Maria-Benedicta Edwards
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria-Benedicta Edwards has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Kenneth M Taylor
3 shared publications- Jeffrey W. Hand
Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, U.K.
2 shared publications Kenneth M. Taylor
United Kingdom Heart Valve Registry, Department of Cardiothoracic Surgery, Hammersmith Hospital, London, United Kingdom
2 shared publications- Roger J. Ordidge
Melbourne Brain Centre Imaging Unit University of Melbourne Australia
2 shared publications - David L. Thomas
Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology University College London London UK
1 shared publication Ian R. Young
Department of Electronic and Electrical Engineering, Imperial College, London, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 18 July 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 22 (2) , 311-317
Assessment of magnetic field (4.7 T) induced forces on prosthetic heart valves and annuloplasty rings
Purpose: To assess the magnetic field interactions on 11 heart valve prostheses and 12 annuloplasty rings subjected to a 4.7 T MR system.Materials and Methods: Ex vivo testing was performed to evaluate translational and rotational forces using previously described techniques.Results: Seventeen out of 23 prostheses showed zero interaction with the magnetic field. Translational forces with deflection angles of 2–20° were demonstrated in six prostheses. Only two heart valves and two annuloplasty rings demonstrated rotational forces. The Carpentier Edwards (CE) Physio Ring, which contains Elgiloy, demonstrated deflection angles three times greater than those previously measured at 1.5 T. Furthermore, there was a direct relationship between increasing prosthesis size and increasing translational force. All heart valve prostheses attracted to the magnetic field were slightly paramagnetic/weakly ferromagnetic.Conclusion: Twenty‐three heart valve prostheses evaluated for MRI are considered safe in static fields up to 4.7 T based on current safety criteria. However, the CE Physio Ring appeared to develop an increasing magnetism upon re‐entry into the MR system. We conclude that prostheses made from Elgiloy may not be acceptable for patients in an MR environment of ≥4.7 T. Further investigations are required to confirm the safety of Elgiloy. J. Magn. Reson. Imaging 2005;22:311–317.
- 18 July 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 22 (2) , 311-317
Open AccessAssessment of magnetic field (4.7 T) induced forces on prosthetic heart valves and annuloplasty rings
Purpose: To assess the magnetic field interactions on 11 heart valve prostheses and 12 annuloplasty rings subjected to a 4.7 T MR system.Materials and Methods: Ex vivo testing was performed to evaluate translational and rotational forces using previously described techniques.Results: Seventeen out of 23 prostheses showed zero interaction with the magnetic field. Translational forces with deflection angles of 2–20° were demonstrated in six prostheses. Only two heart valves and two annuloplasty rings demonstrated rotational forces. The Carpentier Edwards (CE) Physio Ring, which contains Elgiloy, demonstrated deflection angles three times greater than those previously measured at 1.5 T. Furthermore, there was a direct relationship between increasing prosthesis size and increasing translational force. All heart valve prostheses attracted to the magnetic field were slightly paramagnetic/weakly ferromagnetic.Conclusion: Twenty‐three heart valve prostheses evaluated for MRI are considered safe in static fields up to 4.7 T based on current safety criteria. However, the CE Physio Ring appeared to develop an increasing magnetism upon re‐entry into the MR system. We conclude that prostheses made from Elgiloy may not be acceptable for patients in an MR environment of ≥4.7 T. Further investigations are required to confirm the safety of Elgiloy. J. Magn. Reson. Imaging 2005;22:311–317.
- 31 August 2004
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 78 (2) , 755
Reply
- 1 August 2003
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 76 (2) , 482-485
Is 30-day mortality an adequate outcome statistic for patients considering heart valve replacement?
- 1 August 2003
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 76 (2) , 482-485
Is 30-day mortality an adequate outcome statistic for patients considering heart valve replacement?
- 1 March 2003
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 75 (3) , 830-834
Outcomes in nonagenarians after heart valve replacement operation
- 1 March 2003
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 75 (3) , 830-834
Outcomes in nonagenarians after heart valve replacement operation
- 25 November 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 16 (6) , 653-659
Translational and rotational forces on heart valve prostheses subjected ex vivo to a 4.7‐T MR system
Purpose: To assess the magnetic field interactions on 60 heart valve prostheses subjected to a 4.7 T MR system. It addresses the question of whether heart valves deemed safe at 1.5 T may pose safety hazards as patients are exposed to increased static magnetic fields.Materials and Methods: Ex vivo testing was performed to evaluate translational and rotational forces on 60 heart valves using previously described techniques.Results: Translational forces were detected on 58 heart valves ranging from 0.5° to 7.5°. Seven valves exhibited paramagnetic/weakly ferromagnetic behavior, and 51 valves exhibited diamagnetic behavior. Rotational forces were observed for 46 valves.Conclusions: Criteria previously used for safety assessment of heart valve prostheses and expressed in terms of magnetic forces suggest the forces observed in this study are compatible with the safe use of these valves in magnetic resonance (MR) systems with static fields up to 4.7 T. J. Magn. Reson. Imaging 2002;16:653–659.
- 25 November 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 16 (6) , 653-659
Translational and rotational forces on heart valve prostheses subjected ex vivo to a 4.7‐T MR system
Purpose: To assess the magnetic field interactions on 60 heart valve prostheses subjected to a 4.7 T MR system. It addresses the question of whether heart valves deemed safe at 1.5 T may pose safety hazards as patients are exposed to increased static magnetic fields.Materials and Methods: Ex vivo testing was performed to evaluate translational and rotational forces on 60 heart valves using previously described techniques.Results: Translational forces were detected on 58 heart valves ranging from 0.5° to 7.5°. Seven valves exhibited paramagnetic/weakly ferromagnetic behavior, and 51 valves exhibited diamagnetic behavior. Rotational forces were observed for 46 valves.Conclusions: Criteria previously used for safety assessment of heart valve prostheses and expressed in terms of magnetic forces suggest the forces observed in this study are compatible with the safe use of these valves in magnetic resonance (MR) systems with static fields up to 4.7 T. J. Magn. Reson. Imaging 2002;16:653–659.