RPRoland N. Pittman

Roland N. Pittman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Roland N. Pittman has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Aleksander S. Golub

    Department of Physiology, Virginia Commonwealth University/Medical College of Virginia Campus, Richmond, VA, USA

    2 shared publications
  • Christopher Gerald Ellis

    Department of Medical Biophysics, University of Western Ontario, London, Canada

    2 shared publications
  • Shruti A. Japee

    Department of Biomedical Engineering, Medical College of Virginia Campus, Virginia Commonwealth University, Richmond, 23298, USA

    2 shared publications
  • Aleksander S Golub

    Department of Physiology, Medical College of Virginia Campus, P.O. Box 980551, Virginia Commonwealth University, Richmond, Virginia 23298-0551, USA

    1 shared publication
  • Aleksander S. Popel

    Department of Biomedical Engineering, Johns Hopkins University, School of Medicine, Baltimore, MD, USA

    1 shared publication
  • Lane M. Smith

    Department of Physiology, Virginia Commonwealth University/Medical College of Virginia Campus, Richmond, VA 23298-0551, USA

    1 shared publication

Latest Publications

  • Automated Method for Tracking Individual Red Blood Cells Within Capillaries to Compute Velocity and Oxygen Saturation

    by Shruti A. Japee, Roland N. Pittman, Christopher G. Ellis

    Objective: The authors present a new method to track individual red blood cells (RBCs) as they move through capillaries. This method uses a recently developed Measurement and Analysis System for Capillary Oxygen Transport (MASCOT) and the concept of space–time images to track RBCs between consecutive frames of video recordings of the microcirculation.Methods: A space–time image displays in a single static image for a single capillary the location of all RBCs as a function of time. Analysis is performed on video tapes of RBC flow through capillaries to obtain velocity of individual cells as they traverse the capillary of interest. A space–time image is generated to track RBCs from one frame to the next and their velocities are computed. Based on the optical density values of each cell obtained from synchronized videotapes at two wavelengths, the oxygen saturation of a cell can be determined. In this manner, oxygen saturation can be tracked for the same cells as they move through the capillary.Results and Conclusions: These measurements, taken together, allow one to determine how much and how fast oxygen is being delivered to the surrounding tissue. This method provides, for the first time, a way to track individual RBCs flowing through capillary networks and study their RBC dynamics and oxygenation.


  • Letter to the Editor

    by Shwetal Patel, Roland N. Pittman

  • Flow Visualization Tools for Image Analysis of Capillary Networks

    by Shruti A. Japee, Christopher G. Ellis, Roland N. Pittman

    Objective: Video recordings of red blood cell (RBC) flow through capillary networks contain a considerable amount of information pertaining to oxygen transport through the microcirculation. Image analysis of these video recordings has been widely used to determine RBC dynamics (velocity, lineal density and supply rate) and oxygenation (Brunner et al., 2000; Ellis et al., 1990, 1992; Ellsworth et al., 1987; Klyscz et al., 1997; Pries 1988). However, not all capillaries in a given field of view are suitable for image analysis. Typically, capillary segments that are relatively straight and in sharp focus, and exhibit flow of individual RBCs that are well separated by plasma gaps, are good candidates for analysis. We have developed several image processing tools to aid in the selection of such capillaries for analysis and to obtain quick overviews of RBC flow through the microcirculation.Methods: Burgess et al. (Microcirc. 2:75, 1995) and Burkell et al. (Annals Biomed. Eng. 24:1, 1996; J. Vasc. Res. 35:2, 1998) have previously introduced mean and variance images to aid in the selection of capillaries for analysis. We have extended their concept and developed similar two dimensional visualization techniques for studies of RBC flow through capillary networks.Results: Five new methods of processing video data were developed. The minimum image highlights all capillaries containing RBCs in a given field of view. The maximum image identifies capillaries that exhibit high lineal density or stopped flow. The range image represents the difference between the maximum and minimum light intensity values that occur at a given pixel over a given time period, and helps to identify capillary segments that are in good focus and are perfused by RBCs and plasma. The difference image represents the cumulative sum of the square of differences in intensity values between consecutive frames and gives an indication of the frequency of passage of RBCs separated by plasma gaps. The transition image represents the number of times the intensity at a given pixel crosses a predefined threshold and indicates the number of RBCs (or trains of RBCs) that passes a given location during the observation period.Conclusions: The above flow visualization techniques are valuable tools to aid in the study of image focus, network geometry, RBC flow paths and dynamics, that can then be used in identifying capillaries for subsequent (separate) detailed analysis to provide quantitative information about RBC flow.


