KMK. Mönkemüller

K. Mönkemüller

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


K. Mönkemüller has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • ESOPHAGEAL “OUTLET PATCHY VESICLES”: ENDOSCOPIC, MAGNIFICATION ENDOSCOPY, HISTOLOGIC AND ELECTRONMICROSCOPIC DESCRIPTION OF NEW LESIONS AT THE GASTROESOOPHAGEAL JUNCTION

    by K Mönkemüller, A Martínez-Alcalá García, C Delgado-Linares, P Malfertheiner, Lc Fry, H Neumann

    Aims: We have often observed the presence of small yellow vesicles or tiny submucosal cysts above the Z-line in a significant number of patients. These lesions have not been described in the literature. The aim of this study was to evaluate the incidence of these lesions and characterize them endoscopically and histolgically. Methods: 200 patients were prospectively and consecutively enrolled. The endoscopies were performed using standard and high-definition white light endoscopes with magnification (up to x 110). Histology (H&E). In 10 patients we also performed electron microscopy (magnification 7000x). All potential physiologic and pathologic lesions found in the esophagus and stomach were carefully searched and described for. The occurrence of these yellow vesicles was analyzed in the context of these lesions using univartiate and multivariate analysis, Mann-Whitney and Student t-test. Results: A total 197 were included (102 women and 95 men, mean age 55,5, SD+15) (three patiens were excluded). The incidence of yellow vesicles was 30% of EGDs. Some lesions had a shape of a “volcano” with zylidrical epithelium on its tip. Their sizes ranged from 3 mm to 12 mm. These yellow vesicles had a significant correlation with zylindrical esophageal epithelium (including Barrett esophagus) (p = 0,009) and inverse correlation with erosive esophagitis (p = 0.024) and female sex (p = 0,011). Histology and elctron microscopy demonstrated submucosal glands and zylindrical epithelium, including pancreatic and gastric metaplasia (the patholgist blinded to the study called these lesions “inlet patches”). Conclusions: Yellow vesicles in the distal esophagus are found in 30% of patients undergoing EGD for clinical symptoms. Yellow vesicles are inversely associated with columnar lined epithelium (Barrett esophagus) and positively associated with female sex and less erosive esophagitis, suggesting a protectiive mechanism of the GEJ. These lesions contain submucosal glands and gastric metaplasia and could be thus considered esophageal “outlet patches”.

  • SIMPLE AND PRACTICAL EX-VIVO, NON-BIOLOGIC SIMULATION MODEL FOR PLACEMENT OF SELF-EXPANDING METAL STENTS

    by A Martínez-Alcalá García, Ma D'Assuncao, G Schwingel, Am Ahmed, G Nelson, Lc Fry, K Mönkemüller

    Self-expanding metal stent placement is a key therapeutic intervention in gastrointestinal endoscopy. Unfortunately, there is lack of training models for SEMS. The training is further compounded by the need to “experiment” in humans during the initial stent release experiences. Whereas the presence of an expert alleviates the burden of this approach, it still remains a suboptimal approach to train the novice therapeutic endoscopist. We have 3 developed a simple, inexpensive, practical and reproducible model to train endoscopists to insert SEMS. The aim of this model is to provide the endoscopist with the essential steps and knowledge of endoscopic stenting, thus improving the manual and cognitive dexterity needed for this procedure. The model is based on a plastic tube measuring, which is tightly attached to a wood base. This platform can be easily transported and placed on any surface for training. A tube like sponge is inserted into the plastic tube. This sponge is cut at a specific level, where the “stricture” will be located. The sponge has two aims, one to serve as an esophagus and two to prevent scope damage while being advanced through the plastic tube. A key advantage of this model is its use with fluoroscopy. The video shows the key steps of SEMS placing, from endoscopy, to wire insertion and exchange, use of fluoroscopy and stent release. In sum, we believe that training models such as this one increase the cognitive and manual dexterity of endoscopists, and prepare them for a more precise and safer intervention in human beings.

