Henk A. Claessens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Henk A. Claessens has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Carel A. Cramers
Eindhoven University of Technology, Department of Chemical Engineering and Chemistry, Laboratory of Instrumental Analysis, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
4 shared publicationsJan Jiskra
Synthon BV, P.O. BOX 7071, 6503 GN Nijmegen, the Netherlands
2 shared publicationsA. Houbenová
Eindhoven University of Technology, Laboratory of Instrumental Analysis , P. O. Box 513, 5600 MB, Eindhoven, The Netherlands
1 shared publicationBart A.J. van Landeghem
Department of Clinical Chemistry and Hematology, St. Elisabeth Hospital, P.O. Box 90151, 5000 LC Tilburg, The Netherlands
1 shared publicationC. A. Cramers
Eindhoven University of Technology, Laboratory of Instrumental Analysis , P. O. Box 513, 5600 MB, Eindhoven, The Netherlands
1 shared publicationC.A Cramers
Laboratory of Instrumental Analysis, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, the Netherlands
1 shared publication
Latest Publications
- 5 August 2005
- Published by Elsevier in Journal of Chromatography B
- Vol. 822 (1-2) , 316-321
The analysis of thiamin and its derivatives in whole blood samples under high pH conditions of the mobile phase
- 5 August 2005
- Published by Elsevier in Journal of Chromatography B
- Vol. 822 (1-2) , 316-321
The analysis of thiamin and its derivatives in whole blood samples under high pH conditions of the mobile phase
- 1 December 2004
- Published by Elsevier in Journal of Chromatography A
- Vol. 1060 (1-2) , 23-41
Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography
- 1 December 2004
- Published by Elsevier in Journal of Chromatography A
- Vol. 1060 (1-2) , 23-41
Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography
- 7 May 2004
- Published by Springer Nature in Chromatographia
- Vol. 59 (9-10) , 579-589
Theoretical Aspects of Gradient Reversed-Phase High Performance Liquid Chromatography of Styrene ? Butylacrylate Block Copolymers
- 7 May 2004
- Published by Springer Nature in Chromatographia
- Vol. 59 (9-10) , 579-589
Theoretical Aspects of Gradient Reversed-Phase High Performance Liquid Chromatography of Styrene ? Butylacrylate Block Copolymers
- 15 October 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (15-16) , 1305-1330
Stationary and mobile phases in capillary electrochromatography (CEC)
- 15 October 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (15-16) , 1305-1330
Stationary and mobile phases in capillary electrochromatography (CEC)
- 3 July 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (9-10) , 777-792
Quantitative structure‐retention relationships in reversed‐phase liquid chromatography using several stationary and mobile phases
Quantitative Structure‐Retention Relationships (QSRRs) have been employed to study retention mechanism of Reversed‐Phase Liquid Chromatography (RPLC). Two C18 and two C8 columns were used with mobile phases containing methanol, acetonitrile, and tetrahydrofuran in concentrations ranging from 40 to 90 (v/v)% in water. QSRR equations derived are generally characterized by a satisfactory quality of fit, although missing data or a low average retention can decrease the goodness‐of‐fit. In agreement with literature the most important retention descriptors appeared to be the analyte's molecular volume and its hydrogen‐bond accepting basicity, but also the polarity/polarizability, hydrogen‐bond donating acidity, and excess molar refraction showed statistical significance in several cases. Relatively small, but significant differences between the two C18 stationary phases were observed. The differences between C8 and C18 column types were more pronounced. The influence of the mobile phase on regression coefficients is more difficult to interpret, because of adsorption of mobile phase constituents by the stationary phase. However, the importance of this partitioning of water and modifier is illustrated by the practically identical trends in b values for the three modifiers studied, while the trends in v values are significantly different. Principal component analysis of the QSRR regression coefficients demonstrated the prevailing role of the mobile phase for chromatographic properties of the RPLC systems studied as compared to the stationary phase.
