YYYong Yu

Yong Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yong Yu has a total of 65 co-authors. Here are the top co-authors by number of shared publications:

  • Zheng-Hong Tang

    Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030, China

    5 shared publications
  • Hao Luo

    Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030, China

    4 shared publications
  • Jian-Hai Zhao

    Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030, China

    3 shared publications
  • Jing Yang

    Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030, China

    3 shared publications
  • Zheng-Jun Shang

    Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030, China

    3 shared publications
  • Zhenghong Tang

    Shanghai Astronomical Observatory, , Shanghai, China

    3 shared publications

Latest Publications

  • Enhancing Astrometric Registration of Chinese Historical Astronomical Digital Plates with Deep Learning

    by Quanfeng Xu, Mei-Ting Yang, Shiyin Shen, Zheng-Jun Shang, Yong Yu, Hao Luo, Zheng-Hong Tang, Jing Yang, Jian-Hai Zhao

    China has systematically collected nighttime astronomical plates since 1900, creating a large historical dataset that has been digitized with optical scanners. For astrometric registration of these digitized plates, sources were first extracted using SExtractor, and then matched astrometrically with Astrometry.net and the Gaia catalog. However, suboptimal early storage conditions and subsequent environmental deterioration have impeded accurate source matching, resulting in processing failures for several thousand digitized plates. In this work, we introduce a Transformer-based classification model that takes cutouts of SExtractor-detected sources as input and leverages multi-scale feature fusion to identify trustworthy stellar sources on the plates. Trained on plates with successful astrometric calibration, our AI-based classifier was then applied to SExtractor detected sources of 1883 digitized plates, enabling us to complete the astrometric registration for 1353 of them. This AI-augmented pipeline streamlines the processing of historical plate archives and enhances their scientific value for long-term time-domain astronomical studies.


  • Open Access

    Observations of Five Major Uranian Satellites during 2013–2020 Based on Gaia DR3

    by H. Y. Zhang, Y. Yu, R. C. Qiao, D. Yan, X. Cheng, K. Tang, Y. D. Mao

    A total of 10,339 positions of the five major Uranian satellites (Ariel, Umbriel, Titania, Oberon and Miranda) were collected at the Yunnan Observatories from 2013 to 2020 with the 1.0 m astrometric reflector. A median filtering method was applied to reduce the influence of the bright Uranus halo. All CCD observational data was analyzed by the newly developed CCD image-processing software with Gaia DR3 as the reference catalog. The impact of different exposure times on satellite positioning accuracy was evaluated. The observational positions of satellites were compared with theoretical positions from Institut de Mécanique Céleste et de Calcul des Éphémérides (DE441 and Lainey et al. 2015) and the mean offsets are from −0.″115 to 0.″103 in both R.A. and decl. for the five satellites. The standard deviation of the offsets are from 0.″008 to 0.″086 for the four greatest Uranian satellites and from 0.″037 to 0.″132 for Miranda in each direction. These precise observations of the five major Uranian satellites over an 8 yr period will be very useful for improving the orbital parameters of both Uranus and its five major satellites.


  • Open Access

    Digitization of Astronomical Photographic Plate of China and Astrometric Measurement of Single-exposure Plates

    by Zheng-Jun Shang, Yong Yu, Liang-Liang Wang, Mei-Ting Yang, Jing Yang, Shi-Yin Shen, Min Liu, Quan-Feng Xu, Chen-Zhou Cui, Dong-Wei Fan, et al.

    From the mid-19th century to the end of the 20th century, photographic plates served as the primary detectors for astronomical observations. Astronomical photographic observations in China began in 1901, and over a century, a total of approximately 30,000 astronomical photographic plates have been captured. These historical plates play an irreplaceable role in conducting long-term, time-domain astronomical research. To preserve and explore these valuable original astronomical observational data, Shanghai Astronomical Observatory has organized the transportation of plates taken at night from various stations across the country to the Sheshan Plate Archive for centralized preservation. For the first time, plate information statistics was performed. On this basis, the plates were cleaned and digitally scanned, and finally digitized images were acquired for 29,314 plates. In this study, using Gaia DR2 as the reference star catalog, astrometric processing has been carried out successfully on 15,696 single-exposure plates, including object extraction, stellar identification, and plate model computation. As a result, for long focal length telescopes, such as the 40cm double-tube refractor telescope and the 1.56m reflector telescope at the Shanghai Astronomical Observatory and the 1m reflector telescope at the Yunnan Astronomical Observatory, the astrometric accuracy obtained for their plates is approximately 0.1" to 0.3". The distribution of astrometric accuracy for medium and short focal length telescopes ranges from 0.3" to 1.0". The relevant data of this batch of plates, including digitized images and stellar catalog of the plates are archived and released by the National Astronomical Data Center. Users can access and download plate data based on keywords such as station, telescope, observation year, and observed celestial coordinates.

