  • International Biological Standards for Coagulation Factors and Inhibitors

    by Anthony R. Hubbard

    The use of international biological standards during the last 30 years has proved extremely successful in promoting global harmonization of estimates between laboratories and methods. Experience has led to the identification of physical criteria essential for standards to be suitable for long-term use. High precision of liquid filling coupled with low residual moisture and oxygen and the use of sealed glass ampoules have been found consistent with homogeneous and stable International Standards (ISs). Most plasma coagulation factors and inhibitors are calibrated in International Units (IU), which are defined as the amount of analyte in 1 mL of normal pooled plasma. Adoption of the IU has provided clarity in the definition of normal and abnormal states and has facilitated dose calculation for replacement therapy. The assay of like-versus-like materials (e.g., concentrate versus concentrate) has been found to improve interlaboratory agreement and there are now both plasma and concentrate ISs available for many coagulation factors and inhibitors. Studies into the assay of recombinant factor VIII have indicated that additional measures, such as modifications to assay methodology, are necessary to reduce interlaboratory variability. This experience may prove valuable in the future, when we have to deal increasingly with the challenges to standardization associated with the products of bioengineering.


  • von Willebrand Factor Standards for Plasma and Concentrate Testing

    by Anthony R. Hubbard

    The wide range of plasma von Willebrand factor (vWF) levels in the normal population makes vWF an ideal candidate for calibration in World Health Organization International Standards (WHO IS). Calibration of the WHO IS Plasma for vWF:antigen (vWF:Ag), vWF:ristocetin cofactor activity (vWF:RCo), and vWF:collagen-binding activity (vWF:CB) addresses the need to reconcile the original definition of the International Unit (IU) in fresh normal plasma with continuity between replacement freeze-dried preparations, whereas calibration of the WHO IS Concentrate aims to maintain equivalence between the IU used for the estimation of vWF in plasma (diagnosis) and the IU used for the potency labeling of therapeutic concentrates (replacement therapy). The latter objective was achieved through the calibration of the WHO 1st IS vWF Concentrate, for vWF:Ag and vWF:RCo, by assay directly relative to the WHO IS Plasma. Calibration of the WHO IS Concentrate for vWF:CB was not possible due to large interlaboratory and intermethod discrepancies, and resolution of this problem may require the use of recommended methodology. There is evidence that the use of the WHO IS Concentrate leads to considerable reduction in interlaboratory variability for vWF estimates in therapeutic concentrates and hence the “assay like versus like” principle should be applied.


  • A multi-centre collaborative study on the potency estimation of ReFacto

    by Dawn Sands, Eva Sandberg, Rainer Seitz, Trevor Barrowcliffe, Anthony Hubbard

    Schattauer GmbH - Verlag für Medizin und Naturwissenschaften ist ein renommierter Herausgeber von Fachbüchern, -zeitschriften und -software. Besuchen Sie unser Internetangebot mit Onlinezugang zu unseren Zeitschriftenartikeln


    • 1 September 2002
      • Vol. 88  (3) , 380-6

    Standardisation of von Willebrand Factor in therapeutic concentrates: calibration of the 1st International Standard for von Willebrand Factor concentrate (00/514).

    by Anthony R Hubbard, Dawn Sands, Andrew C Chang, Claudine Mazurier

    An international study involving 26 laboratories assayed two candidate von Willebrand Factor (VWF) concentrates (B and C) for VWF:Antigen (VWF:Ag), VWF:Ristocetin Cofactor (VWF:RCo) and VWF:Collagen binding (VWF:CB) relative to the 4th International Standard Factor VIII/VWF Plasma (4th IS Plasma) (97/586). Estimates of VWF:Ag showed good agreement between different methods, for both candidates, and the overall combined means were 11.01 IU/ml with inter-laboratory variability (GCV) of 10.9% for candidate B and 14.01 IU/ml (GCV 11.8%) for candidate C. Estimates of VWF:RCo showed no significant difference between methods for both candidates and gave overall means of 9.38 IU/ml (GCV 23.7%) for candidate B and 10.19 IU/ml (GCV 24.4%) for candidate C. Prior to the calibration of the candidates for VWF:CB it was necessary to calibrate the 4th IS Plasma relative to local frozen normal plasma pools; there was good agreement between different collagen reagents and an overall mean of 0.83 IU per ampoule (GCV 11.8%) was assigned. In contrast, estimates of VWF:CB in both candidates showed large differences between collagen reagents with inter-laboratory GCV's of 40%. Candidate B (00/514) was established as the 1st International Standard von Willebrand Factor Concentrate by the WHO Expert Committee on Biological Standardisation in November 2001 with assigned values for VWF:Ag (11.0 IU/ampoule) and VWF:RCo (9.4 IU/ampoule). Large inter-laboratory variability of estimates precluded the assignment of a value for VWF:CB.


