C.L. Lubbers
Research Subjects
C.L. Lubbers has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- François Clemens
Delft University of Technology, Faculty of Civil Engineering and Geosciences, Section of Sanitary Engineering, P.O. Box 5048, 2600 GA Delft, The Netherlands
3 shared publications
Latest Publications
- 1 February 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 55 (4) , 31-38
Detection of gas pockets in pressurised wastewater mains using dynamic system response analysis
In the Netherlands, wastewater is mostly collected in combined sewer system and transported to a WWTP through pressure mains. These pressure mains form an element of the system that did not receive much attention lately with respect to monitoring of performance and maintenance. For that reason, their state of functioning is often not known. Failure of operation is only noticed when during storm conditions the capacity of the system drops, resulting in undesirable discharge to the surface water. A recently made inventory showed that about half of the pressure mains show increased pressure loss for no obvious reason. Reduction of the systems nominal capacity can result from many causes, like increased wall roughness, scaling and the occurrence of free gas in the pipeline. The occurrence of gas-pockets may be caused by degassing of dissolved gas, but also by air entrapment at the pump inlet or at air valves. A research project is started that will be carried out from 2003 to 2005. This project focuses on three goals: This paper describes the layout of the experimental set-up to detect and diagnose gas problems and the first results of the experiments are presented and discussed. The results are used to validate a model (Wanda) developed by Delft Hydraulics that describes the phenomena involved in surges in air/water transport.
- 1 February 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 55 (4) , 31-38
Detection of gas pockets in pressurised wastewater mains using dynamic system response analysis
In the Netherlands, wastewater is mostly collected in combined sewer system and transported to a WWTP through pressure mains. These pressure mains form an element of the system that did not receive much attention lately with respect to monitoring of performance and maintenance. For that reason, their state of functioning is often not known. Failure of operation is only noticed when during storm conditions the capacity of the system drops, resulting in undesirable discharge to the surface water. A recently made inventory showed that about half of the pressure mains show increased pressure loss for no obvious reason. Reduction of the systems nominal capacity can result from many causes, like increased wall roughness, scaling and the occurrence of free gas in the pipeline. The occurrence of gas-pockets may be caused by degassing of dissolved gas, but also by air entrapment at the pump inlet or at air valves. A research project is started that will be carried out from 2003 to 2005. This project focuses on three goals: This paper describes the layout of the experimental set-up to detect and diagnose gas problems and the first results of the experiments are presented and discussed. The results are used to validate a model (Wanda) developed by Delft Hydraulics that describes the phenomena involved in surges in air/water transport.
- 1 December 2006
- Published by IWA Publishing in Water Science & Technology
- Vol. 54 (11-12) , 233-240
Breakdown of air pockets in downwardly inclined sewerage pressure mains
In the Netherlands, wastewater is collected in municipal areas and transported to centralised WWTPs by an extensive system of pressure mains. Over the last decades these pressure mains did not receive much attention in terms of monitoring of performance or maintenance. A recent inventory showed that half of the pressure mains show an increased pressure loss for no directly obvious reason. One of the many causes that account for the reduction of the flow capacity is the occurrence of free gas in the pipeline. During dry weather periods with low flow velocities, gas may accumulate at high points in the system. Once the velocity increases during storm weather flow, the air pockets may be broken down and transported to the end of the system. A research study is started focussing on the description of the gas-water phenomena in wastewater pressure mains with respect to transportation of gas. An experimental facility is constructed for the study of multi-phase flow. This paper describes the preliminary results of experiments on breakdown rates of gas pockets as a function of inclination angle and water flow rate. The results show an increasing breakdown rate with increasing inclination angle.
- 1 December 2006
- Published by IWA Publishing in Water Science & Technology
- Vol. 54 (11-12) , 233-240
Breakdown of air pockets in downwardly inclined sewerage pressure mains
In the Netherlands, wastewater is collected in municipal areas and transported to centralised WWTPs by an extensive system of pressure mains. Over the last decades these pressure mains did not receive much attention in terms of monitoring of performance or maintenance. A recent inventory showed that half of the pressure mains show an increased pressure loss for no directly obvious reason. One of the many causes that account for the reduction of the flow capacity is the occurrence of free gas in the pipeline. During dry weather periods with low flow velocities, gas may accumulate at high points in the system. Once the velocity increases during storm weather flow, the air pockets may be broken down and transported to the end of the system. A research study is started focussing on the description of the gas-water phenomena in wastewater pressure mains with respect to transportation of gas. An experimental facility is constructed for the study of multi-phase flow. This paper describes the preliminary results of experiments on breakdown rates of gas pockets as a function of inclination angle and water flow rate. The results show an increasing breakdown rate with increasing inclination angle.
- 1 August 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 52 (3) , 37-44
Air and gas pockets in sewerage pressure mains
In The Netherlands, wastewater is collected in municipal areas and transported to large centralised WWTPs by means of an extensive system of pressure mains. Over the past decades these pressure mains did not receive much attention in terms of monitoring of performance or maintenance. For that reason, in practice their state of functioning is often not known. Failure of operation is only noticed when the capacity of the system proves to be insufficient to fulfil the minimum design capacity demand. A recent inventory showed that half of the pressure mains show an increased pressure loss for no directly obvious reason. Many causes may account for the reduction of the system's nominal capacity like an increased wall roughness, scaling or occurrence of free gas in the pipeline. The occurrence of free gas may be caused by degassing of dissolved (bio) gas or by air entrained at the pumps' inlet or at air valves. A research study is started that will focus on three main issues:
- 1 August 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 52 (3) , 37-44
Air and gas pockets in sewerage pressure mains
In The Netherlands, wastewater is collected in municipal areas and transported to large centralised WWTPs by means of an extensive system of pressure mains. Over the past decades these pressure mains did not receive much attention in terms of monitoring of performance or maintenance. For that reason, in practice their state of functioning is often not known. Failure of operation is only noticed when the capacity of the system proves to be insufficient to fulfil the minimum design capacity demand. A recent inventory showed that half of the pressure mains show an increased pressure loss for no directly obvious reason. Many causes may account for the reduction of the system's nominal capacity like an increased wall roughness, scaling or occurrence of free gas in the pipeline. The occurrence of free gas may be caused by degassing of dissolved (bio) gas or by air entrained at the pumps' inlet or at air valves. A research study is started that will focus on three main issues: