Alex MacKay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex MacKay has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
C. Laule
Department of Radiology, University of British Columbia Hospital, Vancouver, Canada
3 shared publicationsCornelia Laule
Department of Radiology, University of British Columbia
3 shared publicationsD. K. B. Li
Department of Radiology, University of British Columbia Hospital, Vancouver, Canada
3 shared publicationsE. E. Brief
Department of Physics and Astronomy, University of British Columbia, Vancouver, Canada
3 shared publications- Cornelia Laule
University of British Columbia
2 shared publications K. P. Whittall
Department of Radiology, Vancouver General Hospital University Site, Vancouver, Canada
2 shared publications
Latest Publications
- Open Access
- 1 August 2021
- Published by Elsevier in NeuroImage
- Vol. 236, 118046
Temperature dependence and histological correlation of inhomogeneous magnetization transfer and myelin water imaging in ex vivo brain
- 1 August 2021
- Published by Elsevier in NeuroImage
- Vol. 236, 118046
Open AccessTemperature dependence and histological correlation of inhomogeneous magnetization transfer and myelin water imaging in ex vivo brain
- Open Access
- 9 October 2019
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 7
Myelin Water Imaging and Transcranial Magnetic Stimulation Suggest Structure-Function Relationships in Multiple Sclerosis
Demyelination can be assessed structurally by magnetic resonance imaging (MRI) and functionally with transcranial magnetic stimulation (TMS). Here, we combined these techniques to investigate demyelination of the corpus callosum in multiple sclerosis (MS). Our objective was to determine if corpus callosal demyelination impacts transcallosal inhibition (TCI). TCI is a brief suppression of voluntary activity in the primary motor cortex elicited by stimulation of the homologous region of the contralateral hemisphere, which is assumed to be transmitted via the corpus callosum. MRI and TMS were performed in 26 participants with MS and 10 controls. Myelin water fraction (MWF) was measured in five regions of the corpus callosum and compared with the onset latency, duration, and depth of TCI as measured by electromyography at the forearm. Callosal MWF was greatest posteriorly compared to other regions of the corpus callosum. Lower MWF in MS compared to controls was more pronounced in the posterior corpus callosum. MS participants had a prolonged TCI duration (p = 0.016), which correlated with EDSS (p = 0.020) and disease duration (p = 0.045). In MS, TCI depth correlated negatively with the MWF of the posterior callosal midbody (p = 0.039), a region thought to mediate TCI transmission. In summary, TCI duration was increased in MS and demyelination of the posterior corpus callosum midbody was associated with measurable functional changes. This work demonstrates the potential for combining MRI and TMS with electromyography to draw insights about structure-function relationships in MS pathophysiology.
- 9 October 2019
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 7
Open AccessMyelin Water Imaging and Transcranial Magnetic Stimulation Suggest Structure-Function Relationships in Multiple Sclerosis
Demyelination can be assessed structurally by magnetic resonance imaging (MRI) and functionally with transcranial magnetic stimulation (TMS). Here, we combined these techniques to investigate demyelination of the corpus callosum in multiple sclerosis (MS). Our objective was to determine if corpus callosal demyelination impacts transcallosal inhibition (TCI). TCI is a brief suppression of voluntary activity in the primary motor cortex elicited by stimulation of the homologous region of the contralateral hemisphere, which is assumed to be transmitted via the corpus callosum. MRI and TMS were performed in 26 participants with MS and 10 controls. Myelin water fraction (MWF) was measured in five regions of the corpus callosum and compared with the onset latency, duration, and depth of TCI as measured by electromyography at the forearm. Callosal MWF was greatest posteriorly compared to other regions of the corpus callosum. Lower MWF in MS compared to controls was more pronounced in the posterior corpus callosum. MS participants had a prolonged TCI duration (p = 0.016), which correlated with EDSS (p = 0.020) and disease duration (p = 0.045). In MS, TCI depth correlated negatively with the MWF of the posterior callosal midbody (p = 0.039), a region thought to mediate TCI transmission. In summary, TCI duration was increased in MS and demyelination of the posterior corpus callosum midbody was associated with measurable functional changes. This work demonstrates the potential for combining MRI and TMS with electromyography to draw insights about structure-function relationships in MS pathophysiology.
