LELieselot van Erven

Lieselot van Erven

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lieselot van Erven has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Dutch Implantable Cardioverter–Defibrillator Decision Aid in Clinical Practice: A Stepped-Wedge Randomized Controlled Trial

    by Dilek Yilmaz, Anastasia D. Egorova, Robert Grauss, Han A. M. Spierenburg, Kevin Venooy, Leon P. M. van Woerkens, Ramon Robles de Medina, Martin J. Schalij, Lieselot van Erven

    Introduction: The role of shared decision making (SDM) has become increasingly pivotal, particularly in nuanced choices such as those involving implantable cardioverter–defibrillator (ICD) therapy. This study evaluates the impact of the Dutch ICD Decision Aid on SDM in patients up for ICD implantation or replacement. Methods: A stepped-wedge randomized controlled trial was conducted across 6 Dutch hospitals between February 2018 and September 2019, involving patients eligible for ICD implantation or pulse-generator exchange. SDM experiences of the patients and involved medical professionals were assessed using SDM-Q-9 and SDM-Q-Doc questionnaires, respectively. The Decisional Conflict Scale (DCS) scores measured effective decision making. The intervention group received the decision aid on top of standard care. Results: A total of 150 patients and 233 health care providers were included in the study. For health care providers, SDM scores did not differ: the SDM-Q-Doc median score was 36 (28–38) in the control phase and 35 (33–40) in the intervention phase ( P = 0.81). Patients in both the intervention and control groups demonstrated high SDM scores as well. Decisional conflict scores were low: the median DCS score was 12.5 (4.3–23.4) in the intervention phase and 16.4 (6.25–25.0) in the control phase ( P = 0.45). Patients with a higher education provided more correct answers to the theoretical knowledge questions. In addition, patients up for a pulse-generator exchange also had significantly more correct answers. Conclusions: Although the Dutch ICD Decision Aid did not result in significant differences in SDM scores or levels of decisional conflict between patient groups, both measures remained consistently favorable overall. The decision aid still holds promise as a valuable resource. Efforts should focus on refining decision-making tools and improving patient knowledge and the quality of patient-centered care. Highlights: A digital decision aid did not significantly increase shared decision-making (SDM) scores for patients and health care providers, as SDM levels were already high across all groups. Despite high SDM scores, patient knowledge about implantable cardioverter–defibrillator (ICD) therapy remained low, highlighting a gap in understanding. Patients with higher education or prior experience with ICDs demonstrated better knowledge retention, indicating the need for tailored educational interventions. The study emphasizes the ongoing challenge of ensuring unbiased, well-informed decision making in ICD therapy, especially during pulse-generator replacements.

  • Open Access

    One-Year Mortality in Patients Undergoing an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy Pulse Generator Replacement: Identifying Patients at Risk

    by Michelle Feijen, Anastasia D. Egorova, Teresa Kuijken, Marianne Bootsma, Martin J. Schalij, Lieselot van Erven

    Implantable cardioverter defibrillators (ICDs) significantly contribute to the prevention of sudden cardiac death in selected patients. However, it is essential to identify those who are likely to not have benefit from an ICD and to defer a pulse generator exchange. Easily implementable guidelines for individual risk stratification and decision making are lacking. This study investigates the 1-year mortality of patients who underwent an ICD or cardiac resynchronization therapy with defibrillator function (CRT-D) pulse generator replacement in a contemporary real-world tertiary hospital setting. The cause of death and patient- and procedure-related factors are stratified, and predictive values for 1-year mortality are evaluated. Patients with a follow-up of ≥365 days (or prior mortality) after an ICD or CRT-D exchange at the Leiden University Medical Center from 1 January 2018 until 31 December 2021 were eligible. In total, 588 patients were included (77% male, 69 [60–76] years old, 59% primary prevention, 46% ischemic cardiomyopathy and 37% mildly reduced left ventricular ejection fraction (LVEF)). Patients undergoing a CRT-D replacement or upgrade had a significantly higher 1-year all-cause mortality (10.7% and 11.9%, respectively) compared to patients undergoing ICD (2.8%) exchange (p = 0.002). LVEF ≤ 30%, New York Heart Association class ≥ 3, estimated glomerular filtration rate ≤ 30 mL/min/m2 and haemoglobin ≤ 7 mmol/L were independently associated with mortality within 1 year after pulse generator replacement. There is a growing need for prospectively validated risk scores to weight individualized risk of mortality with the expected ICD therapy benefit and to support a well-informed, shared decision-making process.


