KGK. Le Guen

K. Le Guen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


K. Le Guen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Catalin Miron

    Université Paris-Saclay, CEA, CNRS, LIDYL, 91191 Gif-sur-Yvette, France

    3 shared publications
  • Marc Simon

    Sorbonne Universite

    3 shared publications
  • P. Morin

    Atomes et Molécules DSM/DRECAM/SPAM Laboratoire Francis Perrin, CNRS-URA 2453, Service des Photons CEA Saclay, Bâtiment 522, F-91191 Gif-sur-Yvette Cedex, France and , L’orme des Merisiers, St. Aubin, BP 48, F-91192 Gif-sur-Yvette Cedex, France

    3 shared publications
  • D. Céolin

    Uppsala University Department of Physics P.O. Box 530, S-75121 Uppsala, Sweden and MAX-lab P.O. Box 118, S-22100 Lund, Sweden

    2 shared publications
  • N. Leclercq

    Atomes et Molécules DSM/DRECAM/SPAM Laboratoire Francis Perrin, CNRS-URA 2453, Service des Photons CEA Saclay, Bâtiment 522, F-91191 Gif-sur-Yvette Cedex, France and , L’orme des Merisiers, St. Aubin, BP 48, F-91192 Gif-sur-Yvette Cedex, France

    2 shared publications
  • Alexandra Mocellin

    Institute of Physics University of Brasília Campus Darcy Ribeiro, Asa Norte Brasília-DF Brazil 70919-970

    1 shared publication

Latest Publications

  • H 2 S ultrafast dissociation probed by energy-selected resonant Auger electron–ion coincidence measurements

    by K. Le Guen, C. Miron, D. Céolin, R. Guillemin, N. Leclercq, M. Simon, P. Morin, A. Mocellin, O. Björneholm, A. Naves de Brito, et al.

    We have studied the ultrafast dissociation of the H2S molecule upon S 2p3∕2→6a1 inner-shell excitation by combining high-resolution resonant Auger spectroscopy and energy-selected Auger electron–ion coincidence measurements. Auger final states have been correlated to the different fragmentation pathways (S+, HS+, and H2S+ ions). As an original result, we evidence a three-step mechanism to describe the resonant production of S+: the Auger recombination in the HS* fragment is followed for the AΠ3 and cΠ1 states by the S++H fragmentation mechanism.


  • Influence of formation path on the CH2BrCl2+ dissociation dynamics

    by K. Le Guen, M. Ahmad, D. Céolin, P. Lablanquie, C. Miron, F. Penent, P. Morin, M. Simon

    To get further insight into the CH2BrCl site-selective fragmentation previously observed upon inner-shell ionization, we have performed high-resolution Br 3d and Cl 2p Auger and spin-orbit resolved Br 3d Auger spectra, and studied the dissociation properties of the CH2BrCl2+ dication formed at threshold by means of threshold electron pair-ion coincidence measurements. The key point is that the origin of site-specific bond breaking is found in the Auger decay itself, as it preferentially populates selected dication states. Whereas the predominance of the CBr bond breaking is observed in both threshold and inner-shell studies, no signature of selective CCl rupture is reported for the dication formed at threshold.


  • New setup for angular distribution measurements of Auger electrons from fixed in space molecules

    by R. Guillemin, E. Shigemasa, K. Le Guen, D. Ceolin, C. Miron, N. Leclercq, K. Ueda, P. Morin, M. Simon

    A new experimental setup for measurement of the angular distributions of energy selected Auger electrons emitted from fixed in space molecules is presented. The system is based on two identical ion detectors with a small angular acceptance placed at 0° and 90° relative to the polarization axis of the incident radiation, and a high luminosity double-toroidal electron analyzer combined with position sensitive detection. This setup allows selection of the molecular alignment for σ and π ionization channels simultaneously and provides an energy and ejection angle measurement of the outgoing electron. The performance in terms of energy and angular resolution, as well as the calibration procedure, are discussed. Sample results obtained on the carbon monoxide ionized above the C 1s threshold are presented.