the small-phase approximation and applied in classical imaging mode, we reformulated the phase estimator and extended it to include amplitude aberrations. This reformulation enabled the reconstruction of the complete electric field, allowing us to assess its applicability to dark hole digging, and to measure and correct non-common path aberrations (NCPAs) and cophasing misalignments, in coronagraphic imaging mode. Our findings are validated through comprehensive simulations, statistical analysis, and supported by preliminary experimental data. With a single-actuator probe, the dOTF demonstrates effective joint phase and amplitude wavefront sensing in coronagraphic imaging mode, without prior knowledge of the coronagraph type, a capability not previously documented. Beyond its capability to correct for NCPAs and cophasing misalignment, dOTF provides a simplified alternative to pair-wise probing (PWP) wavefront sensing. The dOTF enables straightforward complex field measurement, with the deformable mirror (DM) actively participating in the process. By reducing imaging workload, it offers a promising alternative to other coronagraphic wavefront sensors. Its potential for high-contrast imaging has implications for current telescopes, upcoming missions like the Nancy Grace Roman Space Telescope, future large observatories, and laboratory conditions during instrument AIT phases.
- 14 July 2025
- Published by EDP Sciences in Astronomy & Astrophysics
Open AccessRevisiting the differential optical transfer function wavefront sensing technique for high-contrast imaging
Wavefront sensors (WFSs) are widely used in optical measurements. Initially developed more than 40 years ago for adaptive optics (AO) systems in astronomy, they have become essential components in various stages of high dynamic range imaging systems. The differential optical transfer function (dOTF) is a wavefront sensing technique that estimates the complex field of the pupil using differential intensities in the image plane. dOTF has a wide range of applications in astronomy, from optical shop testing to cophasing of segmented optics. This study aims to expand the application of dOTF from classical to high-contrast imaging. Building on prior analyses in the literature, where the dOTF phase estimator was derived under the small-phase approximation and applied in classical imaging mode, we reformulated the phase estimator and extended it to include amplitude aberrations. This reformulation enabled the reconstruction of the complete electric field, allowing us to assess its applicability to dark hole digging, and to measure and correct non-common path aberrations (NCPAs) and cophasing misalignments, in coronagraphic imaging mode. Our findings are validated through comprehensive simulations, statistical analysis, and supported by preliminary experimental data. With a single-actuator probe, the dOTF demonstrates effective joint phase and amplitude wavefront sensing in coronagraphic imaging mode, without prior knowledge of the coronagraph type, a capability not previously documented. Beyond its capability to correct for NCPAs and cophasing misalignment, dOTF provides a simplified alternative to pair-wise probing (PWP) wavefront sensing. The dOTF enables straightforward complex field measurement, with the deformable mirror (DM) actively participating in the process. By reducing imaging workload, it offers a promising alternative to other coronagraphic wavefront sensors. Its potential for high-contrast imaging has implications for current telescopes, upcoming missions like the Nancy Grace Roman Space Telescope, future large observatories, and laboratory conditions during instrument AIT phases.
- Open Access
- 5 July 2024
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 532 (2) , 2892-2904
High contrast at small separation – III. Impact on the dark hole of MEMS deformable mirror control electronics
The creation of a dark hole (DH) region in the science image for exoplanet direct detection depends on deformable mirrors (DMs), where the imperfect control of DM limits the achievable contrast. The mirror surface height resolution is set by the DM drive electronics, and the quantization errors in DM impact the contrast in the DH. Consequently, determining the optimal voltage value for the flattening map of DM is essential, as it involves balancing dynamic and accuracy considerations. We conduct a numerical study to examine the impact of these parameters on microelectromechanical DM within the high-contrast field of view of several DHs with various characteristics and optical configurations. Our analysis includes an exploration of their influence on both small and moderate angular separations. We compare our numerical results with a formula available in the literature that aims to capture the dependence of contrast on DM quantization errors. We show that the formula accuracy to predict the contrast limit when the DM deflection curves follow the as-manufactured quadratic power law is dependent on the DM flattening map voltage domain, regardless of DH size and angular separations. Further these results appear to be insensitive to factors such as actuator number, coronagraph type, set-up architecture, and science objective (small or moderate angular separations). We provide guidelines for determining the optimal voltage for the DM flattening map, discuss the domain validity of the formula used to predict DM quantization errors on the contrast, and provide insights into balancing DM actuator density and mirror surface height resolution.
