Tyge Nordentoft
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tyge Nordentoft has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hans-Christian Pommergaard
Hepatic Malignancy Surgical Research Unit (HEPSURU), Department of Digestive Diseases, Transplantation and General Surgery Copenhagen University Hospital—Rigshospitalet Copenhagen Denmark
1 shared publication Jacob Rosenberg
1 shared publicationJohn Rømer
1 shared publication- Michael Patrick Achiam
Department of Digestive Diseases, Transplantation and General Surgery, Centre for Cancer and Organ Diseases, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark
1 shared publication Michael Sørensen
1 shared publication- Michael Sørensen
Department of Hepatology & Gastroenterology, Aarhus University Hospital, Aarhus N, Denmark
1 shared publication
Latest Publications
- 1 May 2015
- Vol. 62 (5)
Sealing of gastrointestinal anastomoses with fibrin glue coated collagen patch
Colorectal cancer (CRC) is the most common cancer of the gastrointestinal tract. In Denmark is CRC the 3. most frequent form of cancer and the 3. leading cause of cancer-related death. Anastomoses: Surgical resection is the only curative treatment of CRC and in Denmark about 85% of patients with CRC are therefore operated. An anastomosis will be established in most cases. Colorectal anastomoses are established in the treatment of benign diseases too, i.e. as part of the surgical treatment of inflammatory bowel disease and in acute surgery. Furthermore anastomoses are conducted in other parts of the gastrointestinal tract i.e. esophagus, stomach, small bowel and bile system. Anastomotic leakage (AL): AL is the most serious complication of gastrointestinal surgery with a 30-day mortality of 13-27%. The reported AL rate ranges from 1 to 39%. In addition to immediate clinical consequences AL is an independent predictor of reduced general and cancer-specific survival. Leakage can manifest as generalized peritonitis, requiring acute resurgery or as a more localized accumulation/abscess or as a subclinical leakage. Sealing of anastomoses: Numerous studies on anastomotic sealing have been conducted with the aim of reducing the number of AL's. The results of these are conflicting and predominantly disappointing. The drug Tacho-Sil (TS) consists of a collagen patch, which on the one side is coated with fibrin glue (FG), which gives it an adhesive property. TS is registered for use in surgical hemostasis. Animal models: Spontaneous AL in animals is infrequent. It is therefore necessary to use a model of AL. No such model exists and must be developed. To clarify if the sealing of anastomoses with TS is feasible and safe in an experimental design. To develop a standardized model of AL in pigs. To clarify if sealing of colon-anastomoses with TS can reduce the number of clinical ALs in an experimental design. To clarify whether there is evidence that FG influences healing of gastrointestinal anastomosis. Safety study, that examines whether it is safe to seal anastomoses with a TS. Experimental study on pigs. Two anastomoses on each pig, one sealed with TS. After 1-6 weeks of observation the anastomosis were examined for AL, stenoses, strength and compared microscopic. No difference between sealed and unsealed anastomosis. This study is completed and published. Model study, to develop model of AL on pigs. A total of 22 pigs had an anastomosis of colon. All anastomoses were left with a standardized defect on 5-21 mm. The pigs were observed in order to assess how big the defect should be before the pigs developed visible leakage and/or fecal peritonitis. Model developed. 21 mm defect significant. This study is completed and published. Efficacy study, testing if TachoSil can seal an AL and thus prevent that this becomes clinically significant. A total of 20 pigs had a colon-anastomoses with a standardized defect of 21 mm. The pigs were randomized to sealing with TS or no sealing. Re-laparotomy after 7 days examining for visible leakage and/or fecal peritonitis. TachoSil® able to seal the defect (p=0.0055). This study is completed and published. Systematic review, with the purpose to study whether there is evidence that FG influence the healing of gastrointestinal anastomosis. Conflicting. FG does not seem to have an effect. This study completed and published. Sealing of GI-anastomosis with TachoSil is safe and feasible. A defect of at least 21mm must be left in colon anastomosis to induce clinical peritonitis. Sealing of defect colon-anastomosis in pigs with TachoSil can prevent clinical leakage and peritonitis. FG has no positive effect on microscopically healing of GI-anastomosis.
