Etta D. Pisano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Etta D. Pisano has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Cherie Kuzmiak
2 shared publications- Elodia B. Cole
University of North Carolina at Chapel Hill
2 shared publications Laurie L. Fajardo
2 shared publicationsMarcia Koomen
2 shared publicationsMartin J. Yaffe
2 shared publicationsR. Eugene Johnston
2 shared publications
Latest Publications
- Open Access
- 20 January 2009
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 9 (1) , 4
Bias in trials comparing paired continuous tests can cause researchers to choose the wrong screening modality
To compare the diagnostic accuracy of two continuous screening tests, a common approach is to test the difference between the areas under the receiver operating characteristic (ROC) curves. After study participants are screened with both screening tests, the disease status is determined as accurately as possible, either by an invasive, sensitive and specific secondary test, or by a less invasive, but less sensitive approach. For most participants, disease status is approximated through the less sensitive approach. The invasive test must be limited to the fraction of the participants whose results on either or both screening tests exceed a threshold of suspicion, or who develop signs and symptoms of the disease after the initial screening tests.
- 20 January 2009
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 9 (1) , 4
Open AccessBias in trials comparing paired continuous tests can cause researchers to choose the wrong screening modality
To compare the diagnostic accuracy of two continuous screening tests, a common approach is to test the difference between the areas under the receiver operating characteristic (ROC) curves. After study participants are screened with both screening tests, the disease status is determined as accurately as possible, either by an invasive, sensitive and specific secondary test, or by a less invasive, but less sensitive approach. For most participants, disease status is approximated through the less sensitive approach. The invasive test must be limited to the fraction of the participants whose results on either or both screening tests exceed a threshold of suspicion, or who develop signs and symptoms of the disease after the initial screening tests.
- 1 August 2006
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 3 (8) , 583-585
Digital Mammography: What Next?
- 1 August 2006
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 3 (8) , 583-585
Digital Mammography: What Next?
- 1 February 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 234 (2) , 353-362
Digital Mammography
In digital mammography, the processes of image acquisition, display, and storage are separated, which allows optimization of each. Radiation transmitted through the breast is absorbed by an electronic detector, the response of which is faithful over a wide range of intensities. Once this information is recorded, it can be displayed by using computer image-processing techniques to allow arbitrary settings of image brightness and contrast, without the need for further exposure to the patient. In this article, the current state of the art in technology for digital mammography and data from clinical trials that support the use of the technology will be reviewed. In addition, several potentially useful applications that are being developed with digital mammography will be described.
- 1 February 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 234 (2) , 353-362
Digital Mammography
In digital mammography, the processes of image acquisition, display, and storage are separated, which allows optimization of each. Radiation transmitted through the breast is absorbed by an electronic detector, the response of which is faithful over a wide range of intensities. Once this information is recorded, it can be displayed by using computer image-processing techniques to allow arbitrary settings of image brightness and contrast, without the need for further exposure to the patient. In this article, the current state of the art in technology for digital mammography and data from clinical trials that support the use of the technology will be reviewed. In addition, several potentially useful applications that are being developed with digital mammography will be described.
- 31 May 2004
- Published by Elsevier in Academic Radiology
- Vol. 11 (5) , 536-543
Factors affecting increasing radiation dose for mammography in North Carolina from 1997 through 2001: An analysis of food and drug administration annual surveys1
- 31 May 2004
- Published by Elsevier in Academic Radiology
- Vol. 11 (5) , 536-543
Factors affecting increasing radiation dose for mammography in North Carolina from 1997 through 2001: An analysis of food and drug administration annual surveys1
- 1 June 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 219 (3) , 785-792
Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V
To determine the diagnostic accuracy of ultrasonographically (US) and stereotactically guided fine-needle aspiration biopsy (FNAB) in the diagnosis of nonpalpable breast lesions. At 18 institutions, 442 women who underwent 22-25-gauge imaging-guided FNAB were enrolled. Definitive surgical, core-needle biopsy, and/or follow-up information was available for 423 (95.7%) of these women. The reference standard was established from additional clinical and imaging information for an additional six (1.4%) women who did not undergo further histopathologic evaluation. The FNAB protocol was standardized at all institutions, and all specimens were reread by one of two expert cytopathologists. When insufficient samples were included in the analysis and classified as positive, the sensitivity and specificity of FNAB were 85%-88% and 55.6%-90.5%, respectively; accuracy ranged from 62.2% to 89.2%. The diagnostic accuracy of FNAB was significantly better for detection of masses than for detection of calcifications (67.3% vs. 53.8%, P =.006) and with US guidance than with stereotactic guidance (77.2% vs. 58.9%; P =.002). FNAB of nonpalpable breast lesions has limited value given the high insufficient sample rate and greater diagnostic accuracy of other interventions, including core-needle biopsy and needle-localized open surgical biopsy.
