Hans-Hinrich Sievers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hans-Hinrich Sievers has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- J. F. Matthias Bechtel
Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bochum, Germany
15 shared publications Ulrich Stierle
9 shared publicationsClaus Bartels
Department for Cardiac Surgery, University Hospital Schleswig-Holstein, Luebeck, Germany
5 shared publications- Efstratios I. Charitos
Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
4 shared publications Armin Gorski
3 shared publicationsG. Richardt
Segeberger Kliniken GmbH
3 shared publications
Latest Publications
- 1 March 2015
- Vol. 24 (2) , 220-7
Age-related reoperation rate after the Ross procedure: a report from the German Ross Registry.
An increasing number of young adult patients are choosing bioprostheses for aortic valve replacement (AVR). In this context, the Ross operation deserves renewed consideration as an alternative biological substitute. After both the Ross procedure and bioprosthetic AVR, reoperation rates remain a concern and may be related to age at surgery. Herein are reported details of freedom from reoperation after the Ross procedure for different age groups. The reoperation rates of 1,925 patients (1,444 males, 481 females; mean age 41.2 ± 15.3 years) from the German Ross registry with a mean follow up of 7.4 ± 4.7 years (range: 0.00-18.51 years; total 12,866.6 patient-years) were allocated to three age groups: group I < 40 years; group II 40-60 years; and group III > 60 years. At 10 years (respectively 15 years) of follow up, freedom from reoperation was 86% (76%) in group I, 93% (85%) in group II, and 89% (83%) in group III. There is some evidence that, at least during the first 10 and 15 years after AVR, the Ross procedure provides a significantly lower reoperation rate in young adult and middle-aged patients aged < 60 years. This information may be of interest to the patients' or physicians' decision-making for aortic valve surgery.
- 1 March 2015
- Vol. 24 (2) , 220-7
Age-related reoperation rate after the Ross procedure: a report from the German Ross Registry.
An increasing number of young adult patients are choosing bioprostheses for aortic valve replacement (AVR). In this context, the Ross operation deserves renewed consideration as an alternative biological substitute. After both the Ross procedure and bioprosthetic AVR, reoperation rates remain a concern and may be related to age at surgery. Herein are reported details of freedom from reoperation after the Ross procedure for different age groups. The reoperation rates of 1,925 patients (1,444 males, 481 females; mean age 41.2 ± 15.3 years) from the German Ross registry with a mean follow up of 7.4 ± 4.7 years (range: 0.00-18.51 years; total 12,866.6 patient-years) were allocated to three age groups: group I < 40 years; group II 40-60 years; and group III > 60 years. At 10 years (respectively 15 years) of follow up, freedom from reoperation was 86% (76%) in group I, 93% (85%) in group II, and 89% (83%) in group III. There is some evidence that, at least during the first 10 and 15 years after AVR, the Ross procedure provides a significantly lower reoperation rate in young adult and middle-aged patients aged < 60 years. This information may be of interest to the patients' or physicians' decision-making for aortic valve surgery.
- 1 January 2015
- Vol. 24 (1) , 4-9
Long-Term Results after Aortic Valve-Sparing-Reimplantation Operation (David) in Bicuspid Aortic Valve.
The aortic valve-sparing reimplantation operation (David) is increasingly used in patients with aortic root aneurysm and intact cusps. David's procedure is also feasible in patients with bicuspid aortic valve (BA), though few long-term data are available. An analysis was conducted of the long-term echocardiographic data from patients with BAV who had undergone David's procedure at early and long-term follow up (FU) examinations. Between 1994 and 2010, a total of 30 patients with BAV underwent David's procedure at the authors'institution. There were no in-hospital or late deaths, and the mean long-term FU was 6.64 ± 3.54 years (range: 3.2-20.1 years). The mean aortic regurgitation (AR) grade was increased from 0.26 ± 0.37 at early FU to 0.70 ± 0.80 at long-term FU (p = 0.013). Four patients (13%) had to be reoperated after 10.00 ± 4.74 years (range: 5.49-17.06 years) due to aortic stenosis (n = 1) and aortic insufficiency (n = 3); the latter three patients had a significant prolapse of both the fused and the non-coronary cusp of reconstruction. The mean AR grade was increased significantly but was ≤ I-II in 59% of patients and ≤ II in 93% of patients after a mean FU of 6.6 years. Patients with prolapsing non-coronary leaflet at reconstruction seemed vulnerable to recurrent AR. Among patients, survival was excellent, and the reoperation rate and hemodynamics acceptable. Long-term follow up data are necessary to further refine the surgical techniques employed and to improve the results achieved.
