Roy Crowninshield
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Roy Crowninshield has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Douglas H Wentz
From *Zimmer, Inc., PO Box 708, Warsaw, IN; and the †Washington University School of Medicine, St. Louis, MO
3 shared publicationsWilliam J Maloney
From *Zimmer, Inc., PO Box 708, Warsaw, IN; and the †Washington University School of Medicine, St. Louis, MO
3 shared publicationsCheryl R Blanchard
From *Zimmer, Inc., PO Box 708, Warsaw, IN; and the †Washington University School of Medicine, St. Louis, MO
2 shared publicationsSteve M Humphrey
From *Zimmer, Inc., PO Box 708, Warsaw, IN; and the †Washington University School of Medicine, St. Louis, MO
2 shared publicationsDanny L Levine
1 shared publication
Latest Publications
- 1 December 2004
- No. 429,p. 102-7
Biomechanics of large femoral heads: what they do and don't do.
The stability and durability of total hip reconstruction is dependent on many factors that include the design and anatomic orientation of prosthetic components. An analysis of femoral component head size and acetabular component orientation shows an interdependency of these variables and joint stability. Increased femoral component head size can increase hip stability by increasing the prosthetic impingement-free range of hip motion and by increasing the inferior head displacement required before hip dislocation. Increasing the femoral head size from 22 mm to 40 mm increases the required displacement for dislocation by about 5 mm with the acetabular component at 45 degrees of abduction; however, increasing acetabular component abduction greatly diminishes this stability advantage of larger femoral heads. Vertical acetabular component orientation and femoral component head subluxation are each predicted to more than double the tensile stress with acetabular component polyethylene compared with components at 45 degrees of abduction. With a desirable acetabular component orientation, the use of larger femoral heads may result in improved joint stability and durable use of polyethylene. With high abduction acetabular component orientation, the use of larger femoral heads contributes little to joint stability and contributes to elevated stress within the polyethylene that may result in implant failure.
- 1 December 2004
- No. 429,p. 102-7
Biomechanics of large femoral heads: what they do and don't do.
The stability and durability of total hip reconstruction is dependent on many factors that include the design and anatomic orientation of prosthetic components. An analysis of femoral component head size and acetabular component orientation shows an interdependency of these variables and joint stability. Increased femoral component head size can increase hip stability by increasing the prosthetic impingement-free range of hip motion and by increasing the inferior head displacement required before hip dislocation. Increasing the femoral head size from 22 mm to 40 mm increases the required displacement for dislocation by about 5 mm with the acetabular component at 45 degrees of abduction; however, increasing acetabular component abduction greatly diminishes this stability advantage of larger femoral heads. Vertical acetabular component orientation and femoral component head subluxation are each predicted to more than double the tensile stress with acetabular component polyethylene compared with components at 45 degrees of abduction. With a desirable acetabular component orientation, the use of larger femoral heads may result in improved joint stability and durable use of polyethylene. With high abduction acetabular component orientation, the use of larger femoral heads contributes little to joint stability and contributes to elevated stress within the polyethylene that may result in implant failure.
- 1 December 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 429, 102-107
Biomechanics of Large Femoral Heads
The stability and durability of total hip reconstruction is dependent on many factors that include the design and anatomic orientation of prosthetic components. An analysis of femoral component head size and acetabular component orientation shows an interdependency of these variables and joint stability. Increased femoral component head size can increase hip stability by increasing the prosthetic impingement-free range of hip motion and by increasing the inferior head displacement required before hip dislocation. Increasing the femoral head size from 22 mm to 40 mm increases the required displacement for dislocation by about 5 mm with the acetabular component at 45° of abduction; however, increasing acetabular component abduction greatly diminishes this stability advantage of larger femoral heads. Vertical acetabular component orientation and femoral component head subluxation are each predicted to more than double the tensile stress with acetabular component polyethylene compared with components at 45° of abduction. With a desirable acetabular component orientation, the use of larger femoral heads may result in improved joint stability and durable use of polyethylene. With high abduction acetabular component orientation, the use of larger femoral heads contributes little to joint stability and contributes to elevated stress within the polyethylene that may result in implant failure.
- 1 December 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 429, 102-107
Biomechanics of Large Femoral Heads
The stability and durability of total hip reconstruction is dependent on many factors that include the design and anatomic orientation of prosthetic components. An analysis of femoral component head size and acetabular component orientation shows an interdependency of these variables and joint stability. Increased femoral component head size can increase hip stability by increasing the prosthetic impingement-free range of hip motion and by increasing the inferior head displacement required before hip dislocation. Increasing the femoral head size from 22 mm to 40 mm increases the required displacement for dislocation by about 5 mm with the acetabular component at 45° of abduction; however, increasing acetabular component abduction greatly diminishes this stability advantage of larger femoral heads. Vertical acetabular component orientation and femoral component head subluxation are each predicted to more than double the tensile stress with acetabular component polyethylene compared with components at 45° of abduction. With a desirable acetabular component orientation, the use of larger femoral heads may result in improved joint stability and durable use of polyethylene. With high abduction acetabular component orientation, the use of larger femoral heads contributes little to joint stability and contributes to elevated stress within the polyethylene that may result in implant failure.