- 1 May 2015
- Vol. 62 (5)
Sealing of gastrointestinal anastomoses with fibrin glue coated collagen patch
Colorectal cancer (CRC) is the most common cancer of the gastrointestinal tract. In Denmark is CRC the 3. most frequent form of cancer and the 3. leading cause of cancer-related death. Anastomoses: Surgical resection is the only curative treatment of CRC and in Denmark about 85% of patients with CRC are therefore operated. An anastomosis will be established in most cases. Colorectal anastomoses are established in the treatment of benign diseases too, i.e. as part of the surgical treatment of inflammatory bowel disease and in acute surgery. Furthermore anastomoses are conducted in other parts of the gastrointestinal tract i.e. esophagus, stomach, small bowel and bile system. Anastomotic leakage (AL): AL is the most serious complication of gastrointestinal surgery with a 30-day mortality of 13-27%. The reported AL rate ranges from 1 to 39%. In addition to immediate clinical consequences AL is an independent predictor of reduced general and cancer-specific survival. Leakage can manifest as generalized peritonitis, requiring acute resurgery or as a more localized accumulation/abscess or as a subclinical leakage. Sealing of anastomoses: Numerous studies on anastomotic sealing have been conducted with the aim of reducing the number of AL's. The results of these are conflicting and predominantly disappointing. The drug Tacho-Sil (TS) consists of a collagen patch, which on the one side is coated with fibrin glue (FG), which gives it an adhesive property. TS is registered for use in surgical hemostasis. Animal models: Spontaneous AL in animals is infrequent. It is therefore necessary to use a model of AL. No such model exists and must be developed. To clarify if the sealing of anastomoses with TS is feasible and safe in an experimental design. To develop a standardized model of AL in pigs. To clarify if sealing of colon-anastomoses with TS can reduce the number of clinical ALs in an experimental design. To clarify whether there is evidence that FG influences healing of gastrointestinal anastomosis. Safety study, that examines whether it is safe to seal anastomoses with a TS. Experimental study on pigs. Two anastomoses on each pig, one sealed with TS. After 1-6 weeks of observation the anastomosis were examined for AL, stenoses, strength and compared microscopic. No difference between sealed and unsealed anastomosis. This study is completed and published. Model study, to develop model of AL on pigs. A total of 22 pigs had an anastomosis of colon. All anastomoses were left with a standardized defect on 5-21 mm. The pigs were observed in order to assess how big the defect should be before the pigs developed visible leakage and/or fecal peritonitis. Model developed. 21 mm defect significant. This study is completed and published. Efficacy study, testing if TachoSil can seal an AL and thus prevent that this becomes clinically significant. A total of 20 pigs had a colon-anastomoses with a standardized defect of 21 mm. The pigs were randomized to sealing with TS or no sealing. Re-laparotomy after 7 days examining for visible leakage and/or fecal peritonitis. TachoSil® able to seal the defect (p=0.0055). This study is completed and published. Systematic review, with the purpose to study whether there is evidence that FG influence the healing of gastrointestinal anastomosis. Conflicting. FG does not seem to have an effect. This study completed and published. Sealing of GI-anastomosis with TachoSil is safe and feasible. A defect of at least 21mm must be left in colon anastomosis to induce clinical peritonitis. Sealing of defect colon-anastomosis in pigs with TachoSil can prevent clinical leakage and peritonitis. FG has no positive effect on microscopically healing of GI-anastomosis.
