Yvette Naudé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yvette Naudé has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Egmont R. Rohwer
6 shared publicationsEgmont Richard Rohwer
Department of Chemistry, University of Pretoria, Pretoria 0002, South Africa
4 shared publications- Dharini Sivakumar
Phytochemical Food Network, Department of Crop Sciences, Tshwane University of Technology, Pretoria 0001, South Africa
3 shared publications - Egmont Richard Rohwer
University of Pretoria
3 shared publications Egmont Rohwer
Univ Pretoria, Dept Chem, ZA-0002 Hatfield, South Africa
3 shared publicationsLise Korsten
Postharvest Technology Group, Department of Microbiology and Plant Pathology, University of Pretoria, Pretoria 0002, South Africa
3 shared publications
Latest Publications
- Open Access
- 18 November 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1231, 123937
Detection of tuberculosis-associated compounds from human skin by GCxGC-TOFMS
- 18 November 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1231, 123937
Open AccessDetection of tuberculosis-associated compounds from human skin by GCxGC-TOFMS
- Open Access
- 25 November 2022
- Published by Elsevier in Journal of Chromatography Open
- Vol. 2
Identifying foliar volatile organic compounds of Plectranthus and Coleus (Lamiaceae) as predictive markers of genus using GC×GC-TOFMS and machine learning
- 25 November 2022
- Published by Elsevier in Journal of Chromatography Open
- Vol. 2
Open AccessIdentifying foliar volatile organic compounds of Plectranthus and Coleus (Lamiaceae) as predictive markers of genus using GC×GC-TOFMS and machine learning
- 16 May 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (6) , 1-17
Analysis of gaseous polycyclic aromatic hydrocarbon emissions from cooking devices in selected rural and urban kitchens in Bomet and Narok counties of Kenya
Traditional combustion devices and fuels such as charcoal, wood and biomass, are widely utilised in rural and urban households in Africa. Incomplete combustion can generate air pollutants which are of human toxicological importance, including polycyclic aromatic hydrocarbons (PAHs). In this study, portable multi-channel polydimethylsiloxane rubber traps were used to sample gas phase emissions from cooking devices used in urban and rural households in Bomet and Narok counties of Kenya. A wide range of total PAH concentrations was found in samples collected (0.82 – 173.69 µg/m3), which could be attributed to the differences in fuel type, combustion device, climate, and nature of households. Wood combustion using the 3-stone device had the highest average total PAH concentration of ~71 µg/m3. Narok had higher indoor total gas phase PAH concentrations averaging 35.88 µg/m3 in urban and 70.84 µg/m3 in rural households, compared to Bomet county (2.91 µg/m3 in urban and 9.09 µg/m3 in rural households). Ambient total gas phase PAH concentrations were more similar (Narok: 1.26 – 6.28 µg/m3 and Bomet: 2.44 – 6.30 µg/m3). Although the 3-stone device and burning of wood accounted for higher PAH emissions, the charcoal burning jiko stove produced the highest toxic equivalence quotient. Monitoring of PAHs emitted by these cooking devices and fuels is critical to public health and sustainable pollution mitigation.
- 16 May 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (6) , 1-17
Analysis of gaseous polycyclic aromatic hydrocarbon emissions from cooking devices in selected rural and urban kitchens in Bomet and Narok counties of Kenya
Traditional combustion devices and fuels such as charcoal, wood and biomass, are widely utilised in rural and urban households in Africa. Incomplete combustion can generate air pollutants which are of human toxicological importance, including polycyclic aromatic hydrocarbons (PAHs). In this study, portable multi-channel polydimethylsiloxane rubber traps were used to sample gas phase emissions from cooking devices used in urban and rural households in Bomet and Narok counties of Kenya. A wide range of total PAH concentrations was found in samples collected (0.82 – 173.69 µg/m3), which could be attributed to the differences in fuel type, combustion device, climate, and nature of households. Wood combustion using the 3-stone device had the highest average total PAH concentration of ~71 µg/m3. Narok had higher indoor total gas phase PAH concentrations averaging 35.88 µg/m3 in urban and 70.84 µg/m3 in rural households, compared to Bomet county (2.91 µg/m3 in urban and 9.09 µg/m3 in rural households). Ambient total gas phase PAH concentrations were more similar (Narok: 1.26 – 6.28 µg/m3 and Bomet: 2.44 – 6.30 µg/m3). Although the 3-stone device and burning of wood accounted for higher PAH emissions, the charcoal burning jiko stove produced the highest toxic equivalence quotient. Monitoring of PAHs emitted by these cooking devices and fuels is critical to public health and sustainable pollution mitigation.
