Lufan Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lufan Zou has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Liang Chen
University of Ottawa
5 shared publications- Xiaoyi Bao
University of Ottawa
4 shared publications Fabien Ravet
University of Ottawa
2 shared publications- Fabien Ravet
Univ. of Ottawa (Canada)
2 shared publications Xiaoyi Bao
University of Ottawa
2 shared publications- Fabien Ravet
Fiber Optics Group, University of Ottawa, Ottawa, ON K1N 6N5, Canada
1 shared publication
Latest Publications
- 25 August 2006
- Published by Optica Publishing Group in Optics Letters
- Vol. 31 (18) , 2698-2700
Effect of Brillouin slow light on distributed Brillouin fiber sensors
The effect of Brillouin slow light on distributed Brillouin fiber sensors (DBFSs) is studied. We demonstrate Brillouin slow light for a pulse with peak powers from 3.3 to on depletion of the pump power ranging from 1.3 to in conventional optical fibers (SMF-28). Experiments show that, when pump power depletion is not negligible, for a given the Brillouin gain and delay time of a pulse decrease when increases in a long sensing fiber. The optimum pump beam depletion resulting from strong interaction of the pump and the probe in the fiber provides accurate temperature and strain information at a high spatial resolution. Our study reveals that at low the spatial resolution error caused by the pulse delay for a DBFS with centimeter spatial resolution is less than 5% of the pulse length.- 25 August 2006
- Published by Optica Publishing Group in Optics Letters
- Vol. 31 (18) , 2698-2700
Effect of Brillouin slow light on distributed Brillouin fiber sensors
The effect of Brillouin slow light on distributed Brillouin fiber sensors (DBFSs) is studied. We demonstrate Brillouin slow light for a pulse with peak powers from 3.3 to on depletion of the pump power ranging from 1.3 to in conventional optical fibers (SMF-28). Experiments show that, when pump power depletion is not negligible, for a given the Brillouin gain and delay time of a pulse decrease when increases in a long sensing fiber. The optimum pump beam depletion resulting from strong interaction of the pump and the probe in the fiber provides accurate temperature and strain information at a high spatial resolution. Our study reveals that at low the spatial resolution error caused by the pulse delay for a DBFS with centimeter spatial resolution is less than 5% of the pulse length.- 10 May 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (14) , 3372-3377
Distributed Brillouin fiber sensor for detecting pipeline buckling in an energy pipe under internal pressure
A distributed Brillouin fiber sensor has been employed to detect localized pipe-wall buckling in an energy pipe by measuring the longitudinal and hoop strain distributions along the outer surface of the pipe for the first time. The locations of the localized pipe-wall buckling are found and distinguished using their corresponding strain–load data. The formation of the buckling process for the compression and tension characters is studied in the longitudinal and hoop directions. For the pipe with internal pressure, concentric load, and bending load, a localized pipe-wall buckling takes place away from the middle of the pipe on the compressive side and a strain peak with an overall buckling occurs on the tensile side according to the longitudinal strain distributions along the pipe. Different strains on two neutral lines are also observed in the hoop strain distribution, which should be caused by the pipe weld joint.
- 10 May 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (14) , 3372-3377
Distributed Brillouin fiber sensor for detecting pipeline buckling in an energy pipe under internal pressure
A distributed Brillouin fiber sensor has been employed to detect localized pipe-wall buckling in an energy pipe by measuring the longitudinal and hoop strain distributions along the outer surface of the pipe for the first time. The locations of the localized pipe-wall buckling are found and distinguished using their corresponding strain–load data. The formation of the buckling process for the compression and tension characters is studied in the longitudinal and hoop directions. For the pipe with internal pressure, concentric load, and bending load, a localized pipe-wall buckling takes place away from the middle of the pipe on the compressive side and a strain peak with an overall buckling occurs on the tensile side according to the longitudinal strain distributions along the pipe. Different strains on two neutral lines are also observed in the hoop strain distribution, which should be caused by the pipe weld joint.
- 1 January 2006
- Published by Optica Publishing Group in Optics Express
- Vol. 14 (22) , 10351-10358
Theoretical study of the effect of slow light on BOTDA spatial resolution
Due to the resonant nature of Brillouin scattering, delay occurs while pulse is propagating in an optical fiber. This effect influences the location accuracy of distributed Brillouin sensors. The maximum delay in sensing fibers depends on length, position, pump and Stokes powers. Considering pump depletion, we have obtained integral solutions for the coupled amplitude equations under steady state conditions and then calculated the group delay. The results show that moderate pump depletion (which is the optimized sensor working range) mitigates significantly the delay, and the maximum delay induced at resonance is only a fraction of Brillouin Optical Time Domain (BOTDA) spatial resolution, which means that the use of pulse width to define the spatial resolution is valid when Brillouin slow light is considered. We have shown that uniform strain and temperature distribution in a fiber gives the maximum delay induced uncertainty.
