Friedrich-Christian Riess
Research Subjects
Friedrich-Christian Riess has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Lorenz Hansen
Clinic of Cardiac Surgery and Clinic of Cardiology, Albertinen Cardiovascular Center, Hamburg, Germany
4 shared publicationsNiels Bleese
Albertinen Heart Center, Hamburg, Germany
4 shared publicationsRalf Bader
4 shared publicationsEva Cramer
3 shared publications- Joachim Schofer
Medical Care Center Prof. Mathey, Prof. Schofer, Hamburg University Cardiovascular Center, Hamburg, Germany
3 shared publications Jürgen Wallrath
3 shared publications
Latest Publications
- 1 March 2018
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 105 (3) , 763-769
Long-Term Outcomes of the Mosaic Bioprosthesis
- 1 March 2018
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 105 (3) , 763-769
Long-Term Outcomes of the Mosaic Bioprosthesis
- 25 September 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 52 (5) , 917-923
Complete arterial revascularization using bilateral internal mammary artery in T-graft technique for multivessel coronary artery disease in on- or off-pump approach: does gender lose its historical impact on clinical outcome?
Higher rates of mortality and morbidity have been reported in women undergoing coronary artery bypass grafting (CABG) compared with men. Different revascularization techniques (on-pump and off-pump) might influence this outcome. We retrospectively analysed 3445 consecutively recruited patients (all comers) undergoing complete arterial CABG (CACABG) at a single centre between January 2000 and December 2012. CACABG was performed in all patients using bilateral skeletonized internal mammary artery in T-graft technique, either on-pump (n = 2216) or off-pump (n = 1229). Early results (30-day) and long-term follow-up data were analysed with respect to gender-specific outcome. Women were older than men in both groups (P < 0.001), and men had a higher body mass index (on-pump: P < 0.001; off-pump: P = 0.02) compared with women. Men displayed a higher extent of coronary artery disease (P < 0.001) and an overall lower ejection fraction (P < 0.001) when undergoing on-pump CABG. No gender differences were observed for late survival (P = 0.74 vs P = 0.52) in on-pump and off-pump procedures, respectively. Late follow-up revealed a higher rate of FitzGibbon A graft patency in men undergoing the on-pump approach (P = 0.006). CACABG using bilateral internal mammary artery in T-graft technique showed excellent early and long-term results. No significant gender-specific differences were observed in both groups undergoing CACABG with respect to 30 days mortality and morbidity as well as late survival. However, late follow-up revealed a higher graft patency in men undergoing the on-pump approach, compared to women.
- 25 September 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 52 (5) , 917-923
Complete arterial revascularization using bilateral internal mammary artery in T-graft technique for multivessel coronary artery disease in on- or off-pump approach: does gender lose its historical impact on clinical outcome?
Higher rates of mortality and morbidity have been reported in women undergoing coronary artery bypass grafting (CABG) compared with men. Different revascularization techniques (on-pump and off-pump) might influence this outcome. We retrospectively analysed 3445 consecutively recruited patients (all comers) undergoing complete arterial CABG (CACABG) at a single centre between January 2000 and December 2012. CACABG was performed in all patients using bilateral skeletonized internal mammary artery in T-graft technique, either on-pump (n = 2216) or off-pump (n = 1229). Early results (30-day) and long-term follow-up data were analysed with respect to gender-specific outcome. Women were older than men in both groups (P < 0.001), and men had a higher body mass index (on-pump: P < 0.001; off-pump: P = 0.02) compared with women. Men displayed a higher extent of coronary artery disease (P < 0.001) and an overall lower ejection fraction (P < 0.001) when undergoing on-pump CABG. No gender differences were observed for late survival (P = 0.74 vs P = 0.52) in on-pump and off-pump procedures, respectively. Late follow-up revealed a higher rate of FitzGibbon A graft patency in men undergoing the on-pump approach (P = 0.006). CACABG using bilateral internal mammary artery in T-graft technique showed excellent early and long-term results. No significant gender-specific differences were observed in both groups undergoing CACABG with respect to 30 days mortality and morbidity as well as late survival. However, late follow-up revealed a higher graft patency in men undergoing the on-pump approach, compared to women.
