Alexander Ioffe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander Ioffe has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Earl Babcock
Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS) at Heinz Maier-Leibnitz Zentrum (MLZ), 85747 Garching, Germany
6 shared publications M. Vrana
Nuclear Physics Institute of CAS, 25068 Řež, near Prague, Czech Republic CZ
4 shared publications- Thomas Brückel
Forschungszentrum Jülich
4 shared publications Klaus Bussmann
Jülich Centre for Neutron Science (JCNS) and Peter Grünberg Institut (PGI), JARA-FIT Forschungszentrum Jülich GmbH, 52425 Jülich, Germany
3 shared publicationsSergey Manoshin
Hahn-Meitner-Institute, Glienickerst. 100, 14109 Berlin, Germany
3 shared publications- Artem Feoktystov
Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science JCNS at Heinz Maier-Leibnitz Zentrum MLZ, 85748 Garching, Germany
2 shared publications
Latest Publications
- Open Access
- 26 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (2) , 392-403
New para -hydrogen cold neutron source at the Budapest Research Reactor: Monte Carlo simulations
The planned upgrade of the neutron guide system at the Budapest Research Reactor (BRR) provides an opportunity to enhance the performance of its cold neutron source. In this work, two replacement concepts for the existing liquid hydrogen disk moderator are investigated: (i) a box-shaped para -hydrogen (pH 2 ) moderator and (ii) assemblies of low-dimensional (flat) pH 2 moderators. Both designs are optimized using the curve of full and optimal sample illumination method and through Monte Carlo simulations tailored to the BRR geometry and the thermal neutron distribution. The box pH 2 moderator is found to increase the cold neutron brightness by up to 2.2 times in the 3–7 Å wavelength range. Flat moderator assemblies, as either staircases or chessboards, provide an additional gain of about 20% at 2 Å, although their advantage diminishes at longer wavelengths due to the non-uniform thermal illumination of the reactor channel and the wavelength dependence of the optimal moderator length. These results demonstrate that pH 2 moderators, particularly in low-dimensional geometries, can substantially enhance the performance of the upgraded BRR cold neutron source, with the achievable gains largely limited by the thermal neutron distribution within the existing moderator channel.
- 26 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (2) , 392-403
Open AccessNew para -hydrogen cold neutron source at the Budapest Research Reactor: Monte Carlo simulations
The planned upgrade of the neutron guide system at the Budapest Research Reactor (BRR) provides an opportunity to enhance the performance of its cold neutron source. In this work, two replacement concepts for the existing liquid hydrogen disk moderator are investigated: (i) a box-shaped para -hydrogen (pH 2 ) moderator and (ii) assemblies of low-dimensional (flat) pH 2 moderators. Both designs are optimized using the curve of full and optimal sample illumination method and through Monte Carlo simulations tailored to the BRR geometry and the thermal neutron distribution. The box pH 2 moderator is found to increase the cold neutron brightness by up to 2.2 times in the 3–7 Å wavelength range. Flat moderator assemblies, as either staircases or chessboards, provide an additional gain of about 20% at 2 Å, although their advantage diminishes at longer wavelengths due to the non-uniform thermal illumination of the reactor channel and the wavelength dependence of the optimal moderator length. These results demonstrate that pH 2 moderators, particularly in low-dimensional geometries, can substantially enhance the performance of the upgraded BRR cold neutron source, with the achievable gains largely limited by the thermal neutron distribution within the existing moderator channel.
