CWChen Wang

Chen Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chen Wang has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Yi Zheng

    Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA

    8 shared publications
  • Yu Sun

    Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada

    8 shared publications
  • Dominick Amato

    Department of Medicine, Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada

    6 shared publications
  • Bernard Fernandes

    Department of Pathology and Laboratory Medicine, and Department of Medicine, Mount Sinai Hospital, University of Toronto, 600 University Avenue, Toronto, Ont., Canada M5G 1X5

    3 shared publications
  • John Nguyen

    Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON, Canada

    3 shared publications
  • Zhensong Xu

    Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON, Canada M5S 3G8

    3 shared publications

Latest Publications

  • Open Access

    Stiffness increase of red blood cells during storage

    by Zhensong Xu, Yi Zheng, Xian Wang, Nadine Shehata, Chen Wang, Yu Sun

    In transfusion medicine, the deformability of stored red blood cells (RBCs) changes during storage in blood banks. Compromised RBC deformability can reduce the transfusion efficiency or intensify transfusion complications, such as sepsis. This paper reports the microfluidic mechanical measurement of stored RBCs under the physiological deformation mode (that is, folding). Instead of using phenomenological metrics of deformation or elongation indices (DI or EI), the effective stiffness of RBCs, a flow velocity-independent parameter, is defined and used for the first time to evaluate the mechanical degradation of RBCs during storage. Fresh RBCs and RBCs stored up to 6 weeks (42 days) in the blood bank were measured, revealing that the effective stiffness of RBCs increases over the storage process. RBCs stored for 1 week started to show significantly higher stiffness than fresh RBCs, and stored RBC stiffness degraded faster during the last 3 weeks than during the first 3 weeks. Furthermore, the results indicate that the time points of the effective stiffness increase coincide well with the degradation patterns of S-nitrosothiols (SNO) and adenosine triphosphate (ATP) in RBC storage lesions.


  • Open Access

    Stiffening of sickle cell trait red blood cells under simulated strenuous exercise conditions

    by Zhensong Xu, Yi Zheng, Xian Wang, Nadine Shehata, Chen Wang, Shaorong Xie, Yu Sun

    The higher risk of vaso-occlusion events and sudden death for sickle-cell trait (SCT) athletes has been speculatively ascribed to SCT red blood cell (RBC) stiffening during strenuous exercise. However, the microenvironmental changes that could induce the stiffening of SCT RBCs are unknown. To address this question, we measured the mechanical properties of and changes in SCT RBCs under deoxygenated and acidic environments, which are two typical conditions present in the circulation of athletes undertaking strenuous exercise. The results reveal that SCT RBCs are inherently stiffer than RBCs from non-SCT healthy subjects, and a lower pH further stiffens the SCT cells. Furthermore, at both normal and low pH levels, deoxygenation was found to not be the cause of the stiffness of SCT RBCs. This study confirms that the stiffening of SCT RBCs occurs at a low pH and implies that SCT RBC stiffening could be responsible for vaso-occlusion in SCT athletes during strenuous exercise.


  • Clinicopathological and phenotypic features of chronic NK cell lymphocytosis identified among patients with asymptomatic lymphocytosis

    by F. Cao, H. Zhao, Y. Li, S. Dai, C. Wang

    Introduction Chronic natural killer (NK) cell lymphocytosis is currently a provisional entity. This study demonstrated NK cell lymphocytosis in patients with asymptomatic lymphocytosis and presented the hematological and phenotypic findings. Methods Flow cytometry analysis was performed for investigation of unexplained peripheral lymphocytosis. NK cells were determined by the phenotype of CD3−/CD16+/CD56+. Chronic NK cell lymphocytosis was defined by a NK cell count of ≥2 × 109/L, persistent for over 6 months, no evidence of B‐ or T‐cell clonality and no hematologic disorders. Results Among 190 patients with peripheral lymphocytosis, 15(7.9%) patients, age 42–72 years, were identified to have NK cell lymphocytosis, with a median NK cell count of 3.1 × 109/L (range 2.1–7.3 × 109/L). Persistent NK cell lymphocytosis was confirmed with a median follow‐up of 18 months. CD56bright NK cell populations were seen in eight patients and CD56dim NK cells in seven patients. CD57 co‐expression was seen in both CD56dim and CD56bright cells. CD7, CD2, or CD8 expression was seen in some of the NK populations. The NK cell lymphocytosis appeared stable and no progression to NK cell leukemia during the follow‐up period. Conclusion This study demonstrated that chronic NK cell lymphocytosis, similar to monoclonal B lymphocytosis or T‐cell clones, may account for asymptomatic lymphocytosis. There were no identifiable causes of the NK cell expansion. The variable phenotype may represent the heterogeneity and pathological features of NK lymphocytosis.


  • Mechanical differences of sickle cell trait (SCT) and normal red blood cells

    by Yi Zheng, Mark A. Cachia, Ji Ge, Zhensong Xu, Chen Wang, Yu Sun

    Sickle cell trait (SCT) is a condition in which an individual inherits one sickle hemoglobin gene (HbS) and one normal beta hemoglobin gene (HbA). It has been hypothesized that under extreme physical stress, the compromised mechanical properties of the red blood cells (RBCs) may be the underlying mechanism of clinical complications of sickle cell trait individuals. However, whether sickle cell trait (SCT) should be treated as physiologically normal remains controversial. In this work, the mechanical properties (i.e., shear modulus and viscosity) of individual RBCs were quantified using a microsystem capable of precisely controlling the oxygen level of RBCs' microenvironment. Individual RBCs were deformed under shear stress. After the release of shear stress, the dynamic cell recovery process was captured and analyzed to extract the mechanical properties of single RBCs. The results demonstrate that RBCs from sickle cell trait individuals are inherently stiffer and more viscous than normal RBCs from healthy donors, but oxygen level variations do not alter their mechanical properties or morphology.