- 1 April 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 37, 187-194
Simultaneous measurement of total water content and myelin water fraction in brain at 3 T using a T 2 relaxation based method
- 1 April 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 37, 187-194
Simultaneous measurement of total water content and myelin water fraction in brain at 3 T using a T 2 relaxation based method
- Open Access
- 1 June 2016
- Published by IOS Press in Brain Plasticity
- Vol. 2 (1) , 71-91
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
Myelin is critical for healthy brain function. An accurate in vivo measure of myelin content has important implications for understanding brain plasticity and neurodegenerative diseases. Myelin water imaging is a magnetic resonance imaging method which can be used to visualize myelination in the brain and spinal cord in vivo . This review presents an overview of myelin water imaging data acquisition and analysis, post-mortem validation work, findings in both animal and human studies and a brief discussion about other MR techniques purported to provide in vivo myelin content. Multi-echo T 2 relaxation approaches continue to undergo development and whole-brain imaging time now takes less than 10 minutes; the standard analysis method for this type of data acquisition is a non-negative least squares approach. Alternate methods including the multi-flip angle gradient echo mcDESPOT are also being used for myelin water imaging. Histological validation studies in animal and human brain and spinal cord tissue demonstrate high specificity of myelin water imaging for myelin. Potential confounding factors for in vivo myelin water fraction measurement include the presence of myelin debris and magnetization exchange processes. Myelin water imaging has successfully been used to study animal models of injury, applied in healthy human controls and can be used to assess damage and injury in conditions such as multiple sclerosis, neuromyelitis optica, schizophrenia, phenylketonuria, neurofibromatosis, niemann pick’s disease, stroke and concussion. Other quantitative magnetic resonance approaches that are sensitive to, but not specific for, myelin exist including magnetization transfer, diffusion tensor imaging and T 1 weighted imaging.
- 1 June 2016
- Published by IOS Press in Brain Plasticity
- Vol. 2 (1) , 71-91
Open AccessMagnetic Resonance of Myelin Water: An in vivo Marker for Myelin
Myelin is critical for healthy brain function. An accurate in vivo measure of myelin content has important implications for understanding brain plasticity and neurodegenerative diseases. Myelin water imaging is a magnetic resonance imaging method which can be used to visualize myelination in the brain and spinal cord in vivo . This review presents an overview of myelin water imaging data acquisition and analysis, post-mortem validation work, findings in both animal and human studies and a brief discussion about other MR techniques purported to provide in vivo myelin content. Multi-echo T 2 relaxation approaches continue to undergo development and whole-brain imaging time now takes less than 10 minutes; the standard analysis method for this type of data acquisition is a non-negative least squares approach. Alternate methods including the multi-flip angle gradient echo mcDESPOT are also being used for myelin water imaging. Histological validation studies in animal and human brain and spinal cord tissue demonstrate high specificity of myelin water imaging for myelin. Potential confounding factors for in vivo myelin water fraction measurement include the presence of myelin debris and magnetization exchange processes. Myelin water imaging has successfully been used to study animal models of injury, applied in healthy human controls and can be used to assess damage and injury in conditions such as multiple sclerosis, neuromyelitis optica, schizophrenia, phenylketonuria, neurofibromatosis, niemann pick’s disease, stroke and concussion. Other quantitative magnetic resonance approaches that are sensitive to, but not specific for, myelin exist including magnetization transfer, diffusion tensor imaging and T 1 weighted imaging.