- Open Access
- 17 January 2025
- Published by MDPI AG in Journal of Nuclear Engineering
- Vol. 6 (1) , 3
A Concept of a Para-Hydrogen-Based Cold Neutron Source for Simultaneous High Flux and High Brightness
A novel concept of cold neutron source employing chessboard or staircase assemblies of high-aspect-ratio rectangular para-hydrogen moderators with well-developed and practically fully illuminated surfaces of the individual moderators is proposed. An analytic approach for calculating the brightness of para-hydrogen moderators is introduced. Because the brightness gain originates from a near-surface effect resulting from the prevailing single-collision process during thermal-to-cold neutron conversion, high-aspect-ratio rectangular cold moderators offer a significant increase, up to a factor of 10, in cold neutron brightness compared to a voluminous moderator. The obtained results are in excellent agreement with MCNP calculations. The chessboard or staircase assemblies of such moderators facilitate the generation of wide neutron beams with simultaneously higher brightness and intensity compared to a para-hydrogen-based cold neutron source made of a single moderator (either flat or voluminous) of the same cross-section. Analytic model calculations indicate that gains of up to approximately 2.5 in both brightness and intensity can be achieved compared to a source made of a single moderator of the same width. However, these gains are affected by details of the moderator–reflector assembly and should be estimated through dedicated Monte Carlo simulations, which can only be conducted for a particular neutron source and are beyond the scope of this general study. The gain reduction in our study, from a higher value to 2.5, is mostly caused by these two factors: the limited volume of the high-density thermal neutron region surrounding the reactor core or spallation target, which restricts the total length of the moderator assembly, and the finite width of moderator walls. The relatively large length of moderator assemblies results in a significant increase in pulse duration at short pulse neutron sources, making their straightforward use very problematic, though some applications are not excluded. The concept of “low-dimensionality” in moderators is explored, demonstrating that achieving a substantial increase in brightness necessitates moderators to be low-dimensional both geometrically, implying a high aspect ratio, and physically, requiring the moderator’s smallest dimension to be smaller than the characteristic scale of moderator medium (about the mean free path for thermal neutrons). This explains why additional compression of the moderator along the longest direction, effectively giving it a tube-like shape, does not result in a significant brightness increase comparable to the flattening of the moderator.
- 17 January 2025
- Published by MDPI AG in Journal of Nuclear Engineering
- Vol. 6 (1) , 3
Open AccessA Concept of a Para-Hydrogen-Based Cold Neutron Source for Simultaneous High Flux and High Brightness
A novel concept of cold neutron source employing chessboard or staircase assemblies of high-aspect-ratio rectangular para-hydrogen moderators with well-developed and practically fully illuminated surfaces of the individual moderators is proposed. An analytic approach for calculating the brightness of para-hydrogen moderators is introduced. Because the brightness gain originates from a near-surface effect resulting from the prevailing single-collision process during thermal-to-cold neutron conversion, high-aspect-ratio rectangular cold moderators offer a significant increase, up to a factor of 10, in cold neutron brightness compared to a voluminous moderator. The obtained results are in excellent agreement with MCNP calculations. The chessboard or staircase assemblies of such moderators facilitate the generation of wide neutron beams with simultaneously higher brightness and intensity compared to a para-hydrogen-based cold neutron source made of a single moderator (either flat or voluminous) of the same cross-section. Analytic model calculations indicate that gains of up to approximately 2.5 in both brightness and intensity can be achieved compared to a source made of a single moderator of the same width. However, these gains are affected by details of the moderator–reflector assembly and should be estimated through dedicated Monte Carlo simulations, which can only be conducted for a particular neutron source and are beyond the scope of this general study. The gain reduction in our study, from a higher value to 2.5, is mostly caused by these two factors: the limited volume of the high-density thermal neutron region surrounding the reactor core or spallation target, which restricts the total length of the moderator assembly, and the finite width of moderator walls. The relatively large length of moderator assemblies results in a significant increase in pulse duration at short pulse neutron sources, making their straightforward use very problematic, though some applications are not excluded. The concept of “low-dimensionality” in moderators is explored, demonstrating that achieving a substantial increase in brightness necessitates moderators to be low-dimensional both geometrically, implying a high aspect ratio, and physically, requiring the moderator’s smallest dimension to be smaller than the characteristic scale of moderator medium (about the mean free path for thermal neutrons). This explains why additional compression of the moderator along the longest direction, effectively giving it a tube-like shape, does not result in a significant brightness increase comparable to the flattening of the moderator.
