  • Kinematics of cervical segments C5/C6 in axial rotation before and after total disc arthroplasty

    by Martin Michael Wachowski, Jan Weiland, Markus Wagner, Riccardo Gezzi, Dietmar Kubein-Meesenburg, Hans Nägerl

    The kinematical properties of C5/C6 segments in axial rotation are evaluated before and after total disc arthroplasty (TDA) with PRESTIGE®-and BRYAN® Cervical Disc (Medtronic) under flexion/extension as parameters and compared with those of C3/C4.


  • Does total disc arthroplasty in C3/C4-segments change the kinematic features of axial rotation?

    by Martin Michael Wachowski, Markus Wagner, Jan Weiland, Jochen Dörner, Björn Werner Raab, Henning Dathe, Riccardo Gezzi, Dietmar Kubein-Meesenburg, Hans Nägerl


  • Parametric Control of the Stiffness of Lumbar Segments

    by M. M. Wachowski, M. Mansour, T. Hawallek, D. Kubein‐Meesenburg, J. Hubert, H. Nägerl


    • 1 January 2011
      • Vol. 13  (3) , 35-42

    Construction-conditioned rollback in total knee replacement: fluoroscopic results.

    by Martin Michael Wachowski, Christoph Fiedler, Tim Alexander Walde, Peter Balcarek, Jan Philipp Schüttrumpf, Stephan Frosch, Karl-Heinz Frosch, Jochen Fanghänel, Riccardo Gezzi, Dietmar Kubein-Meesenburg, et al.

    Firstly, the way of implementing approximatively the initial rollback of the natural tibiofemoral joint (TFJ) in a total knee replacement (AEQUOS G1 TKR) is discussed. By configuration of the curvatures of the medial and lateral articulating surfaces a cam gear mechanism with positive drive can be installed, which works under force closure of the femoral and tibial surfaces. Briefly the geometric design features in flexion/extension are described and construction-conditioned kinematical and functional properties that arise are discussed. Due to a positive drive of the cam gear under the force closure during the stance phase of gait the articulating surfaces predominantly roll. As a result of rolling, a sliding friction is avoided, thus the resistance to motion is reduced during the stance phase. Secondly, in vivo fluoroscopic measurements of the patella tendon angle during flexion/extension are presented. The patella tendon angle/ knee flexion angle characteristic and the kinematic profile in trend were similar to those observed in the native knee during gait (0°-60°).


    • 1 January 2010
      • Vol. 12  (4) , 39-47

    Migration of the instantaneous axis of motion during axial rotation in lumbar segments and role of the zygapophysial joints.

    by Martin Michael Wachowski, Thelonius Hawellek, Jan Hubert, Andrea Lehmann, Michael Mansour, Clemens Dumont, Jochen Dörner, Björn Werner Raab, Dietmar Kubein-Meesenburg, Hans Nägerl

    The biomechanical role of the zygapophysial joints was investigated for axial rotations of lumbar segments by recording the positions of the instantaneous helical axis (IHA) against the axial rotational angle and by relating these IHA-positions to anatomical landmarks. Cyclically varying pure axial moments were applied to 3 L1/L2, 7 L3/L4 and 3 L4/L5 segments. There were 800 segment positions per cycle taken by a custom-made high precision 3D-position measuring system. In intact segments IHA-migration reached from one zygapophysial joint to the other IHA-paths came up to 10-60 mm within small angular intervals (±1 deg). After removing the right joints, IHA-migration remained comparable with that of intact segments only for segment positions rotated to the right. Rotation to the left, however, approximately yielded stationary IHA-positions as found after resection of both joints. Hence, IHA-migration is determined by the joints already for small rotational angles. Each type of segment showed a typical pattern of IHA-migration.


    • 1 December 2009
      • p. 61-4

    Axial rotation in the lumbar spine following axial force wrench.

    by M M Wachowski, J Hubert, T Hawellek, M Mansour, J Dorner, D Kubein-Meesenburg, J Fanghanel, B W Raab, B C Dumont, H Nagerl

