Helen T. Winer-Muram
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Helen T. Winer-Muram has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
S. Gregory Jennings
6 shared publicationsCristopher A. Meyer
4 shared publicationsRobert D. Tarver
3 shared publicationsAlex M. Aisen
2 shared publicationsMark Tann
2 shared publicationsAlex M Aisen
1 shared publication
Latest Publications
- 1 April 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (1) , 34-49
The Solitary Pulmonary Nodule
The imaging evaluation of a solitary pulmonary nodule is complex. Management decisions are based on clinical history, size and appearance of the nodule, and feasibility of obtaining a tissue diagnosis. The most reliable imaging features are those that are indicative of benignancy, such as a benign pattern of calcification and periodic follow-up with computed tomography for 2 years showing no growth. Fine-needle aspiration biopsy and core biopsy are important procedures that may obviate surgery if there is a specific benign diagnosis from the procedure. In using the various imaging and diagnostic modalities described in this review, one should strive to not only identify small malignant tumors--where resection results in high survival rates--but also spare patients with benign disease from undergoing unnecessary surgery.
- 1 April 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (1) , 34-49
The Solitary Pulmonary Nodule
The imaging evaluation of a solitary pulmonary nodule is complex. Management decisions are based on clinical history, size and appearance of the nodule, and feasibility of obtaining a tissue diagnosis. The most reliable imaging features are those that are indicative of benignancy, such as a benign pattern of calcification and periodic follow-up with computed tomography for 2 years showing no growth. Fine-needle aspiration biopsy and core biopsy are important procedures that may obviate surgery if there is a specific benign diagnosis from the procedure. In using the various imaging and diagnostic modalities described in this review, one should strive to not only identify small malignant tumors--where resection results in high survival rates--but also spare patients with benign disease from undergoing unnecessary surgery.
- 1 December 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (3) , 806-815
Suspected Acute Pulmonary Embolism: Evaluation with Multi–Detector Row CT versus Digital Subtraction Pulmonary Arteriography
To determine diagnostic accuracy of four-channel multi-detector row computed tomography (CT) in emergency room and inpatient populations suspected of having acute pulmonary embolism (PE) who prospectively underwent both CT and pulmonary arteriography (PA). Patients referred for PA to assess suspected PE were eligible. Institutional review board approval and written informed consent were obtained. All patients underwent CT and PA within a 48-hour period. For CT, 4 x 2.5-mm collimation was used. Three readers independently evaluated each study for PE presence. PE status, vessel level, and lobar location were determined by means of majority rule, and interobserver agreement (kappa) was calculated for PE status, as assessed with each modality. Sensitivity and specificity of CT were calculated by using PA as the reference standard. Two radiologists later reviewed false-positive CT studies. The study group comprised 93 patients (median age, 56 years; range, 19-88 years). Sensitivity, specificity, and accuracy of CT were 100%, 89%, and 91%, respectively. kappa values were 0.71 and 0.83 for CT and PA, respectively, and were not significantly different between modalities. At PA, 18 patients (19%) had PE at 50 vessel levels (five main and/or interlobar, 24 segmental, and 21 subsegmental), 17 (94%) of which had PE at multiple sites. At CT, 26 patients (28%) had PE at 71 vessel levels (24 main and/or interlobar, 33 segmental, and 14 subsegmental). Twenty patients (77%) had PE at multiple sites. Review of eight false-positive CT studies showed an appearance highly suggestive of acute PE in three patients, chronic PE in one, and no PE in three; one study was inconclusive. CT better demonstrated large-level vessel involvement (P < .01), while PA better demonstrated small-level vessel involvement (P < .01). Multi-detector row CT has an accuracy of 91% in the depiction of suspected acute PE when conventional PA is used as the reference standard.
