GSGungor Sobaci

Gungor Sobaci

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gungor Sobaci has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Acute Pain in the Eye

    by Ugur Acar, Ahmet M. Hondur, Gungor Sobaci

  • The microstructural and functional changes in the macula of heavy habitual smokers

    by Güngör Sobacı, Samir Musayev, Yıldırım Karslıoglu, Fatih Ç. Gündoğan, Gökhan Özge, Üzeyir Erdem, Atilla Bayer


    • 1 February 2013
      • Vol. 10  (1) , 99-105

    Spatial tuning function of pattern visual evoked potentials in multiple sclerosis patients without optic neuritis history.

    by Ahmet Taş, Fatih Cakir Gundogan, Hakan Akgun, Uzeyir Erdem, Gungor Sobaci

    To explore amplitude and latency-check size function in multiple sclerosis (MS) patients without optic neuritis history. Thirty-six MS patients and 21 control subjects were included. Pattern visual evoked responses to ive check sizes (2°, 1°, 30', 15', and 7') were recorded. P100 amplitudes were significantly reduced in 2°, 1° and 7' checks and, P100 latencies were significantly delayed in all checks in MS patients (p < 0.05). Inter-ocular amplitude/ latency differences were significantly higher in MS patients than control group (p < 0.05). The P100 amplitudes for 2° check was somewhat higher than amplitudes for 1° check in MS and control groups. However, MS patients had latter amplitude-check size function curve in large checks. In small checks, the slope of the amplitude-check size curves were similar for MS and control groups. The flattening of amplitude-check size function curve in large checks increased in MS patients with reduced P100 amplitudes. The P100 amplitudes for 2° check was lower than P100 amplitudes for 1° check in MS patients with reduced P100 amplitudes in contrast to normal subjects and MS patients with normal P100 amplitudes. Both groups had almost parallel P100 latency-check size curves in all checks. With respect to 95% confidence limit in control subjects in each check sizes, the number of eyes with delayed latency and reduced amplitude in MS patients were higher in large checks. This study showed that P100 amplitudes are reduced in MS patients without optic neuritis history, and responses to large checks are affected more than small checks.


  • Soccer Ball Related Posterior Segment Closed-Globe Injuries in Outdoor Amateur Players

    by Gokcen Gokce, Osman Melih Ceylan, Fazil Cuneyt Erdurman, Ali Hakan Durukan, Gungor Sobaci

    The aim of this study is to report the characteristics, treatment, and anatomical and functional outcomes of outdoor amateur soccer players with soccer ball-related posterior segment ocular trauma. We conducted a retrospective chart review of 22 patients with diagnoses of closed-globe ocular trauma caused by soccer play activity from 2004 through 2008. Injuries were classified according to Ocular Trauma Classification. All patients (n=22) were male, and all injuries were caused by contact with the soccer ball itself. Sixteen (72%) patients did not require any treatment. Surgery was performed on 5 (22%) patients. Twenty (91%) patients had 5/200 or better visual acuity (VA) at presentation and 2 (9%) had hand movements or worse VA. At the final visit, all patients had 5/200 or better VA (p<0.01). A soccer ball can cause significant posterior segment trauma, and using eye protection equipment might be an appropriate solution.


  • Ocular injuries caused by metal caps of carbonated mineral water bottles

    by Fazil Cuneyt Erdurman, Osman Melih Ceylan, Volkan Hurmeric, Alfrida Pellumbi, Ali Hakan Durukan, Gungor Sobaci

    Bottles containing carbonated drinks are potentially hazardous to the eye. In this study, we aimed to document the clinical characteristics and visual outcomes in a series of patients with ocular injury from flying metal caps of carbonated mineral water bottles. Retrospective review of ocular injuries due to metal caps of carbonated mineral water bottles. Sixteen eyes of sixteen patients were included in the study. All of the patients were male, with a mean age of 24 years. Ten of the patients had a history of using improper tools for bottle cap removal. The left eye was involved in twelve cases and the right eye in four cases. All patients had contusion-type closed-globe injury. Varying degrees of hyphema were observed in all patients, and vitreous hemorrhage was present in four. The visual acuity at the last follow-up was 20/20 in 15 of the patients. The use of a bottle cap opener is essential for preventing ocular damage from pressed metal caps of carbonated drinks. In addition to popularising the use of screw cap bottles, warning labels that alert consumers about the possibility of eye injury should be placed on carbonated drinks with pressed metal caps.