- 1 June 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 219 (3) , 785-792
Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V
To determine the diagnostic accuracy of ultrasonographically (US) and stereotactically guided fine-needle aspiration biopsy (FNAB) in the diagnosis of nonpalpable breast lesions. At 18 institutions, 442 women who underwent 22-25-gauge imaging-guided FNAB were enrolled. Definitive surgical, core-needle biopsy, and/or follow-up information was available for 423 (95.7%) of these women. The reference standard was established from additional clinical and imaging information for an additional six (1.4%) women who did not undergo further histopathologic evaluation. The FNAB protocol was standardized at all institutions, and all specimens were reread by one of two expert cytopathologists. When insufficient samples were included in the analysis and classified as positive, the sensitivity and specificity of FNAB were 85%-88% and 55.6%-90.5%, respectively; accuracy ranged from 62.2% to 89.2%. The diagnostic accuracy of FNAB was significantly better for detection of masses than for detection of calcifications (67.3% vs. 53.8%, P =.006) and with US guidance than with stereotactic guidance (77.2% vs. 58.9%; P =.002). FNAB of nonpalpable breast lesions has limited value given the high insufficient sample rate and greater diagnostic accuracy of other interventions, including core-needle biopsy and needle-localized open surgical biopsy.
- 1 April 2001
- Published by Wiley in Seminars in Surgical Oncology
- Vol. 20 (3) , 181-186
What every surgical oncologist should know about digital mammography.
- 1 April 2001
- Published by Wiley in Seminars in Surgical Oncology
- Vol. 20 (3) , 181-186
What every surgical oncologist should know about digital mammography.
- 1 September 2000
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 20 (5) , 1479-1491
Image Processing Algorithms for Digital Mammography: A Pictorial Essay
Digital mammography systems allow manipulation of fine differences in image contrast by means of image processing algorithms. Different display algorithms have advantages and disadvantages for the specific tasks required in breast imaging-diagnosis and screening. Manual intensity windowing can produce digital mammograms very similar to standard screen-film mammograms but is limited by its operator dependence. Histogram-based intensity windowing improves the conspicuity of the lesion edge, but there is loss of detail outside the dense parts of the image. Mixture-model intensity windowing enhances the visibility of lesion borders against the fatty background, but the mixed parenchymal densities abutting the lesion may be lost. Contrast-limited adaptive histogram equalization can also provide subtle edge information but might degrade performance in the screening setting by enhancing the visibility of nuisance information. Unsharp masking enhances the sharpness of the borders of mass lesions, but this algorithm may make even an indistinct mass appear more circumscribed. Peripheral equalization displays lesion details well and preserves the peripheral information in the surrounding breast, but there may be flattening of image contrast in the nonperipheral portions of the image. Trex processing allows visualization of both lesion detail and breast edge information but reduces image contrast.
- 1 September 2000
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 20 (5) , 1479-1491
Image Processing Algorithms for Digital Mammography: A Pictorial Essay
Digital mammography systems allow manipulation of fine differences in image contrast by means of image processing algorithms. Different display algorithms have advantages and disadvantages for the specific tasks required in breast imaging-diagnosis and screening. Manual intensity windowing can produce digital mammograms very similar to standard screen-film mammograms but is limited by its operator dependence. Histogram-based intensity windowing improves the conspicuity of the lesion edge, but there is loss of detail outside the dense parts of the image. Mixture-model intensity windowing enhances the visibility of lesion borders against the fatty background, but the mixed parenchymal densities abutting the lesion may be lost. Contrast-limited adaptive histogram equalization can also provide subtle edge information but might degrade performance in the screening setting by enhancing the visibility of nuisance information. Unsharp masking enhances the sharpness of the borders of mass lesions, but this algorithm may make even an indistinct mass appear more circumscribed. Peripheral equalization displays lesion details well and preserves the peripheral information in the surrounding breast, but there may be flattening of image contrast in the nonperipheral portions of the image. Trex processing allows visualization of both lesion detail and breast edge information but reduces image contrast.
- 1 March 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (3) , 895-901
Human Breast Cancer Specimens: Diffraction-enhanced Imaging with Histologic Correlation—Improved Conspicuity of Lesion Detail Compared with Digital Radiography
Seven breast cancer specimens were examined with diffraction-enhanced imaging at 18 keV with a silicon crystal with use of the silicon 333 reflection in Bragg mode. Images were compared with digital radiographs of the specimen, and regions of increased detail were identified. Six of the seven cases (86%) showed enhanced visibility of surface spiculation that correlated with histopathologic information, including extension of tumor into surrounding tissue.
- 1 March 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (3) , 895-901
Human Breast Cancer Specimens: Diffraction-enhanced Imaging with Histologic Correlation—Improved Conspicuity of Lesion Detail Compared with Digital Radiography
Seven breast cancer specimens were examined with diffraction-enhanced imaging at 18 keV with a silicon crystal with use of the silicon 333 reflection in Bragg mode. Images were compared with digital radiographs of the specimen, and regions of increased detail were identified. Six of the seven cases (86%) showed enhanced visibility of surface spiculation that correlated with histopathologic information, including extension of tumor into surrounding tissue.
- 1 January 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (1) , 26-28
Current Status of Full-Field Digital Mammography
- 1 January 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (1) , 26-28
Current Status of Full-Field Digital Mammography
- 1 August 1998
- Published by SAGE Publications in Breast Disease
- Vol. 10 (3-4) , 221-230
Augmented Reality Applied to Ultrasound-Guided Breast Cyst Aspiration
- 1 August 1998
- Published by SAGE Publications in Breast Disease
- Vol. 10 (3-4) , 221-230
Augmented Reality Applied to Ultrasound-Guided Breast Cyst Aspiration