  • Open Access

    Decreased deformability of lymphocytes in chronic lymphocytic leukemia

    by Yi Zheng, Jun Wen, John Nguyen, Mark A. Cachia, Chen Wang, Yu Sun

    This paper reports the first study of stiffness/deformability changes of lymphocytes in chronic lymphocytic leukemia (CLL) patients, demonstrating that at the single cell level, leukemic metastasis progresses are accompanied by biophysical property alterations. A microfluidic device was utilized to electrically measure cell volume and transit time of single lymphocytes from healthy and CLL patients. The results from testing thousands of cells reveal that lymphocytes from CLL patients have higher stiffness (i.e., lower deformability), as compared to lymphocytes in healthy samples, which was also confirmed by AFM indentation tests. This observation is in sharp contrast to the known knowledge on other types of metastatic cells (e.g., breast and lung cancer cells) whose stiffness becomes lower as metastasis progresses.


  • On-chip sample preparation for complete blood count from raw blood

    by John Nguyen, Yuan Wei, Yi Zheng, Chen Wang, Yu Sun

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new ‘offset’ filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100 000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.


  • Detection of malignant B lymphocytes by PCR clonality assay using direct lysis of cerebrospinal fluid and low volume specimens

    by L. Liu, F. Cao, S. Wang, J. Zhou, G. Yang, C. Wang

    Introduction: The diagnosis of lymphoid malignancies is often challenging in paucicellular specimens. PCR may also be limited by insufficient cells for DNA isolation and incomplete coverage of gene rearrangements. This study aims to evaluate a PCR method for IgH clonality using direct cell lysates.Methods: PCR amplification used cell lysate from detergent‐based lysis and BIOMED‐2 primers. CSF specimens were tested for 20 patients with primary CNS lymphoma or systemic lymphoma suspected for CNS involvement. Cytology and flow cytometry analysis was performed in parallel with PCR.Results: Direct lysis produced a better yield than the column‐based method for DNA isolation. PCR using lysate showed an efficiency of clonality detection from a minimum of 20 tumor cells. PCR clonality was found in nine of the 20 CSFs, and positive PCR was concordant with both cytology and flow cytometry in seven cases. There were two cases positive for PCR, but indeterminate for flow cytometry because of insufficient cell events. Of the eleven PCR‐negative cases, two were considered as false negative, as flow cytometry showed positive for malignant cells. The PCR was also performed successfully with a specimen from the anterior chamber of the eye.Conclusion: PCR clonality with direct cell lysis of CSF is feasible, and it may overcome the limitation of DNA isolation. This PCR method may be particularly useful for small volume and low cell CSF when flow cytometry is inconclusive.


  • Characterization of red blood cell deformability change during blood storage

    by Yi Zheng, Jun Chen, Tony Cui, Nadine Shehata, Chen Wang, Yu Sun

    Stored red blood cells (RBCs) show progressive deformability changes during blood banking/storage. Their deformability changes over an 8 weeks' storage period were measured using a microfluidic device. Hydrodynamic focusing controls the orientation and position of individual RBCs within the microchannel. High-speed imaging (5000 frames s−1) captures the dynamic deformation behavior of the cells, and together with automated image analysis, enables the characterization of over 1000 RBCs within 3 minutes. Multiple parameters including deformation index (DI), time constant (shape recovery rate), and RBC circularity were quantified. Compared to previous studies on stored RBC deformability, our results include a significantly higher number of cells (>1000 cells per sample vs. a few to tens of cells per sample) and, for the first time, reveal deformation changes of stored RBCs when traveling through human-capillary-like microchannels. Contrary to existing knowledge, our results demonstrate that the deformation index of RBCs under folding does not change significantly over blood storage. However, significant differences exist in time constants and circularity distribution widths, which can be used to quantify stored RBC quality or age.


  • Electrical measurement of red blood cell deformability on a microfluidic device

    by Yi Zheng, John Nguyen, Chen Wang, Yu Sun

    This paper describes a microfluidic system and a technique for electrically measuring the deformability of red blood cells (RBCs). RBCs are deformed when they flow through a small capillary (microfluidic channel). The microfluidic device consists of two stages of microchannels as two measurement units for measuring cell size/volume and cell deformability. A low frequency voltage signal is established across the microfluidic channel, and electrical current signal is sampled continuously when RBCs pass through the measurement areas. Mechanical opacity is defined to mitigate the coupled effect of cell size/volume and deformability. The system performed tests on controlled, glutaraldehyde-treated, and heated RBCs using a number of driving pressures. The experimental results proved the capability of the system for distinguishing different RBC populations based on their deformability with a throughput of ∼10 cells s−1.


  • High-throughput biophysical measurement of human red blood cells

    by Yi Zheng, Ehsan Shojaei-Baghini, Azar Azad, Chen Wang, Yu Sun

    This paper reports a microfluidic system for biophysical characterization of red blood cells (RBCs) at a speed of 100–150 cells s−1. Electrical impedance measurement is made when single RBCs flow through a constriction channel that is marginally smaller than RBCs' diameters. The multiple parameters quantified as mechanical and electrical signatures of each RBC include transit time, impedance amplitude ratio, and impedance phase increase. Histograms, compiled from 84,073 adult RBCs (from 5 adult blood samples) and 82,253 neonatal RBCs (from 5 newborn blood samples), reveal different biophysical properties across samples and between the adult and neonatal RBC populations. In comparison with previously reported microfluidic devices for single RBC biophysical measurement, this system has a higher throughput, higher signal to noise ratio, and the capability of performing multi-parameter measurements.