Thomas K. F. Foo
Research Subjects
Thomas K. F. Foo has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Peter L. Choyke
Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, Maryland
4 shared publicationsVincent B. Ho
Department of Radiology, Uniformed Services University of the Health Sciences, Bethesda, Maryland
4 shared publicationsMaureen N. Hood
Department of Radiology, Uniformed Services University of the Health Sciences, Bethesda, Maryland
3 shared publications- Vincent B. Ho
Department of Radiology, Uniformed Services University of the Health Sciences, Bethesda, Maryland 20814, USA
3 shared publications - David A. Bluemke
Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
2 shared publications Hani B. Marcos
Diagnostic Radiology Department, Clinical Center, National Institutes of Health, Bethesda, Maryland
2 shared publications
Latest Publications
- 1 June 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 235 (3) , 1025-1030
Feasibility of Integrating High-Spatial-Resolution 3D Breath-hold Coronary MR Angiography with Myocardial Perfusion and Viability Examinations
The study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. All subjects provided informed consent. Three-dimensional breath-hold coronary magnetic resonance (MR) angiography with use of steady-state free precession was performed in 12 patients up to 20 minutes after 0.2 mmol gadolinium-based contrast material per kilogram of body weight was administered. Within 24 heartbeats, a spatial resolution of up to 1.0 x 1.2 x 2.0 mm was achieved. Sixty-five (82%) of the 79 visualized coronary artery segments had a grade of 3 or 4 on a four-point scale of depiction in which grade 4 indicated excellent depiction. Twenty-seven percent (n = 21) of the 79 segments were assigned a grade of 4; 56% (n = 44), a grade of 3; 16% (n = 13), a grade of 2; and 1% (n = 1), a grade of 1. Coronary MR angiography performed as part of a first-pass myocardial perfusion and viability assessment MR imaging examination is feasible and does not involve additional imaging time.
- 1 June 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 235 (3) , 1025-1030
Feasibility of Integrating High-Spatial-Resolution 3D Breath-hold Coronary MR Angiography with Myocardial Perfusion and Viability Examinations
The study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. All subjects provided informed consent. Three-dimensional breath-hold coronary magnetic resonance (MR) angiography with use of steady-state free precession was performed in 12 patients up to 20 minutes after 0.2 mmol gadolinium-based contrast material per kilogram of body weight was administered. Within 24 heartbeats, a spatial resolution of up to 1.0 x 1.2 x 2.0 mm was achieved. Sixty-five (82%) of the 79 visualized coronary artery segments had a grade of 3 or 4 on a four-point scale of depiction in which grade 4 indicated excellent depiction. Twenty-seven percent (n = 21) of the 79 segments were assigned a grade of 4; 56% (n = 44), a grade of 3; 16% (n = 13), a grade of 2; and 1% (n = 1), a grade of 1. Coronary MR angiography performed as part of a first-pass myocardial perfusion and viability assessment MR imaging examination is feasible and does not involve additional imaging time.
- Open Access
- 19 May 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (6) , 1484-1489
Enhanced viability imaging: Improved contrast in myocardial delayed enhancement using dual inversion time subtraction
In delayed contrast‐enhanced MRI for the assessment of myocardial viability, the TI time in a gated inversion‐recovery segmented gradient echo sequence is usually selected to null signal from normal myocardium. Although this TI time generates good contrast between the enhancing infarcted tissue and normal myocardium, there is usually less contrast between the infarct and the blood pool. A subtractive technique utilizing two acquisitions at a long and short TI time is proposed to improve the delineation between infarct‐blood and infarct‐myocardium. The concept was demonstrated in six mongrel dogs with reperfused myocardial infarction. Infarct‐normal myocardium contrast (signal difference) using the proposed enhanced viability imaging (ENVI) technique was 142 ± 50% (P < 0.001) that of standard magnitude inversion recovery (IR), while at the same TI time for the primary image, infarct‐blood contrast, was 247 ± 136% (P < 0.002) that of magnitude IR. Accounting for increased noise due to the subtraction, signal difference‐to‐noise ratios (SDNR) did not show a significant change for infarct‐myocardium but infarct‐blood SDNR for ENVI was 174 ± 105% that of magnitude‐IR (P < 0.03). Thus, marked improvement in the delineation of the infarcted zone was noted over a range of TI times. Magn Reson Med 53:1484–1489, 2005.