- 5 July 2024
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 532 (2) , 2892-2904
Open AccessHigh contrast at small separation – III. Impact on the dark hole of MEMS deformable mirror control electronics
The creation of a dark hole (DH) region in the science image for exoplanet direct detection depends on deformable mirrors (DMs), where the imperfect control of DM limits the achievable contrast. The mirror surface height resolution is set by the DM drive electronics, and the quantization errors in DM impact the contrast in the DH. Consequently, determining the optimal voltage value for the flattening map of DM is essential, as it involves balancing dynamic and accuracy considerations. We conduct a numerical study to examine the impact of these parameters on microelectromechanical DM within the high-contrast field of view of several DHs with various characteristics and optical configurations. Our analysis includes an exploration of their influence on both small and moderate angular separations. We compare our numerical results with a formula available in the literature that aims to capture the dependence of contrast on DM quantization errors. We show that the formula accuracy to predict the contrast limit when the DM deflection curves follow the as-manufactured quadratic power law is dependent on the DM flattening map voltage domain, regardless of DH size and angular separations. Further these results appear to be insensitive to factors such as actuator number, coronagraph type, set-up architecture, and science objective (small or moderate angular separations). We provide guidelines for determining the optimal voltage for the DM flattening map, discuss the domain validity of the formula used to predict DM quantization errors on the contrast, and provide insights into balancing DM actuator density and mirror surface height resolution.
- Open Access
- 8 April 2024
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 684, L5
Differential optical transfer function (dOTF) broad-spectrum wavefront sensing using integral field unit spectroscopy
Context.Detecting and characterizing Earth-like exoplanets is a critical scientific goal for the next generation of telescopes. However, current direct imaging instruments are hindered by evolving noncommon path aberrations (NCPAs), which lead to persistent speckles in the images. The differential optical transfer function (dOTF) is an image-based, noniterative, and model-independent wavefront sensor that combines differential images to estimate the complex field of the pupil.Aims.Given the objective of spectrally characterizing exoplanets to discern their composition and potentially detect biosignatures, we aim to explore the integration of the dOTF sensing method with an integral field unit (IFU) spectrograph. An IFU spectrograph generates a spectral data cube that contains diverse spectral information within a single dataset. Combining these two concepts is expected to improve the efficiency with which NCPAs can be spectrally measured and characterized.Methods.This Letter presents an implementation strategy for integrating dOTF and IFU spectroscopy data, enabling estimations of the electric field at various wavelengths simultaneously.Results.This method is specifically optimized to provide the most effective combination with minimal hardware requirements. It involves the use of multiple simultaneous deformable mirror actuator displacements in conjunction with an adapted Lyot stop employing a circular variable filter.Conclusions.The dOTF wavefront sensor coupled with an IFU spectrograph promises to be rapid and efficient, capable of measuring NCPAs across the entire spectrum provided by the spectrograph. Because the combination of dOTF and IFU spectroscopy is immediately applicable, it is of potential interest for various present-day on-sky instruments, as well as future IFU-based instruments coupled to the next generation of extremely large telescopes (ELTs).
