Kristan P. Gurton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kristan P. Gurton has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
David Ligon
U.S. Army Research Laboratory
5 shared publicationsRachid Dahmani
New Mexico State University
5 shared publicationsMelvin Felton
4 shared publicationsBurt V. Bronk
B. V. Bronk is with the U.S. Air Force Research Laboratory at SBCCOM, Edgewood Chemical Biological Center, Aberdeen Proving Grounds, Maryland 21010-5424
1 shared publicationDennis Volpano
1 shared publicationGary Moore
1 shared publication
Latest Publications
- 1 March 2013
- Published by Defense Technical Information Center (DTIC)
Detection of Bioaerosols using Single Particle Thermal Emission Spectroscopy
This report documents current finding for an ongoing study designed to assess the ability to measure in situ the absorption spectra from a single bio-aerosol particle. In particular, we describe experimental method(s) and techniques capable of detecting the single particle thermal emission in the infrared (IR) spectral range from 3 to 12 microns. We report current findings to accurately measure the graybody spectral emission from a 1-20 micron-size bioparticle when heated to temperatures in excess of a 100 deg C. Prevailing theory suggests a strong link between thermal emission and absorption spectra for bulk materials held at elevated temperatures. This study (1) establishes whether it is possible to measure and spectrally resolve the thermal emission from a small optically heated aerosol-type particle, and (2) determines the functional relationship(s) that couple the measured thermal emission with actual absorption.
- 1 March 2013
- Published by Defense Technical Information Center (DTIC)
Detection of Bioaerosols using Single Particle Thermal Emission Spectroscopy
This report documents current finding for an ongoing study designed to assess the ability to measure in situ the absorption spectra from a single bio-aerosol particle. In particular, we describe experimental method(s) and techniques capable of detecting the single particle thermal emission in the infrared (IR) spectral range from 3 to 12 microns. We report current findings to accurately measure the graybody spectral emission from a 1-20 micron-size bioparticle when heated to temperatures in excess of a 100 deg C. Prevailing theory suggests a strong link between thermal emission and absorption spectra for bulk materials held at elevated temperatures. This study (1) establishes whether it is possible to measure and spectrally resolve the thermal emission from a small optically heated aerosol-type particle, and (2) determines the functional relationship(s) that couple the measured thermal emission with actual absorption.
- 1 September 2012
- Published by Defense Technical Information Center (DTIC)
Multi-wavelength Laser Photoacoustics
An optical detection method designed to detect and identify the presence of macro-molecular gas species (e.g., organophosphate-based nerve agent simulants) at trace level concentrations is presented. The technique is based on a modified version of conventional laser photoacoustic spectroscopy (LPAS) in which optical absorption is typically measured using a single laser source. We demonstrate the ability to simultaneously measure multiple absorption related parameters that serve as a concentration independent identifier. Three continuous wave (CW) mid-infrared (MidIR) laser sources, operating at 8.68, 9.29, and 10.35 micrometers are combined and propagated axially through a specially designed flow-through photoacoustic cell. Each laser is modulated at a different frequency and the resultant acoustic signal(s) are detected and deconvolved using a PC-based 24-bit dynamic signal acquisition device. Species detection and identification is achieved by tabulating independent ratios of the acoustic response for each laser source. Quantitative absorption measured is verified using a Fourier transform infrared (FTIR) spectrometer. Results show good detection and species separation/identification at moderately low ppm concentrations.
- 1 September 2012
- Published by Defense Technical Information Center (DTIC)
Multi-wavelength Laser Photoacoustics
An optical detection method designed to detect and identify the presence of macro-molecular gas species (e.g., organophosphate-based nerve agent simulants) at trace level concentrations is presented. The technique is based on a modified version of conventional laser photoacoustic spectroscopy (LPAS) in which optical absorption is typically measured using a single laser source. We demonstrate the ability to simultaneously measure multiple absorption related parameters that serve as a concentration independent identifier. Three continuous wave (CW) mid-infrared (MidIR) laser sources, operating at 8.68, 9.29, and 10.35 micrometers are combined and propagated axially through a specially designed flow-through photoacoustic cell. Each laser is modulated at a different frequency and the resultant acoustic signal(s) are detected and deconvolved using a PC-based 24-bit dynamic signal acquisition device. Species detection and identification is achieved by tabulating independent ratios of the acoustic response for each laser source. Quantitative absorption measured is verified using a Fourier transform infrared (FTIR) spectrometer. Results show good detection and species separation/identification at moderately low ppm concentrations.