- 19 May 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (6) , 1484-1489
Open AccessEnhanced viability imaging: Improved contrast in myocardial delayed enhancement using dual inversion time subtraction
In delayed contrast‐enhanced MRI for the assessment of myocardial viability, the TI time in a gated inversion‐recovery segmented gradient echo sequence is usually selected to null signal from normal myocardium. Although this TI time generates good contrast between the enhancing infarcted tissue and normal myocardium, there is usually less contrast between the infarct and the blood pool. A subtractive technique utilizing two acquisitions at a long and short TI time is proposed to improve the delineation between infarct‐blood and infarct‐myocardium. The concept was demonstrated in six mongrel dogs with reperfused myocardial infarction. Infarct‐normal myocardium contrast (signal difference) using the proposed enhanced viability imaging (ENVI) technique was 142 ± 50% (P < 0.001) that of standard magnitude inversion recovery (IR), while at the same TI time for the primary image, infarct‐blood contrast, was 247 ± 136% (P < 0.002) that of magnitude IR. Accounting for increased noise due to the subtraction, signal difference‐to‐noise ratios (SDNR) did not show a significant change for infarct‐myocardium but infarct‐blood SDNR for ENVI was 174 ± 105% that of magnitude‐IR (P < 0.03). Thus, marked improvement in the delineation of the infarcted zone was noted over a range of TI times. Magn Reson Med 53:1484–1489, 2005.
- 1 March 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 230 (3) , 845-851
Myocardial Viability: Breath-hold 3D MR Imaging of Delayed Hyperenhancement with Variable Sampling in Time
A method for visualizing myocardial infarction with a three-dimensional (3D) breath-hold gated acquisition was examined. By using variable sampling in time, whole heart coverage with a single volume acquisition was achieved in 24 heart beats. In a study of 35 patients, in whom 3D volume acquisition was compared with a two-dimensional (2D) acquisition, all regions of myocardial infarction were correctly identified at 3D examination. The mean imaging time for 12 section locations was 8.0 minutes +/- 3.0 with a 2D approach compared with 22 seconds +/- 4 with a 3D approach (P <.001). Advantages were also noted for infarct contrast-to-noise ratio: 60 +/- 37 for 3D versus 33 +/- 20 for 2D imaging (P <.001). No significant differences (P >.05) were noted at qualitative assessment of myocardial suppression, endocardial border visualization, respiratory and cardiac motion artifacts, or confidence of transmurality of the infarct.
- 1 March 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 230 (3) , 845-851
Myocardial Viability: Breath-hold 3D MR Imaging of Delayed Hyperenhancement with Variable Sampling in Time
A method for visualizing myocardial infarction with a three-dimensional (3D) breath-hold gated acquisition was examined. By using variable sampling in time, whole heart coverage with a single volume acquisition was achieved in 24 heart beats. In a study of 35 patients, in whom 3D volume acquisition was compared with a two-dimensional (2D) acquisition, all regions of myocardial infarction were correctly identified at 3D examination. The mean imaging time for 12 section locations was 8.0 minutes +/- 3.0 with a 2D approach compared with 22 seconds +/- 4 with a 3D approach (P <.001). Advantages were also noted for infarct contrast-to-noise ratio: 60 +/- 37 for 3D versus 33 +/- 20 for 2D imaging (P <.001). No significant differences (P >.05) were noted at qualitative assessment of myocardial suppression, endocardial border visualization, respiratory and cardiac motion artifacts, or confidence of transmurality of the infarct.
- Open Access
- 26 September 2002
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (4) , 699-706
MR angiography using steady‐state free precession
Contrast‐enhanced MR angiography (CE‐MRA) using steady‐state free precession (SSFP) pulse sequences is described. Using SSFP, vascular structures can be visualized with high signal‐to‐noise ratio (SNR) at a substantial (delay) time after the initial arterial pass of contrast media. The peak blood SSFP signal was diminished by <20% 30 min after the initial administration of 0.2 mmol/kg of Gd‐chelate. The proposed method allows a second opportunity to study arterial or venous structures with high image SNR and high spatial resolution. A mask subtraction scheme using spin echo SSFP‐S(−) acquisition is also described to reduce stationary background signal from the delayed SSFP angiography images. Magn Reson Med 48:699–706, 2002.