  • Open Access

    Evaluation of the astrometric capability of Multi-Channel Imager and simulated calculation of proper motion of M31

    by Wenfeng Fang, Yong Yu, Xiyan Peng, Zhaojun Yan, Yanzhen Hao, Huanyuan Shan, Zhaoxiang Qi, Shilong Liao, Zhenghong Tang, Qiqi Wu, et al.

    Introduction: The Multi-Channel Imager (MCI), one of the back-end modules of the future China Space Station Telescope (CSST), is designed for high-precision spacebased astronomical observations. This paper evaluates the astrometric capability of the MCI based on simulated observational images and Gaia data: the M31 galaxy is selected as a representative case to validate the astrometric capability by calculating the proper motions (PMs) of the M31 member stars.Method: We analyze the stellar centroids of the simulated images in the R, I and G bands, positional uncertainty of 2.5 mas for brighter foreground reference stars from the Gaia DR3 catalog and of 7.5 mas for the fainter M31 member stars, are adopted respectively. The theoretical PMs are generated from the adopted velocity field model, rotation curve, and stellar surface density profile. And the simulated observed PMs are generated from the aforementioned position uncertainties and theoretical PMs.Result: We conclude that the precision of the MCI derived PMs strongly depends on the number of astrometric epochs per year. Specifically, uncertainty of 10 μas/yr is achievable with 10 epochs per year, and of 5 μas/yr with 50 epochs ignoring possible systematic effects. And symmetrically distributed observed fields yield better M31 kinematic parameters.Discussion: Unknown systematic errors, space environment effects on detectors, dithering strategies, and observation schedules can affect the PMs of M31, the above issues need further analysis and validation in future work.


  • Open Access

    Development and application of high-precision multifunction astronomical plate digitizers in China

    by Meiting Yang, Yong Yu, Liangliang Wang, Zhengjun Shang, Changshun Liu, Lixin Zheng, Zhendong Chen, Jing Yang, Dongmei Da, Shan Dong, et al.

    Before charge-coupled device detectors became widely employed in observational astronomy, for more than a hundred years, the main detection method was photography on astronomical glass plates. Recently, in order to preserve these historical data and maintain their usability, the International Astronomical Union has appealed to all countries for global digitization of astronomical plates by developing or adopting advanced digitization technology. Specialized digitizers with high precision and high measuring speed represent key equipment for this task. The Shanghai Astronomical Observatory and the Nishimura Co., Ltd in Japan cooperated between 2013 and 2016 to develop the first Chinese high-precision astronomical plate digitizer, which was then used for complete digitization of all nighttime-observation astronomical plates in China. Then, in 2019-2021, the Shanghai Astronomical Observatory independently developed new models of plate digitizers that enabled countries such as Uzbekistan and Italy to digitize their astronomical plates. Additionally, a new high-precision and multifunction digitizer was also used to digitize valuable microscope slides from the Shanghai Natural History Museum, providing a successful example of crossdomain application of high-precision digitization technology.


  • Open Access

    Image Degradation Model for Dynamic Star Maps in Multiple Scenarios

    by Haima Yang, Yan Jin, Yinan Hu, Dawei Zhang, Yong Yu, Jin Liu, Jun Li, Xiaohui Jiang, Xiaojun Yu

    To meet the ground test requirements of star sensors, we establish the star map simulation algorithm and the interactive interface in multiple scenarios. The combination of the degradation model of star points, the imaging noise model, and the attitude disturbance model is introduced to solve the problem of different patterns of noise existing in the actual measurement, improving the traditional simulation model. In addition, a user-friendly interface design makes it easier for both scholars and average individuals to understand the parameters and then generate static single-frame star maps—or a series of dynamic sequence star maps—under various conditions. The results of the proposed star map simulation method are highly comparable to the actual captured star images, and this method can be applied for the tests and calibrations of star sensors.


