Tadanori Fukami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tadanori Fukami has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Takamasa Shimada
Tokyo Denki University
5 shared publicationsBunnoshin Ishikawa
Hotokukai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan
4 shared publications- Chifumi Iseki
Department of Behavioral Neurology and Cognitive Neuroscience, Tohoku University Graduate School of Medicine, Sendai, Japan
4 shared publications - Masatsune Ishikawa
Normal Pressure Hydrocephalus Center, Rakuwakai Otowa Hospital, Kyoto 607-8062, Japan
4 shared publications - Shigeki Yamada
Department of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, Aichi, Japan
4 shared publications - Shigeo Ueda
Shin-ai Kai Spine Center, Katano Hospital, Osaka, Japan
4 shared publications
Latest Publications
- 12 August 2026
- Published by Springer Nature
- p. 14-20
Classification of EEGs During Actual Finger Movements Using Phase Difference
- 12 August 2026
- Published by Springer Nature
- p. 14-20
Classification of EEGs During Actual Finger Movements Using Phase Difference
- Open Access
Fluctuations in Upper and Lower Body Movement during Walking in Normal Pressure Hydrocephalus and Parkinson’s Disease Assessed by Motion Capture with a Smartphone Application, TDPT-GT
We aimed to capture the fluctuations in the dynamics of body positions and find the characteristics of them in patients with idiopathic normal pressure hydrocephalus (iNPH) and Parkinson’s disease (PD). With the motion-capture application (TDPT-GT) generating 30 Hz coordinates at 27 points on the body, walking in a circle 1 m in diameter was recorded for 23 of iNPH, 23 of PD, and 92 controls. For 128 frames of calculated distances from the navel to the other points, after the Fourier transforms, the slopes (the representatives of fractality) were obtained from the graph plotting the power spectral density against the frequency in log–log coordinates. Differences in the average slopes were tested by one-way ANOVA and multiple comparisons between every two groups. A decrease in the absolute slope value indicates a departure from the 1/f noise characteristic observed in healthy variations. Significant differences in the patient groups and controls were found in all body positions, where patients always showed smaller absolute values. Our system could measure the whole body’s movement and temporal variations during walking. The impaired fluctuations of body movement in the upper and lower body may contribute to gait and balance disorders in patients.
Open AccessFluctuations in Upper and Lower Body Movement during Walking in Normal Pressure Hydrocephalus and Parkinson’s Disease Assessed by Motion Capture with a Smartphone Application, TDPT-GT
We aimed to capture the fluctuations in the dynamics of body positions and find the characteristics of them in patients with idiopathic normal pressure hydrocephalus (iNPH) and Parkinson’s disease (PD). With the motion-capture application (TDPT-GT) generating 30 Hz coordinates at 27 points on the body, walking in a circle 1 m in diameter was recorded for 23 of iNPH, 23 of PD, and 92 controls. For 128 frames of calculated distances from the navel to the other points, after the Fourier transforms, the slopes (the representatives of fractality) were obtained from the graph plotting the power spectral density against the frequency in log–log coordinates. Differences in the average slopes were tested by one-way ANOVA and multiple comparisons between every two groups. A decrease in the absolute slope value indicates a departure from the 1/f noise characteristic observed in healthy variations. Significant differences in the patient groups and controls were found in all body positions, where patients always showed smaller absolute values. Our system could measure the whole body’s movement and temporal variations during walking. The impaired fluctuations of body movement in the upper and lower body may contribute to gait and balance disorders in patients.
- Open Access
Artificial Intelligence Distinguishes Pathological Gait: The Analysis of Markerless Motion Capture Gait Data Acquired by an iOS Application (TDPT-GT)
Distinguishing pathological gait is challenging in neurology because of the difficulty of capturing total body movement and its analysis. We aimed to obtain a convenient recording with an iPhone and establish an algorithm based on deep learning. From May 2021 to November 2022 at Yamagata University Hospital, Shiga University, and Takahata Town, patients with idiopathic normal pressure hydrocephalus (n = 48), Parkinson’s disease (n = 21), and other neuromuscular diseases (n = 45) comprised the pathological gait group (n = 114), and the control group consisted of 160 healthy volunteers. iPhone application TDPT-GT captured the subjects walking in a circular path of about 1 meter in diameter, a markerless motion capture system, with an iPhone camera, which generated the three-axis 30 frames per second (fps) relative coordinates of 27 body points. A light gradient boosting machine (Light GBM) with stratified k-fold cross-validation (k = 5) was applied for gait collection for about 1 min per person. The median ability model tested 200 frames of each person’s data for its distinction capability, which resulted in the area under a curve of 0.719. The pathological gait captured by the iPhone could be distinguished by artificial intelligence.