- 1 January 2015
- Vol. 24 (1) , 4-9
Long-Term Results after Aortic Valve-Sparing-Reimplantation Operation (David) in Bicuspid Aortic Valve.
The aortic valve-sparing reimplantation operation (David) is increasingly used in patients with aortic root aneurysm and intact cusps. David's procedure is also feasible in patients with bicuspid aortic valve (BA), though few long-term data are available. An analysis was conducted of the long-term echocardiographic data from patients with BAV who had undergone David's procedure at early and long-term follow up (FU) examinations. Between 1994 and 2010, a total of 30 patients with BAV underwent David's procedure at the authors'institution. There were no in-hospital or late deaths, and the mean long-term FU was 6.64 ± 3.54 years (range: 3.2-20.1 years). The mean aortic regurgitation (AR) grade was increased from 0.26 ± 0.37 at early FU to 0.70 ± 0.80 at long-term FU (p = 0.013). Four patients (13%) had to be reoperated after 10.00 ± 4.74 years (range: 5.49-17.06 years) due to aortic stenosis (n = 1) and aortic insufficiency (n = 3); the latter three patients had a significant prolapse of both the fused and the non-coronary cusp of reconstruction. The mean AR grade was increased significantly but was ≤ I-II in 59% of patients and ≤ II in 93% of patients after a mean FU of 6.6 years. Patients with prolapsing non-coronary leaflet at reconstruction seemed vulnerable to recurrent AR. Among patients, survival was excellent, and the reoperation rate and hemodynamics acceptable. Long-term follow up data are necessary to further refine the surgical techniques employed and to improve the results achieved.
- 1 April 2014
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 33 (4) , 451-452
CircuLite left ventricular assist device explantation: A word of caution
- 1 April 2014
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 33 (4) , 451-452
CircuLite left ventricular assist device explantation: A word of caution
- Open Access
- 1 January 2012
- Vol. 4 (2) , 119-23
Ross procedure.
In 1967 Donald Ross introduced the subcoronary Ross procedure consisting of transplantation of the autologous pulmonary valve into aortic position. We describe our 15-year experience in Ross procedures. 576 subcoronary operations have been performed (436 male and 140 female patients); the mean age was 45±11.9 years. (range, 13 to 70 years). The mean follow-up was 7±4.2 years (range, 0 to 16 years). There were 4597 patient years at follow-up with a clinical completeness of 95% and echo completeness of 91%. There were two operative deaths (0.3%) and 31 patients with reoperation. The survival is similar to that of the normal population and the freedom from allo- and autograft reoperation is 87% at 15 years. Autograft regurgitation at last examination was grade 0 in 40%, trace in 54%, grade I in 19%, grade II in 4% and grade III in 0.4%; the pressure gradient was smaller than 5 mmHg in 57% and between 5 and 10 mmHg in 24%. Only 6% had a transvalvular pressure gradient of more than 10 mmHg. After 15 years of experience it can be concluded that the subcoronary technique provides near normal survival in adult patients, with excellent hemodynamics and acceptable rate of reoperations.
- 1 January 2012
- Vol. 4 (2) , 119-23
Open AccessRoss procedure.