  • Interstitial Po2 Determination by Phosphorescence Quenching Microscopy

    by Lane M. Smith, Aleksander S. Golub, Roland N. Pittman

    Objective: This study introduces the technique of microinjection of phosphor probe into skeletal muscle tissue to determine oxygen tension (Po2) in the interstitium by phosphorescence quenching microscopy.Method: The spinotrapezius muscle of Wistar‐Kyoto rats weighing 240–280 g was surgically isolated and underwent the microinjection procedure. We measured the spatial distribution of phosphor probe 10, 30, and 80 minutes after injection; the tissue Po2 at sites adjacent to arteriolar and venular microvessels; and the decline in tissue Po2 during a 3‐minute period of 8‐Hz contraction.Results: The phosphorescence signal from the probe was undetectable outside a 2.5‐mm radius from the site of injection at the 10‐minute time point, increased to measurable values after 30 minutes, and was double the 30‐minute intensity value after 80 minutes. When used to measure periarteriolar Po2, the tissue microinjection technique demonstrated a nonlinear fall in tissue Po2 with distance away from secondary arterioles (30–40 µm diameter). Conversely, perivenular tissue Po2 increased in a nonlinear manner with distance away from secondary venules (60–70 µm diameter). The tissue Po2 at distances of 16 µm and greater from both types of secondary microvessels was significantly different from values taken directly over the centerline of these microvessels. During muscle contraction, the Po2 fell from a mean precontraction value of 28.3 ± 4.9 mmHg to 8.2 ± 0.9 mmHg at the end of the contraction period.Conclusions: These observations indicate that the microinjection technique yields values for tissue Po2 that are in good agreement with previously published results using oxygen microelectrodes.


  • Analysis of Phosphorescence Decay in Heterogeneous Systems: Consequences of Finite Excitation Flash Duration

    by Aleksander S. Golub, Aleksander S. Popel, Lei Zheng, Roland N. Pittman

    — Analysis of phosphorescence lifetimes using the Stern-Volmer equation is a reliable means of determining quencher concentration for a uniform sample. Methods of analysis for heterogeneous systems are based on the assumption that the excitation is produced by a momentary flash. This condition is an idealization because a real flash has a finite duration and a complex time profile. In the case of a heterogeneous quencher concentration, an excitation flash produces different initial intensities and different times of peak intensity from compartments having different concentrations of quencher. We formulated a model to explore the effects of flash duration on the shape of the emission curve obtained from systems in which the heterogeneity is continuous. We developed mathematical models that can be used to recover fitting parameters of continuous distributions of reciprocal lifetimes approximated as rectangular or Gaussian distributions, or an arbitrary histogram. We also formulated a procedure to convert the distribution of reciprocal lifetimes into a volume distribution of quencher concentration. We found that (1) the Stern-Volmer ratio of phosphorescence intensities cannot be employed for interpretation of pulse phosphorometric data in terms of a volume distribution of quencher; (2) shortening the flash duration decreases the difference of initial intensities between compartments having high and low quencher concentration; (3) the parameters of the volume distribution of quencher concentration can be recovered correctly only after taking account of the difference in initial intensities; and (4) calibration of the initial intensities for a given fitting delay and flash function is necessary.