Manoj Kumar Semwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Manoj Kumar Semwal has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Aruna Kaushik
6 shared publicationsSakshi Singhal
4 shared publicationsArti Sarin
Department of Neurosurgery, Gammaknife Surgery Centre, Army Hospital (R&R), Delhi Cantonment, New Delhi, India
2 shared publicationsAshok Kumar
Department of Radiation Oncology, Army Hospital Research and Referral, Delhi, India
2 shared publicationsHarishchandra Gupta
2 shared publicationsJulipriya Jena
2 shared publications
Latest Publications
- 10 October 2026
- Published by Elsevier in Radiation Measurements
- Vol. 200
3D dosimetry of Ru-106 notched eye plaques of BARC-make using Monte Carlo simulation technique
- 10 October 2026
- Published by Elsevier in Radiation Measurements
- Vol. 200
3D dosimetry of Ru-106 notched eye plaques of BARC-make using Monte Carlo simulation technique
- Open Access
- 28 May 2026
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 25
A comparative study of vaginal doses in intracavitary and template-based interstitial brachytherapy in cancer of cervix patients
Aim: To estimate and compare the vaginal doses in terms of posterior inferior border of symphysis (PIBS) points such as PIBS, PIBS+2, PIBS-2, and vaginal reference length (VRL) for patients of cancer of cervix (CC) treated with intracavitary brachytherapy (ICBT) using Fletcher Williamson applicator (FW) and interstitial brachytherapy (ISBT) using Martinez Universal Perineal Interstitial Template (MUPIT). Material/methods: Treatment plans of a total of 36 consecutive CC patients, who underwent ICBT and ISBT with FW and MUPIT respectively, were retrospectively included in the study. The 3D treatment planning for all the patients had been performed on computed tomography (CT) images. The median prescription dose delivered by high dose rate brachytherapy was 6 Gy per fraction. PIBS point doses were estimated for each plan and analysed with OriginPro2024b graphing and analysis software. Results: The Mann Whitney test showed statistically significant differences in vaginal doses in terms of percentage of prescription dose (PD) between ICRT and ISBT. Spearman’s rank correlation coefficient (ρ) values indicated that vaginal wall dose and VRL were strongly correlated for FW applicator as compared to MUPIT applicator. Conclusion: Vaginal wall doses in terms of percentage of the PD with MUPIT applicator were found higher than with the FW applicator. Our results suggested that estimation of vaginal doses for each patient was necessary during planning phase in order to avoid the late toxicities.
- 28 May 2026
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 25
Open AccessA comparative study of vaginal doses in intracavitary and template-based interstitial brachytherapy in cancer of cervix patients
Aim: To estimate and compare the vaginal doses in terms of posterior inferior border of symphysis (PIBS) points such as PIBS, PIBS+2, PIBS-2, and vaginal reference length (VRL) for patients of cancer of cervix (CC) treated with intracavitary brachytherapy (ICBT) using Fletcher Williamson applicator (FW) and interstitial brachytherapy (ISBT) using Martinez Universal Perineal Interstitial Template (MUPIT). Material/methods: Treatment plans of a total of 36 consecutive CC patients, who underwent ICBT and ISBT with FW and MUPIT respectively, were retrospectively included in the study. The 3D treatment planning for all the patients had been performed on computed tomography (CT) images. The median prescription dose delivered by high dose rate brachytherapy was 6 Gy per fraction. PIBS point doses were estimated for each plan and analysed with OriginPro2024b graphing and analysis software. Results: The Mann Whitney test showed statistically significant differences in vaginal doses in terms of percentage of prescription dose (PD) between ICRT and ISBT. Spearman’s rank correlation coefficient (ρ) values indicated that vaginal wall dose and VRL were strongly correlated for FW applicator as compared to MUPIT applicator. Conclusion: Vaginal wall doses in terms of percentage of the PD with MUPIT applicator were found higher than with the FW applicator. Our results suggested that estimation of vaginal doses for each patient was necessary during planning phase in order to avoid the late toxicities.
