MBMefkur Bakan

Mefkur Bakan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mefkur Bakan has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prospective evaluation of remifentanil‑propofol mixture for total intravenous anesthesia: A randomized controlled study

    by Mefkur Bakan, Tarik Umutoglu, Ufuk Topuz, Emine Yilmaz Guler, Harun Uysal, Erdogan Ozturk

    Application of total intravenous anesthesia (TIVA) may be considered as unpractical when compared with inhalational anesthesia. Although it is mostly not recommended, mixing intravenous agents is popular in clinical practice. The aim of the present study was to investigate the suitability of using remifentanil‑propofol mixture (MIXTIVA) for TIVA. Adult patients with an American Society of Anesthesiologists grade of I‑II scheduled for elective thyroidectomy were randomly allocated to 3 groups (n=32 for each) to receive TIVA with remifentanil and propofol infusions separately (control group, Group I) or with MIXTIVA infusion that contained remifentanil/propofol at a proportion of 2/1,000 or 3/1,000 (remifentanil concentration, 20 or 30 µg/ml in 1% propofol in Group II or Group III, respectively). The extubation time (the primary outcome of the study), the orientation time and number of patients in whom intraoperative hypotension, hypertension or bradycardia episodes were encountered during anesthesia were comparable among the groups. The mean remifentanil infusion rate in Group III was significantly higher than that in the other groups. The mean propofol infusion rates and mean bispectral index (BIS) scores during anesthesia were comparable among groups. Hypotension accompanied with a high BIS was encountered in one patient in Group III. In conclusion, compared to the standard TIVA technique using separate drug infusions, MIXTIVA infusion used for thyroidectomies did not result in any statistically significant difference in recovery and clinical outcomes. This technique may be considered as a practical implementation for busy ambulatory centers performing general anesthesia. The present study was retrospectively registered at clinicaltrials.gov (trial registration no. NCT04394897).


  • Open Access

    Effects of pressure-controlled and volume-controlled ventilation on respiratory mechanics and systemic stress response during prone position

    by Oznur Sen, Mefkur Bakan, Tarik Umutoglu, Nurdan Aydın, Mehmet Toptas, Ibrahim Akkoc

    Prone position during general anesthesia for special surgical operations may be related with increased airway pressure, decreased pulmonary and thoracic compliance that may be explained by restriction of chest expansion and compression of abdomen. The optimum ventilation mode for anesthetized patients on prone position was not described and studies comparing volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) during prone position are limited. We hypothesized that PCV instead of VCV during prone position could achieve lower airway pressures and reduce the systemic stress response. In this study, we aimed to compare the effects of PCV and VCV modes during prone position on respiratory mechanics, oxygenation, and hemodynamics, as well as blood cortisol and insulin levels, which has not been investigated before. Fifty-four ASA I-II patients, 18–70 years of age, who underwent percutaneous nephrolithotomy on prone position, were randomly selected to receive either the PCV (Group PC, n = 27) or VCV (Group VC, n = 27) under general anesthesia with sevoflurane and fentanyl. Blood sampling was made for baseline arterial blood gases (ABG), cortisol, insulin, and glucose levels. After anesthesia induction and endotracheal intubation, patients in Group PC were given pressure support to form 8 mL/kg tidal volume and patients in Group VC was maintained at 8 mL/kg tidal volume calculated using predicted body weight. All patients were maintained with 5 cmH2O PEEP. Respiratory parameters were recorded during supine and prone position. Assessment of ABG and sampling for cortisol, insulin and glucose levels were repeated during surgery and 60 min after extubation. P-peak and P-plateau levels during supine and prone positions were significantly higher and P-mean and compliance levels during prone position were significantly lower in Group VC when compared with Group PC. Postoperative PaO2 level was significantly higher in Group PC compared with Group VC. Cortisol levels were increased with surgery in both groups (p < 0.05) and decreased to baseline levels in Group PC while remained high in Group VC in the early postoperative period. Cortisol levels were significantly higher in Group VC during surgery and in the early postoperative period compared with Group PC. When compared with VCV mode, PCV mode is associated with lower P-peak and P-plateau levels during both supine and prone positions, better oxygenation postoperatively, lower blood cortisol levels during surgery in prone position and in the early postoperative period. We concluded that PCV mode might be more appropriate in prone position during anesthesia.