- 8 April 2024
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 684, L5
Open AccessDifferential optical transfer function (dOTF) broad-spectrum wavefront sensing using integral field unit spectroscopy
Context.Detecting and characterizing Earth-like exoplanets is a critical scientific goal for the next generation of telescopes. However, current direct imaging instruments are hindered by evolving noncommon path aberrations (NCPAs), which lead to persistent speckles in the images. The differential optical transfer function (dOTF) is an image-based, noniterative, and model-independent wavefront sensor that combines differential images to estimate the complex field of the pupil.Aims.Given the objective of spectrally characterizing exoplanets to discern their composition and potentially detect biosignatures, we aim to explore the integration of the dOTF sensing method with an integral field unit (IFU) spectrograph. An IFU spectrograph generates a spectral data cube that contains diverse spectral information within a single dataset. Combining these two concepts is expected to improve the efficiency with which NCPAs can be spectrally measured and characterized.Methods.This Letter presents an implementation strategy for integrating dOTF and IFU spectroscopy data, enabling estimations of the electric field at various wavelengths simultaneously.Results.This method is specifically optimized to provide the most effective combination with minimal hardware requirements. It involves the use of multiple simultaneous deformable mirror actuator displacements in conjunction with an adapted Lyot stop employing a circular variable filter.Conclusions.The dOTF wavefront sensor coupled with an IFU spectrograph promises to be rapid and efficient, capable of measuring NCPAs across the entire spectrum provided by the spectrograph. Because the combination of dOTF and IFU spectroscopy is immediately applicable, it is of potential interest for various present-day on-sky instruments, as well as future IFU-based instruments coupled to the next generation of extremely large telescopes (ELTs).
- Open Access
- 15 December 2023
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 680, L12
Bisymmetric pupil modification deconvolution strategy for differential optical transfer function (dOTF) wavefront sensing
Context.The differential optical transfer function (dOTF) is a model-independent image-based wavefront sensor for measuring the complex pupil field (phase and amplitude). This method is particularly suitable for compensating non-common path aberrations or for the phasing of segmented telescopes that often prevent the so-called diffraction-limit resolution from being achieved with real-world instruments.Aims.The main problem inherent to the dOTF approach is to address the effect of the convolution. The resolution of the recovered complex pupil field is impacted by the size of the pupil modification. The complex pupil field estimated by the dOTF is blurred by convolution with the complex conjugate of the pupil modification. If the pupil modification involves a non-negligible region of the pupil (actuator or segment poke), it causes significant blurring and resolution loss.Methods.We propose a bisymmetric pupil modification deconvolution strategy to solve this problem. We use two different dOTFs with the opposite-sign pupil modification to identify the pupil modification location and four dOTFs with a symmetric pupil modification to complete the knowledge of their impact on the complex pupil field prior to the deconvolution process in the Fourier domain. The proposed strategy solves the intrinsic limitation of a former deconvolution algorithm, namely the cross-iteration deconvolution algorithm, which is restricted to amplitude pupil modification and precludes its applicability to phase pupil modification.Results.The bissymetric pupil modification deconvolution strategy is a novel probing pattern that permits the extension of iterative cross-deconvolution to phase-only probes. The effectiveness of the proposed approach has been validated analytically and with numerical simulations.Conclusions.The bisymmetric pupil modification deconvolution strategy can improve the resolution and accuracy of dOTF wavefront sensing and contributes to efficient and precise image-based wavefront sensing techniques.
- 15 December 2023
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 680, L12
Open AccessBisymmetric pupil modification deconvolution strategy for differential optical transfer function (dOTF) wavefront sensing
Context.The differential optical transfer function (dOTF) is a model-independent image-based wavefront sensor for measuring the complex pupil field (phase and amplitude). This method is particularly suitable for compensating non-common path aberrations or for the phasing of segmented telescopes that often prevent the so-called diffraction-limit resolution from being achieved with real-world instruments.Aims.The main problem inherent to the dOTF approach is to address the effect of the convolution. The resolution of the recovered complex pupil field is impacted by the size of the pupil modification. The complex pupil field estimated by the dOTF is blurred by convolution with the complex conjugate of the pupil modification. If the pupil modification involves a non-negligible region of the pupil (actuator or segment poke), it causes significant blurring and resolution loss.Methods.We propose a bisymmetric pupil modification deconvolution strategy to solve this problem. We use two different dOTFs with the opposite-sign pupil modification to identify the pupil modification location and four dOTFs with a symmetric pupil modification to complete the knowledge of their impact on the complex pupil field prior to the deconvolution process in the Fourier domain. The proposed strategy solves the intrinsic limitation of a former deconvolution algorithm, namely the cross-iteration deconvolution algorithm, which is restricted to amplitude pupil modification and precludes its applicability to phase pupil modification.Results.The bissymetric pupil modification deconvolution strategy is a novel probing pattern that permits the extension of iterative cross-deconvolution to phase-only probes. The effectiveness of the proposed approach has been validated analytically and with numerical simulations.Conclusions.The bisymmetric pupil modification deconvolution strategy can improve the resolution and accuracy of dOTF wavefront sensing and contributes to efficient and precise image-based wavefront sensing techniques.