In 1967 Donald Ross introduced the subcoronary Ross procedure consisting of transplantation of the autologous pulmonary valve into aortic position. We describe our 15-year experience in Ross procedures. 576 subcoronary operations have been performed (436 male and 140 female patients); the mean age was 45±11.9 years. (range, 13 to 70 years). The mean follow-up was 7±4.2 years (range, 0 to 16 years). There were 4597 patient years at follow-up with a clinical completeness of 95% and echo completeness of 91%. There were two operative deaths (0.3%) and 31 patients with reoperation. The survival is similar to that of the normal population and the freedom from allo- and autograft reoperation is 87% at 15 years. Autograft regurgitation at last examination was grade 0 in 40%, trace in 54%, grade I in 19%, grade II in 4% and grade III in 0.4%; the pressure gradient was smaller than 5 mmHg in 57% and between 5 and 10 mmHg in 24%. Only 6% had a transvalvular pressure gradient of more than 10 mmHg. After 15 years of experience it can be concluded that the subcoronary technique provides near normal survival in adult patients, with excellent hemodynamics and acceptable rate of reoperations.
- 1 November 2011
- Vol. 20 (6) , 688-94
Pulmonary homograft morphology after the Ross procedure: a computed tomography study.
In patients undergoing the Ross procedure the autograft morphological characteristics have been well studied, but those of the homograft are less clear. The study aim was to describe the radiomorphological homograft characteristics in Ross patients, and to compare them with such characteristics in normal (control) subjects. A total of 79 Ross patients (68 males, 11 females; mean age 43 +/- 12.3 years) underwent a computed tomography (CT) scan at a mean of 31 +/- 26 months after surgery. A group of 123 patients without cardiovascular disease served as controls. Cryopreserved homografts were implanted in all Ross patients, with the majority being obtained from a single source. The mean donor age was 47 +/- 11 years, and the mean homograft diameter 25.4 +/- 1.3 mm (as provided at source). Electrocardiographic-gated CT reconstructions were used for the measurements. The smallest diameters were at the proximal anastomosis, and maximum diameters at the distal anastomosis (p <0.001). In controls, the minimum diameter was just proximal to the pulmonary valve annulus. In Ross patients, the homograft diameters were significantly smaller at all levels compared to controls. This effect persisted after taking into consideration patient age, height, gender, body surface area, and time since surgery. Notably, the measured homograft diameters were significantly smaller than those provided at source. The study results provided evidence of homograft shrinkage at all levels after the Ross procedure but, most prominently, at the level of the proximal suture line. This may have implications for novel preservation methods, as well as homograft size selection and implantation techniques.
- 1 November 2011
- Vol. 20 (6) , 688-94
Pulmonary homograft morphology after the Ross procedure: a computed tomography study.
In patients undergoing the Ross procedure the autograft morphological characteristics have been well studied, but those of the homograft are less clear. The study aim was to describe the radiomorphological homograft characteristics in Ross patients, and to compare them with such characteristics in normal (control) subjects. A total of 79 Ross patients (68 males, 11 females; mean age 43 +/- 12.3 years) underwent a computed tomography (CT) scan at a mean of 31 +/- 26 months after surgery. A group of 123 patients without cardiovascular disease served as controls. Cryopreserved homografts were implanted in all Ross patients, with the majority being obtained from a single source. The mean donor age was 47 +/- 11 years, and the mean homograft diameter 25.4 +/- 1.3 mm (as provided at source). Electrocardiographic-gated CT reconstructions were used for the measurements. The smallest diameters were at the proximal anastomosis, and maximum diameters at the distal anastomosis (p <0.001). In controls, the minimum diameter was just proximal to the pulmonary valve annulus. In Ross patients, the homograft diameters were significantly smaller at all levels compared to controls. This effect persisted after taking into consideration patient age, height, gender, body surface area, and time since surgery. Notably, the measured homograft diameters were significantly smaller than those provided at source. The study results provided evidence of homograft shrinkage at all levels after the Ross procedure but, most prominently, at the level of the proximal suture line. This may have implications for novel preservation methods, as well as homograft size selection and implantation techniques.
