Ofer Levi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ofer Levi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
James S. Harris
Solid State and Photonics Laboratory, Stanford University, Stanford, CA 94305, USA
2 shared publications- James S. Harris
Department of Electrical Engineering, Stanford University, Stanford, CA, 94305, USA
2 shared publications - Jianhua Cang
Department of Physiology, University of California, San Francisco, 94143 USA
2 shared publications - Krishna V. Shenoy
Department of Electrical Engineering, Stanford University, Stanford, USA
2 shared publications - Megumi Kaneko
Department of Physiology, University of California, San Francisco, 94143 USA
2 shared publications Meredith M. Lee
Solid State and Photonics Laboratory, Stanford University, Stanford, CA 94305, USA
2 shared publications
Latest Publications
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Optical Characterization and Sensitivity Evaluation of Guided-Resonances in Photonic Crystal Slabs for Biosensing Applications
Optical characterization and sensitivity evaluation of an all-dielectric photonic crystal based guided resonance filter sensitive to index-of-refraction changes in aqueous solutions is presented. Measured quality factor values (Q=83, 181) correspond to detectable index-change of 2times10-3.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Optical Characterization and Sensitivity Evaluation of Guided-Resonances in Photonic Crystal Slabs for Biosensing Applications
Optical characterization and sensitivity evaluation of an all-dielectric photonic crystal based guided resonance filter sensitive to index-of-refraction changes in aqueous solutions is presented. Measured quality factor values (Q=83, 181) correspond to detectable index-change of 2times10-3.
- 13 March 2007
- Published by Optica Publishing Group in Applied Optics
- Vol. 46 (10) , 1881-1889
Integrated semiconductor optical sensors for cellular and neural imaging.
We review integrated optical sensors for functional brain imaging, localized index-of-refraction sensing as part of a lab-on-a-chip, and in vivo continuous monitoring of tumor and cancer stem cells. We present semiconductor-based sensors and imaging systems for these applications. Measured intrinsic optical signals and tissue optics simulations indicate the need for high dynamic range and low dark-current neural sensors. Simulated and measured reflectance spectra from our guided resonance filter demonstrate the capability for index-of-refraction sensing on cellular scales, compatible with integrated biosensors. Finally, we characterized a thermally evaporated emission filter that can be used to improve sensitivity for in vivo fluorescence sensing.
- 13 March 2007
- Published by Optica Publishing Group in Applied Optics
- Vol. 46 (10) , 1881-1889
Integrated semiconductor optical sensors for cellular and neural imaging.
We review integrated optical sensors for functional brain imaging, localized index-of-refraction sensing as part of a lab-on-a-chip, and in vivo continuous monitoring of tumor and cancer stem cells. We present semiconductor-based sensors and imaging systems for these applications. Measured intrinsic optical signals and tissue optics simulations indicate the need for high dynamic range and low dark-current neural sensors. Simulated and measured reflectance spectra from our guided resonance filter demonstrate the capability for index-of-refraction sensing on cellular scales, compatible with integrated biosensors. Finally, we characterized a thermally evaporated emission filter that can be used to improve sensitivity for in vivo fluorescence sensing.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 1025-1028
Integrated Semiconductor Optical Sensors for Chronic, Minimally-Invasive Imaging of Brain Function
Intrinsic optical signal (IOS) imaging is a widely accepted technique for imaging brain activity. We propose an integrated device consisting of interleaved arrays of gallium arsenide (GaAs) based semiconductor light sources and detectors operating at telecommunications wavelengths in the near-infrared. Such a device will allow for long-term, minimally invasive monitoring of neural activity in freely behaving subjects, and will enable the use of structured illumination patterns to improve system performance. In this work we describe the proposed system and show that near-infrared IOS imaging at wavelengths compatible with semiconductor devices can produce physiologically significant images in mice, even through skull
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 1025-1028
Integrated Semiconductor Optical Sensors for Chronic, Minimally-Invasive Imaging of Brain Function
Intrinsic optical signal (IOS) imaging is a widely accepted technique for imaging brain activity. We propose an integrated device consisting of interleaved arrays of gallium arsenide (GaAs) based semiconductor light sources and detectors operating at telecommunications wavelengths in the near-infrared. Such a device will allow for long-term, minimally invasive monitoring of neural activity in freely behaving subjects, and will enable the use of structured illumination patterns to improve system performance. In this work we describe the proposed system and show that near-infrared IOS imaging at wavelengths compatible with semiconductor devices can produce physiologically significant images in mice, even through skull
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 1025-1028
Integrated Semiconductor Optical Sensors for Chronic, Minimally-Invasive Imaging of Brain Function
Intrinsic optical signal (IOS) imaging is a widely accepted technique for imaging brain activity. We propose an integrated device consisting of interleaved arrays of gallium arsenide (GaAs) based semiconductor light sources and detectors operating at telecommunications wavelengths in the near-infrared. Such a device will allow for long-term, minimally invasive monitoring of neural activity in freely behaving subjects, and will enable the use of structured illumination patterns to improve system performance. In this work we describe the proposed system and show that near-infrared IOS imaging at wavelengths compatible with semiconductor devices can produce physiologically significant images in mice, even through skull
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 1025-1028
Integrated Semiconductor Optical Sensors for Chronic, Minimally-Invasive Imaging of Brain Function
Intrinsic optical signal (IOS) imaging is a widely accepted technique for imaging brain activity. We propose an integrated device consisting of interleaved arrays of gallium arsenide (GaAs) based semiconductor light sources and detectors operating at telecommunications wavelengths in the near-infrared. Such a device will allow for long-term, minimally invasive monitoring of neural activity in freely behaving subjects, and will enable the use of structured illumination patterns to improve system performance. In this work we describe the proposed system and show that near-infrared IOS imaging at wavelengths compatible with semiconductor devices can produce physiologically significant images in mice, even through skull