- Open Access
- 4 December 2023
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 680, A6
Design, manufacturing, and testing of phase-induced amplitude apodization and phase-shifting optics for segmented telescopes
Context. The phase-induced amplitude apodization complex mask coronagraph (PIAACMC) is a coronagraph architecture for the direct detection of extrasolar planets. The PIAACMC can achieve close to the theoretical performance limit at small angular sepa-rations. The concept is a high-performance PIAA-based coronagraph that is sufficiently versatile to be designed for next-generation segmented and obscured telescope apertures. Aims. We present key elements of the design and manufacture of a PIAACMC for the segmented pupil experiment for exoplanet detection (SPEED) testbed. The primary components of a PIAACMC system are the PIAA optics and the complex phase-shifting focal plane mask (FPM). The most challenging part of the system to model is the error on the manufacturing of the two PIAA mirrors. Methods. In this paper, we describe the design and manufacturing of the FPM and moderate-sag PIAA optics using photolithography and etching. We present the design and fabrication of the PIAACMC, along with metrology, and an initial assessment of the PIAACMC optics efficiency. Results. Errors in the fabricated component profiles degrade the overall performance. We show that the depth errors involved are of a few tens of nanometers and a few hundred nanometers for the FPM and PIAA optics, respectively. The metrological and individual per¬formance analysis of the FPM and PIAA optics provides us with an in-depth understanding of these optical quality of the components, manufacturing error propagation, and the effects of these on performance. Because the deformable mirror (DM) location is critical in a PIAA system, we show that despite the pupil remapping effect of the PIAA optics, a dual-DM wavefront control and shaping system architecture optimized for short angular separations is operating adequately to compensate for manufacturing errors and for the dark zone generated in the focal plane. Conclusions. Because the errors involved are comparable to the wavefront error on the optics, wavefront control can compensate for them. Our measurements provide reliable models that, when used in simulations, allow us to refine component specification given the manufacturing errors at the raw coronagraphic performance level as well as after wavefront control and shaping.
- 4 December 2023
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 680, A6
Open AccessDesign, manufacturing, and testing of phase-induced amplitude apodization and phase-shifting optics for segmented telescopes
Context. The phase-induced amplitude apodization complex mask coronagraph (PIAACMC) is a coronagraph architecture for the direct detection of extrasolar planets. The PIAACMC can achieve close to the theoretical performance limit at small angular sepa-rations. The concept is a high-performance PIAA-based coronagraph that is sufficiently versatile to be designed for next-generation segmented and obscured telescope apertures. Aims. We present key elements of the design and manufacture of a PIAACMC for the segmented pupil experiment for exoplanet detection (SPEED) testbed. The primary components of a PIAACMC system are the PIAA optics and the complex phase-shifting focal plane mask (FPM). The most challenging part of the system to model is the error on the manufacturing of the two PIAA mirrors. Methods. In this paper, we describe the design and manufacturing of the FPM and moderate-sag PIAA optics using photolithography and etching. We present the design and fabrication of the PIAACMC, along with metrology, and an initial assessment of the PIAACMC optics efficiency. Results. Errors in the fabricated component profiles degrade the overall performance. We show that the depth errors involved are of a few tens of nanometers and a few hundred nanometers for the FPM and PIAA optics, respectively. The metrological and individual per¬formance analysis of the FPM and PIAA optics provides us with an in-depth understanding of these optical quality of the components, manufacturing error propagation, and the effects of these on performance. Because the deformable mirror (DM) location is critical in a PIAA system, we show that despite the pupil remapping effect of the PIAA optics, a dual-DM wavefront control and shaping system architecture optimized for short angular separations is operating adequately to compensate for manufacturing errors and for the dark zone generated in the focal plane. Conclusions. Because the errors involved are comparable to the wavefront error on the optics, wavefront control can compensate for them. Our measurements provide reliable models that, when used in simulations, allow us to refine component specification given the manufacturing errors at the raw coronagraphic performance level as well as after wavefront control and shaping.