- 24 August 2007
- Published by Optica Publishing Group in Applied Optics
- Vol. 46 (25) , 6323-6329
In situ infrared aerosol spectroscopy for a variety of nerve agent simulants using flow-through photoacoustics
We present newly measured results of an ongoing experimental program established to measure optical cross sections in the mid- and long-wave infrared for a variety of chemically and biologically based aerosols. For this study we consider only chemically derived aerosols, and in particular, a group of chemical compounds often used as simulants for the detection of extremely toxic organophosphorus nerve agents. These materials include: diethyl methylphosphonate (DEMP), dimethyl methylphosphonate (DMMP), diisopropyl methylphosphonate (DIMP), and diethyl phthalate (DEP). As reported in a prior study [Appl. Opt. 44, 4001 (2005)], we combine two optical techniques well suited for aerosol spectroscopy [i.e., flow-through photoacoustics and Fourier transform infrared (FTIR) emission spectroscopy], to measure in situ the absolute extinction and absorption cross sections over a variety of wavelengths spanning the IR spectral region from 3 to . Aerosol size distribution(s), particle number density, and dosimetric measurements are recorded simultaneously in order to present optical cross sections that are aerosol mass normalized, i.e., . Photoacoustic results, conducted at a series of laser lines, compare well with measured broadband FTIR spectral extinction. Both FTIR and photoacoustic data also compare well with Mie theory calculations based on measured size distributions and previously published complex indices of refraction.- 24 August 2007
- Published by Optica Publishing Group in Applied Optics
- Vol. 46 (25) , 6323-6329
In situ infrared aerosol spectroscopy for a variety of nerve agent simulants using flow-through photoacoustics
We present newly measured results of an ongoing experimental program established to measure optical cross sections in the mid- and long-wave infrared for a variety of chemically and biologically based aerosols. For this study we consider only chemically derived aerosols, and in particular, a group of chemical compounds often used as simulants for the detection of extremely toxic organophosphorus nerve agents. These materials include: diethyl methylphosphonate (DEMP), dimethyl methylphosphonate (DMMP), diisopropyl methylphosphonate (DIMP), and diethyl phthalate (DEP). As reported in a prior study [Appl. Opt. 44, 4001 (2005)], we combine two optical techniques well suited for aerosol spectroscopy [i.e., flow-through photoacoustics and Fourier transform infrared (FTIR) emission spectroscopy], to measure in situ the absolute extinction and absorption cross sections over a variety of wavelengths spanning the IR spectral region from 3 to . Aerosol size distribution(s), particle number density, and dosimetric measurements are recorded simultaneously in order to present optical cross sections that are aerosol mass normalized, i.e., . Photoacoustic results, conducted at a series of laser lines, compare well with measured broadband FTIR spectral extinction. Both FTIR and photoacoustic data also compare well with Mie theory calculations based on measured size distributions and previously published complex indices of refraction.- 10 September 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (26) , 5361-5367
Effect of surface roughness and complex indices of refraction on polarized thermal emission
We present a series of measurements characterizing the dependence of polarized thermal emission on surface roughness. In particular, we measure the spectrally resolved degree of linear polarization (DOLP) for a series of roughened borosilicate (Pyrex) glass substrates as a function of the roughness parameter Ra, the root-mean-square slope distribution, and observation angle θ. Also measured are a series of smooth glass substrates coated with two particular polymers of interest, i.e., a common commercially available Krylon paint and a chemical-agent-resistant coating paint. The DOLP is measured over a 4–13 μm wave band by using a modified Fourier transform IR spectrometer in which a wire-grid polarizer and a quarter-wave Fresnel rhomb are used in conjunction to measure all four Stokes parameters. In addition, we show an enhanced DOLP due to anomalous dispersion exhibited by the surface material.
- 10 September 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (26) , 5361-5367
Effect of surface roughness and complex indices of refraction on polarized thermal emission
We present a series of measurements characterizing the dependence of polarized thermal emission on surface roughness. In particular, we measure the spectrally resolved degree of linear polarization (DOLP) for a series of roughened borosilicate (Pyrex) glass substrates as a function of the roughness parameter Ra, the root-mean-square slope distribution, and observation angle θ. Also measured are a series of smooth glass substrates coated with two particular polymers of interest, i.e., a common commercially available Krylon paint and a chemical-agent-resistant coating paint. The DOLP is measured over a 4–13 μm wave band by using a modified Fourier transform IR spectrometer in which a wire-grid polarizer and a quarter-wave Fresnel rhomb are used in conjunction to measure all four Stokes parameters. In addition, we show an enhanced DOLP due to anomalous dispersion exhibited by the surface material.