- 9 September 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (22) , 4202-4215
Non‐invasive sorptive extraction for the separation of human skin surface chemicals using comprehensive gas chromatography coupled to time‐of‐flight mass spectrometry: A mosquito‐host biting site investigation
Variation in inter‐human attractiveness to mosquitoes, and the preference of mosquitoes to bite certain regions on the human host, are possible avenues for identifying lead compounds as potential mosquito attractants or repellents. We report a practical, non‐invasive method for the separation and detection of skin surface chemical compounds and comparison of skin chemical profiles between the ankle and wrist skin surface area sampled over a 5‐day period of a human volunteer using comprehensive gas chromatography coupled to time‐of‐flight mass spectrometry. An in‐house made polydimethylsiloxane passive mini‐sampler, worn as an anklet or a bracelet, was used to concentrate skin volatiles and semi‐volatiles prior to thermal desorption directly in the gas chromatography. A novel method for the addition of an internal standard to sorptive samplers was introduced through solvent modification. This approach enabled a more reliable comparison of human skin surface chemical profiles. Compounds that were closely associated with the wrist included 6‐methyl‐1‐heptanol, 3‐(4‐isopropylphenyl)‐2‐methylpropionaldehyde, 2‐phenoxyethyl isobutyrate, and 2,4,6‐trimethyl‐pyridine. Conversely, compounds only detected on the ankle region included 2‐butoxyethanol phosphate, 2‐heptanone, andp‐menthan‐8‐ol. In addition to known human skin compounds we report two compounds, carvone and (E)‐2‐decenal, not previously reported. Limits of detection ranged from 1 pg (carvone) to 362 pg (indole).
- 9 September 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (22) , 4202-4215
Non‐invasive sorptive extraction for the separation of human skin surface chemicals using comprehensive gas chromatography coupled to time‐of‐flight mass spectrometry: A mosquito‐host biting site investigation
Variation in inter‐human attractiveness to mosquitoes, and the preference of mosquitoes to bite certain regions on the human host, are possible avenues for identifying lead compounds as potential mosquito attractants or repellents. We report a practical, non‐invasive method for the separation and detection of skin surface chemical compounds and comparison of skin chemical profiles between the ankle and wrist skin surface area sampled over a 5‐day period of a human volunteer using comprehensive gas chromatography coupled to time‐of‐flight mass spectrometry. An in‐house made polydimethylsiloxane passive mini‐sampler, worn as an anklet or a bracelet, was used to concentrate skin volatiles and semi‐volatiles prior to thermal desorption directly in the gas chromatography. A novel method for the addition of an internal standard to sorptive samplers was introduced through solvent modification. This approach enabled a more reliable comparison of human skin surface chemical profiles. Compounds that were closely associated with the wrist included 6‐methyl‐1‐heptanol, 3‐(4‐isopropylphenyl)‐2‐methylpropionaldehyde, 2‐phenoxyethyl isobutyrate, and 2,4,6‐trimethyl‐pyridine. Conversely, compounds only detected on the ankle region included 2‐butoxyethanol phosphate, 2‐heptanone, andp‐menthan‐8‐ol. In addition to known human skin compounds we report two compounds, carvone and (E)‐2‐decenal, not previously reported. Limits of detection ranged from 1 pg (carvone) to 362 pg (indole).