- 1 December 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (3) , 806-815
Suspected Acute Pulmonary Embolism: Evaluation with Multi–Detector Row CT versus Digital Subtraction Pulmonary Arteriography
To determine diagnostic accuracy of four-channel multi-detector row computed tomography (CT) in emergency room and inpatient populations suspected of having acute pulmonary embolism (PE) who prospectively underwent both CT and pulmonary arteriography (PA). Patients referred for PA to assess suspected PE were eligible. Institutional review board approval and written informed consent were obtained. All patients underwent CT and PA within a 48-hour period. For CT, 4 x 2.5-mm collimation was used. Three readers independently evaluated each study for PE presence. PE status, vessel level, and lobar location were determined by means of majority rule, and interobserver agreement (kappa) was calculated for PE status, as assessed with each modality. Sensitivity and specificity of CT were calculated by using PA as the reference standard. Two radiologists later reviewed false-positive CT studies. The study group comprised 93 patients (median age, 56 years; range, 19-88 years). Sensitivity, specificity, and accuracy of CT were 100%, 89%, and 91%, respectively. kappa values were 0.71 and 0.83 for CT and PA, respectively, and were not significantly different between modalities. At PA, 18 patients (19%) had PE at 50 vessel levels (five main and/or interlobar, 24 segmental, and 21 subsegmental), 17 (94%) of which had PE at multiple sites. At CT, 26 patients (28%) had PE at 71 vessel levels (24 main and/or interlobar, 33 segmental, and 14 subsegmental). Twenty patients (77%) had PE at multiple sites. Review of eight false-positive CT studies showed an appearance highly suggestive of acute PE in three patients, chronic PE in one, and no PE in three; one study was inconclusive. CT better demonstrated large-level vessel involvement (P < .01), while PA better demonstrated small-level vessel involvement (P < .01). Multi-detector row CT has an accuracy of 91% in the depiction of suspected acute PE when conventional PA is used as the reference standard.
- 1 January 2004
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 28 (4) , 455-458
Computed Tomography Demonstration of Lipomatous Metaplasia of the Left Ventricle Following Myocardial Infarction
Replacement of myocardium by fat, particularly of the right ventricle, is often diagnosed as arrhythmogenic right ventricular dysplasia. At autopsy, however, 68% of scars associated with chronic ischemic heart disease have shown fatty metaplasia in the scar. Four patients with a past history of previous myocardial infarctions and computed tomography demonstration of fatty change in left ventricular regions of hypokinesis and infarction are presented. It is proposed that these findings represent ischemic fatty metaplasia, an alternative etiology of fatty tissue replacing myocardium.
- 1 January 2004
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 28 (4) , 455-458
Computed Tomography Demonstration of Lipomatous Metaplasia of the Left Ventricle Following Myocardial Infarction
Replacement of myocardium by fat, particularly of the right ventricle, is often diagnosed as arrhythmogenic right ventricular dysplasia. At autopsy, however, 68% of scars associated with chronic ischemic heart disease have shown fatty metaplasia in the scar. Four patients with a past history of previous myocardial infarctions and computed tomography demonstration of fatty change in left ventricular regions of hypokinesis and infarction are presented. It is proposed that these findings represent ischemic fatty metaplasia, an alternative etiology of fatty tissue replacing myocardium.