- Open Access
- 1 October 2025
- Published by Wolters Kluwer Health in Indian Journal of Cancer
- Vol. 62 (4) , 565-568
High-dose rate intraluminal brachytherapy in ano-rectum for haemostasis in a case of metastatic infiltrating cancer prostate
Management of rectal bleeding due to various underlying malignant pathologies is a difficult situation, especially in the setting of metastatic disease. Palliative radiation is generally offered to such patients to achieve hemostasis. We report a patient diagnosed with metastatic prostate carcinoma which was infiltrating the rectal mucosa. Fifty-four year old patient, with a case of metastatic prostate carcinoma presented with rectal bleeding. On evaluation, he had a friable growth from the anal verge to 10 cm with severe bleeding. We gave intraluminal high-dose rate brachytherapy using an endoluminal vaginal/rectal cylinder applicator. A dose of 6 Gy, weekly for three weeks was delivered. High-dose-rate brachytherapy was immediately well tolerated. The bleeding stopped completely by day 4 and by day 7 patient was passing yellow stools. Intraluminal high-dose-rate brachytherapy has been proven as an effective palliative treatment in achieving hemostasis from rectal bleeding.
- 1 October 2025
- Published by Wolters Kluwer Health in Indian Journal of Cancer
- Vol. 62 (4) , 565-568
Open AccessHigh-dose rate intraluminal brachytherapy in ano-rectum for haemostasis in a case of metastatic infiltrating cancer prostate
Management of rectal bleeding due to various underlying malignant pathologies is a difficult situation, especially in the setting of metastatic disease. Palliative radiation is generally offered to such patients to achieve hemostasis. We report a patient diagnosed with metastatic prostate carcinoma which was infiltrating the rectal mucosa. Fifty-four year old patient, with a case of metastatic prostate carcinoma presented with rectal bleeding. On evaluation, he had a friable growth from the anal verge to 10 cm with severe bleeding. We gave intraluminal high-dose rate brachytherapy using an endoluminal vaginal/rectal cylinder applicator. A dose of 6 Gy, weekly for three weeks was delivered. High-dose-rate brachytherapy was immediately well tolerated. The bleeding stopped completely by day 4 and by day 7 patient was passing yellow stools. Intraluminal high-dose-rate brachytherapy has been proven as an effective palliative treatment in achieving hemostasis from rectal bleeding.
- 11 September 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 226, 112175
Dosimetric evaluation of Lightning inverse radiation planning and manual forward planning methods in cranial radiosurgery with Gammaknife system
- 11 September 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 226, 112175
Dosimetric evaluation of Lightning inverse radiation planning and manual forward planning methods in cranial radiosurgery with Gammaknife system
- 4 July 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 212, 111425
A method to improve sensitivity of Ferrous ammonium sulfate - Benzoic acid - Xylenol orange (FBX) aqueous radiation dosimeter
- 4 July 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 212, 111425
A method to improve sensitivity of Ferrous ammonium sulfate - Benzoic acid - Xylenol orange (FBX) aqueous radiation dosimeter
- Open Access
- 16 May 2024
- Published by Georg Thieme Verlag KG in Indian Journal of Neurosurgery
- Vol. 13 (03) , 227-232
First Thousand Cases of Intracranial Radiosurgery Treated with Gamma Knife at a Tertiary Care Hospital in India
Purpose We present the profile of first 1,000 cases of intracranial radiosurgery (IRS) treated with Gamma Knife system at a government-funded tertiary care hospital in India. In addition to the information on the indications treated, this study provides an idea of the relevance of the Gamma Knife Radiosurgery (GKRS) for IRS in the fast-changing technological scenario. This study also shows the disease indications for which GKRS was the primary treatment preference. Materials and Methods Leksell Gamma Knife model 4C was used for GKRS. Leksell G-frame-based stereotactic localization was used for all patients. Axial magnetic resonance imaging scans were used for treatment planning with additional two-dimensional angiography images for patients treated for arteriovenus malformations (AVM). The patient population treated with GKRS at our center mainly comprised of patients referred from across the country. Results Acoustic schwannoma formed the largest group of patients (27%) followed by meningioma (21%), AVM (18%), pituitary adenoma (16%), brain metastasis (5.3%), trigeminal neuralgia (3%), cavernoma (2.4%), glomus jugulare (1.8%), craniopharyngioma (1.1%) and “others” (5%). Conclusion The case mix at our center is similar to the overall Indian case mix. However, it is different from the Asian data of 2018 but interestingly similar to the data from Middle East and Africa for 2018. Among the various categories of cranial disorders treated by us, pituitary adenoma tumors had minimum (14/161) and cavernoma tumors had maximum (24/24) proportion of cases managed with GKRS as primary treatment modality.