- Open Access
- 1 October 2011
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 13 (4) , 459
Corrigendum to 'Leukocyte depletion during cardiopulmonary bypass in routine adult cardiac surgery': [Interact CardioVasc Thorac Surg 12 (2011) 207-212]
- 1 October 2011
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 13 (4) , 459
Open AccessCorrigendum to 'Leukocyte depletion during cardiopulmonary bypass in routine adult cardiac surgery': [Interact CardioVasc Thorac Surg 12 (2011) 207-212]
- Open Access
- 1 April 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 40 (5) , 1127-1130
In vitro investigation of aortic valve annuloplasty using prosthetic ring devices
Objectives: The remodeling of the dilatated valve annulus with a prosthetic ring for the repair of valve insufficiency is a well-established concept in mitral valve surgery, and may also be suitable for aortic valve reconstruction. In this study, two models of prosthetic aortic annuloplasty devices were investigated. Methods: Fresh porcine aortic roots (n = 16) were investigated in a pulsatile flow simulator after patch dilatation of the annulus and subsequent reconstruction using both an external and an internal prosthetic ring. For each configuration, leakage was determined by ultrasonic flow measurements and leaflet co-aptation by transesophageal echocardiography. In addition, valves’ motions were recorded by high-speed video. Results: By the use of the prosthetic annuloplasty rings, leakage volumes decreased significantly compared with the dilatated root, more pronounced with the intra-annular ring. Similarly, the co-aptation height of the leaflets increased. Pressure gradients were not significantly influenced by the ring application, but leaflet motion patterns changed from the usual trapezoid to a more rectangular opening characteristic, visible at both echocardiographic and high-speed video analysis. Conclusions: The reconstruction of a dilatated aortic valve annulus using external and internal ring devices is feasible and effective for reduction of regurgitation at which the internal ring provides a greater potential to decrease valve insufficiency.
- 1 April 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 40 (5) , 1127-1130
Open AccessIn vitro investigation of aortic valve annuloplasty using prosthetic ring devices
Objectives: The remodeling of the dilatated valve annulus with a prosthetic ring for the repair of valve insufficiency is a well-established concept in mitral valve surgery, and may also be suitable for aortic valve reconstruction. In this study, two models of prosthetic aortic annuloplasty devices were investigated. Methods: Fresh porcine aortic roots (n = 16) were investigated in a pulsatile flow simulator after patch dilatation of the annulus and subsequent reconstruction using both an external and an internal prosthetic ring. For each configuration, leakage was determined by ultrasonic flow measurements and leaflet co-aptation by transesophageal echocardiography. In addition, valves’ motions were recorded by high-speed video. Results: By the use of the prosthetic annuloplasty rings, leakage volumes decreased significantly compared with the dilatated root, more pronounced with the intra-annular ring. Similarly, the co-aptation height of the leaflets increased. Pressure gradients were not significantly influenced by the ring application, but leaflet motion patterns changed from the usual trapezoid to a more rectangular opening characteristic, visible at both echocardiographic and high-speed video analysis. Conclusions: The reconstruction of a dilatated aortic valve annulus using external and internal ring devices is feasible and effective for reduction of regurgitation at which the internal ring provides a greater potential to decrease valve insufficiency.
- Open Access
- 1 February 2011
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 12 (2) , 207-212
Leukocyte depletion during cardiopulmonary bypass in routine adult cardiac surgery
Objective: Cardiopulmonary bypass (CPB) elicts an inflammatory response which is potentially harmful and that is partly caused by activation of leuko
- 1 February 2011
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 12 (2) , 207-212
Open AccessLeukocyte depletion during cardiopulmonary bypass in routine adult cardiac surgery
Objective: Cardiopulmonary bypass (CPB) elicts an inflammatory response which is potentially harmful and that is partly caused by activation of leuko
- 1 October 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 140 (4) , 816-822.e5
Fourteen years' experience with 501 subcoronary Ross procedures: Surgical details and results
- 1 October 2010
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 140 (4) , 816-822.e5
Fourteen years' experience with 501 subcoronary Ross procedures: Surgical details and results
- 19 December 2009
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 24 (1) , 14-21
Technik des Aortenwurzelersatzes
- 19 December 2009
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 24 (1) , 14-21
Technik des Aortenwurzelersatzes