- 1 October 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 229 (1) , 184-194
Effect of Varying CT Section Width on Volumetric Measurement of Lung Tumors and Application of Compensatory Equations
To determine how volume measurements of simulated and clinical lung tumors at standard computed tomographic (CT) lung window and level settings vary with section width and to derive and apply compensatory equations. Spherical simulated tumors of varying diameters were imaged with varying CT section widths, the images were displayed on a workstation, the cross-sectional area of the tumor on each section was measured by using elliptical and perimeter methods, and the areas were integrated to compute tumor volume. The actual and measured tumor volumes for differing section widths and tumor diameters were compared, and compensatory equations were derived. The equations were applied to contemporaneous chest CT images obtained in patients with stage I lung cancer, and the difference between thick- and thin-section-derived volumes before and after application of the equations was determined. All simulated tumor volumes were overestimated 11%-278%; overestimation varied directly with section width and inversely with tumor diameter. With both measurement methods, mean thin-section volumes of clinical tumors in 55 patients were significantly smaller (P <.01) than mean thick-section volumes: Mean elliptical measurements were 15,025 mm3 (thin) and 18,037 mm3 (thick), with a 20.0% difference; mean perimeter measurements were 16,164 mm3 (thin) and 20,718 mm3 (thick), with a 22.2% difference. The thin-section-to-thick-section volume difference was larger for the smallest tumors. Thin-section volumes were smaller than thick-section volumes in 53 patients with the elliptical method and in 51 patients with the perimeter method. Applying the equations decreased the difference between thick- and thin-section volumes in 37 (67%) of the 55 patients with the elliptical method and in 41 (74%) patients with the perimeter method. The mean thin-section-to-thick-section volume difference became nonsignificant with the perimeter method but remained significant with the elliptical method. Measured lung tumor volumes vary significantly with varying CT section width; overestimation varies directly with section width and inversely with tumor size. Compensatory equations that are somewhat effective in reducing these effects can be derived.
- 1 October 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 229 (1) , 184-194
Effect of Varying CT Section Width on Volumetric Measurement of Lung Tumors and Application of Compensatory Equations
To determine how volume measurements of simulated and clinical lung tumors at standard computed tomographic (CT) lung window and level settings vary with section width and to derive and apply compensatory equations. Spherical simulated tumors of varying diameters were imaged with varying CT section widths, the images were displayed on a workstation, the cross-sectional area of the tumor on each section was measured by using elliptical and perimeter methods, and the areas were integrated to compute tumor volume. The actual and measured tumor volumes for differing section widths and tumor diameters were compared, and compensatory equations were derived. The equations were applied to contemporaneous chest CT images obtained in patients with stage I lung cancer, and the difference between thick- and thin-section-derived volumes before and after application of the equations was determined. All simulated tumor volumes were overestimated 11%-278%; overestimation varied directly with section width and inversely with tumor diameter. With both measurement methods, mean thin-section volumes of clinical tumors in 55 patients were significantly smaller (P <.01) than mean thick-section volumes: Mean elliptical measurements were 15,025 mm3 (thin) and 18,037 mm3 (thick), with a 20.0% difference; mean perimeter measurements were 16,164 mm3 (thin) and 20,718 mm3 (thick), with a 22.2% difference. The thin-section-to-thick-section volume difference was larger for the smallest tumors. Thin-section volumes were smaller than thick-section volumes in 53 patients with the elliptical method and in 51 patients with the perimeter method. Applying the equations decreased the difference between thick- and thin-section volumes in 37 (67%) of the 55 patients with the elliptical method and in 41 (74%) patients with the perimeter method. The mean thin-section-to-thick-section volume difference became nonsignificant with the perimeter method but remained significant with the elliptical method. Measured lung tumor volumes vary significantly with varying CT section width; overestimation varies directly with section width and inversely with tumor size. Compensatory equations that are somewhat effective in reducing these effects can be derived.
- Top Cited Papers
- 1 August 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 224 (2) , 487-492
Pulmonary Embolism in Pregnant Patients: Fetal Radiation Dose with Helical CT
To calculate mean fetal radiation dose from helical chest computed tomography (CT) by using maternal-fetal geometries obtained from healthy pregnant women and to compare the calculated CT doses with the fetal doses reported with scintigraphy. Maternal-fetal geometries were determined in 23 pregnant women with varying body mass index and fetal gestational age. Monte Carlo techniques were used to estimate the dose that would be received by each fetus from CT scanning performed with the following parameters: 120 kVp; 100 mA; scanning time, 1 second per section; collimation, 2.5 mm; pitch of 1. Craniocaudal extent of the scan was 11 cm, with the most caudal section edge being 5 mm inferior to the xiphoid process. For helical CT, estimated mean fetal doses in micrograys at varying gestational ages were as follows: 3.3-20.2 microGy, first trimester; 7.9-76.7 microGy, second trimester; and 51.3-130.8 microGy, third trimester. These values were all less than mean fetal doses reported with scintigraphy, with 37-74 MBq of macroaggregates of human serum albumin labeled with technetium 99m. If 200 mAs (pitch of 1.8) was used, the mean fetal doses were still less than those with scintigraphy. The average fetal radiation dose with helical CT is less than that with ventilation-perfusion lung scanning during all trimesters.