  • Open Access

    The development of a decision aid for shared decision making in the Dutch implantable cardioverter defibrillator patient population: A novel approach to patient education

    by Dilek Yilmaz, Anastasia D. Egorova, Martin J. Schalij, Han A. M. Spierenburg, Robert A. M. Verbunt, Lieselot van Erven

    Background: Counseling of Implantable Cardioverter-defibrillator (ICD) patients with regard to individual risks and benefits is challenging. An evidence-based decision aid tailored to the needs of Dutch ICD patients is not yet available. The objective of this pilot project was to structurally evaluate the current clinical practice in The Netherlands and the ICD patient experience, in order to develop an online decision aid to facilitate shared decision making in ICD procedures.Methods: Between June 2016 and December 2017, a Dutch web-based decision aid was developed according to the Patient Decision Aid Standards (IPDAS) using the RAND-UCLA/multi-stepped Delphi model. Development process consisted of 5 stages in which the Dutch clinical practice was reviewed (stage 1), patients’ needs and their history of decision making was structurally assessed (stages 2A and B) and a modified Delphi consensus process was performed with an expert panel consisting of representatives from different medical fields (stage 3). Results from stages 1–3 were used to design and structure the content of an online-based decision aid (stage 4) which was finally evaluated in a usability testing by patients in stage 5.Results and conclusion: This study describes the evidence-based approach to the development of the Dutch ICD decision aid. In our population, levels of shared decision-making experience were low. The ICD decision aid was structurally developed for the Dutch ICD patient population. Our upcoming multicenter stepped wedge clustered randomized trial will further evaluate the ICD decision aid in clinical practice.


  • Implantable cardioverter-defibrillators and the older patient: the Dutch clinical practice

    by Dilek Yilmaz, Anastasia D Egorova, Martin J Schalij, Lieselot van Erven

    Background and objective: Balance between benefit and burden of implantable cardioverter-defibrillator (ICD) therapy is more debatable in older patients, compared to younger patients. Of around 6000 yearly implanted ICDs in the Netherlands, 1:4 is received by patients ≥75 years. We aimed to evaluate the current clinical practice in the Netherlands for ICD implants and generator replacements, with a special focus on the older ICD patients. Research design and methods: Cardiologists from all Dutch ICD implanting centres (n = 28) were interviewed. Questions aimed to evaluate outpatient care, pre-operative patient assessment, end-of-life-care counselling, evaluation of social and cognitive wellbeing, clinical evaluation of all patients prior to ICD replacement, and the consideration of the option to downgrade or not replace a device. Results: Implanting cardiologists from all 28 implanting centres were approached for an interview. Response rate was 86%. Management appeared diverse. An age ≥80 years was consistently reported as incentive for more extensive patient evaluation. Patients were invited for counselling prior to device replacements in only the minority (46%) of hospitals. Downgrade or non-replacement was performed in rare cases. End-of-life care discussions were not standard procedure in 67% of the hospitals. Evaluation of social and cognitive wellbeing of patients was based solely on the general clinical impression of the physician in 83%, or not at all assessed in 8% of the centres. Discussion and implication: A structured framework for care and evaluation of cognitive and/or physical limitations is currently absent in most hospitals. At time of ICD (re-)evaluation, several factors may be considered before deciding on (continuation of) ICD therapy: patient preferences and comorbidity, the need for pacemaker therapy, primary vs. secondary prevention, procedural risks, and patient preferences.