- Open Access
- 4 January 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 109 (1) , L011001
First measurement of neutron birefringence in polarized and nucleiWe present measurements of polarized neutron birefringence in transmission through nuclear-polarized and gas and determine the neutron incoherent scattering lengths and . These results determine the essential parameter needed for interpretation of spin-dependent neutron-scattering studies on polarized xenon ensembles with possible future applications ranging from tests of time-reversal violation to mode-entangled neutron scattering experiments on nuclear-polarized systems.- 4 January 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 109 (1) , L011001
Open AccessFirst measurement of neutron birefringence in polarized and nucleiWe present measurements of polarized neutron birefringence in transmission through nuclear-polarized and gas and determine the neutron incoherent scattering lengths and . These results determine the essential parameter needed for interpretation of spin-dependent neutron-scattering studies on polarized xenon ensembles with possible future applications ranging from tests of time-reversal violation to mode-entangled neutron scattering experiments on nuclear-polarized systems. - Open AccessA Complete Approach to Determine the $^3$He neutron incoherent scattering length $b_i$We report the first results from a new approach for measuring the $^3$He neutron incoherent scattering length $b_{i}$. $b_{i}$ is directly proportional to the difference $Δb=b_{+}-b_{-}$ in the two low-energy s-wave neutron-nucleus scattering amplitudes $b_{+}$ and $b_{-}$, corresponding to the singlet $J=0$ and triplet $J=1$ states of the neutron-$^3$He interaction, respectively. An accurate measurement of $b_{i}$ can help distinguish among different models of three-nucleon interactions by comparison to {\it ab initio} nuclear theory calculations. The neutron birefringence caused by $Δb$ results in neutron spin rotation around the nuclear polarization. We measured $Δb$ using polarized neutron spin rotation and the transmission of neutrons through a $^3$He gas target polarized in situ by spin-exchange optical pumping. This brief test measurement, conducted at the FZ-Jülich neutron spin echo spectrometer at the Heinz Maier Leibnitz Zentrum (MLZ), yielded $Δb = [-5.27 \pm 0.05$ (stat.) $- 0.05$ (syst.)] fm. We argue that this method can be improved in precision to resolve the discrepancies between two prior measurements of $b_i$ which are dependent on the polarized absorption cross section $σ_p$. Further with absolute $^{3}$He polarization via NMR (in a properly-shaped cell) concurrent with accurate neutron transmission measurements, $σ_p$ can be measured to obtain independent values of $b_{+}$ and $b_{-}$.Open AccessA Complete Approach to Determine the $^3$He neutron incoherent scattering length $b_i$We report the first results from a new approach for measuring the $^3$He neutron incoherent scattering length $b_{i}$. $b_{i}$ is directly proportional to the difference $Δb=b_{+}-b_{-}$ in the two low-energy s-wave neutron-nucleus scattering amplitudes $b_{+}$ and $b_{-}$, corresponding to the singlet $J=0$ and triplet $J=1$ states of the neutron-$^3$He interaction, respectively. An accurate measurement of $b_{i}$ can help distinguish among different models of three-nucleon interactions by comparison to {\it ab initio} nuclear theory calculations. The neutron birefringence caused by $Δb$ results in neutron spin rotation around the nuclear polarization. We measured $Δb$ using polarized neutron spin rotation and the transmission of neutrons through a $^3$He gas target polarized in situ by spin-exchange optical pumping. This brief test measurement, conducted at the FZ-Jülich neutron spin echo spectrometer at the Heinz Maier Leibnitz Zentrum (MLZ), yielded $Δb = [-5.27 \pm 0.05$ (stat.) $- 0.05$ (syst.)] fm. We argue that this method can be improved in precision to resolve the discrepancies between two prior measurements of $b_i$ which are dependent on the polarized absorption cross section $σ_p$. Further with absolute $^{3}$He polarization via NMR (in a properly-shaped cell) concurrent with accurate neutron transmission measurements, $σ_p$ can be measured to obtain independent values of $b_{+}$ and $b_{-}$.
- 9 October 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 986, 164749
Experimental test of the rotating magnetic field neutron spin-echo technique: Spin-echo and MIEZE for large energy transfers
- 9 October 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 986, 164749
Experimental test of the rotating magnetic field neutron spin-echo technique: Spin-echo and MIEZE for large energy transfers
- 1 January 2018
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 161, 18-26
Studies on the adsorption and desorption of mitoxantrone to lauric acid/albumin coated iron oxide nanoparticles
- 1 January 2018
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 161, 18-26
Studies on the adsorption and desorption of mitoxantrone to lauric acid/albumin coated iron oxide nanoparticles
- Open Access
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1969 (1) , 050005
Towards wide-angle neutron polarization analysis with a 3He spin filter for TOPAS and NEAT: Testing magic PASTIS on V20 at HZB
An XYZ polarization analysis solution has been developed for the new thermal time-of-flight spectrometer TOPAS [1], to be operated in the coming east neutron guide hall at the MLZ. This prototype is currently being prepared to use on NEAT at HZB [2]. Polarization Analysis Studies on a Thermal Inelastic Spectrometer, commonly called PASTIS [3], is based on polarized 3He neutron spin filters and an XYZ field configuration for the sample environment and a polarization-preserving neutron guide field. The complete system was designed to provide adiabatic transport of the neutron polarization to the sample position on TOPAS while maintaining the homogeneity of the XYZ field. This complete system has now been tested on the polarized time-of-flight ESS test beam line V20 at HZB [4]. We present results of this test and the next steps forward.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1969 (1) , 050005
Open AccessTowards wide-angle neutron polarization analysis with a 3He spin filter for TOPAS and NEAT: Testing magic PASTIS on V20 at HZB
An XYZ polarization analysis solution has been developed for the new thermal time-of-flight spectrometer TOPAS [1], to be operated in the coming east neutron guide hall at the MLZ. This prototype is currently being prepared to use on NEAT at HZB [2]. Polarization Analysis Studies on a Thermal Inelastic Spectrometer, commonly called PASTIS [3], is based on polarized 3He neutron spin filters and an XYZ field configuration for the sample environment and a polarization-preserving neutron guide field. The complete system was designed to provide adiabatic transport of the neutron polarization to the sample position on TOPAS while maintaining the homogeneity of the XYZ field. This complete system has now been tested on the polarized time-of-flight ESS test beam line V20 at HZB [4]. We present results of this test and the next steps forward.