- Open Access
- 18 September 2014
- Published by S. Karger AG in European Surgical Research
- Vol. 54 (1-2) , 1-13
Fibrin Glue Does Not Improve Healing of Gastrointestinal Anastomoses: A Systematic Review
Background/Aim: Anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. In order to reduce its incidence, several clinical and experimental studies on anastomotic sealing have been performed. In a number of these studies, the sealing material has been fibrin glue (FG), and the results in individual studies have been varying. The positive effect of anastomotic sealing with FG might be due to the mechanical/physical properties, the increased healing of the anastomoses or both. The aim of this systematic review was to evaluate the existing evidence on the healing effects of FG on gastrointestinal anastomoses. Methods: PubMed, EMBASE and the Cochrane databases were searched for studies evaluating the healing process of gastrointestinal anastomoses after any kind of FG application. The search period was from 1953 to December 2013. Results: Twenty-eight studies were included in the qualitative synthesis. These studies were all experimental studies, since no human studies used histological or biochemical evaluation of healing. In 7 of the 28 studies, a positive effect of FG on healing was found, while 8 studies reported a negative effect and 11 studies found no effect. Furthermore, 2 studies reported unclear results. The difference in the study outcome was independent of the study design and the type of FG used. Conclusion: In the available studies, FG did not consistently have a positive influence on the healing of gastrointestinal anastomoses. It is consequently plausible that the positive effect of FG sealing of gastrointestinal anastomoses, if there is any, may be due to a mechanical sealing effect rather than due to improved healing per se.
- 18 September 2014
- Published by S. Karger AG in European Surgical Research
- Vol. 54 (1-2) , 1-13
Open AccessFibrin Glue Does Not Improve Healing of Gastrointestinal Anastomoses: A Systematic Review
Background/Aim: Anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. In order to reduce its incidence, several clinical and experimental studies on anastomotic sealing have been performed. In a number of these studies, the sealing material has been fibrin glue (FG), and the results in individual studies have been varying. The positive effect of anastomotic sealing with FG might be due to the mechanical/physical properties, the increased healing of the anastomoses or both. The aim of this systematic review was to evaluate the existing evidence on the healing effects of FG on gastrointestinal anastomoses. Methods: PubMed, EMBASE and the Cochrane databases were searched for studies evaluating the healing process of gastrointestinal anastomoses after any kind of FG application. The search period was from 1953 to December 2013. Results: Twenty-eight studies were included in the qualitative synthesis. These studies were all experimental studies, since no human studies used histological or biochemical evaluation of healing. In 7 of the 28 studies, a positive effect of FG on healing was found, while 8 studies reported a negative effect and 11 studies found no effect. Furthermore, 2 studies reported unclear results. The difference in the study outcome was independent of the study design and the type of FG used. Conclusion: In the available studies, FG did not consistently have a positive influence on the healing of gastrointestinal anastomoses. It is consequently plausible that the positive effect of FG sealing of gastrointestinal anastomoses, if there is any, may be due to a mechanical sealing effect rather than due to improved healing per se.
- 1 January 2007
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 20 (6) , 363-369
Sealing of Gastrointestinal Anastomoses with a Fibrin Glue-Coated Collagen Patch: A Safety Study
Sealing of anastomoses has previously been tested with several methods, including sealing with liquid fibrin glue. Sealing with a collagen patch coated with fibrin glue components has never been systematically examined. The aim of the present study was to determine the safety of sealing gastrointestinal anastomoses with a collagen patch coated with fibrin glue. The study is a prospective, experimental animal study comparing sealed and unsealed gastrointestinal anastomoses. Laparotomy was performed in 11 pigs under general anesthesia. In each pig two anastomoses were performed on the small intestine. One of the anastomoses was sealed with a collagen patch coated with fibrin glue components (TachoSil). The other anastomosis contained no sealing. The pigs were observed for 1 to 6 weeks. The observation period was followed by in vivo examination under general anesthesia and included observation for anastomotic leakage, signs of present or former peritonitis, abscess, adhesions to the anastomoses, and signs of intestinal obstruction. In addition, the anastomotic diameter was measured with barium and radiography. Finally, bursting pressure was measured in each segment. After the pigs were sacrificed, the bowel segments were microscopically examined. There were no differences between the sealed and the unsealed anastomoses with respect to abdominal pathology, in vivo bursting pressure, or degree of stenosis. The collagen fleeces were in situ in all anastomoses. Microscopically, we found no difference in healing or signs of infection.