  • Mechanical extraction of cardiac implantable electronic devices leads with long dwell time: Efficacy and safety of the step up approach

    by Leontine M. H. Lensvelt, Anastasia D. Egorova, Martin J. Schalij, Dilek Yilmaz, Charles Kennergren, Marianne Bootsma, Lieselot van Erven

    The aim of this study was to evaluate the efficacy and safety of the stepwise mechanical transvenous lead extraction approach in a patient population with chronically implanted transvenous leads with a long dwell time.From January 2014 till December 2018, all lead extractions with lead dwell time ≥5 years performed at our tertiary centre were retrospectively analysed. A total of 173 leads, from 78 patients (median age 68 years; 81% male) with a median dwell time of 9 years (interquartile range [IQR] 5) were extracted, with three or more leads in 42% of the patients. Right atrial leads: 41%; right ventricular pacing leads: 16%; implantable cardioverter‐defibrillator (ICD) leads: 31% (72% dual coil); coronary sinus leads: 12%. The majority (75%) of the leads had an active fixation. Most frequent indication for extraction was pocket infection/erosion (76%). Overall clinical success was 97%, and complete procedural success was 93%. Venous patency, assessed with venous angiography, was well preserved in 93% of the cases. The overall procedural complication rate was 3.8% (2.6% major and 1.3% minor).Despite the complexity of the population and a very long dwell time (median 9 years), a clinical success rate of 97% was achieved with the stepwise mechanical approach. Analysis of impeding progression of pectoral extraction suggests that dense fibrosis and sharp lead curvature in the transvenous trajectory pose a challenge. Complication rate was low, and acute venous patency was generally well preserved.


  • Long-Term Echocardiographic Outcome in Super-Responders to Cardiac Resynchronization Therapy and the Association With Mortality and Defibrillator Therapy

    by Aafke C. van der Heijden, Ulas Höke, Joep Thijssen, C. Jan Willem Borleffs, Ron Wolterbeek, Martin J. Schalij, Lieselot van Erven


  • TIMELY DEACTIVATION OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR-THERAPY: WORK IN PROGRESS

    by Dilek Yilmaz, Aafke Van Der Heijden, Joep Thijssen, Martin Schalij, Lieselot van Erven

  • The clinical course of patients with implantable cardioverter-defibrillators: Extended experience on clinical outcome, device replacements, and device-related complications

    by Aafke C. van der Heijden, C. Jan Willem Borleffs, Maurits S. Buiten, Joep Thijssen, Johannes B. van Rees, Suzanne C. Cannegieter, Martin J. Schalij, Lieselot van Erven


  • How adequate are the current methods of lead extraction? A review of the efficiency and safety of transvenous lead extraction methods

    by Maurits S. Buiten, Aafke C. van der Heijden, Martin J. Schalij, Lieselot van Erven

    Currently several extraction tools are available in order to allow safe and successful transvenous lead extraction (TLE) of pacemaker and ICD leads; however, no directives exist to guide physicians in their choice of extraction tools and approaches. To aim of the current review is to provide an overview of the success and complication rates of different extraction methods and tools available. A comprehensive search of all published literature was conducted in the databases of PubMed, Embase, Web of Science, and Central. Included papers were original articles describing a specific method of TLE and the corresponding success rates of at least 50 patients. Fifty-three studies were included; the majority (56%) utilized 2 (1-4) different venous extraction approaches (subclavian and femoral), the median number of extraction tools used was 3 (1-6). A stepwise approach was utilized in the majority of the studies, starting with simple traction which resulted in successful TLE in 7–85% of the leads. When applicable the procedure was continued with non-powered tools resulting in a successful extraction of 34–87% leads. Subsequently, powered tools were applied whereby success rates further increased to 74–100%. The final step in TLE was usually utilized by femoral snare leading to an overall TLE success rate of 96–100%. The median procedure-related mortality and major complication described were, respectively, 0% (0–3%) and 1% (0–7%) per patient. In conclusion, a stepwise extraction approach can result in a clinical successful TLE in up to 100% of the leads with a relatively low risk of procedure-related mortality and complications.