  • EXTREME ENDOSCOPY: DIRECT JEJUNOSTOMY, ENDOSCOPIC RE-ANASTOMOSIS OF INTESTINES, PERCUTANEOUS ASSISTED TRANSPROSTHETIC THERAPY (PATENT) IN PATIENT ANASTOMOTIC DEHISCENCE AND COMPLEX PLEUROPERITONEAL ABSCESS AFTER PANCREATIC SURGERY

    by A Martínez-Alcalá García, Tp Kroner, Am Ahmed, I Jovanovic, L Fry, Ma D'Assunção, K Mönkemüller

    A 52-year old female with history of Roux-en-Y gastric bypass underwent resection of a huge pancreatic cystic tumor of the pancreas. Postoperatively an amylase-rich pleural and retroperitoneal fluid collection was noted, which was drained radiologically. Her clinical status was poor, she was septic and her albumin was 1.2 g/L (normal > 3.5). The patient was referred for double balloon (DEB)-ERCP for a suspected pancreatic duct leak. During endoscopy it became evident that the jejunogastric anastomosis was completely disrupted, communicating with a large peritoneo-pleural abscess. At this moment change in plans became mandatory. First, a direct, DBE assisted-jejunostomy was performed after successfully finding a tiny communication to the jejunum within the disrupted anastomosis. Second, a large bore overtube was inserted per-orally into the abscess cavity and a gastroscope covered with a transparent cap was passed multiple times to remove copious amounts of pus, debris and food. Third, the disrupted bowel was re-anastomosed endoscopically using overtube-assisted technique to deliver a fully covered self-expanding metal stent (SEMS), which was then anchored to the esophagus using an over-the-scope clip to prevent distal migration. And finally, percutaneous assisted transprosthetic endoscopic therapy (PATENT) with another fully covered esophageal SEMS was performed after dilating the skin and muscle with an esophageal balloon. Subsequently Endovac therapy (Endosponge) was done to drain and close the abscessed cavity. The endoscopic interventions lasted 4 hours. On follow-up two months later, the endoscopic stent with its over-the-scope clip was removed and a small remnant anastomotic esophagopleural fistula was repaired using an over-the-scope-clip.

  • PERFORATION AFTER BALLOON DILATION OF ACHALASIA TREATED WITH SELF-EXPANDING METAL STENT: MY AWFUL DAY!

    by A Martínez-Alcalá García, Kröner, Lc Fry, K Mönkemüller

    A 72-year old man with achalasia underwent balloon dilation. Following dilation there was a huge and deep laceration. No contrast extravasation was seen. However, the laceration was deep and there was concern for microperforation. Therefore, we decided insert a fully-covered self expanding metal stent (fcSEMS). The fcSEMS was placed in correct position and the patient was admitted to the hospital, where he remained stable for 24 hours, after which he was discharged home in stable condition. The plan was to electively remove the stent in 2 weeks. The patient, however, returned after one week with massive vomiting. Upon EGD the stent had slipped and migrated distally, embedding into the stomach, blocking the transit of the food bolus or liquids. The stent was deeply embedded, and various efforts to remove it proximally were futile. These efforts included grasping the stent with snares and various types of forceps. Finally, after tightly grasping the proximal part of the fcSEMS with a rat tooth forceps and constant, but gentle pulling using a torque-like movement and rotation, it was possible to disengage the stent from the stomach and esophageal attachments. Upon visualization of the proximal part of the fcSEMS coming out of the hypopharynx, victory was declared, but suddenly the forceps lost the stent, the stent slid back into the hypopharynx and esophagus. Nevertheless, the quick reaction of the nurse assistant saved the situation, as her quick fingers grabbed the stent. Evidently, the game was not over, as once the proximal third of the stent was out of the mouth of the patient, the patient started to wake up from sedation and his strong teeth closed tightly around the stent. Gentle action by the entire team finally convinced the patient to release the stent and put an end to this awful day.

