Anis Baraka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anis Baraka has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
M Muallem
8 shared publicationsMohamad El-Khatib
American University of Beirut Medical Center
5 shared publicationsSamar K. Taha
5 shared publicationsMohamad F. El-Khatib
Department of Anesthesiology, American University of Beirut, P.O.Box: 11-0236, Beirut 1107 2020, Lebanon
4 shared publicationsRoland N. Kaddoum
American University of Beirut
4 shared publicationsA N Sibai
Department of Anesthesiology, American University of Beirut Medical Center, Beirut, Lebanon
3 shared publications
Latest Publications
- 1 June 2008
- Vol. 19 (5) , 941-5
Carcinoid disease and anesthesia.
- 1 October 2007
- Vol. 19 (3) , 527-36
Progressive hypoxemia, hypercarbia and hyperthermia associated with prolonged anesthesia--a case report.
The authors report a case of 66-year-old female patient, 55 kg, ASA I who, under general anesthesia in supine position, developed gradual hypoxemia (from a baseline PaO2 of 250 to 91 mmHg), carbon dioxide build up (from a baseline PaCO2 31 to 41 mmHg) associated with gradual hyperthermia up to 38.3 degrees C over seven hours, intraoperatively. These observations were noted while using a semi-closed carbon dioxide absorption circuit in conjunction with the Hygroster filter at a fresh gas flow of 4 1/min of 50% nitrous oxide in oxygen. While the ventilation pattern was unchanged throughout the procedure, there was a change in exhaled tidal and minute ventilation volume with a net decrease of 28 ml and 0.4 l/min respectively. Findings are probably the result of pulmonary atelecatasis under general anesthesia due to the use of a relatively high-inspired oxygen concentration (50%). In addition, the use of a high humidity and temperature heat moisture exchanger (HME) filter (Hygroster) in conjunction with the circle absorber system may have resulted in over humidification and aggravated the pulmonary atelecatasis over the long operative time.
- 1 October 2007
- Vol. 19 (3) , 527-36
Progressive hypoxemia, hypercarbia and hyperthermia associated with prolonged anesthesia--a case report.
The authors report a case of 66-year-old female patient, 55 kg, ASA I who, under general anesthesia in supine position, developed gradual hypoxemia (from a baseline PaO2 of 250 to 91 mmHg), carbon dioxide build up (from a baseline PaCO2 31 to 41 mmHg) associated with gradual hyperthermia up to 38.3 degrees C over seven hours, intraoperatively. These observations were noted while using a semi-closed carbon dioxide absorption circuit in conjunction with the Hygroster filter at a fresh gas flow of 4 1/min of 50% nitrous oxide in oxygen. While the ventilation pattern was unchanged throughout the procedure, there was a change in exhaled tidal and minute ventilation volume with a net decrease of 28 ml and 0.4 l/min respectively. Findings are probably the result of pulmonary atelecatasis under general anesthesia due to the use of a relatively high-inspired oxygen concentration (50%). In addition, the use of a high humidity and temperature heat moisture exchanger (HME) filter (Hygroster) in conjunction with the circle absorber system may have resulted in over humidification and aggravated the pulmonary atelecatasis over the long operative time.
- 1 September 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (9) , 744-747
Noninvasive bilevel positive airway pressure for preoxygenation of the critically ill morbidly obese patient
We describe the use of noninvasive bilevel positive airway pressure (BiPAP) in a critically ill, hypoxemic and morbidly obese patient for preoxygenation prior to rapid sequence induction of anesthesia. A critically ill morbidly obese patient (body mass index: 49 kg·m-2) was scheduled for urgent laparoscopic cholecystectomy. Preoxygenation with 5 L·min-1 oxygen flow resulted in a moderate increase in oxygen saturation (SPO2) from 79% to 90%. Prior to rapid sequence induction of anesthesia, a trial of noninvasive BiPAP with oxygen delivery at 5 L·min-1 increased his SPO2to 95% initially, with full saturation of 99% achieved when oxygen flow was increased to 10 L·min-1. Bilevel positive airway pressure with an inspiratory and expiratory pressures of 17 cm H2O and 7 cm H2O, respectively, was applied using a full face mask to achieve a tidal volume of 8 mL·kg-1. Rapid sequence induction proceeded uneventfully. Prior to rapid sequence induction of anesthesia in patients with respiratory compromise secondary to factors which reduce FRC, noninvasive BiPAP in combination with supplemental oxygen may be indicated whenever traditional preoxygenation does not provide adequate oxyhemoglobin saturation. Improved oxygenation is most likely attributable to improved ventilation and alveolar recruitment. Nous décrivons l’utilisation de la ventilation en pression positive non invasive à bi-niveau (BiPAP) chez un patient sévèrement malade, hypoxémique et obèse morbide, pour la préoxygénation précédant l’induction de l’anesthésie en séquence rapide. Un patient sévèrement malade et obèse morbide (indice de masse corporelle: 49 kg·m-2) s’est présenté pour une cholécystectomie laparoscopique urgente. La préoxygénation avec un débit d’oxygène de 5 L·min-1 a eu pour résultat une augmentation modérée de la saturation d’oxygène (SPO2) de 79 % à 90 %. Avant l’induction de l’anesthésie à séquence rapide, un essai de BiPAP non invasive avec un débit d’oxygène à 5 L·min-1 a accru sa SPO2 à 95% initialement, avec une saturation complète achevée à 99 % lorsque le débit d’oxygène a été accru à 10 L·min-1. La ventilation en pression positive bi-niveau avec des pressions inspiratoire et expiratoire de 17 cm H2O et 7 cm H2O respectivement a été appliquée à l’aide d’un masque facial total afin d’obtenir un volume courant de 8 mL·kg-1. L’induction à séquence rapide s’est déroulée sans incident. Avant l’induction de l’anesthésie à séquence rapide chez les patients présentant des difficultés respiratoires secondaires à des facteurs réduisant la capacité fonctionnelle résiduelle, la BiPAP non invasive combinée à de l’oxygène supplémentaire pourrait être indiquée lorsque la préoxygénation traditionnelle ne fournit pas une saturation de l’oxyhémoglobine appropriée. Une meilleure oxygénation est sans doute attribuable à une meilleure ventilation et à un meilleur recrutement alvéolaire.