- Open Access
- 24 July 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 528, 012015
3He Neutron Spin Filter cell development program at JCNS
- 24 July 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 528, 012015
Open Access3He Neutron Spin Filter cell development program at JCNS
- 1 January 2014
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 17 (1) , 19-26
Extension of the VITESS polarized neutron suite towards the use of imported magnetic field distributions
Latest developments of the polarized neutron suite in the VITESS simulation package allowed for simulations of time-dependent spin handling devices (e.g. radio-frequency (RF) flippers, adiabatic gradient RF-flippers) and the instrumentation built upon them (NRSE, SESANS, MIEZE, etc.). However, till now the magnetic field distribution in such devices have been considered as “ideal” (sinusoidal, triangular or rectangular), when the main practical interest is in the use of arbitrary magnetic field distributions (either obtained by the field mapping or by FEM calculations) that may significantly influence the performance of real polarized neutron instruments and is the key issue in the practical use of the simulation packages. Here we describe modified VITESS modules opening the possibility to load the magnetic field 3-dimensional space map from an external source (file). Such a map can be either obtained by direct measurements or calculated by dedicated FEM programs (such as ANSYS, MagNet, Maxwell or similar). The successful use of these new modules is demonstrated by a very good agreement of neutron polarimetric experiments with performance of the spin turner with rotating magnetic field and an adiabatic gradient RF-flipper simulated by VITESS using calculated 3-dimensional field maps (using MagNet) and magnetic field mapping, respectively.
- 1 January 2014
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 17 (1) , 19-26
Extension of the VITESS polarized neutron suite towards the use of imported magnetic field distributions
Latest developments of the polarized neutron suite in the VITESS simulation package allowed for simulations of time-dependent spin handling devices (e.g. radio-frequency (RF) flippers, adiabatic gradient RF-flippers) and the instrumentation built upon them (NRSE, SESANS, MIEZE, etc.). However, till now the magnetic field distribution in such devices have been considered as “ideal” (sinusoidal, triangular or rectangular), when the main practical interest is in the use of arbitrary magnetic field distributions (either obtained by the field mapping or by FEM calculations) that may significantly influence the performance of real polarized neutron instruments and is the key issue in the practical use of the simulation packages. Here we describe modified VITESS modules opening the possibility to load the magnetic field 3-dimensional space map from an external source (file). Such a map can be either obtained by direct measurements or calculated by dedicated FEM programs (such as ANSYS, MagNet, Maxwell or similar). The successful use of these new modules is demonstrated by a very good agreement of neutron polarimetric experiments with performance of the spin turner with rotating magnetic field and an adiabatic gradient RF-flipper simulated by VITESS using calculated 3-dimensional field maps (using MagNet) and magnetic field mapping, respectively.
- Open Access
- 1 January 2013
- Published by Elsevier in Physics Procedia
- Vol. 42, 154-162
Polarization Analysis with 3He Spin Filters for Separating Coherent from Incoherent Scattering in Soft Matter Studies
- 1 January 2013
- Published by Elsevier in Physics Procedia
- Vol. 42, 154-162
Open AccessPolarization Analysis with 3He Spin Filters for Separating Coherent from Incoherent Scattering in Soft Matter Studies