- 18 July 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (23) , 5759-5777
Chemical profiling of the human skin surface for malaria vector control via a non-invasive sorptive sampler with GC×GC-TOFMS
Volatile organic compounds (VOCs) and semi-VOCs detected on the human skin surface are of great interest to researchers in the fields of metabolomics, diagnostics, and skin microbiota and in the study of anthropophilic vector mosquitoes. Mosquitoes use chemical cues to find their host, and humans can be ranked for attractiveness to mosquitoes based on their skin chemical profile. Additionally, mosquitoes show a preference to bite certain regions on the human host. In this study, the chemical differences in the skin surface profiles of 20 human volunteers were compared based on inter-human attractiveness to mosquitoes, as well as inter- and intra-human mosquito biting site preference. A passive, non-invasive approach was followed to sample the wrist and ankle skin surface region. An in-house developed polydimethylsiloxane (PDMS) passive sampler was used to concentrate skin VOCs and semi-VOCs prior to thermal desorption directly in the GC inlet with comprehensive gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS). Compounds from a broad range of chemical classes were detected and identified as contributing to the differences in the surface skin chemical profiles. 5-Ethyl-1,2,3,4-tetrahydronaphthalene, 1,1′-oxybisoctane, 2-(dodecyloxy)ethanol, α,α-dimethylbenzene methanol, methyl salicylate, 2,6,10,14-tetramethylhexadecane, 1,2-benzenedicarboxylic acid, bis(2-methylpropyl) ester, 4-methylbenzaldehyde, 2,6-diisopropylnaphthalene, n-hexadecanoic acid, and γ-oxobenzenebutanoic acid ethyl ester were closely associated with individuals who perceived themselves as attractive for mosquitoes. Additionally, biological lead compounds as potential attractants or repellants in vector control strategies were tentatively identified. Results augment current knowledge on human skin chemical profiles and show the potential of using a non-invasive sampling approach to investigate anthropophilic mosquito-host interactions. Graphical abstract
- 18 July 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (23) , 5759-5777
Chemical profiling of the human skin surface for malaria vector control via a non-invasive sorptive sampler with GC×GC-TOFMS
Volatile organic compounds (VOCs) and semi-VOCs detected on the human skin surface are of great interest to researchers in the fields of metabolomics, diagnostics, and skin microbiota and in the study of anthropophilic vector mosquitoes. Mosquitoes use chemical cues to find their host, and humans can be ranked for attractiveness to mosquitoes based on their skin chemical profile. Additionally, mosquitoes show a preference to bite certain regions on the human host. In this study, the chemical differences in the skin surface profiles of 20 human volunteers were compared based on inter-human attractiveness to mosquitoes, as well as inter- and intra-human mosquito biting site preference. A passive, non-invasive approach was followed to sample the wrist and ankle skin surface region. An in-house developed polydimethylsiloxane (PDMS) passive sampler was used to concentrate skin VOCs and semi-VOCs prior to thermal desorption directly in the GC inlet with comprehensive gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS). Compounds from a broad range of chemical classes were detected and identified as contributing to the differences in the surface skin chemical profiles. 5-Ethyl-1,2,3,4-tetrahydronaphthalene, 1,1′-oxybisoctane, 2-(dodecyloxy)ethanol, α,α-dimethylbenzene methanol, methyl salicylate, 2,6,10,14-tetramethylhexadecane, 1,2-benzenedicarboxylic acid, bis(2-methylpropyl) ester, 4-methylbenzaldehyde, 2,6-diisopropylnaphthalene, n-hexadecanoic acid, and γ-oxobenzenebutanoic acid ethyl ester were closely associated with individuals who perceived themselves as attractive for mosquitoes. Additionally, biological lead compounds as potential attractants or repellants in vector control strategies were tentatively identified. Results augment current knowledge on human skin chemical profiles and show the potential of using a non-invasive sampling approach to investigate anthropophilic mosquito-host interactions. Graphical abstract
- Open Access
- 17 February 2020
- Published by Springer Nature in Parasites & Vectors
- Vol. 13 (1) , 1-20
Controlling mosquitoes with semiochemicals: a review
The use of semiochemicals in odour-based traps for surveillance and control of vector mosquitoes is deemed a new and viable component for integrated vector management programmes. Over 114 semiochemicals have been identified, yet implementation of these for management of infectious diseases such as malaria, dengue, chikungunya and Rift Valley fever is still a major challenge. The difficulties arise due to variation in how different mosquito species respond to not only single chemical compounds but also complex chemical blends. Additionally, mosquitoes respond to different volatile blends when they are looking for a mating partner, oviposition sites or a meal. Analytically the challenge lies not only in correctly identifying these semiochemical signals and cues but also in developing formulations that effectively mimic blend ratios that different mosquito species respond to. Only then can the formulations be used to enhance the selectivity and efficacy of odour-based traps. Understanding how mosquitoes use semiochemical cues and signals to survive may be key to unravelling these complex interactions. An overview of the current studies of these chemical messages and the chemical ecology involved in complex behavioural patterns is given. This includes an updated list of the semiochemicals which can be used for integrated vector control management programmes. A thorough understanding of these semiochemical cues is of importance for the development of new vector control methods that can be integrated into established control strategies.