- 1 January 2007
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 20 (6) , 363-369
Sealing of Gastrointestinal Anastomoses with a Fibrin Glue-Coated Collagen Patch: A Safety Study
Sealing of anastomoses has previously been tested with several methods, including sealing with liquid fibrin glue. Sealing with a collagen patch coated with fibrin glue components has never been systematically examined. The aim of the present study was to determine the safety of sealing gastrointestinal anastomoses with a collagen patch coated with fibrin glue. The study is a prospective, experimental animal study comparing sealed and unsealed gastrointestinal anastomoses. Laparotomy was performed in 11 pigs under general anesthesia. In each pig two anastomoses were performed on the small intestine. One of the anastomoses was sealed with a collagen patch coated with fibrin glue components (TachoSil). The other anastomosis contained no sealing. The pigs were observed for 1 to 6 weeks. The observation period was followed by in vivo examination under general anesthesia and included observation for anastomotic leakage, signs of present or former peritonitis, abscess, adhesions to the anastomoses, and signs of intestinal obstruction. In addition, the anastomotic diameter was measured with barium and radiography. Finally, bursting pressure was measured in each segment. After the pigs were sacrificed, the bowel segments were microscopically examined. There were no differences between the sealed and the unsealed anastomoses with respect to abdominal pathology, in vivo bursting pressure, or degree of stenosis. The collagen fleeces were in situ in all anastomoses. Microscopically, we found no difference in healing or signs of infection.
- 10 November 2006
- Published by S. Karger AG in European Surgical Research
- Vol. 39 (1) , 14-16
Leakage of Colon Anastomoses: Development of an Experimental Model in Pigs
Background: In order to investigate anastomotic leakage, a number of experimental animal studies have been previously carried out. Due to the low frequency of spontaneous anastomotic leakages, there have been studies on gastrointestinal anastomoses with iatrogenically produced leakages. A leakage model has only been developed in one gastric bypass study. The aim of the present study was to develop a leakage model of pig colon anastomoses. This type of study has never been performed before. Materials and Methods: Anastomosis was performed in 22 pigs. In all anastomoses a standardized rupture in the anastomotic line was made. The rupture ranged from 5 mm in the first group of pigs, increasing subsequently to 21 mm in the last group. Autopsy was performed after 7 days. The end points were macroscopic leakage and fecal peritonitis. Results: 6 out of the 6 pigs with a 21-mm rupture developed leakage and fecal peritonitis. In the groups with smaller ruptures, most of the pigs did not develop any signs of leakage or fecal peritonitis. The difference is significant. The group of pigs with peritonitis had significantly fewer adhesions to the anastomoses than the group without peritonitis. Conclusion: A model of anastomotic leakage on pig colon is developed with creation of a 21-mm rupture in the anastomotic line.
- 10 November 2006
- Published by S. Karger AG in European Surgical Research
- Vol. 39 (1) , 14-16
Leakage of Colon Anastomoses: Development of an Experimental Model in Pigs
Background: In order to investigate anastomotic leakage, a number of experimental animal studies have been previously carried out. Due to the low frequency of spontaneous anastomotic leakages, there have been studies on gastrointestinal anastomoses with iatrogenically produced leakages. A leakage model has only been developed in one gastric bypass study. The aim of the present study was to develop a leakage model of pig colon anastomoses. This type of study has never been performed before. Materials and Methods: Anastomosis was performed in 22 pigs. In all anastomoses a standardized rupture in the anastomotic line was made. The rupture ranged from 5 mm in the first group of pigs, increasing subsequently to 21 mm in the last group. Autopsy was performed after 7 days. The end points were macroscopic leakage and fecal peritonitis. Results: 6 out of the 6 pigs with a 21-mm rupture developed leakage and fecal peritonitis. In the groups with smaller ruptures, most of the pigs did not develop any signs of leakage or fecal peritonitis. The difference is significant. The group of pigs with peritonitis had significantly fewer adhesions to the anastomoses than the group without peritonitis. Conclusion: A model of anastomotic leakage on pig colon is developed with creation of a 21-mm rupture in the anastomotic line.