- 1 April 2016
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 34 (3) , 246-251
Measuring water content using T2 relaxation at 3T: Phantom validations and simulations
- 1 April 2016
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 34 (3) , 246-251
Measuring water content using T2 relaxation at 3T: Phantom validations and simulations
- 20 December 2013
- Published by Springer Nature in Skeletal Radiology
- Vol. 43 (3) , 331-344
Using the dGEMRIC technique to evaluate cartilage health in the presence of surgical hardware at 3T: comparison of inversion recovery and saturation recovery approaches
To evaluate the effect of metal artifact reduction techniques on dGEMRIC T1 calculation with surgical hardware present. We examined the effect of stainless-steel and titanium hardware on dGEMRIC T1 maps. We tested two strategies to reduce metal artifact in dGEMRIC: (1) saturation recovery (SR) instead of inversion recovery (IR) and (2) applying the metal artifact reduction sequence (MARS), in a gadolinium-doped agarose gel phantom and in vivo with titanium hardware. T1 maps were obtained using custom curve-fitting software and phantom ROIs were defined to compare conditions (metal, MARS, IR, SR). A large area of artifact appeared in phantom IR images with metal when TI ≤ 700 ms. IR maps with metal had additional artifact both in vivo and in the phantom (shifted null points, increased mean T1 (+151 % IR ROIartifact) and decreased mean inversion efficiency (f; 0.45 ROIartifact, versus 2 for perfect inversion)) compared to the SR maps (ROIartifact: +13 % T1 SR, 0.95 versus 1 for perfect excitation), however, SR produced noisier T1 maps than IR (phantom SNR: 118 SR, 212 IR). MARS subtly reduced the extent of artifact in the phantom (IR and SR). dGEMRIC measurement in the presence of surgical hardware at 3T is possible with appropriately applied strategies. Measurements may work best in the presence of titanium and are severely limited with stainless steel. For regions near hardware where IR produces large artifacts making dGEMRIC analysis impossible, SR-MARS may allow dGEMRIC measurements. The position and size of the IR artifact is variable, and must be assessed for each implant/imaging set-up.
- 20 December 2013
- Published by Springer Nature in Skeletal Radiology
- Vol. 43 (3) , 331-344
Using the dGEMRIC technique to evaluate cartilage health in the presence of surgical hardware at 3T: comparison of inversion recovery and saturation recovery approaches
To evaluate the effect of metal artifact reduction techniques on dGEMRIC T1 calculation with surgical hardware present. We examined the effect of stainless-steel and titanium hardware on dGEMRIC T1 maps. We tested two strategies to reduce metal artifact in dGEMRIC: (1) saturation recovery (SR) instead of inversion recovery (IR) and (2) applying the metal artifact reduction sequence (MARS), in a gadolinium-doped agarose gel phantom and in vivo with titanium hardware. T1 maps were obtained using custom curve-fitting software and phantom ROIs were defined to compare conditions (metal, MARS, IR, SR). A large area of artifact appeared in phantom IR images with metal when TI ≤ 700 ms. IR maps with metal had additional artifact both in vivo and in the phantom (shifted null points, increased mean T1 (+151 % IR ROIartifact) and decreased mean inversion efficiency (f; 0.45 ROIartifact, versus 2 for perfect inversion)) compared to the SR maps (ROIartifact: +13 % T1 SR, 0.95 versus 1 for perfect excitation), however, SR produced noisier T1 maps than IR (phantom SNR: 118 SR, 212 IR). MARS subtly reduced the extent of artifact in the phantom (IR and SR). dGEMRIC measurement in the presence of surgical hardware at 3T is possible with appropriately applied strategies. Measurements may work best in the presence of titanium and are severely limited with stainless steel. For regions near hardware where IR produces large artifacts making dGEMRIC analysis impossible, SR-MARS may allow dGEMRIC measurements. The position and size of the IR artifact is variable, and must be assessed for each implant/imaging set-up.