- 17 February 2020
- Published by Springer Nature in Parasites & Vectors
- Vol. 13 (1) , 1-20
Open AccessControlling mosquitoes with semiochemicals: a review
The use of semiochemicals in odour-based traps for surveillance and control of vector mosquitoes is deemed a new and viable component for integrated vector management programmes. Over 114 semiochemicals have been identified, yet implementation of these for management of infectious diseases such as malaria, dengue, chikungunya and Rift Valley fever is still a major challenge. The difficulties arise due to variation in how different mosquito species respond to not only single chemical compounds but also complex chemical blends. Additionally, mosquitoes respond to different volatile blends when they are looking for a mating partner, oviposition sites or a meal. Analytically the challenge lies not only in correctly identifying these semiochemical signals and cues but also in developing formulations that effectively mimic blend ratios that different mosquito species respond to. Only then can the formulations be used to enhance the selectivity and efficacy of odour-based traps. Understanding how mosquitoes use semiochemical cues and signals to survive may be key to unravelling these complex interactions. An overview of the current studies of these chemical messages and the chemical ecology involved in complex behavioural patterns is given. This includes an updated list of the semiochemicals which can be used for integrated vector control management programmes. A thorough understanding of these semiochemical cues is of importance for the development of new vector control methods that can be integrated into established control strategies.
- Open Access
- 1 January 2019
- Published by Academy of Science of South Africa in South African Journal of Chemistry
- Vol. 72 (72) , 55-58
Air Sampling: A Mini-denuder Sampling Device for Direct Desorption in an Inlet of a Gas Chromatograph for the Analyses of Airborne Gaseous Phase Pollutants and Airborne Particulate Phase Pollutants
We introduce a compact mini-denuder air sampling device consisting of a regular gas chromatograph (GC) inlet liner for the simultaneous concentration of separate airborne gaseous and particulate phases in a single-step. Denuder materials are thermally desorbed in a regular inlet of a GC using routine equipment available in any chromatography laboratory. The simplicity of the technique makes it ideal for resource-poor laboratories.
- 1 January 2019
- Published by Academy of Science of South Africa in South African Journal of Chemistry
- Vol. 72 (72) , 55-58
Open AccessAir Sampling: A Mini-denuder Sampling Device for Direct Desorption in an Inlet of a Gas Chromatograph for the Analyses of Airborne Gaseous Phase Pollutants and Airborne Particulate Phase Pollutants
We introduce a compact mini-denuder air sampling device consisting of a regular gas chromatograph (GC) inlet liner for the simultaneous concentration of separate airborne gaseous and particulate phases in a single-step. Denuder materials are thermally desorbed in a regular inlet of a GC using routine equipment available in any chromatography laboratory. The simplicity of the technique makes it ideal for resource-poor laboratories.
- 1 October 2018
- Published by Elsevier in Journal of Chromatography B
- Vol. 1097-1098, 83-93
Human skin volatiles: Passive sampling and GC × GC-ToFMS analysis as a tool to investigate the skin microbiome and interactions with anthropophilic mosquito disease vectors
- 1 October 2018
- Published by Elsevier in Journal of Chromatography B
- Vol. 1097-1098, 83-93
Human skin volatiles: Passive sampling and GC × GC-ToFMS analysis as a tool to investigate the skin microbiome and interactions with anthropophilic mosquito disease vectors
- 1 September 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 984, 107-115
Comparison of a disposable sorptive sampler with thermal desorption in a gas chromatographic inlet, or in a dedicated thermal desorber, to conventional stir bar sorptive extraction-thermal desorption for the determination of micropollutants in water
- 1 September 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 984, 107-115
Comparison of a disposable sorptive sampler with thermal desorption in a gas chromatographic inlet, or in a dedicated thermal desorber, to conventional stir bar sorptive extraction-thermal desorption for the determination of micropollutants in water