  • ENDOSCOPIC CLOSURE OF GIANT ESOPHAGEAL PERFORATION IN BOERHAAVE'S SYNDROME USING SPONGE AND VACUUM THERAPY

    by G Loske, A Martinez-Alcala, Lc Fry, K Mönkemüller

    Esophageal perforation in the setting of Boerhaave's syndrome is highly letal. The main treatment option is thoracotomy with surgical drainage. Occasionally the use of fully covered metal stents may assist closing smaller perforation, Herein we present the effectiveness of endoscopic sponge and vacuum therapy to fully close a huge esophageal perforation with mediastinal cavity in a severely ill patient. A 68-year old man with diabetes mellitus, hypertension and atherosclerosis presented with massive vomiting, retching, hematemesis and hypotension. Urgent endoscopy revealed a 3 cm long esophageal perforation communicating with a large mediastinal cavity filled with fibrin and blood clots. The patient was in hemodynamic and septic shock and surgery was not an option. Therefore, we decided to use endoscopic sponge-vacuum therapy. The patient was intubated, admitted to the intensive care unit and broad-spectrum antibiotics and antifungals were started. Intracavitary endoscopic vacuum therapy started with insertion of open-pore polyurethane foam (sponge) into the extraluminary cavity. The sponge was attached to a nasogastric tube. The nasogastric tube was attached to constant negative pressure (125 mm of Hg). On day four EGD revealed a complete drainage of the infection focus with initial closure of the perforation defect. On this day, an exchange was performed and a new sponge set was inserted into the shrinking cavity. A third endoscopy was performed on day No. 8. Now it was evident that the cavity had massively shrunk in size and the cavity had assumed a pseudodiverticular shape. The patient was kept NPO and three days later a follow-up endoscopy revealed a defect closure. Evidently, the final closure occurred in secondary intention. The patient was allowed to eat and was discharged home in stable condition two days later. This case demonstrates on the utility of endoscopic vacuum therapy using endosponge to close a complex perforation of the esophagus.

  • NEW METHOD TO INSERT LARGE CALIBER PLASTIC AND SELF-EXPANDING METAL STENTS (SEMS) DURING BALLOON OVERTUBE ENTEROSCOPY (BAE) ASSISTED ERCP

    by Kröner, A Martínez-Alcalá García, G Schwingel, Am Ahmed, Ma D'Assunção, Lc Fry, K Mönkemüller

    Aims: To demonstrate a new method to deliver self-expanding metal and large diameter plastic stents during DBE-ERCP in patients with surgically altered upper GI tract anatomy. Methods: Retrospective, observational, cohort study at a single tertiary, academic institution during a 3-year period evaluating patients with complex post-surgical anatomy and undergoing BAE-ERCP. We focused on a new technique of BAE ERCP, which allowed for the insertion of large bore plastic stents and SEMS, which is impossible when using the standard enteroscope, as its working channel is only 2,8 to 3,2 mm in diameter. SEMS and 10 Fr plastic stents require working channels larger than 3,2 mm. Results: We performed a total of 105 BAE-ERCPs in 90 patients. The BAE-ERCP rendezvous and overtube-in-situ technique was utilized 10 times in 8 patients (8,8%, female n = 4, male n = 4, mean age 54.4, range 22 – 82). Indications were cholangitis n = 4, choledocolithaisis n = 6, cancer obstructing the hepaticojejunostomy (HJ) n = 2. The post-surgical anatomy was Roux-en-Y HJ n = 5, RY gastric bypass n = 1, Billroth II n = 1. Four patients had undergone a liver transplant, three patients had undergone Whipple's operation for pancreatic cancer, one patient had undergone RY hepaticojejunostomy for a choledocal cyst during childhood. The technique was successful in all patients. In 50% patients other interventions such direct cholangioscopy, dilation and EHL could be performed using this new technique. The mean duration of the procedure was 65 minutes, range 45 to 125 min. There were no major adverse events. Conclusions: The insertion of metal stents using this modified BAE-ERCP technique was feasible and successful, thus increasing our therapeutic capabilities in patients with complex post-surgical upper GI anatomy and biliary problems.