- 26 September 2002
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (4) , 699-706
Open AccessMR angiography using steady‐state free precession
Contrast‐enhanced MR angiography (CE‐MRA) using steady‐state free precession (SSFP) pulse sequences is described. Using SSFP, vascular structures can be visualized with high signal‐to‐noise ratio (SNR) at a substantial (delay) time after the initial arterial pass of contrast media. The peak blood SSFP signal was diminished by <20% 30 min after the initial administration of 0.2 mmol/kg of Gd‐chelate. The proposed method allows a second opportunity to study arterial or venous structures with high image SNR and high spatial resolution. A mask subtraction scheme using spin echo SSFP‐S(−) acquisition is also described to reduce stationary background signal from the delayed SSFP angiography images. Magn Reson Med 48:699–706, 2002.
- 1 June 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 219 (3) , 835-841
High-Spatial-Resolution Multistation MR Imaging of Lower-Extremity Peripheral Vasculature with Segmented Volume Acquisition: Feasibility Study
A method of three-station three-dimensional magnetic resonance (MR) angiography of the lower extremities with segmented volume acquisition is presented. Three-dimensional MR angiographic data were acquired in two passes, with the central k-space views acquired during the arterial phase for the more proximal stations. This allowed a faster bolus injection rate and potentially improved visualization of the tibioperoneal arteries.
- 1 June 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 219 (3) , 835-841
High-Spatial-Resolution Multistation MR Imaging of Lower-Extremity Peripheral Vasculature with Segmented Volume Acquisition: Feasibility Study
A method of three-station three-dimensional magnetic resonance (MR) angiography of the lower extremities with segmented volume acquisition is presented. Three-dimensional MR angiographic data were acquired in two passes, with the central k-space views acquired during the arterial phase for the more proximal stations. This allowed a faster bolus injection rate and potentially improved visualization of the tibioperoneal arteries.
- 23 April 2001
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 13 (5) , 714-721
Preferential arterial imaging using gated thick-slice gadolinium-enhanced phase-contrast acquisition in peripheral MRA
- 23 April 2001
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 13 (5) , 714-721
Preferential arterial imaging using gated thick-slice gadolinium-enhanced phase-contrast acquisition in peripheral MRA
- Open Access
- 19 October 2000
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 12 (5) , 769-775
Bolus‐chase peripheral 3D MRA using a dual‐rate contrast media injection
- 19 October 2000
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 12 (5) , 769-775
Open AccessBolus‐chase peripheral 3D MRA using a dual‐rate contrast media injection
- 1 January 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (1) , 283-289
Vessel Tracking: Prospective Adjustment of Section-selective MR Angiographic Locations for Improved Coronary Artery Visualization over the Cardiac Cycle
To follow the motion of the coronary artery in magnetic resonance angiography, the authors evaluated vessel tracking, a method for prospective adjustment of the section location as a function of the delay from the cardiac trigger. In 10 volunteers and four patients, this method allowed the vessel to be maintained in the plane of acquisition throughout the cardiac cycle. With a single-phase multisection sequence, vessel-tracking acquisitions had an efficiency of 0.68 +/- 0.04 for both the right and left coronary arteries compared with 0.19 +/- 0.03 for a non-vessel-tracking acquisition (P < .001).
- 1 January 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 214 (1) , 283-289
Vessel Tracking: Prospective Adjustment of Section-selective MR Angiographic Locations for Improved Coronary Artery Visualization over the Cardiac Cycle
To follow the motion of the coronary artery in magnetic resonance angiography, the authors evaluated vessel tracking, a method for prospective adjustment of the section location as a function of the delay from the cardiac trigger. In 10 volunteers and four patients, this method allowed the vessel to be maintained in the plane of acquisition throughout the cardiac cycle. With a single-phase multisection sequence, vessel-tracking acquisitions had an efficiency of 0.68 +/- 0.04 for both the right and left coronary arteries compared with 0.19 +/- 0.03 for a non-vessel-tracking acquisition (P < .001).
- Open Access
- 31 August 1999
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 42 (3) , 548-553
A computationally efficient method for tracking reference position displacements for motion compensation in magnetic resonance imaging
- 31 August 1999
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 42 (3) , 548-553
Open AccessA computationally efficient method for tracking reference position displacements for motion compensation in magnetic resonance imaging
- 1 May 1999
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 9 (2) , 263-284
CONTRAST-ENHANCED CAROTID MR ANGIOGRAPHY: Imaging Principles and Physics
- 1 May 1999
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 9 (2) , 263-284
CONTRAST-ENHANCED CAROTID MR ANGIOGRAPHY: Imaging Principles and Physics