Cyrille Thomas
Research Subjects
Cyrille Thomas has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
C. Bruni
LURE, Université Paris-Sud
1 shared publicationD. Garzella
LURE, Université Paris-Sud
1 shared publicationG. Orlandi
LURE, Université Paris-Sud
1 shared publicationG. Rehm
Diamond Light Source, RAL, Chilton, UK
1 shared publicationG. de Ninno
Sincrotrone Trieste
1 shared publicationGuenther Rehm
1 shared publication
Latest Publications
- Open Access
- 24 February 2010
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 13 (2)
X-ray pinhole camera resolution and emittance measurement
Third generation synchrotron light sources are characterized by a low emittance and a low emittance coupling. Some light sources are already operating with extremely low coupling close to 0.1%. Measurement of the transverse beam size is generally used to measure the emittance and the coupling. To this end, several systems are currently used and an x-ray pinhole camera is one of them. In this paper we derive the point spread function of the x-ray pinhole camera both analytically and numerically using the Fresnel diffraction integral and taking into account the broadband spectrum of the bending magnet source, and we show that an optimized design allows the measurement of extremely small vertical beam sizes below 5\,\,$\mu${}m. The point spread function of several scintillator screens is also measured, and it shows that the contribution of the diffraction and the screen point spread functions have to be taken into account for an accurate measurement of a low coupling. Finally, we show measurements of the vertical beam sizes as small as 6\,\,$\mu${}m for our nonoptimized setup.
- 24 February 2010
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 13 (2)
Open AccessX-ray pinhole camera resolution and emittance measurement
Third generation synchrotron light sources are characterized by a low emittance and a low emittance coupling. Some light sources are already operating with extremely low coupling close to 0.1%. Measurement of the transverse beam size is generally used to measure the emittance and the coupling. To this end, several systems are currently used and an x-ray pinhole camera is one of them. In this paper we derive the point spread function of the x-ray pinhole camera both analytically and numerically using the Fresnel diffraction integral and taking into account the broadband spectrum of the bending magnet source, and we show that an optimized design allows the measurement of extremely small vertical beam sizes below 5\,\,$\mu${}m. The point spread function of several scintillator screens is also measured, and it shows that the contribution of the diffraction and the screen point spread functions have to be taken into account for an accurate measurement of a low coupling. Finally, we show measurements of the vertical beam sizes as small as 6\,\,$\mu${}m for our nonoptimized setup.
- 22 August 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 566 (2) , 762-766
Bunch purity measurement for Diamond
- 22 August 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 566 (2) , 762-766
Bunch purity measurement for Diamond
- 4 January 2005
- Published by Springer Nature in The European Physical Journal D
- Vol. 32 (1) , 83-93
Storage ring free electron laser dynamics in presence of an auxiliary harmonic radio frequency cavity
- 4 January 2005
- Published by Springer Nature in The European Physical Journal D
- Vol. 32 (1) , 83-93
Storage ring free electron laser dynamics in presence of an auxiliary harmonic radio frequency cavity