Tomas Menovsky
Research Subjects
Tomas Menovsky has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Erik L. van Lindert
Neurosurgical Center Nijmegen, Nijmegen, The Netherlands
1 shared publicationJ. André Grotenhuis
Neurosurgical Center Nijmegen, Nijmegen, The Netherlands
1 shared publicationJohan F. Beek
1 shared publicationJoost De Vries
1 shared publication- Ronald H. M. A. Bartels
Department of Neurosurgery, Radboud University Medical Center, Nijmegen, the Netherlands
1 shared publication
Latest Publications
- 1 July 2004
- Published by World Scientific Pub Co Pte Ltd in Hand Surgery
- Vol. 09 (01) , 35-38
SKIN CLOSURE IN CARPAL TUNNEL SURGERY: A PROSPECTIVE COMPARATIVE STUDY BETWEEN NYLON, POLYGLACTIN 910 AND STAINLESS STEEL SUTURES
Objective: To compare the cosmetic outcome, pain and tenderness around the operation scar of carpal tunnel syndrome surgery using either nylon, polyglactin 910 or stainless steel sutures for skin closure. Methods: A randomised clinical trial comparing nylon, polyglactin 910 or stainless steel sutures for skin closure in 61 patients undergoing carpal tunnel syndrome surgery was performed. Pain, tenderness, scar hypertrophy, redness and the presence of granulomas were assessed in all patients at ten days and six weeks after surgery and compared by non-parametric statistical tests. Results: Adequate surgical decompression of the median nerve could be achieved in all patients. All but two patients experienced significant relief of tingling of the fingers. Nearly all patients reported some degree of discomfort around the scar. At ten days, the mean pain score was 1.7 (±2.2), 3.1 (±2.3) and 1.9 (±2.3) for the nylon, vicryl and steel groups, respectively. At six weeks, the pain score was 3.6 (±3.1), 3.4 (±2.6) and 2.7 (±2.1) for the nylon, vicryl and steel groups, respectively. The infection rate was 0%, 8% and 0% for the nylon, vicryl and steel groups, respectively. Suture granulomas were significantly more present in the vicryl group (pConclusions: Nylon and stainless steel sutures are both suitable for skin closure after carpal tunnel surgery. Based on this study, absorbable vicryl sutures should not be used, since the incidence of infections and the presence of suture granulomas was much higher than in the nylon and steel suture groups.
- 1 July 2004
- Published by World Scientific Pub Co Pte Ltd in Hand Surgery
- Vol. 09 (01) , 35-38
SKIN CLOSURE IN CARPAL TUNNEL SURGERY: A PROSPECTIVE COMPARATIVE STUDY BETWEEN NYLON, POLYGLACTIN 910 AND STAINLESS STEEL SUTURES
Objective: To compare the cosmetic outcome, pain and tenderness around the operation scar of carpal tunnel syndrome surgery using either nylon, polyglactin 910 or stainless steel sutures for skin closure. Methods: A randomised clinical trial comparing nylon, polyglactin 910 or stainless steel sutures for skin closure in 61 patients undergoing carpal tunnel syndrome surgery was performed. Pain, tenderness, scar hypertrophy, redness and the presence of granulomas were assessed in all patients at ten days and six weeks after surgery and compared by non-parametric statistical tests. Results: Adequate surgical decompression of the median nerve could be achieved in all patients. All but two patients experienced significant relief of tingling of the fingers. Nearly all patients reported some degree of discomfort around the scar. At ten days, the mean pain score was 1.7 (±2.2), 3.1 (±2.3) and 1.9 (±2.3) for the nylon, vicryl and steel groups, respectively. At six weeks, the pain score was 3.6 (±3.1), 3.4 (±2.6) and 2.7 (±2.1) for the nylon, vicryl and steel groups, respectively. The infection rate was 0%, 8% and 0% for the nylon, vicryl and steel groups, respectively. Suture granulomas were significantly more present in the vicryl group (pConclusions: Nylon and stainless steel sutures are both suitable for skin closure after carpal tunnel surgery. Based on this study, absorbable vicryl sutures should not be used, since the incidence of infections and the presence of suture granulomas was much higher than in the nylon and steel suture groups.
- 1 January 2004
- Published by Wiley in Microsurgery
- Vol. 24 (4) , 302-303
Atraumatic suction tip for microsurgery: Technical note
During microneurosurgery, frequent suction is essential for a successful operative course. A new self‐made disposable suction tip is described which facilitates atraumatic suction, even near vital anatomical structures. The efficacy of this suction tip was confirmed in selected operative procedures.