- 1 July 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (19) , 4096-4101
In situ measurement of the infrared absorption and extinction of chemical and biologically derived aerosols using flow-through photoacoustics
In an effort to establish a more reliable set of optical cross sections for a variety of chemical and biological aerosol simulants, we have developed a flow-through photoacoustic system that is capable of measuring absolute, mass-normalized extinction and absorption cross sections. By employing a flow-through design we avoid issues associated with closed aerosol photoacoustic systems and improve sensitivity. Although the results shown here were obtained for the tunable CO2 laser waveband region, i.e., 9.20–10.80 µm, application to other wavelengths is easily achievable. The aerosols considered are categorized as biological, chemical, and inorganic in origin, i.e., Bacillus atrophaeus endospores, dimethicone silicone oil (SF-96 grade 50), and kaolin clay powder (alumina and silicate), respectively. Results compare well with spectral extinction measured previously by Fourier-transform infrared spectroscopy. Comparisons with Mie theory calculations based on previously published complex indices of refraction and measured size distributions are also presented.
- 1 July 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (19) , 4096-4101
In situ measurement of the infrared absorption and extinction of chemical and biologically derived aerosols using flow-through photoacoustics
In an effort to establish a more reliable set of optical cross sections for a variety of chemical and biological aerosol simulants, we have developed a flow-through photoacoustic system that is capable of measuring absolute, mass-normalized extinction and absorption cross sections. By employing a flow-through design we avoid issues associated with closed aerosol photoacoustic systems and improve sensitivity. Although the results shown here were obtained for the tunable CO2 laser waveband region, i.e., 9.20–10.80 µm, application to other wavelengths is easily achievable. The aerosols considered are categorized as biological, chemical, and inorganic in origin, i.e., Bacillus atrophaeus endospores, dimethicone silicone oil (SF-96 grade 50), and kaolin clay powder (alumina and silicate), respectively. Results compare well with spectral extinction measured previously by Fourier-transform infrared spectroscopy. Comparisons with Mie theory calculations based on previously published complex indices of refraction and measured size distributions are also presented.
- 10 August 2004
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (23) , 4564-4570
Measured infrared optical cross sections for a variety of chemical and biological aerosol simulants
We conducted a series of spectral extinction measurements on a variety of aerosolized chemical and biological simulants over the spectral range 3–13 μm using conventional Fourier-transform IR (FTIR) aerosol spectroscopy. Samples consist of both aerosolized particulates and atomized liquids. Materials considered include Bacillus subtilis endospores, lyophilized ovalbumin, polyethylene glycol, dimethicone (SF-96), and three common background materials: kaolin clay (hydrated aluminum silicate), Arizona road dust (primarily SiO2), and diesel soot. Aerosol size distributions and mass density were measured simultaneously with the FTIR spectra. As a result, all optical parameters presented here are mass normalized, i.e., in square meters per gram. In an effort to establish the utility of using Mie theory to predict such parameters, we conducted a series of calculations. For materials in which the complex indices of refraction are known, e.g., silicone oil (SF-96) and kaolin, measured size distributions were convolved with Mie theory and the resultant spectral extinction calculated. Where there was good agreement between measured and calculated extinction spectra, absorption, total scattering, and backscatter were also calculated.
- 10 August 2004
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (23) , 4564-4570
Measured infrared optical cross sections for a variety of chemical and biological aerosol simulants
We conducted a series of spectral extinction measurements on a variety of aerosolized chemical and biological simulants over the spectral range 3–13 μm using conventional Fourier-transform IR (FTIR) aerosol spectroscopy. Samples consist of both aerosolized particulates and atomized liquids. Materials considered include Bacillus subtilis endospores, lyophilized ovalbumin, polyethylene glycol, dimethicone (SF-96), and three common background materials: kaolin clay (hydrated aluminum silicate), Arizona road dust (primarily SiO2), and diesel soot. Aerosol size distributions and mass density were measured simultaneously with the FTIR spectra. As a result, all optical parameters presented here are mass normalized, i.e., in square meters per gram. In an effort to establish the utility of using Mie theory to predict such parameters, we conducted a series of calculations. For materials in which the complex indices of refraction are known, e.g., silicone oil (SF-96) and kaolin, measured size distributions were convolved with Mie theory and the resultant spectral extinction calculated. Where there was good agreement between measured and calculated extinction spectra, absorption, total scattering, and backscatter were also calculated.
