Gian Carlo Montanari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gian Carlo Montanari has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Giovanni Mazzanti
Department of Electrical, Electronic and Information Engineering, University of Bologna, Bologna, Italy
9 shared publications - A. Cavallini
DIE-LIMAT, University of Bologna
3 shared publications A. Motori
2 shared publicationsL. Simoni
Istituto di Elettrotecnica Ind., Bologna Univ., Italy
2 shared publicationsM. Cacciari
2 shared publicationsP. Anelli
2 shared publications
Latest Publications
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Partial Discharge Analysis and Asset Management: Experiences on Monitoring of Power Apparatus
This paper presents a new technique to perform partial discharge (PD) monitoring on high voltage apparatus that are critical to transmission systems, focusing on high voltage cable systems. The hardware used for PD monitoring is innovative since it can provide information concerning PD pulse waveforms, allowing, in particular, disturbance and noise rejection. The PD system is also endowed with an identification tool that, at a first level, is able to discriminate between internal, surface and corona PD. This identification tool can be used to improve monitoring effectiveness, since the warning system can be trained, as an example, to weight alarm severity against PD identification, providing more emphasis to internal activities
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Partial Discharge Analysis and Asset Management: Experiences on Monitoring of Power Apparatus
This paper presents a new technique to perform partial discharge (PD) monitoring on high voltage apparatus that are critical to transmission systems, focusing on high voltage cable systems. The hardware used for PD monitoring is innovative since it can provide information concerning PD pulse waveforms, allowing, in particular, disturbance and noise rejection. The PD system is also endowed with an identification tool that, at a first level, is able to discriminate between internal, surface and corona PD. This identification tool can be used to improve monitoring effectiveness, since the warning system can be trained, as an example, to weight alarm severity against PD identification, providing more emphasis to internal activities
- 25 June 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 703-706
Searching for PD-based indexes able to infer the location of internal defects in insulation
The aim of this paper is to derive PD-based indexes and criteria that are able to indicate whether an internal defect, a cavity, is located close to the HV electrode, to the ground electrode, or in the bulk of the insulation. For this purpose, several measurement sessions were carried out on laboratory samples whose geometry was suitably designed (CIGRE type I and type II cell). In addition, measurements were performed on a capacitive insulator, having known location defects. The measurements results and their evaluation are described in the paper. It is shown that indexes useful for PD source location can be extracted from PD phase distributions. Author(s) Cavallini, A. DIE, Bologna Univ., Italy Conti, M. ; Montanari, G.C. ; Contin, A. ; Candela, R. ; Romano, P. ; Schifani, R.
- 25 June 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 703-706
Searching for PD-based indexes able to infer the location of internal defects in insulation
The aim of this paper is to derive PD-based indexes and criteria that are able to indicate whether an internal defect, a cavity, is located close to the HV electrode, to the ground electrode, or in the bulk of the insulation. For this purpose, several measurement sessions were carried out on laboratory samples whose geometry was suitably designed (CIGRE type I and type II cell). In addition, measurements were performed on a capacitive insulator, having known location defects. The measurements results and their evaluation are described in the paper. It is shown that indexes useful for PD source location can be extracted from PD phase distributions. Author(s) Cavallini, A. DIE, Bologna Univ., Italy Conti, M. ; Montanari, G.C. ; Contin, A. ; Candela, R. ; Romano, P. ; Schifani, R.
- 20 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 559-563 vol.2
Investigation of DC threshold of polyethylenes as a tool for insulation characterization
Dc space-charge measurements, performed by PEA, are used to estimate the electrical threshold in XLPE and modified XLPE-based materials. In addition to threshold, a quantity is proposed for the characterization of a material, in relation to its expected voltage endurance. This quantity is associated to the slope of the charge vs field plot coming from space-charge measurements. The different behavior as regards space-charge accumulation in the tested materials and its relevance to insulation endurance is discussed. The quantities presented in this paper are useful for the electrical characterization of insulating materials candidates for DC high-field applications.
- 20 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 559-563 vol.2
Investigation of DC threshold of polyethylenes as a tool for insulation characterization
Dc space-charge measurements, performed by PEA, are used to estimate the electrical threshold in XLPE and modified XLPE-based materials. In addition to threshold, a quantity is proposed for the characterization of a material, in relation to its expected voltage endurance. This quantity is associated to the slope of the charge vs field plot coming from space-charge measurements. The different behavior as regards space-charge accumulation in the tested materials and its relevance to insulation endurance is discussed. The quantities presented in this paper are useful for the electrical characterization of insulating materials candidates for DC high-field applications.
- 2 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Considerations on the compatibility conditions of the Eyring model applied for multiple stresses
The thermodynamic approach is often used for the life modeling of insulating materials subjected to multiple thermal-electrical stresses. It is pointed out, however, that even if the thermodynamic approach seems quite promising for insulation characterization, care should be taken when it is used to infer material behavior under multiple thermal and electrical stresses. Indeed, at very low electrical stresses or temperatures, life is determined by thermal and electrical aging, respectively, and therefore compatibility conditions should be satisfied. The authors show that compatibility considerations are useful in formulating mathematically correct models of insulation life under multiple stresses.
- 2 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Considerations on the compatibility conditions of the Eyring model applied for multiple stresses
The thermodynamic approach is often used for the life modeling of insulating materials subjected to multiple thermal-electrical stresses. It is pointed out, however, that even if the thermodynamic approach seems quite promising for insulation characterization, care should be taken when it is used to infer material behavior under multiple thermal and electrical stresses. Indeed, at very low electrical stresses or temperatures, life is determined by thermal and electrical aging, respectively, and therefore compatibility conditions should be satisfied. The authors show that compatibility considerations are useful in formulating mathematically correct models of insulation life under multiple stresses.
- 21 November 2002
- Published by Wiley in Polymer International
- Vol. 51 (11) , 1151-1158
Ageing of polymeric insulating materials and insulation system design
This paper presents an overview of the problem of modelling the ageing of polymeric insulating materials used for electrical applications; a relation between ageing and life models; the different approaches brought to phenomenological or chemical–physical life models; the need to search for diagnostic properties and to investigate the prevailing degradation mechanisms as a function of applied stresses and material morphology; and the way design stresses are chosen and reliability evaluations of insulation systems are carried out.© 2002 Society of Chemical Industry
- 21 November 2002
- Published by Wiley in Polymer International
- Vol. 51 (11) , 1151-1158
Ageing of polymeric insulating materials and insulation system design
This paper presents an overview of the problem of modelling the ageing of polymeric insulating materials used for electrical applications; a relation between ageing and life models; the different approaches brought to phenomenological or chemical–physical life models; the need to search for diagnostic properties and to investigate the prevailing degradation mechanisms as a function of applied stresses and material morphology; and the way design stresses are chosen and reliability evaluations of insulation systems are carried out.© 2002 Society of Chemical Industry
- 19 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 274-277
Combined electro-thermo-mechanical model for life prediction of electrical insulating materials
A multistress model, appropriate for life prediction of electrical insulating materials subjected to electrical, thermal and mechanical stresses, is presented and compared with experimental life-test data relevant to HV generator stator insulation. The algorithm for the estimation of the large number of model parameters is presented and the goodness-of-fit of the model discussed.
- 19 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 274-277
Combined electro-thermo-mechanical model for life prediction of electrical insulating materials
A multistress model, appropriate for life prediction of electrical insulating materials subjected to electrical, thermal and mechanical stresses, is presented and compared with experimental life-test data relevant to HV generator stator insulation. The algorithm for the estimation of the large number of model parameters is presented and the goodness-of-fit of the model discussed.
- 1 January 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 4 (6) , 800-805
Growth properties of sulfide trees in cables under dc stress
Investigations on the growth properties of sulfide tree in cable insulation, subjected to dc electric fields, are described in this paper. Measurements of electric strength and conductivity are correlated to tree growth, observed by optical and electron microscopy, during accelerated aging tests performed in sea water with hydrogen sulfide. It is shown that both electric strength and dc conductivity are very sensitive to the length and concentration of sulfide trees, and that the magnitude of the electric field affects tree shape and growth rate significantly.
- 1 January 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 4 (6) , 800-805
Growth properties of sulfide trees in cables under dc stress
Investigations on the growth properties of sulfide tree in cable insulation, subjected to dc electric fields, are described in this paper. Measurements of electric strength and conductivity are correlated to tree growth, observed by optical and electron microscopy, during accelerated aging tests performed in sea water with hydrogen sulfide. It is shown that both electric strength and dc conductivity are very sensitive to the length and concentration of sulfide trees, and that the magnitude of the electric field affects tree shape and growth rate significantly.
- 1 January 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Engineering Review
- Vol. 17 (1) , 36
A Comparison Between XLPE and EPR as Insulating Materials for High Voltage Cables
- 1 January 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Engineering Review
- Vol. 17 (1) , 36
A Comparison Between XLPE and EPR as Insulating Materials for High Voltage Cables