  • Open Access

    Evaluation of sciatic nerve damage following intraneural injection of bupivacaine, levobupivacaine and lidocaine in rats

    by Oznur Sen, Nevzat Cem Sayilgan, Ayse Cigdem Tutuncu, Mefkur Bakan, Guniz Meyanci Koksal, Huseyin Oz


  • Comparison of EtView™ tracheoscopic ventilation tube and video-assisted fiberoptic bronchoscopy during percutaneous dilatational tracheostomy

    by Tarik Umutoglu, Mefkur Bakan, Ufuk Topuz, Sinan Yilmaz, Kadir Idin, Selcuk Alver, Erdogan Ozturk, Ziya Salihoglu

    Fiberoptic bronchoscopy (FOB) via endotracheal tube (ETT) is the most frequent utilized technique for monitoring of percutaneous dilatational tracheostomy (PDT) procedure while maintaining mechanical ventilation. Endoscopic guidance has increased the safety of this procedure; nevertheless, the use of a bronchoscope via ETT potentially may deteriorate ventilation and lead to hypercarbia and/or hypoxia. EtView tracheoscopic ventilation tube (EtView TVT) is a standard endotracheal tube with a camera and light source embedded at the tip. The objectives of this study are to introduce EtView TVT as a monitoring tool during PDT and to compare it with video assisted FOB via ETT. We hypothesized that using EtView TVT during PDT may obtain similar visualization; also may have advantages regarding better mechanical ventilation conditions when compared with video-assisted FOB via ETT. Patients, 18–75 years of age requiring mechanical ventilation scheduled for PDT were randomly allocated into two groups for airway monitorization to guide PDT procedure either with FOB via ETT (Group FOB, n = 12) or EtView TVT (Group EtView, n = 12). After standard anesthesia protocol, alveolar recruitment maneuver was applied and all patients were mechanically ventilated at pressure-controlled ventilation mode with same pressure levels. The primary outcome variable was the reduction in arterial oxygen partial pressure (PaO2) values during the procedure. Other respiratory variables and the effectiveness (the visualization and identification of relevant airway structures) of two techniques were the secondary outcome variables. Patients in both groups were comparable with respect to demographic characteristics and initial respiratory variables. Visualization and identification of relevant airway structures in any steps of the PDT procedure were also comparable. The decrease in minute ventilation in Group FOB was higher when compared with Group EtView (51 ± 4 % vs. 12 ± 7.3 %, p < 0.05). The decrease in PaO2 from initial levels during (34 ± 21 % vs. 5 ± 7 % decrease) and after (26 ± 27 % vs. 2.8 ± 16 % decrease) the procedure was higher in Group FOB when compared with Group EtView (p < 0.05). Considering comparable features in monitorization and advantageous features over mechanical ventilation when compared with video bronchoscopy; EtView TVT would be a good alternative for airway monitorization during PDT especially for patients with poor pulmonary reserve.


  • Open Access

    Effects of pressure-controlled and volume-controlled ventilation on respiratory mechanics and systemic stress response during laparoscopic cholecystectomy

    by Oznur Sen, Tarik Umutoglu, Nurdan Aydın, Mehmet Toptas, Ayse Cigdem Tutuncu, Mefkur Bakan

