David Q. Liu
Research Subjects
David Q. Liu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Ray Bakhtiar
Department of Drug Metabolism, Merck Research Laboratories, Rahway, NJ 07065, USA
2 shared publicationsYuan‐Qing Xia
Department of Drug Metabolism, Merck Research Laboratories, Rahway, NJ 07065, USA
2 shared publicationsAnn Mao
Department of Drug Metabolism, Merck Research Laboratories, RY80L‐109, P.O. Box 2000, Rahway, NJ 07065, USA
1 shared publicationCornelis E.C.A. Hop
Department of Drug Metabolism, Merck Research Laboratories, RY80L‐109, P.O. Box 2000, Rahway, NJ 07065, USA
1 shared publicationJeffrey D. Miller
LC/MS Product Applications Lab., Applied Biosystems, Framingham, MA 01701, USA
1 shared publicationMaría G. Beconi
Department of Drug Metabolism, Merck Research Laboratories, RY80L‐109, P.O. Box 2000, Rahway, NJ 07065, USA
1 shared publication
Latest Publications
- 29 October 2003
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 38 (11) , 1210-1212
Collision‐induced fluorine atom migration in atmospheric pressure ionization mass spectrometry
- 29 October 2003
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 38 (11) , 1210-1212
Collision‐induced fluorine atom migration in atmospheric pressure ionization mass spectrometry
- Open Access
- 16 April 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (11) , 1137-1145
Use of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis
A new type of quadrupole linear ion trap mass spectrometer, Q TRAP™ LC/MS/MS system (Q TRAP™), was evaluated for its performance in two studies: firstly, the in vitro metabolism of gemfibrozil in human liver microsomes, and, secondly, the quantification of propranolol in rat plasma. With the built‐in information‐dependent‐acquisition (IDA) software, the instrument utilizes full scan MS in the ion trap mode and/or constant neutral loss scans as survey scans to trigger product ion scan (MS 2 ) and MS 3 experiments to obtain structural information of drug metabolites ‘on‐the‐fly’. Using this approach, five metabolites of gemfibrozil were detected in a single injection. This instrument combines some of the unique features of a triple quadrupole mass spectrometer, such as constant neutral loss scan, precursor ion scan and multiple reaction monitoring (MRM), together with the capability of a three‐dimensional ion trap. Therefore, it becomes a powerful instrument for metabolite identification. The fast duty cycle in the ion trap mode allows the use of full product ion scan for quantification. For the quantification of propranolol, both MRM mode and full product ion scan in the ion trap mode were employed. Similar sensitivity, reproducibility and linearity values were established using these two approaches. The use of the product ion scan mode for quantification provided a convenient tool in selecting transitions for improving selectivity during the method development stage. Copyright © 2003 John Wiley & Sons, Ltd.
- 16 April 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (11) , 1137-1145
Open AccessUse of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis
A new type of quadrupole linear ion trap mass spectrometer, Q TRAP™ LC/MS/MS system (Q TRAP™), was evaluated for its performance in two studies: firstly, the in vitro metabolism of gemfibrozil in human liver microsomes, and, secondly, the quantification of propranolol in rat plasma. With the built‐in information‐dependent‐acquisition (IDA) software, the instrument utilizes full scan MS in the ion trap mode and/or constant neutral loss scans as survey scans to trigger product ion scan (MS 2 ) and MS 3 experiments to obtain structural information of drug metabolites ‘on‐the‐fly’. Using this approach, five metabolites of gemfibrozil were detected in a single injection. This instrument combines some of the unique features of a triple quadrupole mass spectrometer, such as constant neutral loss scan, precursor ion scan and multiple reaction monitoring (MRM), together with the capability of a three‐dimensional ion trap. Therefore, it becomes a powerful instrument for metabolite identification. The fast duty cycle in the ion trap mode allows the use of full product ion scan for quantification. For the quantification of propranolol, both MRM mode and full product ion scan in the ion trap mode were employed. Similar sensitivity, reproducibility and linearity values were established using these two approaches. The use of the product ion scan mode for quantification provided a convenient tool in selecting transitions for improving selectivity during the method development stage. Copyright © 2003 John Wiley & Sons, Ltd.
- 7 June 2002
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (13) , 1330-1336
Use of a liquid chromatography/ion trap mass spectrometry/triple quadrupole mass spectrometry system for metabolite identification
- 7 June 2002
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (13) , 1330-1336
Use of a liquid chromatography/ion trap mass spectrometry/triple quadrupole mass spectrometry system for metabolite identification
- 19 December 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (2) , 142-146
Interference of a carbamoyl glucuronide metabolite in quantitative liquid chromatography/tandem mass spectrometry
- 19 December 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (2) , 142-146
Interference of a carbamoyl glucuronide metabolite in quantitative liquid chromatography/tandem mass spectrometry
- 4 September 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (19) , 1832-1839
Use of on‐line hydrogen/deuterium exchange to facilitate metabolite identification
An Erratum for this article has been published in Rapid Communications in Mass Spectrometry 17(3) 2003, 264 Biotransformation studies performed on an investigational compound (I, represented by R1‐CH(NH 2 )‐CO‐N(R2)‐CH 2 ‐S‐R3) led to the identification of five metabolites (M1–M5). Based on LC/MS (liquid chromatography/mass spectrometry) analysis which included the use of H 2 O and D 2 O in the mobile phases, they were identified as the sulfoxide (M1), sulfone (M2), carbamoyl glucuronide (M3), N‐glucuronide (M4), and N‐glucoside (M5) metabolites, respectively. The structure of M3, a less commonly seen carbamoyl glucuronide metabolite, was established using on‐line H/D (hydrogen/deuterium) exchange experiments conducted by LC/MS. H/D exchange experiments were also used to distinguish the S‐oxidation structures of M1 and M2 from hydroxylation. Herein, the application of deuterium oxide as the LC/MS mobile phase for structural elucidation of drug metabolites in biological matrices is demonstrated. Copyright © 2001 John Wiley & Sons, Ltd.
- 4 September 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (19) , 1832-1839
Use of on‐line hydrogen/deuterium exchange to facilitate metabolite identification
An Erratum for this article has been published in Rapid Communications in Mass Spectrometry 17(3) 2003, 264 Biotransformation studies performed on an investigational compound (I, represented by R1‐CH(NH 2 )‐CO‐N(R2)‐CH 2 ‐S‐R3) led to the identification of five metabolites (M1–M5). Based on LC/MS (liquid chromatography/mass spectrometry) analysis which included the use of H 2 O and D 2 O in the mobile phases, they were identified as the sulfoxide (M1), sulfone (M2), carbamoyl glucuronide (M3), N‐glucuronide (M4), and N‐glucoside (M5) metabolites, respectively. The structure of M3, a less commonly seen carbamoyl glucuronide metabolite, was established using on‐line H/D (hydrogen/deuterium) exchange experiments conducted by LC/MS. H/D exchange experiments were also used to distinguish the S‐oxidation structures of M1 and M2 from hydroxylation. Herein, the application of deuterium oxide as the LC/MS mobile phase for structural elucidation of drug metabolites in biological matrices is demonstrated. Copyright © 2001 John Wiley & Sons, Ltd.