Barry de Goede
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Barry de Goede has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Geert Kazemier
Department of Surgery, VU university medical center, Amsterdam, the Netherlands
2 shared publicationsJohan F. Lange
Department of Surgery, Erasmus Medical Center, University Medical Center Rotterdam, Rotterdam, The Netherlands
2 shared publicationsAlbert Hofman
Department of Epidemiology and Radiology, Erasmus Medical Center, University Medical Center Rotterdam, Rotterdam, The Netherlands
1 shared publicationB J H van Kempen
Department of Epidemiology and Radiology, Erasmus University Medical Centre, Rotterdam, The Netherlands
1 shared publicationB. J. H. van Kempen
Erasmus MC, University Medical Center Rotterdam
1 shared publicationBob J. van Kempen
Department of Epidemiology, Erasmus University Medical Center, Rotterdam, The Netherlands
1 shared publication
Latest Publications
- 1 March 2015
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 220 (3) , 347-352
Very Low Birth Weight Is an Independent Risk Factor for Emergency Surgery in Premature Infants with Inguinal Hernia
Common surgical knowledge is that inguinal hernia repair in premature infants should be postponed until they reach a certain weight or age. Optimal management, however, is still under debate. The objective of this study was to collect evidence for the optimal management of inguinal hernia repair in premature infants. In the period between 2010 and 2013, data for all premature infants with inguinal hernia who underwent hernia correction within 3 months after birth in the Erasmus MC-Sophia Children's Hospital, Rotterdam were analyzed. Primary outcomes measures were the incidences of incarceration and subsequent emergency surgery. In a multivariate analysis, Cox proportional hazards model served to identify independent risk factors for incarceration requiring an emergency procedure. A total of 142 premature infants were included in the analysis. Median follow-up was 28 months (range 15 to 39 months). Seventy-nine premature infants (55.6%) presented with a symptomatic inguinal hernia; emergency surgery was performed in 55.7%. Complications occurred in 27.3% of emergency operations vs 10.2% after elective repair; recurrences occurred in 13.6% vs 2.0%, respectively. Very low birth weight (≤1,500 g) was an independent risk factor for emergency surgery, with a hazard ratio of 2.7 in the Cox proportional hazards model. More than half of premature infants with an inguinal hernia have incarceration. Those with very low birth weight have a 3-fold greater risk of requiring an emergency procedure than heavier premature infants. Emergency repair results in higher recurrence rates and more complications. Elective hernia repair is recommended, particularly in very low birth weight premature infants.
- 1 March 2015
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 220 (3) , 347-352
Very Low Birth Weight Is an Independent Risk Factor for Emergency Surgery in Premature Infants with Inguinal Hernia
Common surgical knowledge is that inguinal hernia repair in premature infants should be postponed until they reach a certain weight or age. Optimal management, however, is still under debate. The objective of this study was to collect evidence for the optimal management of inguinal hernia repair in premature infants. In the period between 2010 and 2013, data for all premature infants with inguinal hernia who underwent hernia correction within 3 months after birth in the Erasmus MC-Sophia Children's Hospital, Rotterdam were analyzed. Primary outcomes measures were the incidences of incarceration and subsequent emergency surgery. In a multivariate analysis, Cox proportional hazards model served to identify independent risk factors for incarceration requiring an emergency procedure. A total of 142 premature infants were included in the analysis. Median follow-up was 28 months (range 15 to 39 months). Seventy-nine premature infants (55.6%) presented with a symptomatic inguinal hernia; emergency surgery was performed in 55.7%. Complications occurred in 27.3% of emergency operations vs 10.2% after elective repair; recurrences occurred in 13.6% vs 2.0%, respectively. Very low birth weight (≤1,500 g) was an independent risk factor for emergency surgery, with a hazard ratio of 2.7 in the Cox proportional hazards model. More than half of premature infants with an inguinal hernia have incarceration. Those with very low birth weight have a 3-fold greater risk of requiring an emergency procedure than heavier premature infants. Emergency repair results in higher recurrence rates and more complications. Elective hernia repair is recommended, particularly in very low birth weight premature infants.
- 23 June 2013
- Published by Springer Nature in Hernia
- Vol. 17 (4) , 515-519
Umbilical hernia management during liver transplantation
Patients with liver cirrhosis scheduled for liver transplantation often present with a concurrent umbilical hernia. Optimal management of these patients is not clear. The objective of this study was to compare the outcomes of patients who underwent umbilical hernia correction during liver transplantation through a separate infra-umbilical incision with those who underwent correction through the same incision used to perform the liver transplantation. In the period between 1990 and 2011, all 27 patients with umbilical hernia and liver cirrhosis who underwent hernia correction during liver transplantation were identified in our hospital database. In 17 cases, umbilical hernia repair was performed through a separate infra-umbilical incision (separate incision group) and 10 were corrected from within the abdominal cavity without a separate incision (same incision group). Six patients died during follow-up; no deaths were attributable to intraoperative umbilical hernia repair. All 21 patients who were alive visited the outpatient clinic to detect recurrent umbilical hernia. One recurrent umbilical hernia was diagnosed in the separate incision group (6 %) and four (40 %) in the same incision group (p = 0.047). Two patients in the same incision group required repair of the recurrent umbilical hernia; one of whom underwent emergency surgery for bowel incarceration. The one recurrent hernia in the separate incision group was corrected electively. In the event of liver transplantation, umbilical hernia repair through a separate infra-umbilical incision is preferred over correction through the same incision used to perform the transplantation.
- 23 June 2013
- Published by Springer Nature in Hernia
- Vol. 17 (4) , 515-519
Umbilical hernia management during liver transplantation
Patients with liver cirrhosis scheduled for liver transplantation often present with a concurrent umbilical hernia. Optimal management of these patients is not clear. The objective of this study was to compare the outcomes of patients who underwent umbilical hernia correction during liver transplantation through a separate infra-umbilical incision with those who underwent correction through the same incision used to perform the liver transplantation. In the period between 1990 and 2011, all 27 patients with umbilical hernia and liver cirrhosis who underwent hernia correction during liver transplantation were identified in our hospital database. In 17 cases, umbilical hernia repair was performed through a separate infra-umbilical incision (separate incision group) and 10 were corrected from within the abdominal cavity without a separate incision (same incision group). Six patients died during follow-up; no deaths were attributable to intraoperative umbilical hernia repair. All 21 patients who were alive visited the outpatient clinic to detect recurrent umbilical hernia. One recurrent umbilical hernia was diagnosed in the separate incision group (6 %) and four (40 %) in the same incision group (p = 0.047). Two patients in the same incision group required repair of the recurrent umbilical hernia; one of whom underwent emergency surgery for bowel incarceration. The one recurrent hernia in the separate incision group was corrected electively. In the event of liver transplantation, umbilical hernia repair through a separate infra-umbilical incision is preferred over correction through the same incision used to perform the transplantation.
- 22 February 2013
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 100 (6) , 735-742
Meta-analysis of glue versus sutured mesh fixation for Lichtenstein inguinal hernia repair
Background: Chronic pain remains a frequent complication after Lichtenstein inguinal hernia repair. As a consequence, mesh fixation using glue instead of sutures has become popular. This meta-analysis aimed to clarify which fixation technique is to be preferred for elective Lichtenstein inguinal hernia repair. Methods: A meta-analysis was conducted according to the PRISMA guidelines. Articles published between January 1990 and April 2012 were searched for in MEDLINE, Embase and the Cochrane Library. Randomized controlled trials (RCTs) comparing glue and sutured mesh fixation in elective Lichtenstein repair for unilateral inguinal hernia were included. The quality of the RCTs and the potential risk of bias were assessed using the Cochrane risk of bias tool. Results: Of 254 papers found in the initial search, a meta-analysis was conducted of seven RCTs comprising 1185 patients. With the use of glue mesh fixation, the duration of operation was shorter (mean difference −2·57 (95 per cent confidence interval (c.i.) –4·88 to −0·26) min; P = 0·03), patients had lower visual analogue scores for postoperative pain (mean difference −0·75 (−1·18 to −0·33); P = 0·001), early chronic pain occurred less often (risk ratio 0·52, 95 per cent c.i. 0·31 to 0·87; P = 0·01), and time to return to daily activities was shorter (mean difference −1·17 (−2·30 to −0·03) days; P = 0·04). The hernia recurrence rate did not differ significantly. Conclusion: Elective Lichtenstein repair for inguinal hernia using glue mesh fixation compared with sutures is faster and less painful, with comparable hernia recurrence rates.
- 22 February 2013
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 100 (6) , 735-742
Meta-analysis of glue versus sutured mesh fixation for Lichtenstein inguinal hernia repair
Background: Chronic pain remains a frequent complication after Lichtenstein inguinal hernia repair. As a consequence, mesh fixation using glue instead of sutures has become popular. This meta-analysis aimed to clarify which fixation technique is to be preferred for elective Lichtenstein inguinal hernia repair. Methods: A meta-analysis was conducted according to the PRISMA guidelines. Articles published between January 1990 and April 2012 were searched for in MEDLINE, Embase and the Cochrane Library. Randomized controlled trials (RCTs) comparing glue and sutured mesh fixation in elective Lichtenstein repair for unilateral inguinal hernia were included. The quality of the RCTs and the potential risk of bias were assessed using the Cochrane risk of bias tool. Results: Of 254 papers found in the initial search, a meta-analysis was conducted of seven RCTs comprising 1185 patients. With the use of glue mesh fixation, the duration of operation was shorter (mean difference −2·57 (95 per cent confidence interval (c.i.) –4·88 to −0·26) min; P = 0·03), patients had lower visual analogue scores for postoperative pain (mean difference −0·75 (−1·18 to −0·33); P = 0·001), early chronic pain occurred less often (risk ratio 0·52, 95 per cent c.i. 0·31 to 0·87; P = 0·01), and time to return to daily activities was shorter (mean difference −1·17 (−2·30 to −0·03) days; P = 0·04). The hernia recurrence rate did not differ significantly. Conclusion: Elective Lichtenstein repair for inguinal hernia using glue mesh fixation compared with sutures is faster and less painful, with comparable hernia recurrence rates.