- 19 May 2010
- Published by Wiley in NMR in Biomedicine
- Vol. 23 (9) , 1033-1037
Proton MRS of large multiple sclerosis lesions reveals subtle changes in metabolite T1 and area
The T1 values of metabolites were measured in eight subjects with clinically definite multiple sclerosis (MS) having at least one large brain lesion (2.6 ± 0.7 mL) and in eight age‐ and sex‐matched healthy controls. MRS examinations were conducted at 1.5 T using point‐resolved spectroscopy (PRESS) (TE = 30 ms, TR = 530, 750, 1200, 1500, 3500, 5000 ms). Spectra were acquired from a voxel placed in the largest lesion in the subject with MS, and in a corresponding voxel (same size and region) in normal white matter (NWM) in the matched control, and were fitted using LCModel. As there are regional variations in metabolite and water T1 and metabolite signal areas, careful placement of the control voxel was necessary to measure subtle differences between the lesions and NWM. The T1 and T1‐corrected signal areas of creatine were the same in MS lesions as in controls. The T1 values of choline were significantly shorter in MS lesions located in occipital and parietal, but not in frontal, white matter. N‐Acetylaspartate (NAA) and myoinositol T1 values in MS lesions were similar to those in NWM; however, the area of myoinositol correlated directly with lesion water T1, and the area of NAA correlated inversely with lesion water T1. MR spectra acquired at short TR require T1 correction of choline for accurate quantification. Careful voxel placement in controls to match lesion location in subjects with MS enables a clearer view of the subtle changes in lesions. Copyright © 2010 John Wiley & Sons, Ltd.
- 19 May 2010
- Published by Wiley in NMR in Biomedicine
- Vol. 23 (9) , 1033-1037
Proton MRS of large multiple sclerosis lesions reveals subtle changes in metabolite T1 and area
The T1 values of metabolites were measured in eight subjects with clinically definite multiple sclerosis (MS) having at least one large brain lesion (2.6 ± 0.7 mL) and in eight age‐ and sex‐matched healthy controls. MRS examinations were conducted at 1.5 T using point‐resolved spectroscopy (PRESS) (TE = 30 ms, TR = 530, 750, 1200, 1500, 3500, 5000 ms). Spectra were acquired from a voxel placed in the largest lesion in the subject with MS, and in a corresponding voxel (same size and region) in normal white matter (NWM) in the matched control, and were fitted using LCModel. As there are regional variations in metabolite and water T1 and metabolite signal areas, careful placement of the control voxel was necessary to measure subtle differences between the lesions and NWM. The T1 and T1‐corrected signal areas of creatine were the same in MS lesions as in controls. The T1 values of choline were significantly shorter in MS lesions located in occipital and parietal, but not in frontal, white matter. N‐Acetylaspartate (NAA) and myoinositol T1 values in MS lesions were similar to those in NWM; however, the area of myoinositol correlated directly with lesion water T1, and the area of NAA correlated inversely with lesion water T1. MR spectra acquired at short TR require T1 correction of choline for accurate quantification. Careful voxel placement in controls to match lesion location in subjects with MS enables a clearer view of the subtle changes in lesions. Copyright © 2010 John Wiley & Sons, Ltd.
- 1 February 2009
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 19 (1) , 1-26
MR Relaxation in Multiple Sclerosis
- 1 February 2009
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 19 (1) , 1-26
MR Relaxation in Multiple Sclerosis
- 31 October 2006
- Published by Elsevier in Schizophrenia Research
- Vol. 86, S76-S77
0460 ABNORMALITIES OF SUBREGIONAL MYELINATION IN FIRST-EPISODE PSYCHOSIS PATIENTS USING MYELIN WATER IMAGING
- 31 October 2006
- Published by Elsevier in Schizophrenia Research
- Vol. 86, S76-S77
0460 ABNORMALITIES OF SUBREGIONAL MYELINATION IN FIRST-EPISODE PSYCHOSIS PATIENTS USING MYELIN WATER IMAGING
- 1 May 2006
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 24 (4) , 515-525
Insights into brain microstructure from the T2 distribution
- 1 May 2006
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 24 (4) , 515-525
Insights into brain microstructure from the T2 distribution