  • NOVEL TECHNIQUE FOR DIRECT PERCUTANEOUS ENDOSCOPIC JEJUNOSTOMY TUBE PLACEMENT USING SINGLE BALLOON ENTEROSCOPY WITH FLUOROSCOPY IN PATIENTS WITH SURGICALLY ALTERED UPPER GI TRACT ANATOMY

    by A Martínez-Alcalá García, T Kroner, Jp Gutierrez, I Jovanovic, M D'Assunção, L Fry, K Mönkemüller

    Direct percutaneous endoscopic jejunostomy (DPEJ) is a useful method to deliver nutrition in patients with a variety of problems such as: malignancies causing gastric outlet obstruction, gastroparesis, pancreatitis, high risk of aspiration and malnutrition, malnutrition in the setting of prior complex post-upper GI tract surgery such as gastric resection or Roux-en-Y gastric bypass. DPEJ using standard colonoscopes or push technique remains a technically challenging procedure, with success rates in expert hands being around 68%. Hereby we present the key steps to successfully conduct a DPEJ using single balloon enteroscopy technique. This new method of DPEJ placement focuses on three key components: In sum, we believe that the combination of all these aspects may increase the safety and success of this technique.

  • Evaluierung der neuen Optical Enhancement (OE) Technologie bei Patienten mit gastroösophagealer Refluxerkrankung

    by H Neumann, M Vieth, L Fry, S Löffler, C Günther, K Mönkemüller

    Einleitung: Optical Enhancement (OE) ist eine neue, nicht-invasive optische Chromoendoskopietechnik, die ähnlich dem etablierten NBI System vor allem Gefäßstrukturen besser zur Darstellung kommen lässt. Dies ist die erste Studie zur Evaluierung des OE-Systems für die Diagnose der gastroösophagealen Refluxerkrankung (GERD). Ziele: Evaluierung des neuen OE-Systems zur Verbesserung der Diagnose der GERD im Vergleich zur konventionellen High-Definition Weißlichtendoskopie. Material & Methoden: Patienten mit gesicherter Diagnose einer GERD und Kontrollpatienten ohne GERD wurden prospektiv untersucht. Die Patienten wurden gebeten einen validierten GERD Fragebogen (Reflux Disease Questionaire, RDQ) auszufüllen. Der Bereich des distalen Ösophagus wurde sorgfältig mit High-Definition Weißlichtendoskopie sowie der OE Technologie untersucht, anschließend wurden Biopsien entnommen. Die nur unter OE sichtbaren Veränderungen wurden abschließend zwischen dem Kontrollkollektiv und Patienten mit GERD verglichen. Ergebnisse: Insgesamt wurden 100 Areale gezielt untersucht. Bei 56% der Patienten wurde anhand klinischer und histologischer Befunde die Diagnose einer GERD gestellt. Das mediane Alter des Patientenkollektivs betrug 53 Jahre (Range 27 – 89 Jahre) und 60% der Patienten waren Frauen. Im Vergleich zum Kontrollkollektiv wiesen Patienten mit GERD signifikant häufiger unregelmäßig verlaufende (p = 0,042), dilatierte (p = 0,0003) und vermehrte (p = 0,001) Intrapapillary Capillary Loops (IPCLs) auf. Zusätzlich zeigten sich eine verstärkte Vaskularisierung und sogenannte Mucosal Breaks (p < 0,05). Bei der multivariaten Analyse waren eine erhöhte Anzahl und dilatierte IPCLs die besten Vorhersageparameter für das Vorliegen einer GERD. Schlussfolgerung: Das neue OE System verbessert signifikant die Diagnose der GERD im Vergleich zur konventionellen High-Definition Weißlichtendoskopie. Diese Ergebnisse sollten nun in einer multizentrischen Studie bestätigt werden.

