RJR. L. Jaarsma

R. L. Jaarsma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


R. L. Jaarsma has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • A. van Kampen

    Department of Orthopedic Surgery, University Medical Centre Nijmegen, Nijmegen, The Netherlands

    2 shared publications
  • A Van Kampen

    1 shared publication
  • A. W. A. Bruggeman

    Department of Radiology, University Medical Centre Nijmegen, Nijmegen, The Netherlands

    1 shared publication
  • B.F. Ongkiehong

    Department of Orthopaedics, University Medical Centre St. Radboud, PO Box 9101, 6500 HB Nijmegen, The Netherlands

    1 shared publication
  • C. Grüneberg

    Department of Medical Physics and Biophysics, University Medical Centre St. Radboud, Nijmegen, The Netherlands

    1 shared publication
  • D F M Pakvis

    1 shared publication

Latest Publications

  • Computed tomography determined femoral torsion is not accurate

    by R. L. Jaarsma, A. W. A. Bruggeman, D. F. M. Pakvis, N. Verdonschot, J. A. M. Lemmens, A. van Kampen

    Introduction Computed tomography (CT) is considered the method of choice for detecting rotational malalignment of the femur. However, it is unclear how reliable the method is, and what the causes are of potential inaccuracies. Materials and methods To address these issues three observers measured the CT images of the femur of 76 patients on two separate occasions. The images were made during follow-up of a unilateral femoral shaft fractures. Rotational malalignment was determined by comparing the torsion angle of the injured to the noninjured leg. Results The pooled intraobserver variance was 3.9° and interobserver variance 4.1°. Of the two measurements of one observer 95% were up to 10.8° different, and between observers 95% of the measurements were up to 15.6° different. Conclusions CT measurements of rotational malalignment of the femur are not accurate. This is due principally to the difficulty in defining a line through the axis of the femoral neck. The accuracy can be improved by taking the average of two measurements.


    • 8 March 2003
      • Vol. 147  (10) , 443-6

    [Limb-length measurements using wooden boards: an accurate and experience-independent method].

    by D F M Pakvis, R L Jaarsma, A Van Kampen

    To determine the precision and reliability of the indirect limb-length measurement, and the inter-observer variance between doctors differing in level of experience. Descriptive. Indirect limb-length measurement by placing 0.5 cm-thick wooden boards under the foot of the shorter leg until the difference in length was corrected, was performed by 3 observers differing in experience (medical student, resident and orthopaedic surgeon) on 66 patients with unilateral femoral-shaft fractures treated with a femoral nail. The group of patients consisted of 51 men and 15 women with a median age of 30 years (range: 18-90). In total 17 observers participated and 177 limb-length measurements were performed. The measurements obtained were compared with limb-length measurements obtained by orthoradiograms of the entire leg. Of the 177 indirect limb-length measurements, 144 (81%) differed by 0-1.0 cm compared with the limb length obtained by orthoradiogram. There was no statistically significant difference in the limb-length measurements obtained by the three groups of observers with different experience levels. There was a certain degree of correlation between values measured by medical students and residents (r = 0.7). When comparing the measurements carried out by staff members with those of residents and medical students, respectively, a lower degree of correlation was found (r = 0.6 and 0.5, respectively). Indirect limb-length measurement with wooden boards was accurate. Experience did not play an essential role.