  • Open Access

    Activation profiles of factor VIII in concentrates reflect one‐stage/chromogenic potency discrepancies

    by Anthony R. Hubbard, Lynne J. Weller, Sally A. Bevan

    Summary.  We have investigated the possibility that differences in the profile of factor VIII (FVIII) activation, by thrombin, may help to explain the one‐stage/chromogenic potency discrepancies in two therapeutic concentrates. A Method M concentrate and a recombinant B‐domain‐deleted (B‐DD) concentrate were found to have one‐stage/chromogenic ratios of approximately 1·15 and 0·70, respectively, relative to the World Health Organization (WHO) 6th International Standard (IS) FVIII concentrate, whether pre‐diluted in FVIII‐deficient plasma or buffer (± von Willebrand factor, VWF). The activation of FVIII, by thrombin, was followed in a buffer medium (± VWF) and all three concentrates showed similar times to reach peak FVIII coagulation (FVIII:C) activity. However, despite the use of equivalent amounts of FVIII:C for all three concentrates, the B‐DD concentrate reached a higher peak level and maintained higher FVIII:C compared with the WHO 6th IS throughout the incubation period, whereas the Method M concentrate reached a lower peak level and maintained lower FVIII:C throughout the incubation period. We propose that the higher levels of FVIII:C found with the B‐DD concentrate and the lower levels with the Method M concentrate, following activation, may be reflected in the potencies obtained by the chromogenic method and may be consistent with one‐stage/chromogenic ratios of < 1·0 and > 1·0 respectively.


  • Standardisation of von Willebrand Factor in Therapeutic Concentrates: Calibration of the 1st International Standard for von Willebrand Factor Concentrate (00/514)

    by Dawn Sands, Andrew C. Chang, Claudine Mazurier, Anthony R. Hubbard

    An international study involving 26 laboratories assayed two candidate von Willebrand Factor (VWF) concentrates (B and C) for VWF:Antigen (VWF:Ag), VWF:Ristocetin Cofactor (VWF:RCo) and VWF:Collagen binding (VWF:CB) relative to the 4th International Standard Factor VIII/VWF Plasma (4th IS Plasma) (97/586). Estimates of VWF:Ag showed good agreement between different methods, for both candidates, and the overall combined means were 11.01 IU/ml with inter-laboratory variability (GCV) of 10.9% for candidate B and 14.01 IU/ml (GCV 11.8%) for candidate C. Estimates of VWF:RCo showed no significant difference between methods for both candidates and gave overall means of 9.38 IU/ml (GCV 23.7%) for candidate B and 10.19 IU/ml (GCV 24.4%) for candidate C. Prior to the calibration of the candidates for VWF:CB it was necessary to calibrate the 4th IS Plasma relative to local frozen normal plasma pools; there was good agreement between different collagen reagents and an overall mean of 0.83 IU per ampoule (GCV 11.8%) was assigned. In contrast, estimates of VWF:CB in both candidates showed large differences between collagen reagents with inter-laboratory GCV’s of 40%. Candidate B (00/514) was established as the 1st International Standard von Willebrand Factor Concentrate by the WHO Expert Committee on Biological Standardisation in November 2001 with assigned values for VWF:Ag (11.0 IU/ampoule) and VWF:RCo (9.4 IU/ampoule). Large inter-laboratory variability of estimates precluded the assignment of a value for VWF:CB.


  • Potency estimation of recombinant factor VIII: effect of assay method and standard

    by Anthony R. Hubbard, Sally A. Bevan, Lynne J. Weller

    Large potency discrepancies between the chromogenic and one‐stage clotting methods have been reported for patients' plasma samples following the infusion of recombinant factor VIII (rFVIII) concentrates. We have investigated the potency estimation of two different full‐length rFVIII concentrates using both assay methods relative to both plasma and concentrate standards. Potencies by the chromogenic method were significantly higher (53% and 45%) than potencies by the one‐stage clotting method when a plasma standard was used. In contrast, there was no significant potency difference between methods when a concentrate standard was used. Time‐course studies into thrombin and activated factor X (FXa) generation, in modified clotting and chromogenic methods, respectively, revealed that the two rFVIII concentrates behaved very similarly to the concentrate standard, whereas the plasma standard showed slightly more rapid thrombin generation and markedly slower FXa generation. The different behaviour of rFVIII and plasma FVIII in the chromogenic method is proposed as the main cause of the methods‐based potency discrepancy. The results support the use of a concentrate standard to measure rFVIII in post‐infusion plasma.