Open AccessArtificial Intelligence Distinguishes Pathological Gait: The Analysis of Markerless Motion Capture Gait Data Acquired by an iOS Application (TDPT-GT)
Distinguishing pathological gait is challenging in neurology because of the difficulty of capturing total body movement and its analysis. We aimed to obtain a convenient recording with an iPhone and establish an algorithm based on deep learning. From May 2021 to November 2022 at Yamagata University Hospital, Shiga University, and Takahata Town, patients with idiopathic normal pressure hydrocephalus (n = 48), Parkinson’s disease (n = 21), and other neuromuscular diseases (n = 45) comprised the pathological gait group (n = 114), and the control group consisted of 160 healthy volunteers. iPhone application TDPT-GT captured the subjects walking in a circular path of about 1 meter in diameter, a markerless motion capture system, with an iPhone camera, which generated the three-axis 30 frames per second (fps) relative coordinates of 27 body points. A light gradient boosting machine (Light GBM) with stratified k-fold cross-validation (k = 5) was applied for gait collection for about 1 min per person. The median ability model tested 200 frames of each person’s data for its distinction capability, which resulted in the area under a curve of 0.719. The pathological gait captured by the iPhone could be distinguished by artificial intelligence.
- Open Access
Quantitative Gait Feature Assessment on Two-Dimensional Body Axis Projection Planes Converted from Three-Dimensional Coordinates Estimated with a Deep Learning Smartphone App
To assess pathological gaits quantitatively, three-dimensional coordinates estimated with a deep learning model were converted into body axis plane projections. First, 15 healthy volunteers performed four gait patterns; that is, normal, shuffling, short-stepped, and wide-based gaits, with the Three-Dimensional Pose Tracker for Gait Test (TDPT-GT) application. Second, gaits of 47 patients with idiopathic normal pressure hydrocephalus (iNPH) and 92 healthy elderly individuals in the Takahata cohort were assessed with the TDPT-GT. Two-dimensional relative coordinates were calculated from the three-dimensional coordinates by projecting the sagittal, coronal, and axial planes. Indices of the two-dimensional relative coordinates associated with a pathological gait were comprehensively explored. The candidate indices for the shuffling gait were the angle range of the hip joint < 30° and relative vertical amplitude of the heel < 0.1 on the sagittal projection plane. For the short-stepped gait, the angle range of the knee joint < 45° on the sagittal projection plane was a candidate index. The candidate index for the wide-based gait was the leg outward shift > 0.1 on the axial projection plane. In conclusion, the two-dimensional coordinates on the body axis projection planes calculated from the 3D relative coordinates estimated by the TDPT-GT application enabled the quantification of pathological gait features.
Open AccessQuantitative Gait Feature Assessment on Two-Dimensional Body Axis Projection Planes Converted from Three-Dimensional Coordinates Estimated with a Deep Learning Smartphone App
To assess pathological gaits quantitatively, three-dimensional coordinates estimated with a deep learning model were converted into body axis plane projections. First, 15 healthy volunteers performed four gait patterns; that is, normal, shuffling, short-stepped, and wide-based gaits, with the Three-Dimensional Pose Tracker for Gait Test (TDPT-GT) application. Second, gaits of 47 patients with idiopathic normal pressure hydrocephalus (iNPH) and 92 healthy elderly individuals in the Takahata cohort were assessed with the TDPT-GT. Two-dimensional relative coordinates were calculated from the three-dimensional coordinates by projecting the sagittal, coronal, and axial planes. Indices of the two-dimensional relative coordinates associated with a pathological gait were comprehensively explored. The candidate indices for the shuffling gait were the angle range of the hip joint < 30° and relative vertical amplitude of the heel < 0.1 on the sagittal projection plane. For the short-stepped gait, the angle range of the knee joint < 45° on the sagittal projection plane was a candidate index. The candidate index for the wide-based gait was the leg outward shift > 0.1 on the axial projection plane. In conclusion, the two-dimensional coordinates on the body axis projection planes calculated from the 3D relative coordinates estimated by the TDPT-GT application enabled the quantification of pathological gait features.
- Open Access
Development of Smartphone Application for Markerless Three-Dimensional Motion Capture Based on Deep Learning Model
To quantitatively assess pathological gait, we developed a novel smartphone application for full-body human motion tracking in real time from markerless video-based images using a smartphone monocular camera and deep learning. As training data for deep learning, the original three-dimensional (3D) dataset comprising more than 1 million captured images from the 3D motion of 90 humanoid characters and the two-dimensional dataset of COCO 2017 were prepared. The 3D heatmap offset data consisting of 28 × 28 × 28 blocks with three red–green–blue colors at the 24 key points of the entire body motion were learned using the convolutional neural network, modified ResNet34. At each key point, the hottest spot deviating from the center of the cell was learned using the tanh function. Our new iOS application could detect the relative tri-axial coordinates of the 24 whole-body key points centered on the navel in real time without any markers for motion capture. By using the relative coordinates, the 3D angles of the neck, lumbar, bilateral hip, knee, and ankle joints were estimated. Any human motion could be quantitatively and easily assessed using a new smartphone application named Three-Dimensional Pose Tracker for Gait Test (TDPT-GT) without any body markers or multipoint cameras.
