PBPaul E. Bigeleisen

Paul E. Bigeleisen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paul E. Bigeleisen has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultrasound-guided Supraclavicular Block: What Is Intraneural?

    by Paul E. Bigeleisen, Gerbrand Groen, Nizar Moayeri

    We thank Drs. Morfey and Brull for their response to our recent observations.1 They raise some important questions on the ability of minimum stimulating current to detect intraneural needle placement and to predict neurologic injury after intraneural injection. Their most important question, however, concerned the reliability of our measurements: how sure are we that the needle tip was outside and inside the nerve during extraneural and intraneural measurements, respectively? Their question concerning what would be the outer layer of the supraclavicular brachial plexus is very reasonable. In their ultrasound-guided supraclavicular block procedure, accompanied by figures before and after injection, they describe that during the block this outer layer is intentionally breached, which is often felt as a loss of resistance or “pop.”


  • In Vitro Evaluation of a Micro-Doppler Catheter for Detection and Aspiration of Venous Air Emboli

    by Paul E. Bigeleisen

    Venous air embolism (VAE) is a potentially fatal complication of surgery when open veins at a surgical site are exposed to ambient air pressure which exceeds the pressure in the venous system. Common techniques of detecting VAE are precordial Doppler monitoring and transesophogeal echocardiography. Precordial Doppler monitoring has poor accuracy and transesophogeal echocardiography is expensive and user-intensive. In both methods, a separate catheter must be inserted into the vena cava so that an embolus may be aspirated if it is detected. We created a micro-Doppler assembly using two ceramic transducers fitted over a 5.8F multiorifice central venous catheter. This micro-Doppler catheter (MDC) was tested in vitro using a static tank and an artificial vena cava (AVC). The MDC was also tested for acoustic pressure and current leakage in the static tank and for heat generation and cavitation in the AVC. The MDC was able to detect bubbles more than 2 mm in diameter with 100% accuracy. A blinded observer was able to identify the onset of vapor lock in 10 of 10 trials. The same observer was able to terminate vapor lock in 10 of 10 trials. The acoustic pressures measured were <1.8 MPa. There was no increase in temperature in the AVC over 24 h and there was no evidence of cavitation in the AVC over 4 h. We have created a MDC that can detect air emboli and relieve vapor lock in a simulated vena cava and atrium. This catheter could be placed percutaneously in the vena cava. Based on the measurements of acoustic pressure, temperature in the AVC and lack of cavitation in the AVC, the device appears to be safe for use in humans. More studies are required to determine if the catheter could be used to detect and aspirate VAE during surgeries where VAE is likely, such as sitting craniotomy.

  • Evidence of Nerve Puncture during Ultrasound-guided Peripheral Nerve Blocks

    by Paul Bigeleisen

    I appreciate the thoughtful comments about my article titled “Nerve Puncture and Apparent Intraneural Injection during Ultrasound-guided Axillary Block Does Not Invariably Result in Neurologic Injury.”1 My comments to the individual physicians are listed below.


  • Open Access

    Nerve Puncture and Apparent Intraneural Injection during Ultrasound-guided Axillary Block Does Not Invariably Result in Neurologic Injury

    by Paul E. Bigeleisen

    Background: Nerve puncture by the block needle and intraneural injection of local anesthetic are thought to be major risk factors leading to neurologic injury after peripheral nerve blocks. In this study, the author sought to determine the needle-nerve relation and location of the injectate during ultrasound-guided axillary plexus block. Methods: Using ultrasound-guided axillary plexus block (10-MHz linear transducer, SonoSite, Bothel, WA; 22-gauge B-bevel needle, Becton Dickinson, Franklin Parks, NJ), the incidence of apparent nerve puncture and intraneural injection of local anesthetic was prospectively studied in 26 patients. To determine the onset, success rate, and any residual neurologic deficit, qualitative sensory and quantitative motor testing were performed before and 5 and 20 min after block placement. At a follow-up 6 months after the blocks, the patients were examined for any neurologic deficit. Results: Twenty-two of 26 patients had nerve puncture of at least one nerve, and 21 of 26 patients had intraneural injection of at least one nerve. In the entire cohort, 72 of a total of 104 nerves had intraneural injection. Sensory and motor testing before and 6 months after the nerve injections were unchanged. Conclusions: Under the conditions of this study, puncturing of the peripheral nerves and apparent intraneural injection during axillary plexus block did not lead to a neurologic injury.