- 16 May 2024
- Published by Georg Thieme Verlag KG in Indian Journal of Neurosurgery
- Vol. 13 (03) , 227-232
Open AccessFirst Thousand Cases of Intracranial Radiosurgery Treated with Gamma Knife at a Tertiary Care Hospital in India
Purpose We present the profile of first 1,000 cases of intracranial radiosurgery (IRS) treated with Gamma Knife system at a government-funded tertiary care hospital in India. In addition to the information on the indications treated, this study provides an idea of the relevance of the Gamma Knife Radiosurgery (GKRS) for IRS in the fast-changing technological scenario. This study also shows the disease indications for which GKRS was the primary treatment preference. Materials and Methods Leksell Gamma Knife model 4C was used for GKRS. Leksell G-frame-based stereotactic localization was used for all patients. Axial magnetic resonance imaging scans were used for treatment planning with additional two-dimensional angiography images for patients treated for arteriovenus malformations (AVM). The patient population treated with GKRS at our center mainly comprised of patients referred from across the country. Results Acoustic schwannoma formed the largest group of patients (27%) followed by meningioma (21%), AVM (18%), pituitary adenoma (16%), brain metastasis (5.3%), trigeminal neuralgia (3%), cavernoma (2.4%), glomus jugulare (1.8%), craniopharyngioma (1.1%) and “others” (5%). Conclusion The case mix at our center is similar to the overall Indian case mix. However, it is different from the Asian data of 2018 but interestingly similar to the data from Middle East and Africa for 2018. Among the various categories of cranial disorders treated by us, pituitary adenoma tumors had minimum (14/161) and cavernoma tumors had maximum (24/24) proportion of cases managed with GKRS as primary treatment modality.
- Open Access
- 1 January 2023
- Published by Medknow in Journal of Medical Physics
- Vol. 48 (1) , 98-99
International Commission on Radiological Protection Report 152(2022)
- 1 January 2023
- Published by Medknow in Journal of Medical Physics
- Vol. 48 (1) , 98-99
Open AccessInternational Commission on Radiological Protection Report 152(2022)
- Open Access
- 1 October 2022
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 12 (5) , 455-464
Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
Background: Accurate assessment of surface and build-up doses has a key role in radiotherapy, especially for the superficial lesions with uncertainties involved while performing measurements in the build-up region.Objective: This study aimed to assess surface and build-up doses for 6 MV photon beam from linear accelerator using parallel plate ionization chamber, EBT3 Gafchromic films, and PRIMO Monte Carlo (MC) simulation code.Material and Methods: In this experimental study, parallel plate chamber (PPC05) and EBT3 Gafchromic films were used to measure doses in a build-up region for 6 MV beam from the linear accelerator for different field sizes at various depths ranging from 0 to 2 cm from the surface with 100 cm source to surface distance (SSD) in a solid water phantom. Measured results were compared with Monte Carlo simulated results using PENELOPE-based PRIMO simulation code for the same setup conditions. Effect of gantry angle incidence and SSD were also analyzed for depth doses at the surface and build-up regions using PPC05 ion chamber and EBT3 Gafchromic films.Results: Doses measured at the surface were 14.78%, 19.87%, 25.83%, and 31.54% for field sizes of 5×5, 10×10, 15×15, and 20×20 cm2, respectively for a 6 MV photon beam with a parallel plate chamber and 14.20%, 19.14%, 25.149%, and 30.90%, respectively for EBT3 Gafchromic films. Both measurement sets were in good agreement with corresponding simulated results from the PRIMO MC simulation code; doses increase with the increase in field sizes. Conclusion: Good agreement was observed between the measured depth doses using parallel plate ionization chamber, EBT3 Gafchromic films, and the simulated depth doses using PRIMO Monte Carlo simulation code.