- Open Access
- 19 March 2020
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 635, A126
Design and manufacturing of a multi-zone phase-shifting coronagraph mask for extremely large telescopes
Context. High-contrast imaging of exoplanets around nearby stars with future large-segmented apertures requires starlight suppression systems optimized for complex aperture geometries. Future extremely large telescopes (ELTs) equipped with high-contrast instruments operating as close as possible to the diffraction limit will open a bulk of targets in the habitable zone around M-stars. In this context, the phase-induced amplitude apodization complex mask coronagraph (PIAACMC) is a promising concept for high-efficiency coronagraphic imaging at small angular separations with segmented telescopes. Aims. The complex focal plane mask of the PIAACMC is a multi-zone, phase-shifting mask comprised of tiled hexagons that vary in depth. The mask requires micro-fabrication techniques because it is generally made of hundreds micron-scale hexagonal zones with depths ranging over a few microns. We aim to demonstrate that the complex focal plane mask of a PIAACMC with a small inner working angle can be designed and manufactured for segmented apertures. Methods. We report on the numerical design, specifications, manufacturing, and characterization of a PIAACMC complex focal plane mask for the segmented pupil experiment for exoplanet detection facility. Results. Our PIAACMC design offers an inner working angle of 1.3 λ/D and is optimized for a 30% telescope-central-obscuration ratio including six secondary support structures (ESO/ELT design). The fabricated reflective focal plane mask is made of 499 hexagons, and the characteristic size of the mask features is 25 μm, with depths ranging over ±0.4 μm. The mask sag local deviation is measured to an average error of 3 nm and standard deviation of 6 nm rms. The metrological analysis of the mask using interferential microscopy gives access to an in-depth understanding of the component’s optical quality, including a complete mapping of the zone depth distribution zone-depth distribution. The amplitude of the errors in the fabricated mask are within the wavefront control dynamic range. Conclusions. We demonstrate the feasibility of fabricating and characterizing high-quality PIAA complex focal plane masks.
- 19 March 2020
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 635, A126
Open AccessDesign and manufacturing of a multi-zone phase-shifting coronagraph mask for extremely large telescopes
Context. High-contrast imaging of exoplanets around nearby stars with future large-segmented apertures requires starlight suppression systems optimized for complex aperture geometries. Future extremely large telescopes (ELTs) equipped with high-contrast instruments operating as close as possible to the diffraction limit will open a bulk of targets in the habitable zone around M-stars. In this context, the phase-induced amplitude apodization complex mask coronagraph (PIAACMC) is a promising concept for high-efficiency coronagraphic imaging at small angular separations with segmented telescopes. Aims. The complex focal plane mask of the PIAACMC is a multi-zone, phase-shifting mask comprised of tiled hexagons that vary in depth. The mask requires micro-fabrication techniques because it is generally made of hundreds micron-scale hexagonal zones with depths ranging over a few microns. We aim to demonstrate that the complex focal plane mask of a PIAACMC with a small inner working angle can be designed and manufactured for segmented apertures. Methods. We report on the numerical design, specifications, manufacturing, and characterization of a PIAACMC complex focal plane mask for the segmented pupil experiment for exoplanet detection facility. Results. Our PIAACMC design offers an inner working angle of 1.3 λ/D and is optimized for a 30% telescope-central-obscuration ratio including six secondary support structures (ESO/ELT design). The fabricated reflective focal plane mask is made of 499 hexagons, and the characteristic size of the mask features is 25 μm, with depths ranging over ±0.4 μm. The mask sag local deviation is measured to an average error of 3 nm and standard deviation of 6 nm rms. The metrological analysis of the mask using interferential microscopy gives access to an in-depth understanding of the component’s optical quality, including a complete mapping of the zone depth distribution zone-depth distribution. The amplitude of the errors in the fabricated mask are within the wavefront control dynamic range. Conclusions. We demonstrate the feasibility of fabricating and characterizing high-quality PIAA complex focal plane masks.