- 1 September 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (9) , 744-747
Noninvasive bilevel positive airway pressure for preoxygenation of the critically ill morbidly obese patient
We describe the use of noninvasive bilevel positive airway pressure (BiPAP) in a critically ill, hypoxemic and morbidly obese patient for preoxygenation prior to rapid sequence induction of anesthesia. A critically ill morbidly obese patient (body mass index: 49 kg·m-2) was scheduled for urgent laparoscopic cholecystectomy. Preoxygenation with 5 L·min-1 oxygen flow resulted in a moderate increase in oxygen saturation (SPO2) from 79% to 90%. Prior to rapid sequence induction of anesthesia, a trial of noninvasive BiPAP with oxygen delivery at 5 L·min-1 increased his SPO2to 95% initially, with full saturation of 99% achieved when oxygen flow was increased to 10 L·min-1. Bilevel positive airway pressure with an inspiratory and expiratory pressures of 17 cm H2O and 7 cm H2O, respectively, was applied using a full face mask to achieve a tidal volume of 8 mL·kg-1. Rapid sequence induction proceeded uneventfully. Prior to rapid sequence induction of anesthesia in patients with respiratory compromise secondary to factors which reduce FRC, noninvasive BiPAP in combination with supplemental oxygen may be indicated whenever traditional preoxygenation does not provide adequate oxyhemoglobin saturation. Improved oxygenation is most likely attributable to improved ventilation and alveolar recruitment. Nous décrivons l’utilisation de la ventilation en pression positive non invasive à bi-niveau (BiPAP) chez un patient sévèrement malade, hypoxémique et obèse morbide, pour la préoxygénation précédant l’induction de l’anesthésie en séquence rapide. Un patient sévèrement malade et obèse morbide (indice de masse corporelle: 49 kg·m-2) s’est présenté pour une cholécystectomie laparoscopique urgente. La préoxygénation avec un débit d’oxygène de 5 L·min-1 a eu pour résultat une augmentation modérée de la saturation d’oxygène (SPO2) de 79 % à 90 %. Avant l’induction de l’anesthésie à séquence rapide, un essai de BiPAP non invasive avec un débit d’oxygène à 5 L·min-1 a accru sa SPO2 à 95% initialement, avec une saturation complète achevée à 99 % lorsque le débit d’oxygène a été accru à 10 L·min-1. La ventilation en pression positive bi-niveau avec des pressions inspiratoire et expiratoire de 17 cm H2O et 7 cm H2O respectivement a été appliquée à l’aide d’un masque facial total afin d’obtenir un volume courant de 8 mL·kg-1. L’induction à séquence rapide s’est déroulée sans incident. Avant l’induction de l’anesthésie à séquence rapide chez les patients présentant des difficultés respiratoires secondaires à des facteurs réduisant la capacité fonctionnelle résiduelle, la BiPAP non invasive combinée à de l’oxygène supplémentaire pourrait être indiquée lorsque la préoxygénation traditionnelle ne fournit pas une saturation de l’oxyhémoglobine appropriée. Une meilleure oxygénation est sans doute attribuable à une meilleure ventilation et à un meilleur recrutement alvéolaire.