- 1 October 2022
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 12 (5) , 455-464
Open AccessAssessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
Background: Accurate assessment of surface and build-up doses has a key role in radiotherapy, especially for the superficial lesions with uncertainties involved while performing measurements in the build-up region.Objective: This study aimed to assess surface and build-up doses for 6 MV photon beam from linear accelerator using parallel plate ionization chamber, EBT3 Gafchromic films, and PRIMO Monte Carlo (MC) simulation code.Material and Methods: In this experimental study, parallel plate chamber (PPC05) and EBT3 Gafchromic films were used to measure doses in a build-up region for 6 MV beam from the linear accelerator for different field sizes at various depths ranging from 0 to 2 cm from the surface with 100 cm source to surface distance (SSD) in a solid water phantom. Measured results were compared with Monte Carlo simulated results using PENELOPE-based PRIMO simulation code for the same setup conditions. Effect of gantry angle incidence and SSD were also analyzed for depth doses at the surface and build-up regions using PPC05 ion chamber and EBT3 Gafchromic films.Results: Doses measured at the surface were 14.78%, 19.87%, 25.83%, and 31.54% for field sizes of 5×5, 10×10, 15×15, and 20×20 cm2, respectively for a 6 MV photon beam with a parallel plate chamber and 14.20%, 19.14%, 25.149%, and 30.90%, respectively for EBT3 Gafchromic films. Both measurement sets were in good agreement with corresponding simulated results from the PRIMO MC simulation code; doses increase with the increase in field sizes. Conclusion: Good agreement was observed between the measured depth doses using parallel plate ionization chamber, EBT3 Gafchromic films, and the simulated depth doses using PRIMO Monte Carlo simulation code.
- Open Access
- 1 April 2021
- Published by Medknow in Journal of Medical Physics
- Vol. 46 (2) , 125-127
Variation in Dosimeter Calibration Factor (NDW) Over a Period of 20 Years
Long delays in renewal of calibration of secondary standards radiation dosimeters in radiation oncology centers due to the COVID19 pandemic have aroused concerns regarding accuracy in dose delivery to patients. The concerns are mainly due to the uncertainty in the absorbed dose to water calibration factor (NDW) over a period of time. In this study, the NDWfactor for two ion chambers, thimble type (Farmer) and parallel plate type (Markus), used in most of the radiotherapy centers, were retrospectively reviewed for 20 years. The calibration on all occasions except once was carried out at the Secondary Standards Dosimetry Laboratory, Bhabha Atomic Research Centre, Mumbai. The change in the NDWfactor over this period was < ±3%. We, therefore, believe that a dosimeter with no history of repairs showed reasonable stability in the NDWfactor over a long period.
- 1 April 2021
- Published by Medknow in Journal of Medical Physics
- Vol. 46 (2) , 125-127
Open AccessVariation in Dosimeter Calibration Factor (NDW) Over a Period of 20 Years
Long delays in renewal of calibration of secondary standards radiation dosimeters in radiation oncology centers due to the COVID19 pandemic have aroused concerns regarding accuracy in dose delivery to patients. The concerns are mainly due to the uncertainty in the absorbed dose to water calibration factor (NDW) over a period of time. In this study, the NDWfactor for two ion chambers, thimble type (Farmer) and parallel plate type (Markus), used in most of the radiotherapy centers, were retrospectively reviewed for 20 years. The calibration on all occasions except once was carried out at the Secondary Standards Dosimetry Laboratory, Bhabha Atomic Research Centre, Mumbai. The change in the NDWfactor over this period was < ±3%. We, therefore, believe that a dosimeter with no history of repairs showed reasonable stability in the NDWfactor over a long period.
- Open Access
- 1 April 2020
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 45 (2) , 134-135
Khan's The Physics of Radiation Therapy
Official publication of Association of Physicists of India
- 1 April 2020
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 45 (2) , 134-135
Open AccessKhan's The Physics of Radiation Therapy
Official publication of Association of Physicists of India