- Open Access
- 17 September 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 629, L10
Fast-modulation imaging with the self-coherent camera
Context. Direct detection of exoplanets requires imaging in a highly dynamic range and exquisite image quality and stability. Wavefront error (atmospheric errors, manufacturing errors on optics, cophasing residuals, temperature variations, etc.) will limit the efficiency of this endeavor by creating various flavors of speckles that evolve with different timescales. Active wavefront-error correction using a deformable mirror requires measuring the wavefront aberrations in the science image with high accuracy and in a shorter time than the duration of the dominant speckle lifetime. Aims. The self-coherent camera (SCC) is a focal plane wavefront sensor exploiting the coherence of light to generate Fizeau fringes in the image plane to spatially encode speckles. The SCC combines a coronagraph and a modified Lyot stop to which a reference channel is added. The conventional SCC is restricted to long-exposure measurements because the light transmitted through the reference channel is limited. The SCC can correct quasi-static aberrations but precludes short-lived atmospheric aberrations from the measurement. Methods. I propose an alternative to the conventional SCC that I call the fast-modulated SCC. It uses a simplified Lyot stop design and an adequate Fourier filtering algorithm. The theory is established and confirmed by means of numerical simulations. Results. The SCC theory dictates that the separation between the classical Lyot stop and the reference channel must be larger than 1.5 times the Lyot stop diameter. The fast-modulated SCC allows for the reference channel to be placed anywhere, in particular in the vicinity of the pupil where the maximum of diffracted light is found. This alternative represents a complete game changer for the sensor: full compatibility with any type of coronagraph, easy installation in existing instruments, and versatility by accessing short- and long-time exposure measurements. Conclusions. While the conventional SCC can almost not be implemented in existing instruments because the optical beam footprint in the instrument must be wide enough to illuminate the reference channel, which is often seen as a significant shortcoming, the fast-modulated SCC does not require any constraint on this. The fast-modulated SCC also relaxes the high sampling requirement to resolve the fringes, which is usually incompatible with the observation of fainter targets because the fringes are larger. The fast-modulated SCC simultaneously counteracts the two original shortcomings of the SCC concept.
- 17 September 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 629, L10
Open AccessFast-modulation imaging with the self-coherent camera
Context. Direct detection of exoplanets requires imaging in a highly dynamic range and exquisite image quality and stability. Wavefront error (atmospheric errors, manufacturing errors on optics, cophasing residuals, temperature variations, etc.) will limit the efficiency of this endeavor by creating various flavors of speckles that evolve with different timescales. Active wavefront-error correction using a deformable mirror requires measuring the wavefront aberrations in the science image with high accuracy and in a shorter time than the duration of the dominant speckle lifetime. Aims. The self-coherent camera (SCC) is a focal plane wavefront sensor exploiting the coherence of light to generate Fizeau fringes in the image plane to spatially encode speckles. The SCC combines a coronagraph and a modified Lyot stop to which a reference channel is added. The conventional SCC is restricted to long-exposure measurements because the light transmitted through the reference channel is limited. The SCC can correct quasi-static aberrations but precludes short-lived atmospheric aberrations from the measurement. Methods. I propose an alternative to the conventional SCC that I call the fast-modulated SCC. It uses a simplified Lyot stop design and an adequate Fourier filtering algorithm. The theory is established and confirmed by means of numerical simulations. Results. The SCC theory dictates that the separation between the classical Lyot stop and the reference channel must be larger than 1.5 times the Lyot stop diameter. The fast-modulated SCC allows for the reference channel to be placed anywhere, in particular in the vicinity of the pupil where the maximum of diffracted light is found. This alternative represents a complete game changer for the sensor: full compatibility with any type of coronagraph, easy installation in existing instruments, and versatility by accessing short- and long-time exposure measurements. Conclusions. While the conventional SCC can almost not be implemented in existing instruments because the optical beam footprint in the instrument must be wide enough to illuminate the reference channel, which is often seen as a significant shortcoming, the fast-modulated SCC does not require any constraint on this. The fast-modulated SCC also relaxes the high sampling requirement to resolve the fringes, which is usually incompatible with the observation of fainter targets because the fringes are larger. The fast-modulated SCC simultaneously counteracts the two original shortcomings of the SCC concept.