    The report presents measurements of axial rotation of lumbar motion segments (L1/L2, L3/L4, L4/L5), particularly with small angles of rotation (in the range of +/-1 degrees) following axial force wrenches. The investigation focussed on determining the influence of geometrically varying configurations in axial wrench (consisting of axial torque and axial force) applied on the kinematics (as defined by the migrating instantaneous helical axis, IHA) of lumbar motion segments under constant resulting axial force, and relating IHA-migration to anatomical structures. In all segments, IHA migrated over several centimetres (up to 6 cm). The main portion of IHA-migration was linked to the angle of rotation interval of +/-1 degrees. 3. The shape of the IHA-migration was greatly dependent upon the position of the force line F(z). The-force-wrench-dependent wide IHA-migration found for the rotational angle interval of +/-1 degrees suggests that joint guidance predominates in segment kinematics. The segment kinematics can be adjusted by means of the geometrical configuration of the force wrenches. The design of non-fusion spine implants and FE calculations have to take into consideration joint guidance and muscular force distributions with small intervals of axial rotation.

    • 1 December 2009
      • p. 65-8

    Mechanisms of circumduction and axial rotation of the carpometacarpal joint of the thumb.

    by C Dumont, R Perplies, J Doerner, J Fanghaenel, D Kubein-Meesenburg, M M Wachowski, H Naegerl

    Osteoarthritis of the carpometacarpal joint of the thumb (CMCJ) is a frequent clinical problem. The aim of the study was to discuss the mechanisms of circumduction and axial rotation of the CMCJ considering geometrical properties of the articulating surfaces and the configuration of the muscle system acting over the CMCJ. 28 CMCJ from 7 female and 7 male corpses (age: 81 yrs (median), 53-91 yrs (interval), which did not show any sign of arthrosis, were investigated. Contours in flexion/extension: in saddle point O, the contour of the proximal surface is stronger curved. For 23 of the 28 joints the contours showed an eye-catching difference. Contours in ab-/adduction: all 28 joints showed the respective incongruity. Straight lines and their included angles: in both articulating surfaces, the angles between the straight lines through the saddle point showed values which were close to 90 degrees. Out of neutral position a small axial rotation (maximal range: 3.5 degrees) is possible without that the contact at the saddle points is changed. But, when one of the straight lines of the proximal surface meets a respective straight line of the distal surface, the contact "point" is enlarged to a contact "line". When the axial rotation is further increased, the contact "line" splits into two contacts "points", which are located at outer areas of the articulating surfaces.

    • 1 December 2009
      • p. 69-72

    Knee motion analysis of the non-loaded and loaded knee: a re-look at rolling and sliding.

    by H Nagerl, J Walters, K H Frosch, C Dumont, D Kubein-Meesenburg, J Fanghanel, M M Wachowski

    Many studies of knee motion have been reported in the literature over more than 100 years. Of particular interest to the analysis presented here is the work of the Freeman group, who elegantly measured tibio-femoral kinematics in studies made on cadavers and the knees of living individuals using MRI, anatomical dissection and RSA. We examined and re-evaluated the data collected by Freeman's group and suggest that their conclusion should be considered to be incorrect, since their methods of evaluation were oversimplified from the mathematical and physical perspectives. By applying appropriate methods, however, it is possible to show that the same data yield important insights into physiological knee kinematics and reveal that the rolling-sliding relationship depends on the degree of flexion and on joint load in the medial and lateral compartment, as well. In the initial range of flexion, a considerable amount of rolling was found to occur. Based on this analysis, it is possible to gain useful insights of value for the design of total knee replacements.


  • How do spinal segments move?

    by M.M. Wachowski, M. Mansour, C. Lee, A. Ackenhausen, S. Spiering, J. Fanghänel, C. Dumont, D. Kubein-Meesenburg, H. Nägerl


    • 1 January 2008
      • Vol. 10  (1) , 55-60

    A novel total knee replacement by rolling articulating surfaces. In vivo functional measurements and tests.

    by H Nägerl, K H Frosch, M M Wachowski, C Dumont, C Abicht, P Adam, D Kubein-Meesenburg

    The purposes of the paper were as follows: to show the fundamental functional differences between the natural knee and common total knee replacements (TKR), to describe the ideas on how main properties of the natural knee can be adopted by a novel TKR and to present some main biomechanical functions of this TKR. By analyzing the morphology of the articulating surfaces and the kinematics of the natural knee the design of the novel TKR was developed. The use was made of the test procedures established in vitro and of lateral X-ray photographs as well as fluoroscopy in vivo. The function of the novel TKR is comparable to that of the natural knee joint in terms of kinematics (roll/slide behaviour), loads of the articulating surfaces (diminished shear loads), stability and leeway under external impacts, reduction of the load in the patellofemoral joint, and ligament balancing.