KCKenneth A. Cunefare

Kenneth A. Cunefare

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kenneth A. Cunefare has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • From Berlin to Atlanta, with a sojurn in Oz

    by Kenneth Cunefare

    Having been lured away from Exxon to pursue a Ph.D. by Gary Koopmann, I had no idea during a 1989 visit to the TU in Berlin, with the Berlin Wall still a looming presence, that he was laying the ground work with Herr Dr. Prof. Manfred Heckl of the Institute of Technical Acoustics to host me should I receive the Hunt. When I arrived in July 1990, the wall had fallen, and great changes were underway. The year passed all too quickly, with Pink Floyd at “The Wall,” technical visits to Dresden, Gottingen, and ISVR, and more. The work I did in that year remains some of my highest cited work. Having already accepted a faculty position at Georgia Tech made the year much less stressful. The connections and colleagues I made at the TU remained throughout my career. At GT I explored a number of areas triggered by my Hunt year, including structural acoustic optimization, acoustic mode representation for exterior fields, and active structural acoustic control which led to a sabbatical year, with results akin to my Hunt year, at the University of Adelaide in Australia. I am also a founding member of a successful acoustic consultancy (Arpeggio).

  • Noise suppressors with engineered compliance in fluid hydraulic systems

    by Kenneth Cunefare, Elliott Gruber, Nathaniel Pedigo

    Fluid power hydraulic systems, common on a wide variety of industrial and construction equipment, frequently exhibit undesirable noise characteristics. The noise is primarily due to the pump-induced pressure pulsation in the fluid. One means to control this fluid-borne noise is through the use of a suppressor integrating compliance, as may be introduced using a pressurized bladder, or an elastic compliant liner exposed to the fluid. This compliance causes an impedance change at the inlet to the suppressor. Within the suppressor, the compliance leads to a reduced sound speed, which may then lead to fluid particle velocities high enough for damping to become effective. Classical dissipative noise control means, as is common in air or gas mufflers, is otherwise ineffective in fluid systems because of the low particle velocity. An engineered solid material, a syntactic foam, is under development for use in hydraulic systems. The syntactic foam of interest is comprised of microspheres dispersed in a polymer. Particular challenges include retaining functionality at high system pressures, which may be addressed by pressurizing the microspheres. The foam’s performance increases with volume fraction of microspheres, and internal pressurization. The material is enabling of a other fluid noise control devices, including water hammer arrestors.

  • What’s that sound? Probe tones and poltergeists: Two case studies in diagnosing noise sources

    by Kenneth A. Cunefare

    Case #1: Following construction of a new hospital building within a larger campus, residents began to complain about droning noises in the surrounding neighborhood. Blame was laid on HVAC chillers and an MRI chiller installed on exposed roof-tops of the building. However, there were numerous other chillers on buildings on the campus that were not blamed; a test using probe tones eliminated the hospital building as the source impacting the community. Case #2: A homeowner complained of intermittent groaning and moaning noises in the home (poltergeist-like). Interviews revealed that the noises occurred essentially randomly; while the homeowner correlated occurrences to whether or not it had recently rained, the correlation was weak. Additionally, the homeowner had found that opening a water tap would cause the sound to fade away; this was suggestive, but since the sound faded away in a short time even without opening the valve, it was not definitive. Complicating the diagnosis was the intermittency of the noise (weeks could pass between events), and its short duration. A faulty GFI threw a red-herring into the mix, but ultimately the problem was solved by replacing the household water pressure regulator.

  • Removable damping treatments for use in sheet metal fabrication

    by Kenneth A. Cunefare

    Many industrial fabrication processes on metallic structures generate a great deal of work place noise. For example, riveting and chiseling on light-weight, stiff aerospace structures such as fusalage components and flight surfaces subject the workpiece to repeated impacts and consequent noise generation. Many such structures may be lightly damped. Many damping treatments are targeted toward permanent installation on a structure, but if the treatments are considered to be removable, one has design freedoms including placement on a structure, as well as mass and damping means, that might not otherwise exist if the treatment had to remain in place. A shot-mass or particle-impact damper configured in an elastic, cellular array is shown to provide high loss factors and mass loading, which, along with ease of placement and removal, may provide significant reduction in component vibration during fabrication and consequent reduction in noise in the work place. The concept applied to an example aircraft panel when subjected to riveting operations yields more than 10 dB of noise reduction.