- Open Access
Laser-guide-stars used for cophasing broad capture ranges
Segmented primary mirrors are indispensable to master the steady increase in spatial resolution. Phasing optics systems must reduce segment misalignments to guarantee the high optical quality required for astronomical science programs. Modern telescopes routinely use adaptive optics systems to compensate for the atmosphere and use laser-guide-stars to create artificial stars as bright references in the field of observation. Because multiple laser-guide-star adaptive optics are being implemented in all major observatories, we propose to use man-made stars not only for adaptive optics, but for phasing optics. We propose a method called the doublet-wavelength coherence technique (DWCT), exploiting the D lines of sodium in the mesosphere using laser guide-stars. The signal coherence properties are then used. The DWCT capture range exceeds current abilities by a factor of 100. It represents a change in paradigm by improving the phasing optics capture range from micrometric to millimetric. It thereby potentially eliminates the need of a man-made mechanical pre-phasing step. Extremely large telescopes require hundreds of segments, several of which need to be substituted on a daily basis to be recoated. The DWCT relaxes mechanical integration requirements and speeds up integration and re-integration process.
Open AccessLaser-guide-stars used for cophasing broad capture ranges
Segmented primary mirrors are indispensable to master the steady increase in spatial resolution. Phasing optics systems must reduce segment misalignments to guarantee the high optical quality required for astronomical science programs. Modern telescopes routinely use adaptive optics systems to compensate for the atmosphere and use laser-guide-stars to create artificial stars as bright references in the field of observation. Because multiple laser-guide-star adaptive optics are being implemented in all major observatories, we propose to use man-made stars not only for adaptive optics, but for phasing optics. We propose a method called the doublet-wavelength coherence technique (DWCT), exploiting the D lines of sodium in the mesosphere using laser guide-stars. The signal coherence properties are then used. The DWCT capture range exceeds current abilities by a factor of 100. It represents a change in paradigm by improving the phasing optics capture range from micrometric to millimetric. It thereby potentially eliminates the need of a man-made mechanical pre-phasing step. Extremely large telescopes require hundreds of segments, several of which need to be substituted on a daily basis to be recoated. The DWCT relaxes mechanical integration requirements and speeds up integration and re-integration process.
- Open Access
Multiwavelength active optics Shack-Hartmann sensor for seeing and turbulence outer scale monitoring
Real-time seeing and outer scale estimation at the location of the focus of a telescope is fundamental for the adaptive optics systems dimensioning and performance prediction, as well as for the operational aspects of instruments. This study attempts to take advantage of multiwavelength long exposure images to instantaneously and simultaneously derive the turbulence outer scale and seeing from the full-width at half-maximum (FWHM) of seeing-limited images taken at the focus of a telescope. These atmospheric parameters are commonly measured in most observatories by different methods located away from the telescope platform, and thus differing from the effective estimates at the focus of a telescope, mainly because of differences in pointing orientation, height above the ground, or local seeing bias (dome contribution). Long exposure images can either directly be provided by any multiwavelength scientific imager or spectrograph, or alternatively from a modified active optics Shack-Hartmann sensor (AOSH). From measuring simultaneously the AOSH sensor spot point spread function FWHMs at different wavelengths, one can estimate the instantaneous outer scale in addition to seeing. Although AOSH sensors are specified to measure not spot sizes but slopes, real-time r0 and L0 measurements from spot FWHMs can be obtained at the critical location where they are needed with major advantages over scientific instrument images: insensitivity to the telescope field stabilization, and being continuously available. Assuming an alternative optical design allowing simultaneous multiwavelength images, AOSH sensor gathers all the advantages for real-time seeing and outer scale monitoring. With the substantial interest in the design of extremely large telescopes, such a system could have a considerable importance.