- 13 July 2007
- Published by Wiley in Anaesthesia
- Vol. 62 (8) , 769-773
Supplementation of pre‐oxygenation in morbidly obese patients using nasopharyngeal oxygen insufflation
Summary: During apnoea following induction of anaesthesia, morbidly obese patients may suffer a rapid decrease in oxygen saturation. This study compares pre‐oxygenation alone with pre‐oxygenation followed by nasopharyngeal oxygen insufflation on the onset of desaturation occurring during the subsequent apnoea. A randomised controlled trial was performed in 34 morbidly obese patients undergoing gastric bypass or gastric band surgery. Seventeen patients received nasopharyngeal oxygen supplementation following pre‐oxygenation (Study group, body mass index = 41.8 (6.9) kg.m −2 ), and the other 17 patients received pre‐oxygenation alone (Control group, body mass index = 42.7 (5.4) kg.m −2 ). Time from the onset of apnoea until S p o 2 fell to 95% was compared between the two groups with a cut‐off of 4 min. In the control group, the S p o 2 fell from 100% to 95% during the subsequent apnoea in 145 (27) s, with a significantly negative correlation ( r 2 = 0.66, p < 0.05) between the time to desaturation to 95% and the body mass index. In the study group, the S p o 2 was maintained in 16 of 17 patients at 100% for 4 min when apnoea was terminated. In conclusion, nasopharyngeal oxygen insufflation following pre‐oxygenation in morbidly obese patients delays the onset of oxyhaemoglobin desaturation during the subsequent apnoea.
- 13 July 2007
- Published by Wiley in Anaesthesia
- Vol. 62 (8) , 769-773
Supplementation of pre‐oxygenation in morbidly obese patients using nasopharyngeal oxygen insufflation
Summary: During apnoea following induction of anaesthesia, morbidly obese patients may suffer a rapid decrease in oxygen saturation. This study compares pre‐oxygenation alone with pre‐oxygenation followed by nasopharyngeal oxygen insufflation on the onset of desaturation occurring during the subsequent apnoea. A randomised controlled trial was performed in 34 morbidly obese patients undergoing gastric bypass or gastric band surgery. Seventeen patients received nasopharyngeal oxygen supplementation following pre‐oxygenation (Study group, body mass index = 41.8 (6.9) kg.m −2 ), and the other 17 patients received pre‐oxygenation alone (Control group, body mass index = 42.7 (5.4) kg.m −2 ). Time from the onset of apnoea until S p o 2 fell to 95% was compared between the two groups with a cut‐off of 4 min. In the control group, the S p o 2 fell from 100% to 95% during the subsequent apnoea in 145 (27) s, with a significantly negative correlation ( r 2 = 0.66, p < 0.05) between the time to desaturation to 95% and the body mass index. In the study group, the S p o 2 was maintained in 16 of 17 patients at 100% for 4 min when apnoea was terminated. In conclusion, nasopharyngeal oxygen insufflation following pre‐oxygenation in morbidly obese patients delays the onset of oxyhaemoglobin desaturation during the subsequent apnoea.
- 1 June 2007
- Vol. 19 (2) , 469-70
A simple approach to airway management in a child with a giant tongue hemangioma--a case report.
- 1 June 2007
- Vol. 19 (2) , 469-70
A simple approach to airway management in a child with a giant tongue hemangioma--a case report.
- 1 February 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (2) , 141-145
Preoxygenation with the Mapleson D system requires higher oxygen flows than Mapleson A or circle systems
- 1 February 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (2) , 141-145
Preoxygenation with the Mapleson D system requires higher oxygen flows than Mapleson A or circle systems
- 1 February 2007
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 106 (2) , 399-400
Depolarizing Block Is an Endplate-Muscular Block, Not a Neuromuscular Block
Depolarizing Block Is an Endplate-Muscular Block, Not a Neuromuscular Block Anis Baraka; Anesthesiology
- 1 February 2007
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 106 (2) , 399-400
Depolarizing Block Is an Endplate-Muscular Block, Not a Neuromuscular Block
Depolarizing Block Is an Endplate-Muscular Block, Not a Neuromuscular Block Anis Baraka; Anesthesiology
- 1 January 2007
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 104 (1) , 214-5
Can We Prevent Malignant Hyperthermia After Hypothermic Cardiopulmonary Bypass in a Malignant Hyperthermia-Susceptible Patient?
- 1 January 2007
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 104 (1) , 214-5
Can We Prevent Malignant Hyperthermia After Hypothermic Cardiopulmonary Bypass in a Malignant Hyperthermia-Susceptible Patient?
- 1 December 2006
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 20 (6) , 819-825
Correlation Between Cerebral and Mixed Venous Oxygen Saturation During Moderate Versus Tepid Hypothermic Hemodiluted Cardiopulmonary Bypass
- 1 December 2006
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 20 (6) , 819-825
Correlation Between Cerebral and Mixed Venous Oxygen Saturation During Moderate Versus Tepid Hypothermic Hemodiluted Cardiopulmonary Bypass
- 11 September 2006
- Published by Wiley in Anaesthesia
- Vol. 61 (10) , 1015-1016
Pharyngeal oxygen insufflation via the laryngoscope blade
- 11 September 2006
- Published by Wiley in Anaesthesia
- Vol. 61 (10) , 1015-1016
Pharyngeal oxygen insufflation via the laryngoscope blade