- 3 July 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (9-10) , 777-792
Quantitative structure‐retention relationships in reversed‐phase liquid chromatography using several stationary and mobile phases
Quantitative Structure‐Retention Relationships (QSRRs) have been employed to study retention mechanism of Reversed‐Phase Liquid Chromatography (RPLC). Two C18 and two C8 columns were used with mobile phases containing methanol, acetonitrile, and tetrahydrofuran in concentrations ranging from 40 to 90 (v/v)% in water. QSRR equations derived are generally characterized by a satisfactory quality of fit, although missing data or a low average retention can decrease the goodness‐of‐fit. In agreement with literature the most important retention descriptors appeared to be the analyte's molecular volume and its hydrogen‐bond accepting basicity, but also the polarity/polarizability, hydrogen‐bond donating acidity, and excess molar refraction showed statistical significance in several cases. Relatively small, but significant differences between the two C18 stationary phases were observed. The differences between C8 and C18 column types were more pronounced. The influence of the mobile phase on regression coefficients is more difficult to interpret, because of adsorption of mobile phase constituents by the stationary phase. However, the importance of this partitioning of water and modifier is illustrated by the practically identical trends in b values for the three modifiers studied, while the trends in v values are significantly different. Principal component analysis of the QSRR regression coefficients demonstrated the prevailing role of the mobile phase for chromatographic properties of the RPLC systems studied as compared to the stationary phase.
- 28 January 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (1-2) , 43-52
Separation of basic central nervous system drugs by capillary electrochromatography
This article describes the sample preparation and separation of three strongly basic central nervous system (CNS) drugs by capillary electrochromatography. The separation was developed on Hypersil C8 MOS and Hypersil Phenyl stationary phases using acetonitrile (ACN) as organic modifier together with mobile phase additives, ammonia, ethylenediamine, or 1,3‐diaminopropane. A successful, fast separation after a simple derivatization procedure of the compound was achieved on the Hypersil Phenyl stationary phase using ethylenediamine as mobile phase additive. The general approach to method development for complex mixtures is discussed.
- 28 January 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (1-2) , 43-52
Separation of basic central nervous system drugs by capillary electrochromatography
This article describes the sample preparation and separation of three strongly basic central nervous system (CNS) drugs by capillary electrochromatography. The separation was developed on Hypersil C8 MOS and Hypersil Phenyl stationary phases using acetonitrile (ACN) as organic modifier together with mobile phase additives, ammonia, ethylenediamine, or 1,3‐diaminopropane. A successful, fast separation after a simple derivatization procedure of the compound was achieved on the Hypersil Phenyl stationary phase using ethylenediamine as mobile phase additive. The general approach to method development for complex mixtures is discussed.
- 1 June 2002
- Published by Wiley in Journal of Separation Science
- Vol. 25 (9) , 569-576
Thermodynamic behaviour in capillary electrochromatography
- 1 June 2002
- Published by Wiley in Journal of Separation Science
- Vol. 25 (9) , 569-576
Thermodynamic behaviour in capillary electrochromatography
- 16 July 2001
- Published by Elsevier in Journal of Chromatography A
- Vol. 923 (1-2) , 215-227
Preparation and characterization of monolithic polymer columns for capillary electrochromatography
- 16 July 2001
- Published by Elsevier in Journal of Chromatography A
- Vol. 923 (1-2) , 215-227
Preparation and characterization of monolithic polymer columns for capillary electrochromatography
- 1 January 1994
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 17 (1) , 49-68
An Investigation Concerning the Stability of a Sterically Protected Cyanopropyl Modified Silica Substrate
The hydrolytic stability of a sterically protected cyanopropyl modified silica phase, used in reversed-phase mode, has been studied. This Zorbax SB-CN stationary phase shows superior hydrolytic stability in comparison with conventional CN stationary phases against intensive flushing with aggressive eluents of high and low pH, plain and also with the addition of an organic modifier. In addition to chromatography and elemental analysis, solid-state NMR was also used to characterize the changes in the properties of these phases. Moreover, the effect of sample volume and nature of the sample solvent on overloading of the SB-CN columns was studied. Volume overloading was already observed, when 10 μl of the sample solved in pure organic modifier was injected on the column. On the other hand, if the eluent was used as the sample solvent, no significant loss of column performance could be observed, at least up to 50 μl of sample injections.
- 1 January 1994
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 17 (1) , 49-68
An Investigation Concerning the Stability of a Sterically Protected Cyanopropyl Modified Silica Substrate
The hydrolytic stability of a sterically protected cyanopropyl modified silica phase, used in reversed-phase mode, has been studied. This Zorbax SB-CN stationary phase shows superior hydrolytic stability in comparison with conventional CN stationary phases against intensive flushing with aggressive eluents of high and low pH, plain and also with the addition of an organic modifier. In addition to chromatography and elemental analysis, solid-state NMR was also used to characterize the changes in the properties of these phases. Moreover, the effect of sample volume and nature of the sample solvent on overloading of the SB-CN columns was studied. Volume overloading was already observed, when 10 μl of the sample solved in pure organic modifier was injected on the column. On the other hand, if the eluent was used as the sample solvent, no significant loss of column performance could be observed, at least up to 50 μl of sample injections.