Open AccessDevelopment of Smartphone Application for Markerless Three-Dimensional Motion Capture Based on Deep Learning Model
To quantitatively assess pathological gait, we developed a novel smartphone application for full-body human motion tracking in real time from markerless video-based images using a smartphone monocular camera and deep learning. As training data for deep learning, the original three-dimensional (3D) dataset comprising more than 1 million captured images from the 3D motion of 90 humanoid characters and the two-dimensional dataset of COCO 2017 were prepared. The 3D heatmap offset data consisting of 28 × 28 × 28 blocks with three red–green–blue colors at the 24 key points of the entire body motion were learned using the convolutional neural network, modified ResNet34. At each key point, the hottest spot deviating from the center of the cell was learned using the tanh function. Our new iOS application could detect the relative tri-axial coordinates of the 24 whole-body key points centered on the navel in real time without any markers for motion capture. By using the relative coordinates, the 3D angles of the neck, lumbar, bilateral hip, knee, and ankle joints were estimated. Any human motion could be quantitatively and easily assessed using a new smartphone application named Three-Dimensional Pose Tracker for Gait Test (TDPT-GT) without any body markers or multipoint cameras.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 6090-6093
Reduction of the ERP Measurement Time by a Weighted Averaging Using Deep Learning
In clinical examination, event-related potentials (ERPs) are estimated by averaging across multiple responses, which suppresses background EEG. However, acquiring the number of responses needed for this process is time consuming. We therefore propose a method for shortening the measurement time using weighted-average processing based on the output of deep learning. Using P300 as a representative component, here we focused on the shape of the ERP and evaluated whether our method emphasizes the P300 peak amplitude more than conventional averaging, while still maintaining the waveform shape and the P300 peak latency. Thus, using either CNN or EEGNet, the correlation coefficient reflecting the waveform shape, the peak P300 amplitude, and the peak latency were evaluated and compared with the same factors obtained from conventional waveform averaging. Additionally, the degree of background EEG suppression provided by our method was evaluated using the root mean square of the pre-stimulation waveform, and the number of fewer responses required for averaging (i.e., the reduction in measurement time) was calculated.The results showed that compared with P300 values obtained through conventional averaging, our method allowed for the same shape and response latency, but with a higher amplitude, while requiring a smaller number of responses. Our method showed that by using EEGNet, measurement time could be reduced by 13.7%. This corresponds to approximately a 40-second reduction for every 5 minutes of measurement time.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 6090-6093
Reduction of the ERP Measurement Time by a Weighted Averaging Using Deep Learning
In clinical examination, event-related potentials (ERPs) are estimated by averaging across multiple responses, which suppresses background EEG. However, acquiring the number of responses needed for this process is time consuming. We therefore propose a method for shortening the measurement time using weighted-average processing based on the output of deep learning. Using P300 as a representative component, here we focused on the shape of the ERP and evaluated whether our method emphasizes the P300 peak amplitude more than conventional averaging, while still maintaining the waveform shape and the P300 peak latency. Thus, using either CNN or EEGNet, the correlation coefficient reflecting the waveform shape, the peak P300 amplitude, and the peak latency were evaluated and compared with the same factors obtained from conventional waveform averaging. Additionally, the degree of background EEG suppression provided by our method was evaluated using the root mean square of the pre-stimulation waveform, and the number of fewer responses required for averaging (i.e., the reduction in measurement time) was calculated.The results showed that compared with P300 values obtained through conventional averaging, our method allowed for the same shape and response latency, but with a higher amplitude, while requiring a smaller number of responses. Our method showed that by using EEGNet, measurement time could be reduced by 13.7%. This corresponds to approximately a 40-second reduction for every 5 minutes of measurement time.