  • Precise Positions of Triton in 2010–2014 based on Gaia-DR2

    by Huiyan Zhang, Yong Yu, Dan Yan, Kai Tang, Rongchuan Qiao

    With unique orbital and physical characteristics, Triton is a very important target because it may contain information of the origin and evolution of the solar system. Besides space explorations, ground-based observations over long time also play a key role on research of Triton. High-precision positions of Triton obtained from ground telescopes are of great significance for studying its orbital evolution and the physical properties of Neptune. As a long-term observational target, Triton has been observed by the 1.56 m telescope of Shanghai Astronomical Observatory since 1996. In this paper, based on our AAPPDI software and with Gaia DR2 as the reference catalog, 604 positions of Triton during 2010–2014 are calculated, with standard errors of 19–88 mas. A comparison between our results and the ephemeris (DE431+nep096) is also given.


  • Orbit Determination for Geostationary Earth Orbit Targets Based on the CCD Drift-scan Photoelectric Telescope at One Single Stationormalsize

    by Yong Yu, Hao Luo, Yindun Mao, Xiaofen Zhao, Zhenghong Tang

    地基光电观测在同步轨道目标监测领域具有重要作用.为评估单站光电设备对同步轨道目标的实际测定轨能力,利用上海天文台佘山站1.56m望远镜,采用CCD漂移扫描光电技术,对3颗北斗同步卫星开展试验观测,基于卫星精密星历评估目标的测定轨外符精度.结果表明:同步轨道目标的天文定位在方位和俯仰方向上的外符精度均好于0.3";在单圈次观测情况下,尽管轨道预报精度较低,约为数千米量级,但是观测弧段内定轨精度可优于百米;在多圈次观测情况下,轨道改进效果显著,定轨精度优于50m,外推至4d的轨道预报精度为百米量级.此外,定量评估了每晚不同观测时间跨度下同步轨道目标的测定轨精度,为单站光电设备实际应用提供了参考.


  • Digitizer of astronomical plates at Shanghai Astronomical Observatory and its performance test

    by Yong Yu, Jian-Hai Zhao, Zheng-Hong Tang, Zheng-Jun Shang

    Before CCD detectors were widely employed in observational astronomy, the main method of detection was the use of glass astrophotographic plates. Astronomical plates have been used to record information on the position and activity of celestial bodies for more than 100 years. There are about 30 000 astronomical plates in China, and the digitization of astronomical plates is of great significance for permanent preservation and to make full use of these valuable observation data. A digitizer with high precision and high measuring speed is a key piece of equipment for carrying out the task of digitizing these astronomical plates. A digitizer for glass astrophotographic plates was developed jointly by Shanghai Astronomical Observatory and Nishimura Co., Ltd of Japan. The digitizer’s hardware was manufactured by Nishimura Co., Ltd, and the performance test, error corrections as well as image processing of the digitizer were carried out by Shanghai Astronomical Observatory. The main structure and working mode of the digitizer are introduced in this paper. A performance test shows that brightness uniformity of illumination within the measuring area is better than 0.15%, the repeatability of digitized positions is better than 0.2 µm and the repeatability of digitized brightness is better than 0.01 instrumental magnitude. The systematic factors affecting digitized positions, such as lens distortion, the actual optical resolution, non-linearity of guide rails, non-uniformity of linear motors in the mobile platform, deviation of the image mosaic, and non-orthogonality between the direction of scanning and camera linear array, are calibrated and evaluated. Based on an astronomical plate with a size of 300mm × 300mm, which was digitized at different angles, the conversion residuals of positions of common stars on different images were investigated. The results show that the standard deviations of the residuals are better than 0.9 µm and the residual distribution is almost random, which demonstrates the digitizer has a higher precision for digitization.


  • Differential measurement of atmospheric refraction using a telescope with double fields of view

    by Yong Yu, Jian-Jun Cao, Zheng-Hong Tang, Hao Luo, Ming Zhao

    For the sake of advancing theoretical research about atmospheric refraction, the atmospheric refraction observed at lower angles of elevation is still worth analyzing and exploring. In some engineering applications, objects with a larger zenith distance must sometimes be observed. Carrying out observational research on atmospheric refraction at lower angles of elevation has an important significance. However, it has been considered difficult to measure the atmospheric refraction at lower angles of elevation. A new idea for determining atmospheric refraction by utilizing differential measurement with double fields of view is proposed. Taking the observational principle used by the HIPPARCOS satellite as a reference, a prototype with double fields of view was developed. In August 2013, experimental observations were carried out and atmospheric refractions at lower angles of elevation were obtained by the prototype. The measured value of atmospheric refraction at a zenith distance of 78.8° was 240.23'' ± 0.27'', and the feasibility of differential measurement of atmospheric refraction with double fields of view was verified. Limitations of the prototype, such as inadequate ability to gather light, lack of accurate meteorological data recording, and a low level of automation in observation and data processing, are pointed out, which need to be improved in subsequent work.