- 1 January 2006
- Published by Optica Publishing Group in Optics Express
- Vol. 14 (22) , 10351-10358
Theoretical study of the effect of slow light on BOTDA spatial resolution
Due to the resonant nature of Brillouin scattering, delay occurs while pulse is propagating in an optical fiber. This effect influences the location accuracy of distributed Brillouin sensors. The maximum delay in sensing fibers depends on length, position, pump and Stokes powers. Considering pump depletion, we have obtained integral solutions for the coupled amplitude equations under steady state conditions and then calculated the group delay. The results show that moderate pump depletion (which is the optimized sensor working range) mitigates significantly the delay, and the maximum delay induced at resonance is only a fraction of Brillouin Optical Time Domain (BOTDA) spatial resolution, which means that the use of pulse width to define the spatial resolution is valid when Brillouin slow light is considered. We have shown that uniform strain and temperature distribution in a fiber gives the maximum delay induced uncertainty.
- 23 May 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5855, 571-575
Distributed fiber strain sensor based on Brillouin scattering for inspection of pipeline buckling
A distributed strain sensor based on Brillouin scattering has been employed to inspect localized pipe-wall buckling on a length of 2.58 m and diameter of 0.75 m steel pipe by measuring the axial strain distributions along the outer surface of the pipe. An optical fiber with 10 sections was laid along the longitudinal direction of the pipe. Both compressive load and bending load were applied on both end of tested pipe up to 2,013 and 300 kIPS respectively, to induce the localized pipe-wall buckling. The buckling locations comprising tension and compression of the pipe wall are found and distinguished using their corresponding strain distribution data. The compressive strains of - 4330 and - 6856 με measured by our distributed strain sensor on the bending load of 220 and 300 kIPS, respectively, at one location near buckling point, match the readings from strain gauge at the same location where the strain gauge attached. The tensile strain happened at different sides of the pipe are found too.
- 23 May 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5855, 571-575
Distributed fiber strain sensor based on Brillouin scattering for inspection of pipeline buckling
A distributed strain sensor based on Brillouin scattering has been employed to inspect localized pipe-wall buckling on a length of 2.58 m and diameter of 0.75 m steel pipe by measuring the axial strain distributions along the outer surface of the pipe. An optical fiber with 10 sections was laid along the longitudinal direction of the pipe. Both compressive load and bending load were applied on both end of tested pipe up to 2,013 and 300 kIPS respectively, to induce the localized pipe-wall buckling. The buckling locations comprising tension and compression of the pipe wall are found and distinguished using their corresponding strain distribution data. The compressive strains of - 4330 and - 6856 με measured by our distributed strain sensor on the bending load of 220 and 300 kIPS, respectively, at one location near buckling point, match the readings from strain gauge at the same location where the strain gauge attached. The tensile strain happened at different sides of the pipe are found too.
- 1 April 2005
- Published by Optica Publishing Group in Optics Letters
- Vol. 30 (7) , 705-707
Brillouin spectral deconvolution method for centimeter spatial resolution and high-accuracy strain measurement in Brillouin sensors
This paper was published in Optics Letters and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/cfm?URI=ol-30-7-705. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.Shahraam Afshar V., Xiaoyi Bao, Lufan Zou, and Liang Che
- 1 April 2005
- Published by Optica Publishing Group in Optics Letters
- Vol. 30 (7) , 705-707
Brillouin spectral deconvolution method for centimeter spatial resolution and high-accuracy strain measurement in Brillouin sensors
This paper was published in Optics Letters and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/cfm?URI=ol-30-7-705. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.Shahraam Afshar V., Xiaoyi Bao, Lufan Zou, and Liang Che
- 29 July 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5391, 293-301
Highly precise distributed Brillouin scattering sensor for structural health monitoring of optical ground wire cable
A distributed Brillouin scattering sensor with high special precision has been developed for the measurement of small damages/cracks of 1.5 cm. The out-layer damaged regions in an optical ground wire (OPGW) cable have been identified successfully by measuring the strain distributions every 5 cm using this technology. The stress increased to 127 kN which corresponds to more than 7500 micro-strain in the fibers. The locations of structural indentations comprising repaired and undamaged regions are found and distinguished using their corresponding strain data. The elongation of repaired region increases with time on 127 kN. These results are quantified in terms of the fiber orientation, stress, and behavior relative to undamaged sections.
- 29 July 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5391, 293-301
Highly precise distributed Brillouin scattering sensor for structural health monitoring of optical ground wire cable
A distributed Brillouin scattering sensor with high special precision has been developed for the measurement of small damages/cracks of 1.5 cm. The out-layer damaged regions in an optical ground wire (OPGW) cable have been identified successfully by measuring the strain distributions every 5 cm using this technology. The stress increased to 127 kN which corresponds to more than 7500 micro-strain in the fibers. The locations of structural indentations comprising repaired and undamaged regions are found and distinguished using their corresponding strain data. The elongation of repaired region increases with time on 127 kN. These results are quantified in terms of the fiber orientation, stress, and behavior relative to undamaged sections.