  • The Effect of Chronic Smoking on the Pupil and Photostress Recovery Time

    by Güngör Sobacı, Üzeyir Erdem, Fatih Ç. Gundogan, Samir Musayev

    Purpose: To determine the effect of chronic smoking on the pupil and photostress recovery time. Methods: Macular adaptation to photostress condition, and mesopic and photopic pupillary responses were measured using automated perimetry (Humprey®), and an OPD device (Nidek), respectively. Forty heavy smokers (smoking ≥1 box/day for the past 5 years at least), and 40 age- and sex-matched nonsmokers were enrolled. All the subjects had full vision and no ocular problems. Results: The baseline foveal threshold value (FTV) before photostress was similar in both groups (p = 0.75). Although photostress recovery times (7.1 ± 1.1 and 7.4 ± 1.3 min) were similar in smokers and nonsmokers (p = 0.30), FTV measured at the first minute after photostress was statistically higher in smokers (36.05 ± 0.98 dB) than nonsmokers (34.7 ± 1.03 dB; p = 0.018). Scotopic pupil sizes in smokers (6.73 ± 0.82 mm) and nonsmokers (6.55 ± 0.62 mm) were similar (p = 0.28); however, photopic pupil size in smokers (5.36 ± 0.73 mm) was different from nonsmokers (4.73 ± 0.58 mm; p = 0.001). Conclusions: Chronic smoking may dilate the pupil, and increases macular FTV immediately after photostress.


  • Open Access

    Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening

    by Gungor Sobaci, Gökhan Özge, F C Gundogan

    Purpose: To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors. Methods: Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port® system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects. Results: Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = —0.55, P = 0.004, r = 0.68, P = 0.001, r = —0.65, P = 0.001, and r = —0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001). Conclusion: Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system.


  • Safety and Effectiveness of Interferon Alpha-2a in Treatment of Patients with Behçet's Uveitis Refractory to Conventional Treatments

    by Güngör Sobacı, Üzeyir Erdem, A. Hakan Durukan, Cüneyt Erdurman, Atilla Bayer, Serkan Köksal, Suat Karagul, M. Zeki Bayraktar


  • Toluene Related Toxic Optic Neuropathy

    by Fatih C. Gundogan, Ebru Gorgun, Oguzhan Oz, Fatih M. Mutlu, Gungor Sobaci, Suat Karagul

    Toxic optic neuropathy presenting as bilateral painless visual loss causing central or caecocentral scotoma has a wide differential diagnosis. In this report, we present a rare cause of toxic optic neuropathy presenting as almost indistinct optic disc margins in both eyes in a 30-year old man with blurred vision and difficulty in walking and in writing with a history of adhesive glue sniffing. Caecocentral scotomas in the visual fields; increased total error scores on Farnsworth-Munsell (FM) 100 Hue testing; P100 reduced amplitude in the pattern visually evoked potentials; and N95 reduced amplitude in the pattern electroretinogram associated with normal serum electrolytes and vitamin levels suggested acute toxic optic neuropathy related to toluene. Upon cessation of toluene use, the caecocentral scotomas almost disappeared, total error scores in the FM 100 Hue test decreased and visual acuity improved.


  • Stereoacuity Testing Discloses Abnormalities in Multiple Sclerosis Without Optic Neuritis

    by Güngör Sobaci, Seref Demirkaya, Fatih C Gundogan, Fatih M Mutlu

    Background: We aimed to determine the value of stereoacuity testing in detecting subclinical disease activity in patients with multiple sclerosis (MS) without a history or clinical evidence of optic neuritis. Methods: We enrolled 23 patients with MS and 23 age-matched and sex-matched healthy control subjects with Snellen acuities of 20/20 in both eyes. We recorded monocular pattern visual evoked potentials (PVEPs) to 60-minute and 15-minute check sizes and tested stereoacuity by the Randot stereoacuity (RSA) test. Results: The MS group showed delayed PVEP latencies to 60-minute and 15-minute patterns (P < 0.001 and 0.002). Stereoacuity by the RSA test was significantly worse in patients with MS than in control subjects (P < 0.001). In the MS group, the PVEP P100 latency and the RSA values showed significant positive correlations. There was no significant correlation between the time from MS diagnosis and the RSA and PVEP values. Conclusions: Based on this study, patients with MS without optic neuritis have considerable abnormalities in stereopsis. RSA testing may be a useful marker of subclinical disease activity in this condition.