  • Optimization of Single and Dual Suppressors Under Varying Load and Pressure Conditions

    by Elliott R. Gruber, Kenneth A. Cunefare, Per W. Danzl, Kenneth A. Marek, Michel A. Beyer

    Hydraulic systems that operate over a broad range of load pressures pose challenges for suppression of fluid-borne noise. A common type of noise control device, a bladder-style suppressor, performs well only over a relatively narrow range of load or system pressures. This paper considers the problem of finding the optimal charge pressure(s) in either a single suppressor or two suppressors in series for maximum fluid-borne noise suppression in a weighted sense. The transmission loss, a measure of pressure ripple (dynamic pressure fluctuation) reduction, for the suppressors is predicted by an equivalent fluid model. The optimum configuration is sought through maximization of an objective function. The objective function is a summation of weighted transmission losses, where the weighting captures the duty cycle of the load pressure through a time weighting factor, and frequency weighting factor captures the spectral content of the pressure ripple. The duty-cycle weighting biases the objective function toward the most-used pressures. The frequency weighting emphasizes the high-energy spectral components in the target pressure ripple at a given load or system pressure. Optimal configurations are found for a set of system pressures, load pressures and duty cycles. It is found that the time weighting has a more significant impact on the optimum charge pressure than the frequency weighting, as seen by duty cycles considered in this paper.


  • Linear Multimodal Model for a Pressurized Gas Bladder Style Hydraulic Noise Suppressor

    by Kenneth A. Marek, Elliott R. Gruber, Kenneth A. Cunefare

    Pressurized bladder style in-line hydraulic noise suppressors are commonly used in industry for broadband pressure ripple reduction, but predictive models for these suppressors are not available in the literature. To address this shortcoming, a linear acoustic model is developed for a commercially available suppressor, in which the acoustic field is analyzed through expansion into multiple radial modes. Bladder mass, perforate layer impedance, and inlet/outlet extensions are included in the model, and transmission loss predictions are validated against experimental data. The presented theoretical model has been shown to correspond well to experimental data at frequencies below about 1300 to 2300 Hz, depending on system and precharge pressures. In addition, simulations show that small variations in bladder precharge temperature or rubber bladder mass do not significantly affect transmission loss. While inclusion of the perforate layer significantly affects modeling results, it is observed that better perforate layer models or experimental data are needed for accurate system modeling.


  • Numerical model for a hydraulic in-line silencer.

    by Kenneth A. Marek, Nicholas E. Earnhart, Kenneth A. Cunefare

  • Evaluation of hydraulic silencers.

    by Nicholas E. Earnhart, Kenneth A. Marek, Kenneth A. Cunefare

  • A State-Switched Absorber Used for Vibration Control of Continuous Systems

    by Mark H. Holdhusen, Kenneth A. Cunefare

    A state-switched absorber (SSA) is a device that is capable of switching between discrete stiffnesses; thus, it is able to instantaneously switch between resonance frequencies. The state-switched absorber is essentially a passive vibration absorber between switch events; however, at each switch event the SSA instantly “retunes” its natural frequency and maintains that frequency until the next switch event. This paper considers the optimization of the state-switched absorber applied to a continuous vibrating system and details the experimental validation of these simulation results. A simulated annealing optimization algorithm was utilized to optimize the state-switched absorber. For the most part, the SSA performed only marginally better than a classical tuned vibration absorber (TVA). However, for a select few cases considered, the SSA was able to reduce the kinetic energy of the plate to which it is attached by 12.9dB over that of a classical tuned vibration absorber. The optimal SSA location on a clamped square plate was near the center of the plate for the vast majority of the forcing cases considered. To experimentally validate the simulation, a SSA was fabricated by employing magnetorheological elastomers to achieve a stiffness change. For several two-force component excitations, several tuning configurations of the SSA were applied and the kinetic energy of the system was found and optimized. As with the majority of the optimization cases, the experiments showed the SSA outperforming the TVA by only 2dB. When comparing the observed results to those found via simulation, the simulations accurately predicted the performance of the SSA in the experiments.