    Pressure-controlled ventilation (PCV) is less frequently employed in general anesthesia. With its high and decelerating inspiratory flow, PCV has faster tidal volume delivery and different gas distribution. The same tidal volume setting, delivered by PCV versus volume-controlled ventilation (VCV), will result in a lower peak airway pressure and reduced risk of barotrauma. We hypothesized that PCV instead of VCV during laparoscopic surgery could achieve lower airway pressures and reduce the systemic stress response. Forty ASA I-II patients were randomly selected to receive either the PCV (Group PC, n = 20) or VCV (Group VC, n = 20) during laparoscopic cholecystectomy. Blood sampling was made for baseline arterial blood gases (ABG), cortisol, insulin, and glucose levels. General anesthesia with sevoflurane and fentanyl was employed to all patients. After anesthesia induction and endotracheal intubation, patients in Group PC were given pressure support to form 8 mL/kg tidal volume and patients in Group VC was maintained at 8 mL/kg tidal volume calculated using predicted body weight. All patients were maintained with 5 cmH2O positive-end expiratory pressure (PEEP). Respiratory parameters were recorded before and 30 min after pneumoperitonium. Assessment of ABG and sampling for cortisol, insulin and glucose levels were repeated 30 min after pneumoperitonium and 60 min after extubation. The P-peak levels observed before (18.9 ± 3.8 versus 15 ± 2.2 cmH2O) and during (23.3 ± 3.8 versus 20.1 ± 2.9 cmH2O) pneumoperitoneum in Group VC were significantly higher. Postoperative partial arterial oxygen pressure (PaO2) values are higher (98 ± 12 versus 86 ± 11 mmHg) in Group PC. Arterial carbon dioxide pressure (PaCO2) values (41.8 ± 5.4 versus 36.7 ± 3.5 mmHg) during pneumoperitonium and post-operative mean cortisol and insulin levels were higher in Group VC. When compared to VCV mode, PCV mode may improve compliance during pneumoperitoneum, improve oxygenation and reduce stress response postoperatively and may be more appropriate in patients having laparoscopic surgery.


  • Open Access

    Comparison of SpO2 values from different fingers of the hands

    by Gokcen Basaranoglu, Mefkur Bakan, Tarik Umutoglu, Seniyye Ulgen Zengin, Kadir Idin, Ziya Salihoglu

    Pulse oximetry is a frequently used tool in anesthesia practice. Gives valuable information about arterial oxygen content, tissue perfusion and heart beat rate. In this study we aimed to provide the comparison of peripheral capillary hemoglobin oxygen saturation (SpO2) values among every finger of the two hands. Thirty-seven healthy volunteers from operative room stuffs between the ages of 18–30 years were enrolled in the study. They were monitored after 5 min of rest. After their non invasive blood pressure, heart rate, fasting time and body temperature were measured, SpO2 values were obtained from every finger and each of two hands fingers with the same pulse oximetry. All the SpO2 values were obtained after at least 1 min of measurement period. A total of 370 SpO2 measurements from 37 volunteers were obtained. The highest average SpO2 value was measured from right middle finger (98.2 % ± 1.2) and it was statistically significant when compared with right little finger and left middle finger. The second highest average SpO2 value was measured from right thumb and it was statistically significant only when compared with left middle finger (the finger with the lowest average SpO2 value) (p < 0.05). SpO2 measurement from the fingers of the both hands with the pulse oximetry, the right middle finger and right thumb have statistically significant higher value when compared with left middle finger in right-hand dominant volunteers. We assume that right middle finger and right thumb have the most accurate value that reflects the arterial oxygen saturation.


  • Open Access

    A influência das manobras de suporte das vias aéreas sobre a visibilidade da glote em fibrobroncoscopia pediátrica

    by Tarik Umutoglu, Ahmet Hakan Gedik, Mefkur Bakan, Ufuk Topuz, Hayrettin Daskaya, Erdogan Ozturk, Erkan Cakir, Ziya Salihoglu


  • Open Access

    The influence of airway supporting maneuvers on glottis view in pediatric fiberoptic bronchoscopy

    by Tarik Umutoglu, Ahmet Hakan Gedik, Mefkur Bakan, Ufuk Topuz, Hayrettin Daskaya, Erdogan Ozturk, Erkan Cakir, Ziya Salihoglu