- 27 April 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (3) , 036030
Fast EEG spike detection via eigenvalue analysis and clustering of spatial amplitude distribution
Objective . In the current study, we tested a proposed method for fast spike detection in electroencephalography (EEG). Approach . We performed eigenvalue analysis in two-dimensional space spanned by gradients calculated from two neighboring samples to detect high-amplitude negative peaks. We extracted the spike candidates by imposing restrictions on parameters regarding spike shape and eigenvalues reflecting detection characteristics of individual medical doctors. We subsequently performed clustering, classifying detected peaks by considering the amplitude distribution at 19 scalp electrodes. Clusters with a small number of candidates were excluded. We then defined a score for eliminating spike candidates for which the pattern of detected electrodes differed from the overall pattern in a cluster. Spikes were detected by setting the score threshold. Main results . Based on visual inspection by a psychiatrist experienced in EEG, we evaluated the proposed method using two statistical measures of precision and recall with respect to detection performance. We found that precision and recall exhibited a trade-off relationship. The average recall value was 0.708 in eight subjects with the score threshold that maximized the F-measure, with 58.6 ± 36.2 spikes per subject. Under this condition, the average precision was 0.390, corresponding to a false positive rate 2.09 times higher than the true positive rate. Analysis of the required processing time revealed that, using a general-purpose computer, our method could be used to perform spike detection in 12.1% of the recording time. The process of narrowing down spike candidates based on shape occupied most of the processing time. Significance . Although the average recall value was comparable with that of other studies, the proposed method significantly shortened the processing time.
- 27 April 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (3) , 036030
Fast EEG spike detection via eigenvalue analysis and clustering of spatial amplitude distribution
Objective . In the current study, we tested a proposed method for fast spike detection in electroencephalography (EEG). Approach . We performed eigenvalue analysis in two-dimensional space spanned by gradients calculated from two neighboring samples to detect high-amplitude negative peaks. We extracted the spike candidates by imposing restrictions on parameters regarding spike shape and eigenvalues reflecting detection characteristics of individual medical doctors. We subsequently performed clustering, classifying detected peaks by considering the amplitude distribution at 19 scalp electrodes. Clusters with a small number of candidates were excluded. We then defined a score for eliminating spike candidates for which the pattern of detected electrodes differed from the overall pattern in a cluster. Spikes were detected by setting the score threshold. Main results . Based on visual inspection by a psychiatrist experienced in EEG, we evaluated the proposed method using two statistical measures of precision and recall with respect to detection performance. We found that precision and recall exhibited a trade-off relationship. The average recall value was 0.708 in eight subjects with the score threshold that maximized the F-measure, with 58.6 ± 36.2 spikes per subject. Under this condition, the average precision was 0.390, corresponding to a false positive rate 2.09 times higher than the true positive rate. Analysis of the required processing time revealed that, using a general-purpose computer, our method could be used to perform spike detection in 12.1% of the recording time. The process of narrowing down spike candidates based on shape occupied most of the processing time. Significance . Although the average recall value was comparable with that of other studies, the proposed method significantly shortened the processing time.
- 1 March 2016
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 125, 26-36
Robust estimation of event-related potentials via particle filter
- 1 March 2016
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 125, 26-36
Robust estimation of event-related potentials via particle filter
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 134 (10) , 1498-1505
Measurement of Stress Level during Calculation Task with EEG
At present, people live by suffering from strong stresses in the complex society system. It is said that stresses relates to lifestyle related disease and mental disease. These days, stress healing methods for promoting effect of stress like color therapies which affect human senses, are becoming available to be used at a hospital and a nursing home. However, there was little study about real time measurement of stress level which is useful for constructing effective stress healing system. In this study, we tried to verify the possibility of real time stress measurement by using information of EEG. In our experiment, EEG was recorded while subjects were suffering from stress of calculation task and relaxing. The stress level was measured by questionnaire which is non real time subjective stress measurement method and also by salivary amylase activity which is non real time objective stress measurement method simultaneously. As a result, the correlation between normalized salivary amylase activity and normalized power spectrum of beta band of EEG showed middle intensity and the possibility of real time stress measurement with EEG was clarified.
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 134 (10) , 1498-1505
Measurement of Stress Level during Calculation Task with EEG
At present, people live by suffering from strong stresses in the complex society system. It is said that stresses relates to lifestyle related disease and mental disease. These days, stress healing methods for promoting effect of stress like color therapies which affect human senses, are becoming available to be used at a hospital and a nursing home. However, there was little study about real time measurement of stress level which is useful for constructing effective stress healing system. In this study, we tried to verify the possibility of real time stress measurement by using information of EEG. In our experiment, EEG was recorded while subjects were suffering from stress of calculation task and relaxing. The stress level was measured by questionnaire which is non real time subjective stress measurement method and also by salivary amylase activity which is non real time objective stress measurement method simultaneously. As a result, the correlation between normalized salivary amylase activity and normalized power spectrum of beta band of EEG showed middle intensity and the possibility of real time stress measurement with EEG was clarified.
- 1 January 2013
- Published by Springer Nature
- p. 1002-1005
Brain Activation in Limbic System during Presentation of Happy and Neutral Faces
- 1 January 2013
- Published by Springer Nature
- p. 1002-1005
Brain Activation in Limbic System during Presentation of Happy and Neutral Faces