- 1 June 2004
- Published by Defense Technical Information Center (DTIC)
Measured Degree of Infrared Polarization for a Variety of Thermal Emitting Surfaces
We report on a series of parametric measurements designed to measure the attenuative effects that surface roughness and aerosol contamination play in reducing polarized thermal surface emission. In particular, we measure the spectrally resolved linear degree of polarization (LDOP) for a series of roughened borosilicate (Pyrex trade mark) glass substrates as a function of roughness parameter, Ra, root mean square slope, m, and the angle of observation, theta. Spectrally resolved LDOP is measured over the waveband region 4 to 13 micrometers by a modified Fourier transform IR spectrometer in which a wire-grid polarizer and an achromatic quarter-wave plate are used in conjunction to measure all four Stokes parameters. A second set of measurements is conducted on similar smooth glass substrates that are subjected to varying degrees of dew formation and aerosol contamination. Test substrates are oriented at a high grazing angle of 80 degrees and placed in a closed chamber. Dew or attenuative particulates, i.e., carbon black, potassium bromide, or pollen particles, are allowed to condense/settle on the thermal emitting surface while a band-averaged LDOP is recorded with a long-wave polarimetric IR imaging system. Measured results are then compared with predictive calculations based on a weighted Fresnel relation.
- 1 June 2004
- Published by Defense Technical Information Center (DTIC)
Measured Degree of Infrared Polarization for a Variety of Thermal Emitting Surfaces
We report on a series of parametric measurements designed to measure the attenuative effects that surface roughness and aerosol contamination play in reducing polarized thermal surface emission. In particular, we measure the spectrally resolved linear degree of polarization (LDOP) for a series of roughened borosilicate (Pyrex trade mark) glass substrates as a function of roughness parameter, Ra, root mean square slope, m, and the angle of observation, theta. Spectrally resolved LDOP is measured over the waveband region 4 to 13 micrometers by a modified Fourier transform IR spectrometer in which a wire-grid polarizer and an achromatic quarter-wave plate are used in conjunction to measure all four Stokes parameters. A second set of measurements is conducted on similar smooth glass substrates that are subjected to varying degrees of dew formation and aerosol contamination. Test substrates are oriented at a high grazing angle of 80 degrees and placed in a closed chamber. Dew or attenuative particulates, i.e., carbon black, potassium bromide, or pollen particles, are allowed to condense/settle on the thermal emitting surface while a band-averaged LDOP is recorded with a long-wave polarimetric IR imaging system. Measured results are then compared with predictive calculations based on a weighted Fresnel relation.
- 1 September 2003
- Published by Defense Technical Information Center (DTIC)
In Situ Measurement of the Infrared Spectral Extinction for Various Chemical, Biological, and Background Aerosols
We conducted a series spectral extinction measurements on a variety of aerosolized chemical and biological simulants over the spectral range 3-13 microns using conventional Fourier transform infrared (FTIR) aerosol spectroscopy. Samples consist of both aerosolized particulates and atomized liquids. Materials considered include Bacillus Subtilis endospores (BG), lyophilized ovalbumin, polyethylene glycol (PEG), dimethicone (SF-96 grade 50), and three common background materials (Kaolin clay HYDRATED ALUMINUM SILICATEL, Arizona road dust PRIMARILY SiO2, and diesel soot). Aerosol size distributions and mass density were measured simultaneously with the FTIR spectra. As a result all optical parameters presented here are mass-normalized, i.e., (m2/g).
- 1 September 2003
- Published by Defense Technical Information Center (DTIC)
In Situ Measurement of the Infrared Spectral Extinction for Various Chemical, Biological, and Background Aerosols
We conducted a series spectral extinction measurements on a variety of aerosolized chemical and biological simulants over the spectral range 3-13 microns using conventional Fourier transform infrared (FTIR) aerosol spectroscopy. Samples consist of both aerosolized particulates and atomized liquids. Materials considered include Bacillus Subtilis endospores (BG), lyophilized ovalbumin, polyethylene glycol (PEG), dimethicone (SF-96 grade 50), and three common background materials (Kaolin clay HYDRATED ALUMINUM SILICATEL, Arizona road dust PRIMARILY SiO2, and diesel soot). Aerosol size distributions and mass density were measured simultaneously with the FTIR spectra. As a result all optical parameters presented here are mass-normalized, i.e., (m2/g).