- 1 August 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 224 (2) , 487-492
Top Cited PapersPulmonary Embolism in Pregnant Patients: Fetal Radiation Dose with Helical CT
To calculate mean fetal radiation dose from helical chest computed tomography (CT) by using maternal-fetal geometries obtained from healthy pregnant women and to compare the calculated CT doses with the fetal doses reported with scintigraphy. Maternal-fetal geometries were determined in 23 pregnant women with varying body mass index and fetal gestational age. Monte Carlo techniques were used to estimate the dose that would be received by each fetus from CT scanning performed with the following parameters: 120 kVp; 100 mA; scanning time, 1 second per section; collimation, 2.5 mm; pitch of 1. Craniocaudal extent of the scan was 11 cm, with the most caudal section edge being 5 mm inferior to the xiphoid process. For helical CT, estimated mean fetal doses in micrograys at varying gestational ages were as follows: 3.3-20.2 microGy, first trimester; 7.9-76.7 microGy, second trimester; and 51.3-130.8 microGy, third trimester. These values were all less than mean fetal doses reported with scintigraphy, with 37-74 MBq of macroaggregates of human serum albumin labeled with technetium 99m. If 200 mAs (pitch of 1.8) was used, the mean fetal doses were still less than those with scintigraphy. The average fetal radiation dose with helical CT is less than that with ventilation-perfusion lung scanning during all trimesters.
- 1 June 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 223 (3) , 798-805
Volumetric Growth Rate of Stage I Lung Cancer prior to Treatment: Serial CT Scanning
To determine the range of growth rates of stage I lung cancers prior to treatment by using volumetric measurement at serial chest computed tomographic (CT) examinations. The study population comprised 50 patients who underwent two CT examinations at 25-day or greater intervals. Tumor craniocaudal length and cross-sectional diameters and perimeters were used to volumetrically model each tumor in three ways (spherical, elliptical, perimeter). Volumes were compared by determining Pearson correlation coefficients. By using these volumes, tumor doubling time was determined for each patient. Volumes measured with all three methods were highly correlated. With the perimeter method, median doubling time was 181 days, with a very wide range. Eleven (22%) of 50 tumors had doubling times of 465 days or more. There was considerable overlap in doubling time between histologic subtypes. Assuming constant growth, only three (6%) of the 50 tumors would have been the size of a stage IA tumor for less than 1 year. Comparison of tumor volumes at serial CT examinations reveals a very wide range of growth rates. Some tumors grow so slowly that biopsy is required to prove they are malignant.
- 1 June 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 223 (3) , 798-805
Volumetric Growth Rate of Stage I Lung Cancer prior to Treatment: Serial CT Scanning
To determine the range of growth rates of stage I lung cancers prior to treatment by using volumetric measurement at serial chest computed tomographic (CT) examinations. The study population comprised 50 patients who underwent two CT examinations at 25-day or greater intervals. Tumor craniocaudal length and cross-sectional diameters and perimeters were used to volumetrically model each tumor in three ways (spherical, elliptical, perimeter). Volumes were compared by determining Pearson correlation coefficients. By using these volumes, tumor doubling time was determined for each patient. Volumes measured with all three methods were highly correlated. With the perimeter method, median doubling time was 181 days, with a very wide range. Eleven (22%) of 50 tumors had doubling times of 465 days or more. There was considerable overlap in doubling time between histologic subtypes. Assuming constant growth, only three (6%) of the 50 tumors would have been the size of a stage IA tumor for less than 1 year. Comparison of tumor volumes at serial CT examinations reveals a very wide range of growth rates. Some tumors grow so slowly that biopsy is required to prove they are malignant.