Open AccessMultiwavelength active optics Shack-Hartmann sensor for seeing and turbulence outer scale monitoring
Real-time seeing and outer scale estimation at the location of the focus of a telescope is fundamental for the adaptive optics systems dimensioning and performance prediction, as well as for the operational aspects of instruments. This study attempts to take advantage of multiwavelength long exposure images to instantaneously and simultaneously derive the turbulence outer scale and seeing from the full-width at half-maximum (FWHM) of seeing-limited images taken at the focus of a telescope. These atmospheric parameters are commonly measured in most observatories by different methods located away from the telescope platform, and thus differing from the effective estimates at the focus of a telescope, mainly because of differences in pointing orientation, height above the ground, or local seeing bias (dome contribution). Long exposure images can either directly be provided by any multiwavelength scientific imager or spectrograph, or alternatively from a modified active optics Shack-Hartmann sensor (AOSH). From measuring simultaneously the AOSH sensor spot point spread function FWHMs at different wavelengths, one can estimate the instantaneous outer scale in addition to seeing. Although AOSH sensors are specified to measure not spot sizes but slopes, real-time r0 and L0 measurements from spot FWHMs can be obtained at the critical location where they are needed with major advantages over scientific instrument images: insensitivity to the telescope field stabilization, and being continuously available. Assuming an alternative optical design allowing simultaneous multiwavelength images, AOSH sensor gathers all the advantages for real-time seeing and outer scale monitoring. With the substantial interest in the design of extremely large telescopes, such a system could have a considerable importance.
- Open Access
SPEED: the Segmented Pupil Experiment for Exoplanet Detection
Searching for nearby exoplanets with direct imaging is one of the major scientific drivers for both space and ground-based programs. While the second generation of dedicated high-contrast instruments on 8-m class telescopes is about to greatly expand the sample of directly imaged planets, exploring the planetary parameter space to hitherto-unseen regions ideally down to Terrestrial planets is a major technological challenge for the forthcoming decades. This requires increasing spatial resolution and significantly improving high contrast imaging capabilities at close angular separations. Segmented telescopes offer a practical path toward dramatically enlarging telescope diameter from the ground (ELTs), or achieving optimal diameter in space. However, translating current technological advances in the domain of high-contrast imaging for monolithic apertures to the case of segmented apertures is far from trivial. SPEED (the segmented pupil experiment for exoplanet detection) is a new instrumental facility in development at the Lagrange laboratory for enabling strategies and technologies for high-contrast instrumentation with segmented telescopes. SPEED combines wavefront control including precision segment phasing architectures, wavefront shaping using two sequential high order deformable mirrors for both phase and amplitude control, and advanced coronagraphy struggled to very close angular separations (PIAACMC). SPEED represents significant investments and technology developments towards the ELT area and future spatial missions, and will offer an ideal cocoon to pave the road of technological progress in both phasing and high-contrast domains with complex/irregular apertures. In this paper, we describe the overall design and philosophy of the SPEED bench.
Open AccessSPEED: the Segmented Pupil Experiment for Exoplanet Detection
Searching for nearby exoplanets with direct imaging is one of the major scientific drivers for both space and ground-based programs. While the second generation of dedicated high-contrast instruments on 8-m class telescopes is about to greatly expand the sample of directly imaged planets, exploring the planetary parameter space to hitherto-unseen regions ideally down to Terrestrial planets is a major technological challenge for the forthcoming decades. This requires increasing spatial resolution and significantly improving high contrast imaging capabilities at close angular separations. Segmented telescopes offer a practical path toward dramatically enlarging telescope diameter from the ground (ELTs), or achieving optimal diameter in space. However, translating current technological advances in the domain of high-contrast imaging for monolithic apertures to the case of segmented apertures is far from trivial. SPEED (the segmented pupil experiment for exoplanet detection) is a new instrumental facility in development at the Lagrange laboratory for enabling strategies and technologies for high-contrast instrumentation with segmented telescopes. SPEED combines wavefront control including precision segment phasing architectures, wavefront shaping using two sequential high order deformable mirrors for both phase and amplitude control, and advanced coronagraphy struggled to very close angular separations (PIAACMC). SPEED represents significant investments and technology developments towards the ELT area and future spatial missions, and will offer an ideal cocoon to pave the road of technological progress in both phasing and high-contrast domains with complex/irregular apertures. In this paper, we describe the overall design and philosophy of the SPEED bench.