- 1 December 1997
- Published by Defense Technical Information Center (DTIC)
1997 Summer Research Program (SRP), Summer Research Extension Program (SREP), Final Report, Volume 5. Arnold Engineering Center, Air Logistics Centers, United States Air Force Academy, Wilford Hall Medical Center
Spectral extinction was measured in situ for aerosolized Bacillus subtilis var. niger (BC) endospores with the use of Fourier-transform infrared (FTIR) spectroscopy from 3.0 to 13.0 micrometers. Corresponding aerosol-size distributions were measured with the use of a commercially available elastic light-scattering probe and verified by direct particle capture and subsequent counting via video microscopy. Aerosol mass density was monitored simultaneously with conventional dosimetry and used to mass-normalize the measured spectral extinction. Mie theory calculations based on measured distributions and available complex indices of refraction agreed well. Also present are resultant Mie calculations for the absorption, total scattering, and backscattering. Included are the real and imaginary components of the complex index of refraction for BC as measured by Milham and Quarry. Both calculated and measured cross sections suggest that for wavelengths longer than 6.0 micrometers, the total extinction is primarily due to absorption. Finally, to offer a comparison, we present measured spectral extinction for three additional aerosols often found in the lower atmosphere, i.e., water fog, diesel soot, and Arizona road dust.
- 1 December 1997
- Published by Defense Technical Information Center (DTIC)
1997 Summer Research Program (SRP), Summer Research Extension Program (SREP), Final Report, Volume 5. Arnold Engineering Center, Air Logistics Centers, United States Air Force Academy, Wilford Hall Medical Center
Spectral extinction was measured in situ for aerosolized Bacillus subtilis var. niger (BC) endospores with the use of Fourier-transform infrared (FTIR) spectroscopy from 3.0 to 13.0 micrometers. Corresponding aerosol-size distributions were measured with the use of a commercially available elastic light-scattering probe and verified by direct particle capture and subsequent counting via video microscopy. Aerosol mass density was monitored simultaneously with conventional dosimetry and used to mass-normalize the measured spectral extinction. Mie theory calculations based on measured distributions and available complex indices of refraction agreed well. Also present are resultant Mie calculations for the absorption, total scattering, and backscattering. Included are the real and imaginary components of the complex index of refraction for BC as measured by Milham and Quarry. Both calculated and measured cross sections suggest that for wavelengths longer than 6.0 micrometers, the total extinction is primarily due to absorption. Finally, to offer a comparison, we present measured spectral extinction for three additional aerosols often found in the lower atmosphere, i.e., water fog, diesel soot, and Arizona road dust.
- Open Access
- 1 December 1996
- Published by Defense Technical Information Center (DTIC)
Provably-Secure Programming Languages for Remote Evaluation
We present radiometric and polarimetric calibrated imagery recorded in both the mid-wave infrared (IR) (MidIR) and long-wave IR (LWIR) as a function of diurnal variation over several multiday periods. We compare differences in polarimetric and conventional thermal imagery for both IR atmospheric transmission windows, i.e., the 3-5 mu and 8-12 mu regions. Meteorological parameters measured during the study include temperature, relative humidity, wind speed/direction, precipitation, and ambient atmospheric IR loading. The two camera systems used in the study differed significantly in design. The LWIR polarimetric sensor utilizes a spinning achromatic retarder and is best suited for static scenes, while the MidIR system is based on a division-of-aperture design and is capable of recording polarimetric imagery of targets that are rapidly moving. Examples of both So (conventional thermal) and degree-of-linear polarization (DOLP) imagery are presented and compared.
- 1 December 1996
- Published by Defense Technical Information Center (DTIC)
Open AccessProvably-Secure Programming Languages for Remote Evaluation
We present radiometric and polarimetric calibrated imagery recorded in both the mid-wave infrared (IR) (MidIR) and long-wave IR (LWIR) as a function of diurnal variation over several multiday periods. We compare differences in polarimetric and conventional thermal imagery for both IR atmospheric transmission windows, i.e., the 3-5 mu and 8-12 mu regions. Meteorological parameters measured during the study include temperature, relative humidity, wind speed/direction, precipitation, and ambient atmospheric IR loading. The two camera systems used in the study differed significantly in design. The LWIR polarimetric sensor utilizes a spinning achromatic retarder and is best suited for static scenes, while the MidIR system is based on a division-of-aperture design and is capable of recording polarimetric imagery of targets that are rapidly moving. Examples of both So (conventional thermal) and degree-of-linear polarization (DOLP) imagery are presented and compared.