- 18 October 2013
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 28 (1) , 21-23
„Off-pump“-Verfahren
- 18 October 2013
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 28 (1) , 21-23
„Off-pump“-Verfahren
- 1 April 2012
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 93 (4) , 1319
Fibrous Cyst Arising From the Cordae Tendiniae of the Mitral Valve
- 1 April 2012
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 93 (4) , 1319
Fibrous Cyst Arising From the Cordae Tendiniae of the Mitral Valve
- 1 June 2011
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 141 (6) , 1440-1448.e1
The Mosaic porcine bioprosthesis: Role of age on clinical performance in aortic position
- 1 June 2011
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 141 (6) , 1440-1448.e1
The Mosaic porcine bioprosthesis: Role of age on clinical performance in aortic position
- 31 January 2011
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 91 (1) , e5-e7
Aortic Valve Replacement After Transapical Valve-in-Valve Implantation
- 31 January 2011
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 91 (1) , e5-e7
Aortic Valve Replacement After Transapical Valve-in-Valve Implantation
- 1 January 2010
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 37 (1) , 145-153
Clinical results of the Medtronic Mosaic porcine bioprosthesis up to 13 years
The Mosaic bioprosthesis is a third-generation stented porcine bioprosthesis combining physiologic fixation and alpha-amino oleic acid (AOA) antimineralisation treatment to improve haemodynamic performance and durability. This single-centre study reports the clinical results, including haemodynamic performance, of the Mosaic bioprosthesis after implant in aortic or mitral position. Between February 1994 and October 1999, 255 patients with aortic valve replacement (AVR; mean age: 67 years, range: 23-82 years) and 47 patients with mitral valve replacement (MVR; mean age: 67 years, range: 41-84 years) were enrolled in this prospective non-randomised clinical trial. Follow-up visits were performed 30 days and 6 months after implant and annually thereafter. The cumulative follow-up was 1976.2 patient-years (pt-yrs) after AVR (median: 8.3 years, maximum: 14.0 years) and 336.9 pt-yrs after mitral valve replacement (MVR) (median: 8.2 years, maximum: 13.3 years). After AVR, mean systolic gradient and effective orifice area at 4, 8 and 13 years follow-up were 13.3+/-5.6, 15.5+/-7.7 and 16.0+/-7.2 mmHg and 1.8+/-0.5, 1.8+/-0.5 and 1.7+/-0.4 cm(2). After MVR, respective data were 4.7+/-2.1, 4.3+/-1.2 and 5.0 mmHg (only one recording) and 2.2+/-0.7, 2.3+/-0.6 and 1.8 cm(2). Transvalvular regurgitation at 13-year follow-up was mild or less in both the AVR and MVR patients. Thirteen-year survival was 63.1+/-4.5% in the AVR group and 51.2+/-13.6% in the MVR group. Early mortality after AVR and MVR was 1.2% and 0.0%, respectively; late mortality was 3.2%pt-yr(-1) and 3.3%pt-yr(-1), including a valve-related/unexplained mortality of 1.1%pt-yr(-1) and 0.9%pt-yr(-1). Freedom from adverse events in the AVR and MVR group was permanent neurological event: 97.4+/-1.2% and 96.0+/-3.9%; valvular thrombosis: 97.8+/-1.1% and 100%; structural valve deterioration: 84.8+/-7.8% and 93.8+/-6.1%; explant: 73.3+/-7.3% and 89.3+/-6.5%. The Mosaic bioprosthesis demonstrates excellent clinical performance and safety after 13 years of follow-up. Continued follow-up will determine whether this new design will provide increased durability.
- 1 January 2010
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 37 (1) , 145-153
Clinical results of the Medtronic Mosaic porcine bioprosthesis up to 13 years
The Mosaic bioprosthesis is a third-generation stented porcine bioprosthesis combining physiologic fixation and alpha-amino oleic acid (AOA) antimineralisation treatment to improve haemodynamic performance and durability. This single-centre study reports the clinical results, including haemodynamic performance, of the Mosaic bioprosthesis after implant in aortic or mitral position. Between February 1994 and October 1999, 255 patients with aortic valve replacement (AVR; mean age: 67 years, range: 23-82 years) and 47 patients with mitral valve replacement (MVR; mean age: 67 years, range: 41-84 years) were enrolled in this prospective non-randomised clinical trial. Follow-up visits were performed 30 days and 6 months after implant and annually thereafter. The cumulative follow-up was 1976.2 patient-years (pt-yrs) after AVR (median: 8.3 years, maximum: 14.0 years) and 336.9 pt-yrs after mitral valve replacement (MVR) (median: 8.2 years, maximum: 13.3 years). After AVR, mean systolic gradient and effective orifice area at 4, 8 and 13 years follow-up were 13.3+/-5.6, 15.5+/-7.7 and 16.0+/-7.2 mmHg and 1.8+/-0.5, 1.8+/-0.5 and 1.7+/-0.4 cm(2). After MVR, respective data were 4.7+/-2.1, 4.3+/-1.2 and 5.0 mmHg (only one recording) and 2.2+/-0.7, 2.3+/-0.6 and 1.8 cm(2). Transvalvular regurgitation at 13-year follow-up was mild or less in both the AVR and MVR patients. Thirteen-year survival was 63.1+/-4.5% in the AVR group and 51.2+/-13.6% in the MVR group. Early mortality after AVR and MVR was 1.2% and 0.0%, respectively; late mortality was 3.2%pt-yr(-1) and 3.3%pt-yr(-1), including a valve-related/unexplained mortality of 1.1%pt-yr(-1) and 0.9%pt-yr(-1). Freedom from adverse events in the AVR and MVR group was permanent neurological event: 97.4+/-1.2% and 96.0+/-3.9%; valvular thrombosis: 97.8+/-1.1% and 100%; structural valve deterioration: 84.8+/-7.8% and 93.8+/-6.1%; explant: 73.3+/-7.3% and 89.3+/-6.5%. The Mosaic bioprosthesis demonstrates excellent clinical performance and safety after 13 years of follow-up. Continued follow-up will determine whether this new design will provide increased durability.