- 1 January 2004
- Published by Wiley in Microsurgery
- Vol. 24 (4) , 302-303
Atraumatic suction tip for microsurgery: Technical note
During microneurosurgery, frequent suction is essential for a successful operative course. A new self‐made disposable suction tip is described which facilitates atraumatic suction, even near vital anatomical structures. The efficacy of this suction tip was confirmed in selected operative procedures.
- 1 January 2003
- Published by Wiley in Microsurgery
- Vol. 23 (2) , 109-116
Carbon dioxide laser‐assisted nerve repair: Effect of solder and suture material on nerve regeneration in rat sciatic nerve
In order to further improve and explore the role of lasers for nerve reconstruction, this study was designed to investigate regeneration of sharply transected peripheral nerves repaired with a CO2 milliwatt laser in combination with three different suture materials and a bovine albumin protein solder as an adjunct to the welding process. Unilateral sciatic nerve repair was performed in 44 rats. In the laser group, nerves were gently apposed, and two stay sutures (10‐0 nylon, 10‐0 polyglycolic acid, or 25‐μm stainless steel) were placed epi/perineurially. Thereafter, the repair site was fused at 100 mW with pulses of 1.0 s. In the subgroup of laser‐assisted nerve repair (LANR), albumen was used as a soldering agent to further reinforce the repair site. The control group consisted of nerves repaired by conventional microsurgical suture repair (CMSR), using 4–6 10‐0 nylon sutures. Evaluation was performed at 1 and 6 weeks after surgery, and included qualitative and semiquantitative light microscopy. LANR performed with a protein solder results in a good early peripheral nerve regeneration, with an optimal alignment of nerve fibers and minimal connective tissue proliferation at the repair site. All three suture materials produced a foreign body reaction; the least severe was with polyglycolic acid sutures. CMSR resulted in more pronounced foreign‐body granulomas at the repair site, with more connective‐tissue proliferation and axonal misalignment. Furthermore, axonal regeneration in the distal nerve segment was better in the laser groups. Based on these results, CO2 laser‐assisted nerve repair with soldering in combination with absorbable sutures has the potential of allowing healing to occur with the least foreign‐body reaction at the repair site. Further experiments using this combination are in progress. © 2003 Wiley‐Liss, Inc. MICROSURGERY 23:109–116 2003
- 1 January 2003
- Published by Wiley in Microsurgery
- Vol. 23 (2) , 109-116
Carbon dioxide laser‐assisted nerve repair: Effect of solder and suture material on nerve regeneration in rat sciatic nerve
In order to further improve and explore the role of lasers for nerve reconstruction, this study was designed to investigate regeneration of sharply transected peripheral nerves repaired with a CO2 milliwatt laser in combination with three different suture materials and a bovine albumin protein solder as an adjunct to the welding process. Unilateral sciatic nerve repair was performed in 44 rats. In the laser group, nerves were gently apposed, and two stay sutures (10‐0 nylon, 10‐0 polyglycolic acid, or 25‐μm stainless steel) were placed epi/perineurially. Thereafter, the repair site was fused at 100 mW with pulses of 1.0 s. In the subgroup of laser‐assisted nerve repair (LANR), albumen was used as a soldering agent to further reinforce the repair site. The control group consisted of nerves repaired by conventional microsurgical suture repair (CMSR), using 4–6 10‐0 nylon sutures. Evaluation was performed at 1 and 6 weeks after surgery, and included qualitative and semiquantitative light microscopy. LANR performed with a protein solder results in a good early peripheral nerve regeneration, with an optimal alignment of nerve fibers and minimal connective tissue proliferation at the repair site. All three suture materials produced a foreign body reaction; the least severe was with polyglycolic acid sutures. CMSR resulted in more pronounced foreign‐body granulomas at the repair site, with more connective‐tissue proliferation and axonal misalignment. Furthermore, axonal regeneration in the distal nerve segment was better in the laser groups. Based on these results, CO2 laser‐assisted nerve repair with soldering in combination with absorbable sutures has the potential of allowing healing to occur with the least foreign‐body reaction at the repair site. Further experiments using this combination are in progress. © 2003 Wiley‐Liss, Inc. MICROSURGERY 23:109–116 2003