- 1 March 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 420 (420) , 176-180
The Role of Proximal Femoral Support in Stress Development Within Hip Prostheses
Bone remodeling commonly associated with implant loosening may require revision total hip replacement when there is substantial proximal femoral bone loss. Additionally, the surgical exposure required to remove primary implants may alter the proximal femur’s structure. As a result, in many revision hip situations the proximal femur provides compromised support for the revision femoral component. Stress analyses of the proximal femur with extensively porous-coated prosthetic femoral components show that proximomedial femoral bone loss, ununited femoral osteotomy, and periprosthetic fracture can result in significant elevation of stress within revision prosthetic components. The first principal stress within prosthetic components can, in proximal bone loss conditions, be elevated significantly above a revision prostheses’ fatigue strength. Loss of proximomedial bone is predicted to increase stress within a revision component by as much as 82%. An unhealed transverse femoral fracture or osteotomy is predicted to more than double the stress within a revision femoral component. In revision total hip replacement, efforts directed toward the restoration of proximal femoral bone and the use of larger prostheses may contribute to avoiding prostheses fatigue fracture. Similarly, protected weightbearing in patients with ununited femoral osteotomies and periprosthetic fractures may be important to preventing prosthetic fracture.
- 1 March 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 420 (420) , 176-180
The Role of Proximal Femoral Support in Stress Development Within Hip Prostheses
Bone remodeling commonly associated with implant loosening may require revision total hip replacement when there is substantial proximal femoral bone loss. Additionally, the surgical exposure required to remove primary implants may alter the proximal femur’s structure. As a result, in many revision hip situations the proximal femur provides compromised support for the revision femoral component. Stress analyses of the proximal femur with extensively porous-coated prosthetic femoral components show that proximomedial femoral bone loss, ununited femoral osteotomy, and periprosthetic fracture can result in significant elevation of stress within revision prosthetic components. The first principal stress within prosthetic components can, in proximal bone loss conditions, be elevated significantly above a revision prostheses’ fatigue strength. Loss of proximomedial bone is predicted to increase stress within a revision component by as much as 82%. An unhealed transverse femoral fracture or osteotomy is predicted to more than double the stress within a revision femoral component. In revision total hip replacement, efforts directed toward the restoration of proximal femoral bone and the use of larger prostheses may contribute to avoiding prostheses fatigue fracture. Similarly, protected weightbearing in patients with ununited femoral osteotomies and periprosthetic fractures may be important to preventing prosthetic fracture.
- 1 July 2003
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 412 (412) , 8-13
The Orthopaedic Profession and Industry
Many improvements in orthopaedic care have been enabled by the relationship that exists between the orthopaedic profession and the orthopaedic industry. This relationship is multifactorial and includes new technology development, medical education, orthopaedic research, and patient education. Acting individually and collectively, the profession and the industry advance their standing by focusing on improved patient care. Although the industry, the profession, and the patient have many shared interests, they also may have real or potential conflicts of interests. The patient’s interest in the quality of treatment outcome is shared by the profession and industry. However, the interests of the profession may include issues related to the success of their practices, management of their time, and advancement of their skills. Industry’s interests, in turn, include the support of their customers and the success of their businesses. Conflicts of interest between these parties are potentially neither avoidable nor undesirable. Managed well, the relationship of the orthopaedic profession and the industry achieves the goals of each while advancing patient care. As the profession and the industry each experience change, continued attention should be directed to ensuring that the interest of each is advanced only in the context of serving the interest of the patient with musculoskeletal disorders.
- 1 July 2003
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 412 (412) , 8-13
The Orthopaedic Profession and Industry
Many improvements in orthopaedic care have been enabled by the relationship that exists between the orthopaedic profession and the orthopaedic industry. This relationship is multifactorial and includes new technology development, medical education, orthopaedic research, and patient education. Acting individually and collectively, the profession and the industry advance their standing by focusing on improved patient care. Although the industry, the profession, and the patient have many shared interests, they also may have real or potential conflicts of interests. The patient’s interest in the quality of treatment outcome is shared by the profession and industry. However, the interests of the profession may include issues related to the success of their practices, management of their time, and advancement of their skills. Industry’s interests, in turn, include the support of their customers and the success of their businesses. Conflicts of interest between these parties are potentially neither avoidable nor undesirable. Managed well, the relationship of the orthopaedic profession and the industry achieves the goals of each while advancing patient care. As the profession and the industry each experience change, continued attention should be directed to ensuring that the interest of each is advanced only in the context of serving the interest of the patient with musculoskeletal disorders.