  • Development and validation of a simple classification system for in vivo diagnosis of colorectal polyps using the newly introduced Optical Enhancement (OE) technology

    by H Neumann, H Albrecht, S Löffler, M Vieth, T Rath, L Fry, G Tontini, C Günther, K Mönkemüller

    Introduction: Most recently, Optical enhancement (OE) has been introduced as a novel endoscopic imaging technique that adjusts emitted light to enhance mucosal vascular pattern and surface pattern morphology. This study assessed for the first time the utility of OE to predict colorectal polyp histology. Aims: Primary objective was the development and validation of a simple classification system allowing differentiation of hyperplasic and adenomatous colorectal lesions by using OE. Material and methods: In the first phase, the capacity of experienced endoscopists to predict the histology of colorectal polyps was assessed. In the second phase, a simplified classification system was developed allowing histologic prediction of colorectal polyps. Thirdly, the validity of the classification was evaluated among inexperienced raters, including medical students, nurses and GI fellows. At least, a pilot clinical evaluation was performed during real-time colonoscopy. Results: A simple classification system for differentiation of hyperplasic and adenomatous colorectal lesions by using OE was developed and validated. Diagnosis was made in 85% of hyperplastic and 90% of adenomatous polyps with high-confidence. Sensitivity ranged from 92% to 96% and specificity ranged from 86% to 93%, respectively. During real-time colonoscopy, diagnosis was made with high-confidence in 90% of polyps with sensitivity of 96%, specificity of 92%, and accuracy of 95%. Positive and negative predictive values were 96% and 93%, respectively. Conclusion: For the first time a simple and effective classification system for differentiation of hyperplasic and adenomatous colorectal lesions by using the newly introduced OE-technology was developed and validated. These findings now need to be evaluated in future prospective, controlled, and blinded clinical trials.

  • Entwicklung und Validierung eines vereinfachten Klassifikationssystems zur in vivo Diagnose kolorektaler Polypen mit dem neuen Blue Light Imaging (BLI)

    by H Neumann, H Albrecht, S Löffler, M Vieth, L Fry, G Tontini, C Günther, K Mönkemüller

    Einleitung: BLI ist eine neue endoskopisch-bildgebende Technik, die zu einer besseren Farbkontrastierung während der endoskopischen Untersuchung führt und damit die Charakterisierung von umschriebenen Läsionen und Gefäßstrukturen vereinfachen soll. Dies ist die erste Studie zur Erfassung der Wertigkeit der neuen Technologie zur Vorhersage des histologischen Befundes von kolorektalen Polypen. Ziele: Primäres Studienziel war die Entwicklung einer vereinfachten Klassifikation für die in vivo Differenzierung von hyperplastischen und adenomatösen kolorektalen Läsionen unter Verwendung der neuen BLI Technologie. Sekundäres Studienziel war die Validierung der Klassifikation bei erfahrenen sowie unerfahrenen Untersuchern. Material & Methoden: Zunächst wurde die Möglichkeit erfahrener Untersucher zur Vorhersage der Histologie erfasst. Auf diesen Ergebnissen aufbauend wurde eine Klassifikation entwickelt, welche die Vorhersage des histologischen Befundes kolorektaler Läsionen ermöglichen sollte. Schließlich wurde die neue Klassifikation bei unerfahrenen Untersuchern, einschließlich Medizinstudenten, untersucht. Abschließend erfolgte eine erste klinische Evaluation der neuen Klassifikation während der endoskopischen Untersuchung. Ergebnisse: Es wurde ein vereinfachtes Klassifikationssystem zur Differenzierung hyperplastischer und adenomatöser kolorektaler Läsionen unter Verwendung der neuen BLI Technologie entwickelt und validiert. Eine sogenannte „high-confidence“ Diagnose wurde bei 80% der hyperplastischen und 88% der adenomatösen Polypen gestellt. Die Sensitivität und Spezifität lag bei jeweils 93%-100% bzw. bei 83%-92%. Während der klinischen Evaluation wurde die Diagnose in 88% der Polypen mit high-confidence gestellt und mit Sensitivitäten und Spezifitäten von jeweils 96% und 92%. Der positive Vorhersagewert betrug 96%, der negative Vorhersagewert 92%. Zusammenfassung: Die ist die erste Studie welche das neue BLI System zur Vorhersage der Polypenhistologie evaluierte. Die neu entwickelte Klassifikation erlaubt eine ausreichende Vorhersage der Polypenhistologie entsprechend den Empfehlungen der Fachgesellschaften. Zukünftige, prospektive Multizenterstudien sollten diese Ergebnisse nun weiter validieren.